Plan Review Details - Permit 18030167
Plan Review Stops For Permit 18030167 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-04-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-28 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-28 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-03-09 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-03-09 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-03-09 |
Time |
13:11 |
Sent To |
|
|
Notes |
2018-03-09 13:55:37 | ****PLAN REVIEW COMMENTS**** | | | | ART LANGE BUILDING PLANS EXAMINER | | | | DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS STREET | | WEST PALM BEACH, FL 33402 | | 561-805-6718 [email protected] | | | | FBC FLORIDA BUILDING CODE 2017 6TH EDITION W/2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 1. ON BATHROOM DOORS 4 AND 5 DO THEY HAVE DOOR | | CLOSURES? IT IS NOT SHOWN ON THE DOOR SCHEDULE. | | | | IF A CLOSURE IS PROVIDED SHOW A 12 INCH CLEARANCE AT | | THE LATCH PULL SIDE OF THE DOOR. | | | | ACCESSIBILITY 404.2.4 MANEUVERING CLEARANCES. | | | | MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL | | COMPLY WITH 404.2.4. MANEUVERING CLEARANCES SHALL | | EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED | | LATCH SIDE OR HINGE SIDE CLEARANCE. | | DOORS AT THE CARE SUITES AND THE ATTACHED BATHROOMS | | SHALL HAVE A CLEAR DISTANCE ON THE LATCH PUSH SIDE OF | | THE DOOR OF A MINIMUM OF 12 INCHES. SEE FLORIDA | | ACCESSIBILITY CODE FIGURE 404.2.4.1 DETAIL (C). | | | | 2. STAFF ROOM 110 APPEARS TO BE ABOUT 5 FT 3 INCHED | | WIDE. THE MINIMUM ROOM WIDTH IS 7 FT. | | FBC 1208.1 MINIMUM ROOM WIDTHS. | | HABITABLE SPACES, OTHER THAN A KITCHEN, SHALL BE NOT | | LESS THAN 7 FEET (2134 MM) IN ANY PLAN DIMENSION. | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | THE PERMIT PACKAGE. | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-05-15 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-05-15 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-05-15 |
Time |
10:43 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-04-27 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-04-27 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-04-27 |
Time |
10:16 |
Sent To |
|
|
Notes |
2018-04-27 13:01:41 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. CORRECTED. | | 2. CORRECTED. | | 3. CORRECTED. | | 4. CORRECTED. | | 5. RISER SHOWS THAT PANEL EP-2 IS FED FROM PANEL EP-1, | | BUT THE PANEL SCHEDULE FOR EP-1 DOES NOT SHOW ANY FEED | | TO THIS PANEL OR THE LOAD ASSOCIATED WITH IT. PROVIDE | | CORRECTION. FBC 107.2.1 (PANELS ARE NOW NAMED | | DIFFERENTLY, BUT THE PANEL SCHEDULES ARE NOT SUPPLIED | | FOR THE PANELS SHOWN, AND THE LOAD FOR EACH PANEL IS | | NOT DETAILED. PROVIDE COMPLETED PANEL SCHEDULES WITH | | LOADS FOR THE PANELS TO CONFIRM THE PANELS ARE NOT | | OVERLOADED.) | | 6. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30 (NOT PROVIDED.) | | 7. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1: | | 8.4.2. PER THIS REQUIREMENT, THE FOLLOWING SHALL BE | | AUTOMATICALLY CONTROLLED: 1) AT LEAST 50% OF ALL | | 125-VOLT, 15 AND 20 AMP RECEPTACLES, IN ALL PRIVATE | | OFFICES, CONFERENCE ROOMS, ROOMS USED PRIMARILY FOR | | PRINTING AND/OR COPYING FUNCTIONS, BREAK ROOMS, | | CLASSROOMS, AND INDIVIDUAL WORKSTATIONS. 2) AT LEASE | | 25% OF BRANCH CIRCUIT FEEDERS INSTALLED FOR MODULAR | | FURNITURE NOT SHOWN ON THE CONSTRUCTION DOCUMENTS. FBC | | EC C405.6.1 (NOT PROVIDED. A NOTE THAT STATES ALL | | NON-ESSENTIAL OUTLETS TO BE TIME CLOCK CONTROLLED IS | | NOT SUFFICIENT. THE EXCEPTION NOTED IN RESPONSE LETTER | | IS ONLY FOR RECEPTACLES DESIGNATED FOR EQUIPMENT THAT | | REQUIRES CONTINUOUS OPERATION. SHOW ON PLAN WHICH | | RECEPTACLES WILL BE TIME CLOCK CONTROLLED, IN | | COMPLIANCE WITH ABOVE REQUIREMENT.) | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-03-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-03-22 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-03-22 |
Time |
14:49 |
Sent To |
|
|
Notes |
2018-03-22 14:49:27 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ELECTRICAL NOTE 1 AND 17 ON SHEETS CS-1 AND MEP 1 | | THROUGH 4 STATE THAT THE 2011 NEC IS USED FOR DESIGN. | | THIS IS NOT THE CURRENT CODE IN EFFECT. PROVIDE | | CORRECTIONS. FBC PREFACE | | 2. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLES IN | | KITCHEN. NEC 210.8(B)(2) | | 3. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND | | SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN | | THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE | | INDICATING THE REQUIRED SEPARATE PERMITS AND DATA | | SPECIFICATION SHEET SUBMITTALS FOR ANY OF THESE SYSTEMS | | PRESENT. WPB FBC 105.1, 107.2.1 | | 4. PANELS ARE SHOWN AS 3?, 120/240 VOLT, WHICH WOULD | | HAVE B? AS A HIGH LEG. HOWEVER, THE PANEL SCHEDULES | | SHOWS 120 VOLT LOADS ON B?. PROVIDE CLARIFICATION | | AND/OR CORRECTION. FBC 107.2.1 | | 5. RISER SHOWS THAT PANEL EP-2 IS FED FROM PANEL EP-1, | | BUT THE PANEL SCHEDULE FOR EP-1 DOES NOT SHOW ANY FEED | | TO THIS PANEL OR THE LOAD ASSOCIATED WITH IT. PROVIDE | | CORRECTION. FBC 107.2.1 | | 6. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30 | | 7. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1: | | 8.4.2. PER THIS REQUIREMENT, THE FOLLOWING SHALL BE | | AUTOMATICALLY CONTROLLED: 1) AT LEAST 50% OF ALL | | 125-VOLT, 15 AND 20 AMP RECEPTACLES, IN ALL PRIVATE | | OFFICES, CONFERENCE ROOMS, ROOMS USED PRIMARILY FOR | | PRINTING AND/OR COPYING FUNCTIONS, BREAK ROOMS, | | CLASSROOMS, AND INDIVIDUAL WORKSTATIONS. 2) AT LEASE | | 25% OF BRANCH CIRCUIT FEEDERS INSTALLED FOR MODULAR | | FURNITURE NOT SHOWN ON THE CONSTRUCTION DOCUMENTS. FBC | | EC C405.6.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-04-24 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-04-24 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-04-24 |
