Plan Review Stops For Permit 18030157 |
Review Stop |
AD |
ADDRESSING |
Rev No |
3 |
Status |
P |
Date |
2019-05-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-05-17 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-05-09 |
Time |
09:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2019-03-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-03-13 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-03-12 |
Time |
15:52 |
Sent To |
|
|
Notes |
2019-03-13 08:25:08 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | ADDRESSING IS INCORRECT FOR STRUCTURES | | | | A UNITY OF TITLE WAS FILED ON 2/15/2018 (BOOK | | 29652/PG1217) | | | | PARCELS HAVE NOT BEEN UNIFIED ON PALM BEACH COUNTY | | PROPERTY APPRAISERS OFFICE AS OF THIS DATE | | | | AN E-MAIL HAS BEEN SENT TO MICHAEL ORIO, GIS SUPPORT | | SPECIALIST, CITY OF WEST PALM BEACH AND CAROLINE GLASS, | | PALM BEACH COUNTY REQUESTING THE UNITY OF THE PARCEL | | AND CORRECT ADDRESSING OF THIS PROPERTY BE RECORDED | | | | A NEW SITE PLAN WILL BE REQUIRED WITH THE CORRECT | | ADDRESS OF EACH STRUCTURE ON THE PROPERTY | | | | | | | | |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2018-10-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-10-30 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-10-30 |
Time |
11:23 |
Sent To |
|
|
Notes |
2018-10-30 11:25:43 | 10/30 - UNITY OF TITLE RECORDED 2/15/18 (BOOK 29652/PG | | 1217), CONFIRMED W/VINCE NOEL | | | | THE PLANS DO NOT APPEAR TO BE CONSISTENT - AREA OF WORK | | SHOWN DOES NOT APPEAR TO BE FOR THE CORRECT BUILDING. | | | | TWO DIFFERENT PARCELS HAVE THE SAME ADDRESS. UNIQUE | | ADDRESSES ARE REQUIRED PER CITY STANDARDS. | | | | | | FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL): | | | | MICHAEL ORIO | | GIS SUPPORT SPECIALIST | | [email protected] | | CITY OF WEST PALM BEACH | | INFORMATION TECHNOLOGY DEPARTMENT | | 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401 | | P: 561.494.1080 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2019-05-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-05-17 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-05-09 |
Time |
09:52 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2019-03-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-03-13 |
Time |
08:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-03-12 |
Time |
09:23 |
Sent To |
|
|
Notes |
2019-03-13 08:31:01 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 4TH REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. RESUBMITTAL WILL BE REQUIRED AFTER THE CORRECT | | ADDRESSES HAVE BEEN RECORDED WITH PALM BEACH COUNTY | | PROPERTY APPRAISERS OFFICE. A NEW SITE PLAN SHALL HAVE | | THE CORRECT ADDRESS OF EACH STRUCTURE. | | SEE NOTES UNDER ADDRESS REVIEW. | | | | 2. EACH STRUCTURE ON PROPERTY REQUIRES A SEPERATE | | ADDRESS. | | | | 3. A SEPERATE PERMIT IS REQUIRED FOR EACH STRUCTURE | | THAT WORK WILL BE PERFORMED ON. | | | | 4. ALL STRUCTURES MAY BE INCLUDED ON A SINGLE SET OF | | PLANS. EACH STRUCTURE MUST BE IDENTIFIED BY ADDRESS. | | EACH PLAN AND/OR DETAIL SHALL BE IDENTIFIED BY ADDRESS. | | | | 5. AS AN EXAMPLE - PLEASE REFERENCE NOTES 2 & 4 ON PLAN | | PAGE C-1.0. "CUT 5X8 OPENING BETWEEN 925 & 1013" THESE | | TWO BUILDING ARE NOT ATTACHED. | | | | 6. REFERENCE PROJECT DATA ON PLAN PAGE C-1.0. PROPOSED | | OCCUPANCY IS LISTED AS MERCANTILE. DEPENDING ON THE | | SPECIFIC BUILDING THERE SHOULD ALSO BE AN A-3 ASSEMBLY | | OCCUPANCY AND A BUSINESS OCCUPANCY. | | | | 7. REFER TO PLAN PAGE LS-1.0 - NOTE: THE WORK AREA IS | | THE METHOD USED TO COMPLY WITH THE FBCEB. PLEASE | | CLARIFY? | | | | 8. REFER TO PLAN PAGE LS-3.0 - THE USE OF A REVISION | | SYMBOL ON THE PLAN SHOULD COINCIDE WITH A NARRATIVE OF | | ALL WORK INCLUDED UNDER THE REVISION. THIS IS USUALLY | | PLACED IN THE MARGIN OF THE PLAN PAGE FOR REFERENCE. | | | | 9. PROVIDE PRODUCT APPROVALS FOR ALL STOREFRONTS, DOORS | | AND WINDOWS TO BE INSTALLED. DESIGNER TO REVIEW AND | | APPROVE IN WRITING. NO SEAL REQUIRED. | | | | 10 PROVIDE WINDOW AND DOOR SCHEDULE. LIST ALL ROUGH | | OPENINGS WITH DESIGN PRESSURES FOR EACH OPENING. | | SPECIFY WHICH PRODUCT WILL BE INSTALLED IN EACH | | OPENING. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2018-08-28 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-08-28 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-08-28 |
Time |
08:36 |
Sent To |
|
|
Notes |
2018-08-28 12:05:05 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 3RD REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. SCOPE OF WORK HAS CHANGED DUE TO THE CHANGE OF | | OCCUPANCY. ADDITIONAL REVIEWS REQUIRED - MECH., | | ELECTRICAL, PLUMBING AND ZONING. | | FBC EXISTING SEC. 1001.2.2 CHANGE OF OCCUPANCY | | CLASSIFICATION OR GROUP. | | WHERE THE OCCUPANCY CLASSIFICATION OF A BUILDING | | CHANGES, THE PROVISIONS OF SECTIONS 1002 THROUGH 1012 | | SHALL APPLY. THIS INCLUDES A CHANGE OF OCCUPANCY | | CLASSIFICATION AND A CHANGE TO ANOTHER GROUP WITHIN AN | | OCCUPANCY CLASSIFICATION. | | | | 2. CHANGE CLASSIFICATION OF WORK ON PLAN PAGE CV-1.0 | | FROM ALTERATION LEVEL II TO CHANGE OF OCCUPANCY. NEW | | CLASSIFICATION SHOULD BE A-3 GALLERY. | | 303.4 ASSEMBLY GROUP A-3. | | GROUP A-3 OCCUPANCY INCLUDES ASSEMBLY USES INTENDED FOR | | WORSHIP, RECREATION OR AMUSEMENT AND OTHER ASSEMBLY | | USES NOT CLASSIFIED ELSEWHERE IN GROUP A INCLUDING, BUT | | NOT LIMITED TO: | | ART GALLERIES | | | | 3. APPLICABLE BUILDING CODES ON PLAN PAGE C-1 ARE | | INCORRECT. CURRENT GOVERNING CODE IS THE 2017 FBC | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 4. DRAWING SCHEDULE ON PLAN PAGE C-1 IS INCORRECT. | | COVER SHEET IS CV-1.0. SITE PLAN IS C-1. | | | | 5. DRAWING SCALE ON PLAN PAGES A-1, A-2 AND A-3 IS TOO | | SMALL. MINIMUM SCALE IS 1/8" = 1 FOOT. | | FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | RECORDS MANAGEMENT. | | | | 6. MINIMUM NUMBER OF PLUMBING FACILITIES SHALL COMPLY | | WITH FBC CHPT. 29. | | FBC 2902.1 MINIMUM NUMBER OF FIXTURES. | | PLUMBING FIXTURES SHALL BE PROVIDED IN THE MINIMUM | | NUMBER AS SHOWN IN TABLE 2902.1 BASED ON THE ACTUAL USE | | OF THE BUILDING OR SPACE. USES NOT SHOWN IN TABLE | | 2902.1 SHALL BE CONSIDERED INDIVIDUALLY BY THE CODE | | OFFICIAL. THE NUMBER OF OCCUPANTS SHALL BE DETERMINED | | BY THIS CODE. | | | | 7. REFERENCE PLAN PAGE S-1.0 FOR THE FOLLOWING | | COMMENTS. | | 7A. PROVIDE DESIGN WIND LOADS FOR CONTAINERS. | | ENGINEERING TO BE SIGNED AND SEALED BY A DESIGN | | PROFESSIONAL. | | 7B. PROVIDE DESIGN FOR FOUNDATION. IF EXISTING, PROVIDE | | CERTIFICATION BY A DESIGN PROFESSIONAL. | | 7C. PROVIDE ATTACHMENT DETAIL FOR CONTAINER TO | | FOUNDATION. | | 7D. PROVIDE WELD SPECIFICATIONS. | | 7E. PROVIDE WELDER CERTIFICATIONS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-07-13 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-07-06 |
Time |
10:14 |
Sent To |
|
|
Notes |
2018-07-13 08:10:12 | THE CITY HAS BEEN REQUESTING AN OVERALL SITE PLAN FOR | | THIS PROJECT IN ORDER TO ASSIGN OCCUPANCIES, FIRE | | SEPARATION DISTANCES, BUILDING HEIGHT AND USE FOR THE | | VARIOUS PIECES AND PARTS THAT ARE PRESENT ON THE SITE. | | TO DATE, A FULL AND COMPRHENSIVE SITE PLAN HAS YET BE | | TO BE PRESENTED. THIS HAS PREVENTED US FROM COMPLETING | | A COMPREHENSIVE REVIEW. THE WORK MAY BE PHASED OR | | STAGED TO VARIOUS COMPONENTS OF THE PROJECT ONCE THE | | OVERALL PROJECT IS DEFINED, CLEARLY STATED, SHOWN ON A | | DIMENSIONED SITE PLAN AND APPROVED FOR THE USES THAT | | ARE BEING REQUESTED. BOTH FIRE AND PLANNING/ZONING NEED | | TO REVIEW THE MIXED USE OF THIS PROPERTY AND APPROVE | | THE USES IN THE LOCATIONS THAT ARE REQUESTED. AT THIS | | TIME, IT IS BELIEVED THERE ARE GOUP B, BUSINESS USE(S), | | GROUP S, STORAGE USE(S), GROUP A, ASSEMBLY USE(S) AND | | POSSIBLY OTHERS. UNTIL AN OVERALL OCCUPANT LOAD, USE | | AND LIMITS OF PROPERTY ARE DETERMINED AND DEFINED, IT | | IS NOT POSSIBLE TO COMPLETE A REVIEW OF THE PROJECT. | | | | THE PLANS SUBMITTED UNDER TJHIS REQUEST ARE MISSING | | IMPORTANT AND VALUABLE INFORMATION NEEDED FOR THE | | REVIEW. THOSE ITEMS INCLUDE, BUT ARE NOT LIMITED TO: | | OVERALL SITE PLAN | | USE OF THE PROPERTY | | OCCUPANT LOAD FOR EACH PORTION AND USE | | WIND LOAD CALCULATIONS AND AFFIRMATION OF COMPLIANCE | | WELDING PROCEDURE SPECIFICATION (WPS) | | WELDERS CERTIFICATIONS | | COMPLETE LAYOUT INCLUDING LIMITS OF MIXED USES | | COMPLETE AND COMPREHENSIVE LIFE SAFETY PLAN | | SPRINKLER PLANS | | ALL OTHER REQUIRED INFORMATION BY FLORIDA BUILDING CODE | | - BUILDING SECTION 107 | | | | REVIEW IS UNABLE TO BE COMPLETED UNTIL ALL REQUIRED AND | | PREVIOUSLY REQUESTED INFORMATION IS PROVIDED. | | | | DOUGLAS HARVEY | | ASSISTANT BUILDING OFFICIAL | | [email protected] | | 561-805-6740 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-03-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-16 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-16 |
Time |
14:32 |
Sent To |
|
|
Notes |
2018-03-16 14:37:59 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. BUILDING ENVELOPE CANNOT BE OPENED WITHOUT DOORS | | ON-SITE TO BE INSTALLED. | | 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED DOORS. | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE DOOR SUBMITTALS. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2019-06-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-06-20 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-06-20 |
Time |
10:55 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2019-04-29 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-04-29 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-04-29 |
Time |
13:26 |
Sent To |
|
|
Notes |
2019-04-29 15:34:04 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. THERE ARE TWO DIFFERENT RISER DIAGRAMS PROVIDED WITH | | CONFLICTING INFORMATION. PROVIDE CORRECTION. NEC 215.5; | | WPB FBC 107.2.1 (THE PERMIT APPLICATION STATES THE WORK | | FOR THIS PLAN IS FOR 925 RAILROAD. THE ELECTRICAL PLAN | | SHOULD ONLY INCLUDE INFORMATION FOR WORK AT THAT | | ADDRESS. WHY ARE 2 SEPARATE RISER DIAGRAMS INCLUDED? | | PROVIDE CLARIFICATION AND/OR REMOVE INFORMATION NOT | | PERTINENT TO THIS PERMIT APPLICAITON.SOME SHEETS STATE | | THE WORK IS FOR 925 ADDRESS, SOME SHEETS STATE THE WORK | | IS FOR 925/1013, BUT THE FLOOR PLANS DO NOT INDICATE | | WHICH ADDRESS OR WHERE EXACTLY THE WORK IS TO BE | | PERFORMED.) | | 2. THE LOAD CALCULATION PROVIDED DOES NOT RECONCILE | | WITH INFORMATION PROVIDED ON PANEL SCHEDULES. PROVIDE | | CORRECTION SO LOAD FOR EACH AREA IS DETAILED CORRECTLY. | | NEC 220; WPB FBC 107.2.1(NOT CORRECTED. LOAD | | CALCULATION ON SHEET E2.0 STATES THE LOAD IS 440.59 | | AMPS, WHILE THE PANEL SCHEDULE FOR THE SAME SERVICE | | STATES THE LOAD AS 251 AMPS. PROVIDE CORRECTION AS | | PREVIOUSLY REQUESTED.) | | 3. CORRECTED. | | 4. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | LIGHTING PROPOSED TO COMPLY WITH CODE. THE CURRENT | | INFORMATION PROVIDED SHOWS THE AMPERAGE LOAD OF | | LIGHTING, THIS IS NOT ACCEPTABLE FOR CODE COMPLIANCE. | | SEE CODE SECTION FOR DETAILS. FBC EC C405.4.2 (NOT | | PROVIDED.) | | 5. THERE IS A SUBSTANTIAL AMOUNT OF INFORMATION ON THIS | | PLAN THAT IS CONFLICTING AND/OR MISSING. A FULL REVIEW | | IS NOT POSSIBLE AT THIS TIME. FURTHER COMMENTS MAY BE | | NECESSARY UPON NEXT REVIEW. WPB FBC 107.2.1(COMMENT | | STILL APPLIES.) | | | | NEW COMMENT: | | | | 6. FOR NEW SERVICE ON SHEET E2.0, PROVIDE AVAILABLE | | SHORT CIRCUIT CALCULATION FOR SERVICE INCLUDING | | INFORMATION FROM THE POWER COMPANY STATING WHAT THE | | AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE SERVICE TO | | CONFIRM THE AIC RATING OF THE SERVICE EQUIPMENT IS | | ADEQUATE. PROVIDE AIC RATING OF ELECTRICAL PANELS.NEC | | 110.9, 110.10 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-02-25 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-02-25 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-02-25 |
Time |
12:13 |
Sent To |
|
|
Notes |
2019-02-25 14:15:51 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. THERE ARE TWO DIFFERENT RISER DIAGRAMS PROVIDED WITH | | CONFLICTING INFORMATION. PROVIDE CORRECTION. NEC 215.5; | | WPB FBC 107.2.1 | | 2. THE LOAD CALCULATION PROVIDED DOES NOT RECONCILE | | WITH INFORMATION PROVIDED ON PANEL SCHEDULES. PROVIDE | | CORRECTION SO LOAD FOR EACH AREA IS DETAILED CORRECTLY. | | NEC 220; WPB FBC 107.2.1 | | 3. PROVIDE THE ADDITIONAL INTERIOR LIGHTING CONTROLS | | STIPULATED IN THE FBC ENERGY CODE. MANY AREAS DO NOT | | SHOW THE AUTOMATIC CONTROL REQUIRED. FBC EC C405.2 | | 4. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | LIGHTING PROPOSED TO COMPLY WITH CODE. THE CURRENT | | INFORMATION PROVIDED SHOWS THE AMPERAGE LOAD OF | | LIGHTING, THIS IS NOT ACCEPTABLE FOR CODE COMPLIANCE. | | SEE CODE SECTION FOR DETAILS. FBC EC C405.4.2 | | 5. THERE IS A SUBSTANTIAL AMOUNT OF INFORMATION ON THIS | | PLAN THAT IS CONFLICTING AND/OR MISSING. A FULL REVIEW | | IS NOT POSSIBLE AT THIS TIME. FURTHER COMMENTS MAY BE | | NECESSARY UPON NEXT REVIEW. WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-09-06 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-09-06 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-09-06 |
Time |
14:02 |
Sent To |
|
|
Notes |
2018-09-06 14:02:04 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. THE PLAN SUBMITTED IS THE EXACT PLAN THAT WAS | | SUBMITTED FOR PERMIT 17120517. IS THIS PERMIT FOR | | ADDRESS 925 N RAILROAD, OR 1013 N RAILROAD? AS THESE | | ARE 2 SEPARATE LOCATIONS, THE SAME PLAN WOULD NOT BE | | USED FOR BOTH. PROVIDE CLARIFICATION AND SUBMIT PROPER | | PLAN FOR REVIEW, A REVIEW IS NOT POSSIBLE AT THIS TIME. | | WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-05-01 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-05-01 |
Time |
11:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2019-02-19 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-02-19 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-02-19 |
Time |
11:17 |
Sent To |
|
|
Notes |
2019-02-19 11:19:12 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) SHEET LS .01 - THERE IS NOTE INDICATED, DIAMOND 1, | | FOR A FIRE DEPARTMENT CONNECTION. ACCORDING TO OTHER | | NOTES THERE IS NO FIRE SPRINKLER SYSTEM. | | | | THE FDC NOTE IS NOT APPLICABLE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-07-03 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-07-03 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-07-03 |
Time |
13:42 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2018-03-08 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-03-08 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-03-07 |
Time |
16:46 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-07-15 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-07-09 |
Time |
16:43 |
Sent To |
|
|
Notes |
2019-07-10 16:43:38 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-06-26 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-06-12 |
Time |
15:36 |
Sent To |
|
|
Notes |
2019-06-13 15:37:03 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-05-27 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-04-10 |
Time |
15:57 |
Sent To |
|
|
Notes |
2019-05-20 06:56:56 | TO ZONING BIN | | | | | 2019-04-11 15:57:34 | C05 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2019-03-15 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-03-15 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-02-06 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-10-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-10-30 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-08-23 |
Time |
15:11 |
Sent To |
|
|
Notes |
2018-08-24 15:12:01 | RESUB ROUTED TO CTHROOP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-07-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-07-13 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-06-29 |
Time |
15:21 |
Sent To |
I |
|
Notes |
2018-07-02 15:21:51 | RESUB ROUTED TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-03-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-16 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-05 |
Time |
10:09 |
Sent To |
I |
|
Notes |
2018-03-07 10:09:35 | ROUTED TO FIRE INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2019-07-15 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-07-15 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-07-15 |
Time |
08:37 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2019-06-26 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-06-26 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-06-26 |
Time |
12:12 |
Sent To |
|
|
Notes |
2019-06-26 12:28:01 | 4TH REVIEW FBC-2017 MECHANICAL | | PERMIT #18030157 | | 6/26/19 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M2.0: THE RHEEM AC EQUIPMENT MODELS IN THE | | SCHEDULE ARE STRAIGHT COOL SYSTEMS PER THE | | MANUFACTURER'S SPECIFICATIONS, HOWEWER THE COMCHECK | | ENERGY COMPLIANCE REPORT LISTS THEM AS HEAT PUMPS. | | PLEASE CORRECT THE DATA AND REMOVE THE HSPF RATINGS | | WHICH ARE NOT RELEVANT TO THE SYSTEMS. EFFICIENCIES FOR | | THE SYSTEMS ARE RATED IN SEER FOR SYSTEMS #1, 2, 3, & | | 5, AND EER FOR THE 10-TON SYSTEM #4. PLEASE NOTE THAT | | TWO SIGNED AND SEALED COPIES BY THE ENGINEER OF RECORD | | ARE REQUIRED- SECTION 107/.2.1 WPB. | | | | 2) AS PREVIOUSLY REQUESTED TWO COMPLETE SETS OF SIGNED | | AND SEALED AC CALCULATIONS ARE REQUIRED. CURRENTLY ONLY | | CALCULATIONS FOR SYSTEMS #1 & 2 HAVE BEEN PROVIDED. | | PLEASE NOTE THAT THE CURRENT CALCULATIONS SHOW NO HEAT | | GAIN FOM VENTILATION AIR WHICH MUST BE INCLUDED AND | | SHOWN IN THE RESUBMITTED CALCULATIONS- SECTION 107.2.1 | | WPB. | | | | 3) M2.0: THE AC EQUIPMENT SCHEDULE IS INDICATING ONLY | | 2000 CFMS FOR THE AHU-4, HOWEVER THE MANUFACTURER'S | | SPECIFICATIONS INDICATE 4000 CFMS NOMINAL FOR THE UNIT- | | RHGL-120. | | | | 4) M1.0: THE REVISED AC PLAN IS NOW SHOWING O/A TO BE | | DUCTED THROUGH THE EXTERIOR WALLS USING INTERIOR FANS, | | HOWEVER THE EQUIPMENT SCHEDULE IS INDICATING ROOF | | MOUNTED FANS- GREENHECK SAF. PLEASE CORRECT AND NOTE | | THAT THE O/A OPENINGS IN THE EXTERIOR WALLS MUST BE | | PROTECTED WITH CORROSION-RESISTENT SCREENS, LOUVERS, OR | | GRILLES- SECTION 401.5 FBC M. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2019-04-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-04-25 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-04-24 |
Time |
17:43 |
Sent To |
|
|
Notes |
2019-04-25 10:49:30 | 3RD REVIEW FBC-2017 MECHANICAL | | PERMIT #18030157 | | 4/25/19 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M-1.0: COMMENT #7 FROM THE 2ND REVIEW STILL | | EXISTS- PLEASE COMPLY.7) M-1.0: DUCT SMOKE DETECTORS | | ARE REQUIRED IN THE SUPPLY SYSTEMS OF THE 5-TON AHU'S | | PER SECTION 606.2.1 FBC M. PLEASE NOTE THAT AN | | EXEMPTION CAN BE APPLIED FOR THE 5-TON SYSTEMS IF THE | | MANUFACTURER'S SPECIFICATIONS INDICATE THOSE SYSTEMS | | ARE NOT CAPABLE OF PRODUCING OVER 2000 CFMS OF SUPPLY | | AIR. | | | | 2) SHEET M2.0: THE RHEEM AC EQUIPMENT MODELS IN THE | | SCHEDULE ARE STRAIGHT COOL SYSTEMS PER THE | | MANUFACTURER'S SPECIFICATIONS, HOWEVWER THE COMCHECK | | ENERGY COMPLIANCE REPORT LISTS THEM AS HEAT PUMPS- | | PLEASE CORRECT. PLEASE NOTE THAT THE AC SCHEDULE | | INDICATES THE AIR HANDLERS ARE NOT EQUIPPED WITH HEAT | | STRIPS, HOWEVER MINIMUM HEAT IS REQUIRED FOR ALL | | OCCUPIED SPACES- SECTION 309.1 FBC M. | | | | 3) COMMENT #3 FROM THE 2ND REVIEW STILL PARTIALLY | | EXISTS. THE ELITE HVAC CALCS HAVE NOT BEEN PROVIDED | | WITH AN ORIGINAL SEAL AND SIGNATURE BY THE EOR. 3) | | ENGINEER'S SEAL ON THE COMCHECK FORM AND THE ELITE HVAC | | CALCS IS A COPIED, REDUCED IN SIZE INK SEAL. PROVIDE | | ORIGINAL 1-7/8" DIAMETER SEALS AND WET SIGNATURES ON | | THE DOCUMENTS- SECTION 61G15-23.002 (2) FAC. | | | | 4) PLEASE NOTE THAT THE AC CALCULATIONS ARE INDICATING | | ONLY TWO AIR HANDLERS- 1 & 2, HOWEVER THERE ARE 5 AIR | | HANDLERS IN THE SPACE. | | | | 5) COMMENT #8 FROM THE 2ND REVIEW STILL EXISTS- PLEASE | | COMPLY. 8) M-1:0: PROVIDE AN EQUIPMENT SCHEDULE ON THE | | PLAN FOR THE CLASSIC CL-2250 FAN, AND PROVIDE INPACT | | PROTECTION AND WIND LOAD ENGINEERING FOR INSTALLATION- | | SECTION 301.15 FBC M. | | | | 6) M-2.0: THE DETAIL PROVIDED FOR THE O/A ROOF FAN | | INSTALLATIONS USING A 6" DUCT EXTENSION ABOVE THE ROOF | | DOES NOT APPEAR TO BE APPLICABLE FOR THE SPECIFIED | | GREENHECK SAF FANS. THESE TYES OF ROOF FANS ARE | | TYPICALLY MOUNTED ON PRE-MANUFACTURED CURBS PER THE | | MANUFACTURER'S SPECIFICATIONS AND PER THE PRODUCT | | APPROVALS OR NOA'S. PLEASE SUBMIT THE SPECS AND THE | | NOA'S. | | | | 7) M-2.0: THE NEW AIR BALANCE SCHEDULE INDICATES | | GREATER AMOUNTS OF RETURN AIR TO THE SYSTEMS THAN THE | | AMOUNTS OF SUPPLY AIR PROVIDED? PLEASE SEE SECTION | | 601.5 (3) FBC M AND CORRECT. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2019-02-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-02-20 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-02-19 |
Time |
16:49 |
Sent To |
|
|
Notes |
2019-02-20 09:30:46 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT #18030157 | | 2/20/19 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) COMMENT #1 FROM THE 1ST REVIEW STILL EXISTS.THE | | $10,000 JOB VALUE FOR THE SCOPE OF WORK SHOWN ON THE | | PLANS IS LOW- SEE SECTION 109.3 WPB AND PROVIDE AN | | ACCURATE JOB VALUE. | | | | 2) ENGINEER'S TITLE BLOCK MISSING FROM THE MEP PLANS- | | SECTION 61G15-23.002 FAC. | | | | 3) ENGINEER'S SEAL ON THE COMCHECK FORM AND THE ELITE | | HVAC CALCS IS A COPIED, REDUCED IN SIZE INK SEAL. | | PROVIDE ORIGINAL 1-7/8" DIAMETER SEALS AND WET | | SIGNATURES ON THE DOCUMENTS- SECTION 61G15-23.002 (2) | | FAC. | | | | 4) SHEET M-1.0: THE PROPOSED MECHANICAL PLAN SHALL BE | | DRAWN TO A MINIMUM 1/8" = 1'0" SCALE PER SECTION | | 107.2.1.3 WPB. THE SCALE OF THE PLAN IS LISTED AS 3/32 | | AT THE BOTTOM OF THE PLAN, HOWEVER LISTED AS 3/16" IN | | THE MARGIN. PLEASE NOTE THAT MUCH OF THE PRINT ON THE | | PRINT IS TOO SMALL TO READ DUE TO THE REDUCED SCALE | | SIZE. | | | | 5) THE COMCHECK REPORT IS MISSING ENVELOPE DATA FOR THE | | WEST SIDE OF THE BUILDING WHERE THE NEW STOREFRONT | | GLASS AND WALLS WERE INSTALLED TO ENCLOSED THE GARAGE | | BAYS. THESE ENCLOSURES ARE DEFINED AS ADDITIONS PER | | SECTION 202 FBC EC. THE REPORT IS ALSO LACKING ANY DATA | | FOR THE MECHANICAL SYSTEMS. PLEASE PROVIDE A COMPLETE | | REPORT- SECTION 107.1 WPB. | | | | 6) SHEET M-1.0: PROVIDE VENTILATION CALCULATIONS PER SF | | FOR ALL ROOMS AND SPACES TO VERIFY THE AMOUNTS OF O/A | | TO BE PROVIDED BY THE EXISTING SYSTEMS- SEE TABLE | | 403.3.1.1 FBC M. | | | | 7) M-1.0: DUCT SMOKE DETECTORS ARE REQUIRED IN THE | | SUPPLY SYSTEMS OF THE AHU'S PER SECTION 606.2.1 FBC M. | | PLEASE NOTE THAT AN EXEMPTION CAN BE APPLIED FOR THE | | 5-TON SYSTEMS IF THE MANUFACTURER'S SPECIFICATIONS | | INDICATE THOSE SYSTEMS ARE NOT CAPABLE OF PRODUCING | | OVER 2000 CFMS OF SUPPLY AIR. | | | | 8) M-1:0: PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN FOR | | THE CLASSIC CL-2250 FAN, AND PROVIDE INPACT PROTECTION | | AND WIND LOAD ENGINEERING FOR INSTALLATION- SECTION | | 301.15 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-09-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-09-13 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-09-13 |
Time |
11:59 |
Sent To |
|
|
Notes |
2018-09-13 12:42:24 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18030157 | | 9/13/18 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE $10,000.00 JOB VALUE LISTED ON THE PERMIT | | APPLICATION APPEARS TO BE VERY LOW FOR A 13,798 S.F. | | REMODEL AND CHANGE OF OCCUPANCY, WHICH INCLUDES AMONG | | OTHER THINGS A NEW ACCESSIBLE BATHROOM, A NEW HANDICAP | | RAMP, AND NEW ADDITIONS (LOADING BAY CONVERSIONS) | | PLEASE REFER TO SECTION 109.3 WPB AND PROVIDE DETAILED | | ESTIMATES, AND/OR BONA FIDE CONTRACTS FOR ALL PHASES OF | | THE PROJECT INCLUDING STRUCTURAL, ARCHITECTURAL, | | MECHANICAL, ELECTRICAL, PLUMBING, INTERIOR AND EXTERIOR | | FINISH WORK, SITE WORK, DESIGN FEES, AND OVERHEAD AND | | PROFIT. THE TOTAL VALUE SHALL INCLUDE LABOR, MATERIALS, | | EQUIPMENT AND APPLIANCES. | | | | 2) THE PROJECT INFORMATION, INDEX, ETC. ON COVER SHEET | | CV-1.0 DESIGNED BY CALITO P.E. DOES NOT MATCH THE REST | | OF THE PLANS IN THE SET THAT ARE DESIGNED BY GOUBRAN | | ARCHITECT. PLEASE CORRECT OR REMOVE THE SHEET FROM THE | | SETS. | | | | 3) SHEET M-1: THE O/A CALCULATIONS ARE INCORRECTLY | | IDENTIFYING THE LARGE 11,376 S.F. GALLERY AREAS AS | | SALES. PLEASE SEE TABLE 403.3.1.1 FBC M AND PROVIDE | | CALCULATIONS FOR THE GALLERIES BASED ON AN OCCUPANT | | DENSITY OF 40 PERSONS PER 100 S.F./7.5 CFMS PER PERSON | | + 0,06 CFMS PER S.F. ADJUST THE TABLE TO SHOW THE | | REQUIRED AND PROVIDED CFMS OF OUTSIDE AIR FOR ALL ROOMS | | AND AREAS. | | | | 4) M-1: INDICATE HOW THE LARGE STORAGE ROOM ON THE | | SOUTH SIDE OF THE OCCUPANCY IS BEING VENTILATED- TABLE | | 403.3.1.1 FBC M. | | | | 5) M-1: A MINIMUM 10' CLEARANCE DISTANCE TO THE | | DRIVEWAY IS REQUIRED FOR THE O/A FAN THAT IS PROVIDING | | FAN TO THE ART STORAGE ROOM ON THE NORTH SIDE- SECTION | | 401.4 FBC M. THIS REQUIREMENT WILL REMAIN UNTIL THE | | PLAN ACTUALLY SHOWS THE DRIVEWAY WILL BE REMOVED AND | | CONVERTED TO NON-VEHICULAR USE. | | | | 6) M-1: PROVIDE AN EQUIPMENT SCHEDULE FOR THE ART | | STORAGE FAN AND INDICATE HOW THE NEW WALL OPENING WILL | | PROTECTED AGAINST WIND AND RAIN- SECTION 401.5. PLEASE | | NOTE THAT OUTDOOR AIR INTAKE OPENINGS LOCATED IN | | EXTERIOR WALLS SHALL MEET THE PROVISIONS FOR EXTERIOR | | WALL OPENING PROTECTIVES IN ACCORDANCE WITH THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 7) M-1: THE NEW AIR CONDITIONED DISPLAY AREAS THAT WERE | | PREVIOUSLY LOADING DOCKS ARE DEFINED AS ADDITIONS PER | | SECTION C202 FBC EC. PROVIDE AC LOAD CALCULATIONS IN | | ACCODANCE WITH SECTION C403.2.1 FBC EC. | | | | 8) M-1: NEW ADDITIONS AND SPACES THAT CHANGE OCCUPANCY | | ARE SUBJECT TO COMPLIANCE WITH THE CURRENT FBC EC. | | PLEASE SEE SECTION C101.5.1 AND SUBMIT A COMPLIANCE | | REPORT USIBNG APPROVED SOFTWARE. REFER TO THE FOLLOWING | | SECTIONS FOR MORE INFORMATION - C503.2, C101.3, AND | | C401.2. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. PLEASE NOTE THAT | | SUBMITTAL OF CORRECTED PLANS MAY RESULT IN NEW PLAN | | REVIEW COMMENTS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | HTTPS://WWW.SURVEYMONKEY.COM/R/WESTPALMBEACHCONSTRUCTIO | | NSERVICES | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2019-04-22 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-04-22 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-04-22 |
Time |
11:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-02-28 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-02-28 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-02-28 |
Time |
07:53 |
Sent To |
|
|
Notes |
2019-02-28 11:19:56 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 2ND REVIEW: DENIED | | PLUMBING COMMENTS | | 1. PLAN SHEET P-2.0: | | A. MINIMUM PLUMBING FIXTURE REQUIREMENTS FOR OCCUPANCY | | LOAD 378 MERCANTILE IS INCORRECT. REQUIRES TWO (2) EACH | | TOILETS, TWO (2) EACH LAVATORIES, ONE (1) EACH SERVICE | | SINK AND ONE (1) EACH DRINKING FOUNTAIN PER FBC PL | | TABLE 403.1. CORRECT ON PLANS PER WPB FBC 107.2.1 | | B. EXISTING WOMEN?S TOILET ROOM DOES NOT MEET THE | | REQUIREMENTS OF FBC ACC 604.8.1.7. PLEASE NOTE ADVISORY | | 604.8.1.6 LAVATORY AND 604.8.Y WHICH NOTES THAT THE | | FLORIDA REQUIREMENT ONLY APPLIES TO NEW CONSTRUCTION, | | THEY ARE DESIRABLE FOR ALL WHEELCHAIR ACCESSIBLE | | COMPARTMENTS AND SHOULD BE CONSIDERED WHERE FEASIBLE. | | PER FBC ACC 202.4.1 DISPROPORTIONATE COST UP TO 20% (IN | | THIS CASE $5000.00) OF THE PROJECT COST SHALL BE USED | | TO UPGRADE ACCESSIBILITY REQUIREMENTS. PROVIDE | | COMPLIANCE TO FBC ACC 604.8.1.7 OR SHOW INFEASIBILITY | | OF PROVIDING THE UPGRADE WHICH WOULD INCLUDE BUT NOT BE | | LIMITED TO EXCEEDING THE 20% COST. PROVIDE | | DOCUMENTATION FOR THE SAME PER WPB FBC 107.2.1. | | C. ONE EACH (1) VTR (VENT THROUGH THE ROOF OR TO THE | | OUTSIDE) IS REQUIRED FOR EACH BUILDING DRAIN PER FBC PL | | 904.1. SANITARY RISER DIAGRAM NOTES ONE (1) EACH | | EXISTING VTR/SV ABOVE CEILING AND TWO (2) EACH NEW | | VTR/SV ABOVE CEILING. WHAT IS THE DEFINITION OF THE | | TERM ?SV?. PER WPB FBC 107.2.1, PLEASE CLARIFY ON PLANS | | AND SHOW THAT AT LEAST ONE OF THE VENTS DOES INDEED | | EXTEND TO THE OUTSIDE. | | D. THE WATER CLOSET IS TO BE SUPPLIED WITH COLD WATER | | ONLY FOR FLUSHING PURPOSES. CORRECT ON WATER RISER | | DIAGRAM PER WPB FBC 107.2.1. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN | | ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-09-25 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-09-25 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-09-25 |
Time |
13:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2019-05-20 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2019-05-20 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2019-05-20 |
Time |
11:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-03-14 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2019-03-14 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2019-03-14 |
Time |
09:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-10-30 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2018-10-30 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2018-10-30 |
Time |
10:00 |
Sent To |
|
|
Notes |
2018-10-30 10:35:42 | 1. SCOPE OF WORK ON SHEET CV-1.0 DOES NOT SEEM TO MATCH | | THE BUILDING IN OTHER SHEETS. | | 2. EXISTING GARAGE DOORS ALONG RAILROAD AVENUE CANNOT | | BE REPLACED BY WALLS AS A SOLID WALL WILL INCREASE THE | | EXISTING LEGAL NON-CONFORMITY REGARDING TRANSPARENCY | | ALONG RAILROAD AVENUE. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439 |
|
|