Time |
14:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2018-03-08 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-03-08 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-03-08 |
Time |
13:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-05-21 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-05-10 |
Time |
12:34 |
Sent To |
|
|
Notes |
2018-05-14 12:34:40 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-04-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-28 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-12 |
Time |
10:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-03-23 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-03-05 |
Time |
15:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2018-03-09 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-03-09 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-03-09 |
Time |
13:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2018-05-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-05-21 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-05-21 |
Time |
14:52 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2018-04-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-04-24 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-04-24 |
Time |
16:27 |
Sent To |
|
|
Notes |
2018-04-24 16:51:01 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT #18030167 | | 4/24/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE PLAN SHOWS RETURN AIR BEING TAKEN FROM THE | | ADJACENT MAINTENANCE ROOM, HOWEVER THE CONTENTS OF THAT | | ROOM ARE UNKNOWN, AND RETURN AIR FROM THAT ROOM MAY BE | | PROHIBITED- SEE SECTION 601.5 ITEMS #1, 2 & 7. AND | | VERIFY COMPLIANCE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-03-15 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-03-15 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-03-15 |
Time |
16:56 |
Sent To |
|
|
Notes |
2018-03-16 07:57:11 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18030167 | | 3/16/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET MEP-1: REFER TO SECTION 809.2 FBC-14 EXISTING | | BUILDING CODE AND PROVIDE MINIMUM VENTILATION | | CALCULATIONS FOR ALL ALTERED ROOMS AND SPACES PER TABLE | | 403.3.1 FBC-17 MECHANICAL. PROVIDE A SCHEDULE THAT | | INDICATES THE REQUIRED AND PROVIDED CFMS OF OUTDOOR | | AIR. | | | | 2) MEP-1: FLEX DUCT CANNOT BE USED FOR THE TOILET ROOM | | EXHAUST PER UL AND MANUFACTURER'S SPECIFICATIONS. | | PROVIDE METAL DUCTWORK PER SMACNA STANDARDS. | | | | 3) MEP-1: CLARIFY IF THE EF-1 FANS ARE NEW OR EXISTING. | | PROVIDE EQUIPMENT SCHEDULES FOR NEW. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-04-23 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-04-23 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-04-21 |
Time |
10:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-03-23 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-03-23 |
Time |
07:42 |
Sent To |
|
|
Notes |
2018-03-23 10:16:29 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.4 SEATS. THE | | SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH FLOOR | | SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES (485 | | MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS | | SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. | | | | 2. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | THE CENTERLINE OF THE DISPENSER. PER FBC ACC 604.7 | | | | 3. GRAB BARS TO BE MEASURED TO THE TOP OF THE GRIPPING | | SURFACE OFF FINISHED FLOOR. PER FBC ACC 609.4 | | | | 4. PLEASE SHOW COMPLIANCE WITH THE REQUIREMENT FOR A | | WATER FOUNTAIN. PER FBC PL TABLE 403.1 | | | | 5. SHT. A-3 UNDER NOTE SCOPE OF WORK IN EXISTING | | BATHROOM THERE ARE NO EXISTING BATHROOMS SHOWN IN AREA | | OF WORK PLEASE CLARIFY WHERE THIS WORK IS BEING DONE. | | PER WPB AND TO FBC 107.2.1 | | | | 6. PLEASE STATE ON THE PLAN WHAT LEVEL OF ALTERATION | | THIS PROJECT IS PER FBC EX CH 2 | | | | 7. SHOW COMPLIANCE WITH FBC PL 607.3 | | | | 8. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 | | | | 9. WHAT TYPE OF PIPE IS SHOWN ON THE FIRE STOPPING | | DETAILS PROVIDE DETAILS FOR ALL TYPES OF PIPE AND | | INSTALLATIONS PER WPB AMEND TO FBC 107.2.1.3 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2018-04-18 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2018-04-18 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2018-04-18 |
Time |
10:09 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |