Plan Review Stops For Permit 18030117 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-06-04 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-06-04 |
Time |
15:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2019-01-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-01-16 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-01-16 |
Time |
11:31 |
Sent To |
|
|
Notes |
2019-01-16 11:44:28 | 3RD REVIEW: FBC 2017 5TH EDITION | | FBC 2017 EXISTING BUILDING | | | | 1/16/19 - A NEW DESIGN HAS BEEN SUBMITTED BY A NEW | | DESIGNER. SEE PREVIOUS REVIEWS AND NOTE THE STATUS IS | | SIMILAR TO THE PREVIOUS REVIEW. | | | | TO PROCEED WITH LEGALLY ESTABLISHING THE THIRD UNIT, | | THE APPLICANT MUST NOW DEVELOP A PLAN TO DEMONSTRATE | | COMPLIANCE WITH CURRENT APPLICABLE CODE AS IF CHANGING | | THE LAYOUT ON FILE TO A LEGAL DWELLING UNIT UNDER THE | | REQUIREMENTS OF THE FBC 2017 EXISTING BUILDING CHAPTER | | 10 CHANGE OF OCCUPANCY. THE PLAN MUST SHOW COMPLIANCE | | WITH PLUMBING REGARDING THE CONNECTIONS TO THE KITCHEN | | AS THE BATHROOM IS PRESUMED TO BE EXISTING, COMPLETE | | ELECTRICAL COMPLIANCE FOR THE INTERIOR IN TERMS OF | | REQUIRED ELECTRICAL CIRCUITS, DEVICES AND SMOKE ALARMS, | | ETC; NOTE A RECENT ELECTRICAL PERMIT WAS COMPLETED FOR | | WORK IN THIS AREA, SEE ELECTRICAL PLAN REVIEW. A | | MECHANICAL PLAN FOR REQUIRED HEAT AND ANY PROVIDED | | COOLING, AND AN ENERGY SUBMITTAL. ADDITIONALLY | | COMPLIANCE WITH CHAPTER 9 FBC IS REQUIRED AS TO FIRE | | PROTECTION SYSTEMS INCLUDING INCLUDING FIRE SPRINKLER | | AND FIRE ALARM. THE ARCHITECTURAL PLAN MUST PROVIDE THE | | CODE REFERENCE AND A SCOPE OF WORK DISCUSSING THE | | ATTEMPT TO LEGALIZE EXISTING WORK THROUGH ASSURING THE | | RECONFIGURATION OF THE SPACE COMPLIES WITH THE | | AFOREMENTIONED FBC 2017 EXISTING BUILDING CHAPTER 10 | | CHANGE OF OCCUPANCY. PRIOR TO PERMIT ISSUANCE THE | | APPROVED PLAN WILL NEED TO BE REVIEWED BY THE PBC | | IMPACT FEE OFFICE AND A FEE MAY BE DUE TO THEM. AN | | APPROPRIATE VALE FOR THIS WORK WILL NEED TO BE | | ESTABLISHED. $1,200.00 SEEMS LOW. IF ANY NEW WORK IS TO | | BE DONE, SEPARATE PERMITS PER TRADE WILL BE REQUIRED. | | | | THE SUBMITTED PLAN IS DEFICIENT AND DOES NOT MEET THE | | MINIMUM PLAN REVIEW CRITERIA REQUIRED IN FBC 107 AND | | THE ITEMS LISTED GENERALLY ABOVE. A COMPLETE REIVEW | | CANNOT BE CONDUCTED. PLEASE NOTE THAT ANY REVIEWS | | COMPLETED PRIOR TO THIS DATE AND APPROVED ARE SUBJECT | | TO CHANGE. | | | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-05-18 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-05-18 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-05-18 |
Time |
13:49 |
Sent To |
|
|
Notes |
2018-06-07 08:44:45 | 2ND REVIEW: FBC 2017 5TH EDITION | | FBC 2017 EXISTING BUILDING | | | | UNDER REVIEW | | | | 5/18/18 MET WITH OWNER, EXPLAINED FIRST REVIEW COMMENTS | | OF 4/18/18 WERE NOT SUFFIENTLY ADDRESSED. | | | | FIRST REVIEW COMMENTS SEE BELOW: | | | | AS DISCUSSED WITH ARCHITECT NORM PAUL, I PROVIDED VIA | | EMAIL THE FILE RECORD REGARDING THE BUILDING AT THE | | SUBJECT ADDRESS. IT ESTABLISHES THAT THE SINGLE STORY | | PORTION SHOWN AS A THIRD UNIT ON THE PROPERTY WAS ONLY | | A ROOM WITH A BATHROOM AND A ONE CAR GARAGE IN 1964. | | THERE IS NO PERMIT RECORD ON FILE THAT I CAN FIND TO | | CHANGE THAT AREA OF APPROXIMATELY 605 SF FROM A ROOM | | WITH BATH AND GARAGE TO A DWELLING UNIT. THERE ARE | | RECORDS FOR OTHER WORK SUCH AS RECENT WINDOW, ROOFING | | AND ELECTRICAL UPGRADES. THE WINDOW SERVING THE BEDROOM | | MAY NOT MEET EGRESS REQUIREMENTS. SUCH PERMITS ISSUED | | SEPARATELY DO NOT ALLOW FOR THE LEGAL ESTABLISHMENT OF | | A THIRD UNIT. THE UNIT MAY APPEAR LEGAL BUT AGAIN, THE | | RECORD TO LEGALLY ESTABLISH IT IS NOT APPARENT. THE | | PRESUMPTION IS THAT WORK WAS DONE IN THE PAST WITHOUT | | ALL THE REQUIRED PERMITTING TO PROPERLY AND LEGALLY | | ESTABLISH THE USE OF THE APPARENT THIRD UNIT. I | | PROVIDED THE CONTACT INFORMATION TO THE CUSTOMER FOR | | CRAIG MCPHERSON, CUSTOMER SERVICE ASSOCIATE IN THE | | EVENT THEY MAY WISH TO REQUEST HE CHECK RECORDS TO | | VERIFY MY CONCLUSION. TO PROCEED WITH LEGALLY | | ESTABLISHING THE THIRD UNIT, THE APPLICANT MUST NOW | | DEVELOP A PLAN TO DEMONSTRATE COMPLIANCE WITH CURRENT | | APPLICABLE CODE AS IF CHANGING THE LAYOUT ON FILE TO A | | LEGAL DWELLING UNIT UNDER THE REQUIREMENTS OF THE FBC | | 2017 EXISTING BUILDING CHAPTER 10 CHANGE OF OCCUPANCY. | | THE PLAN MUST SHOW COMPLIANCE WITH PLUMBING REGARDING | | THE CONNECTIONS TO THE KITCHEN AS THE BATHROOM IS | | PRESUMED TO BE EXISTING, COMPLETE ELECTRICAL COMPLIANCE | | FOR THE INTERIOR IN TERMS OF REQUIRED ELECTRICAL | | CIRCUITS, DEVICES AND SMOKE ALARMS, ETC, A MECHANICAL | | PLAN FOR REQUIRED HEAT AND ANY PROVIDED COOLING, AND AN | | ENERGY SUBMITTAL. ADDITIONALLY COMPLIANCE WITH CHAPTER | | 9 FBC IS REQUIRED AS TO FIRE PROTECTION SYSTEMS | | INCLUDING INCLUDING FIRE SPRINKLER AND FIRE ALARM. THE | | ARCHITECTURAL PLAN MUST PROVIDE THE CODE REFERENCE AND | | A SCOPE OF WORK DISCUSSING THE ATTEMPT TO LEGALIZE | | EXISTING WORK THROUGH ASSURING THE RECONFIGURATION OF | | THE SPACE COMPLIES WITH THE AFOREMENTIONED FBC 2017 | | EXISTING BUILDING CHAPTER 10 CHANGE OF OCCUPANCY. PRIOR | | TO PERMIT ISSUANCE THE APPROVED PLAN WILL NEED TO BE | | REVIEWED BY THE PBC IMPACT FEE OFFICE AND A FEE MAY BE | | DUE TO THEM. AN APPROPRIATE VALE FOR THIS WORK WILL | | NEED TO BE ESTABLISHED. $1,200.00 SEEMS LOW. IF ANY NEW | | WORK IS TO BE DONE, SEPARATE PERMITS PER TRADE WILL BE | | REQUIRED. | | | | THE SUBMITTED PLAN IS DEFICIENT AND DOES NOT MEET THE | | MINIMUM PLAN REVIEW CRITERIA REQUIRED IN FBC 107 AND | | THE ITEMS LISTED GENERALLY ABOVE. A COMPLETE REIVEW | | CANNOT BE CONDUCTED. PLEASE NOTE THAT ANY REVIEWS | | COMPLETED PRIOR TO THIS DATE AND APPROVED ARE SUBJECT | | TO CHANGE. | | | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | | | 1ST REVIEW: FBC 2017 5TH EDITION | | 1ST REVIEW FBC 2017 EXISTING BUILDING | | | | | | AS DISCUSSED WITH ARCHITECT NORM PAUL, I PROVIDED VIA | | EMAIL THE FILE RECORD REGARDING THE BUILDING AT THE | | SUBJECT ADDRESS. IT ESTABLISHES THAT THE SINGLE STORY | | PORTION SHOWN AS A THIRD UNIT ON THE PROPERTY WAS ONLY | | A ROOM WITH A BATHROOM AND A ONE CAR GARAGE IN 1964. | | THERE IS NO PERMIT RECORD ON FILE THAT I CAN FIND TO | | CHANGE THAT AREA OF APPROXIMATELY 605 SF FROM A ROOM | | WITH BATH AND GARAGE TO A DWELLING UNIT. THERE ARE | | RECORDS FOR OTHER WORK SUCH AS RECENT WINDOW, ROOFING | | AND ELECTRICAL UPGRADES. THE WINDOW SERVING THE BEDROOM | | MAY NOT MEET EGRESS REQUIREMENTS. SUCH PERMITS ISSUED | | SEPARATELY DO NOT ALLOW FOR THE LEGAL ESTABLISHMENT OF | | A THIRD UNIT. THE UNIT MAY APPEAR LEGAL BUT AGAIN, THE | | RECORD TO LEGALLY ESTABLISH IT IS NOT APPARENT. THE | | PRESUMPTION IS THAT WORK WAS DONE IN THE PAST WITHOUT | | ALL THE REQUIRED PERMITTING TO PROPERLY AND LEGALLY | | ESTABLISH THE USE OF THE APPARENT THIRD UNIT. I | | PROVIDED THE CONTACT INFORMATION TO THE CUSTOMER FOR | | CRAIG MCPHERSON, CUSTOMER SERVICE ASSOCIATE IN THE | | EVENT THEY MAY WISH TO REQUEST HE CHECK RECORDS TO | | VERIFY MY CONCLUSION. TO PROCEED WITH LEGALLY | | ESTABLISHING THE THIRD UNIT, THE APPLICANT MUST NOW | | DEVELOP A PLAN TO DEMONSTRATE COMPLIANCE WITH CURRENT | | APPLICABLE CODE AS IF CHANGING THE LAYOUT ON FILE TO A | | LEGAL DWELLING UNIT UNDER THE REQUIREMENTS OF THE FBC | | 2017 EXISTING BUILDING CHAPTER 10 CHANGE OF OCCUPANCY. | | THE PLAN MUST SHOW COMPLIANCE WITH PLUMBING REGARDING | | THE CONNECTIONS TO THE KITCHEN AS THE BATHROOM IS | | PRESUMED TO BE EXISTING, COMPLETE ELECTRICAL COMPLIANCE | | FOR THE INTERIOR IN TERMS OF REQUIRED ELECTRICAL | | CIRCUITS, DEVICES AND SMOKE ALARMS, ETC, A MECHANICAL | | PLAN FOR REQUIRED HEAT AND ANY PROVIDED COOLING, AND AN | | ENERGY SUBMITTAL. ADDITIONALLY COMPLIANCE WITH CHAPTER | | 9 FBC IS REQUIRED AS TO FIRE PROTECTION SYSTEMS | | INCLUDING INCLUDING FIRE SPRINKLER AND FIRE ALARM. THE | | ARCHITECTURAL PLAN MUST PROVIDE THE CODE REFERENCE AND | | A SCOPE OF WORK DISCUSSING THE ATTEMPT TO LEGALIZE | | EXISTING WORK THROUGH ASSURING THE RECONFIGURATION OF | | THE SPACE COMPLIES WITH THE AFOREMENTIONED FBC 2017 | | EXISTING BUILDING CHAPTER 10 CHANGE OF OCCUPANCY. PRIOR | | TO PERMIT ISSUANCE THE APPROVED PLAN WILL NEED TO BE | | REVIEWED BY THE PBC IMPACT FEE OFFICE AND A FEE MAY BE | | DUE TO THEM. AN APPROPRIATE VALE FOR THIS WORK WILL | | NEED TO BE ESTABLISHED. $1,200.00 SEEMS LOW. IF ANY NEW | | WORK IS TO BE DONE, SEPARATE PERMITS PER TRADE WILL BE | | REQUIRED. | | | | THE SUBMITTED PLAN IS DEFICIENT AND DOES NOT MEET THE | | MINIMUM PLAN REVIEW CRITERIA REQUIRED IN FBC 107 AND | | THE ITEMS LISTED GENERALLY ABOVE. A COMPLETE REIVEW | | CANNOT BE CONDUCTED. PLEASE NOTE THAT ANY REVIEWS | | COMPLETED PRIOR TO THIS DATE AND APPROVED ARE SUBJECT | | TO CHANGE. | | | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-04-17 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-04-17 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-04-17 |
Time |
07:58 |
Sent To |
FIRE |
|
Notes |
2018-05-18 13:54:17 | 2ND REVIEW: FBC 2017 5TH EDITION | | FBC 2017 EXISTING BUILDING | | | | UNDER REVIEW | | | | 5/18/18 MET WITH OWNER, EXPLAINED FIRST REVIEW COMMENTS | | OF 4/18/18 WERE NOT SUFFIENTLY ADDRESSED. | | | | FIRST REVIEW COMMENTS SEE BELOW: | | | | AS DISCUSSED WITH ARCHITECT NORM PAUL, I PROVIDED VIA | | EMAIL THE FILE RECORD REGARDING THE BUILDING AT THE | | SUBJECT ADDRESS. IT ESTABLISHES THAT THE SINGLE STORY | | PORTION SHOWN AS A THIRD UNIT ON THE PROPERTY WAS ONLY | | A ROOM WITH A BATHROOM AND A ONE CAR GARAGE IN 1964. | | THERE IS NO PERMIT RECORD ON FILE THAT I CAN FIND TO | | CHANGE THAT AREA OF APPROXIMATELY 605 SF FROM A ROOM | | WITH BATH AND GARAGE TO A DWELLING UNIT. THERE ARE | | RECORDS FOR OTHER WORK SUCH AS RECENT WINDOW, ROOFING | | AND ELECTRICAL UPGRADES. THE WINDOW SERVING THE BEDROOM | | MAY NOT MEET EGRESS REQUIREMENTS. SUCH PERMITS ISSUED | | SEPARATELY DO NOT ALLOW FOR THE LEGAL ESTABLISHMENT OF | | A THIRD UNIT. THE UNIT MAY APPEAR LEGAL BUT AGAIN, THE | | RECORD TO LEGALLY ESTABLISH IT IS NOT APPARENT. THE | | PRESUMPTION IS THAT WORK WAS DONE IN THE PAST WITHOUT | | ALL THE REQUIRED PERMITTING TO PROPERLY AND LEGALLY | | ESTABLISH THE USE OF THE APPARENT THIRD UNIT. I | | PROVIDED THE CONTACT INFORMATION TO THE CUSTOMER FOR | | CRAIG MCPHERSON, CUSTOMER SERVICE ASSOCIATE IN THE | | EVENT THEY MAY WISH TO REQUEST HE CHECK RECORDS TO | | VERIFY MY CONCLUSION. TO PROCEED WITH LEGALLY | | ESTABLISHING THE THIRD UNIT, THE APPLICANT MUST NOW | | DEVELOP A PLAN TO DEMONSTRATE COMPLIANCE WITH CURRENT | | APPLICABLE CODE AS IF CHANGING THE LAYOUT ON FILE TO A | | LEGAL DWELLING UNIT UNDER THE REQUIREMENTS OF THE FBC | | 2017 EXISTING BUILDING CHAPTER 10 CHANGE OF OCCUPANCY. | | THE PLAN MUST SHOW COMPLIANCE WITH PLUMBING REGARDING | | THE CONNECTIONS TO THE KITCHEN AS THE BATHROOM IS | | PRESUMED TO BE EXISTING, COMPLETE ELECTRICAL COMPLIANCE | | FOR THE INTERIOR IN TERMS OF REQUIRED ELECTRICAL | | CIRCUITS, DEVICES AND SMOKE ALARMS, ETC, A MECHANICAL | | PLAN FOR REQUIRED HEAT AND ANY PROVIDED COOLING, AND AN | | ENERGY SUBMITTAL. ADDITIONALLY COMPLIANCE WITH CHAPTER | | 9 FBC IS REQUIRED AS TO FIRE PROTECTION SYSTEMS | | INCLUDING INCLUDING FIRE SPRINKLER AND FIRE ALARM. THE | | ARCHITECTURAL PLAN MUST PROVIDE THE CODE REFERENCE AND | | A SCOPE OF WORK DISCUSSING THE ATTEMPT TO LEGALIZE | | EXISTING WORK THROUGH ASSURING THE RECONFIGURATION OF | | THE SPACE COMPLIES WITH THE AFOREMENTIONED FBC 2017 | | EXISTING BUILDING CHAPTER 10 CHANGE OF OCCUPANCY. PRIOR | | TO PERMIT ISSUANCE THE APPROVED PLAN WILL NEED TO BE | | REVIEWED BY THE PBC IMPACT FEE OFFICE AND A FEE MAY BE | | DUE TO THEM. AN APPROPRIATE VALE FOR THIS WORK WILL | | NEED TO BE ESTABLISHED. $1,200.00 SEEMS LOW. IF ANY NEW | | WORK IS TO BE DONE, SEPARATE PERMITS PER TRADE WILL BE | | REQUIRED. | | | | THE SUBMITTED PLAN IS DEFICIENT AND DOES NOT MEET THE | | MINIMUM PLAN REVIEW CRITERIA REQUIRED IN FBC 107 AND | | THE ITEMS LISTED GENERALLY ABOVE. A COMPLETE REIVEW | | CANNOT BE CONDUCTED. PLEASE NOTE THAT ANY REVIEWS | | COMPLETED PRIOR TO THIS DATE AND APPROVED ARE SUBJECT | | TO CHANGE. | | | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | | 2018-04-18 11:34:05 | 1ST REVIEW: FBC 2017 5TH EDITION | | 1ST REVIEW FBC 2017 EXISTING BUILDING | | | | | | AS DISCUSSED WITH ARCHITECT NORM PAUL, I PROVIDED VIA | | EMAIL THE FILE RECORD REGARDING THE BUILDING AT THE | | SUBJECT ADDRESS. IT ESTABLISHES THAT THE SINGLE STORY | | PORTION SHOWN AS A THIRD UNIT ON THE PROPERTY WAS ONLY | | A ROOM WITH A BATHROOM AND A ONE CAR GARAGE IN 1964. | | THERE IS NO PERMIT RECORD ON FILE THAT I CAN FIND TO | | CHANGE THAT AREA OF APPROXIMATELY 605 SF FROM A ROOM | | WITH BATH AND GARAGE TO A DWELLING UNIT. THERE ARE | | RECORDS FOR OTHER WORK SUCH AS RECENT WINDOW, ROOFING | | AND ELECTRICAL UPGRADES. THE WINDOW SERVING THE BEDROOM | | MAY NOT MEET EGRESS REQUIREMENTS. SUCH PERMITS ISSUED | | SEPARATELY DO NOT ALLOW FOR THE LEGAL ESTABLISHMENT OF | | A THIRD UNIT. THE UNIT MAY APPEAR LEGAL BUT AGAIN, THE | | RECORD TO LEGALLY ESTABLISH IT IS NOT APPARENT. THE | | PRESUMPTION IS THAT WORK WAS DONE IN THE PAST WITHOUT | | ALL THE REQUIRED PERMITTING TO PROPERLY AND LEGALLY | | ESTABLISH THE USE OF THE APPARENT THIRD UNIT. I | | PROVIDED THE CONTACT INFORMATION TO THE CUSTOMER FOR | | CRAIG MCPHERSON, CUSTOMER SERVICE ASSOCIATE IN THE | | EVENT THEY MAY WISH TO REQUEST HE CHECK RECORDS TO | | VERIFY MY CONCLUSION. TO PROCEED WITH LEGALLY | | ESTABLISHING THE THIRD UNIT, THE APPLICANT MUST NOW | | DEVELOP A PLAN TO DEMONSTRATE COMPLIANCE WITH CURRENT | | APPLICABLE CODE AS IF CHANGING THE LAYOUT ON FILE TO A | | LEGAL DWELLING UNIT UNDER THE REQUIREMENTS OF THE FBC | | 2017 EXISTING BUILDING CHAPTER 10 CHANGE OF OCCUPANCY. | | THE PLAN MUST SHOW COMPLIANCE WITH PLUMBING REGARDING | | THE CONNECTIONS TO THE KITCHEN AS THE BATHROOM IS | | PRESUMED TO BE EXISTING, COMPLETE ELECTRICAL COMPLIANCE | | FOR THE INTERIOR IN TERMS OF REQUIRED ELECTRICAL | | CIRCUITS, DEVICES AND SMOKE ALARMS, ETC, A MECHANICAL | | PLAN FOR REQUIRED HEAT AND ANY PROVIDED COOLING, AND AN | | ENERGY SUBMITTAL. ADDITIONALLY COMPLIANCE WITH CHAPTER | | 9 FBC IS REQUIRED AS TO FIRE PROTECTION SYSTEMS | | INCLUDING INCLUDING FIRE SPRINKLER AND FIRE ALARM. THE | | ARCHITECTURAL PLAN MUST PROVIDE THE CODE REFERENCE AND | | A SCOPE OF WORK DISCUSSING THE ATTEMPT TO LEGALIZE | | EXISTING WORK THROUGH ASSURING THE RECONFIGURATION OF | | THE SPACE COMPLIES WITH THE AFOREMENTIONED FBC 2017 | | EXISTING BUILDING CHAPTER 10 CHANGE OF OCCUPANCY. PRIOR | | TO PERMIT ISSUANCE THE APPROVED PLAN WILL NEED TO BE | | REVIEWED BY THE PBC IMPACT FEE OFFICE AND A FEE MAY BE | | DUE TO THEM. AN APPROPRIATE VALE FOR THIS WORK WILL | | NEED TO BE ESTABLISHED. $1,200.00 SEEMS LOW. IF ANY NEW | | WORK IS TO BE DONE, SEPARATE PERMITS PER TRADE WILL BE | | REQUIRED. | | | | THE SUBMITTED PLAN IS DEFICIENT AND DOES NOT MEET THE | | MINIMUM PLAN REVIEW CRITERIA REQUIRED IN FBC 107 AND | | THE ITEMS LISTED GENERALLY ABOVE. A COMPLETE REIVEW | | CANNOT BE CONDUCTED. PLEASE NOTE THAT ANY REVIEWS | | COMPLETED PRIOR TO THIS DATE AND APPROVED ARE SUBJECT | | TO CHANGE. | | | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
N |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-06-04 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-06-04 |
Time |
14:26 |
Sent To |
|
|
Notes |
2019-06-04 14:26:30 | SEE PERMIT 17071002. WILL NEED AN ADDITIONAL ELECTRICAL | | PERMIT TO FACILITATE MECHANICAL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2019-01-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-01-16 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-01-16 |
Time |
11:35 |
Sent To |
|
|
Notes |
2019-01-16 11:36:11 | NO ELECTRICAL WAS SUBMITTED WITH THIS NEWLY DESIGNED | | PLAN SET. PLEASE SEE THE COMMENTS UNDER THE BUILDING | | REVIEW. | | | | | | ELECTRICAL WORK COMPLETED UNDER PERMIT NUMBER 17071002. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-05-21 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2018-05-21 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2018-05-21 |
Time |
10:29 |
Sent To |
|
|
Notes |
2018-05-21 11:15:24 | PASS 5/21/2018 PHIL PETTY | | CHANGED STATUS TO FAIL ON 4-20-18. NEED TO REVIEW PLAN | | WHEN SUBMITTED. | | | | | | ELECTRICAL WORK COMPLETED UNDER PERMIT NUMBER 17071002. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-04-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-04-20 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-03-09 |
Time |
14:04 |
Sent To |
|
|
Notes |
2018-04-20 14:18:09 | CHANGED STATUS TO FAIL ON 4-20-18. NEED TO REVIEW PLAN | | WHEN SUBMITTED. | | | | | 2018-03-09 14:04:00 | ELECTRICAL WORK COMPLETED UNDER PERMIT NUMBER 17071002. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-06-04 |
Time |
|
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-06-04 |
Time |
14:16 |
Sent To |
|
|
Notes |
2019-06-04 14:18:36 | DISCUSSED WITH CHIEF LEDUC, SEE 19011123 & 19020268. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
F |
Date |
2018-12-06 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-12-06 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-12-06 |
Time |
09:38 |
Sent To |
|
|
Notes |
2018-12-06 09:40:28 | PERMIT # 18030117 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | 3RD REVIEW - FAIL COMMENTS | | | | 1) REPEAT COMMENT (3RD TIME): PER NFPA 101, CHAPTER 30 | | - NEW APARTMENTS | | 30.3.5.1: ALL BUILDINGS SHALL BE PROTECTED THROUGHOUT | | BY AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM. | | PLEASE PROVIDE DRAWING NOTE INDICATING COMPLIANCE OF | | THIS REQUIREMENT, OR PROVIDE JUSTIFICATION. | | | | 2) REPEAT COMMENT (2ND TIME): A 1-HOUR FIRE RATED | | SEPERATION IS PROVIDED BETWEEN THE TWO BOTTOM UNITS, | | HOWEVER THE SEPERATION BETWEEN THE TOP AND BOTTOM UNITS | | IS NOT PROVIDED. | | PLEASE PROVIDE THE SEPERATION, IF ANY, BETWEEN THE TOP | | AND BOTTOM UNITS. | | | | 3) SHEETS A-1 & A-2: THE FIRE RATED WALL IS MARKED AND | | IDENTIFIED, HOWEVER, THE FIRE RATING FOR THE FLOOR THAT | | SEPERATES THE TOP AND BOTTOM STORIES IS NOT PROVIDED. | | | | 4) A LAWN SPRINKLER DRAWING IS PROVIDED, HOWEVER THIS | | DOES NOT APPLY TO COMMENT #1. A LAWN SPRINKLER SYSTEM | | IS NOT THE SAME AS A FIRE SPRINKLER SYSTEM. | | | | | | THANK YOU, | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 804-4751 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2018-05-07 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-05-07 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-05-07 |
Time |
13:40 |
Sent To |
|
|
Notes |
2018-05-07 14:48:48 | PERMIT # 18030117 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | 2ND REVIEW - | | | | 1) REPEAT COMMENT: PER NFPA 101, CHAPTER 30 - NEW | | APARTMENTS | | 30.3.5.1: ALL BUILDINGS SHALL BE PROTECTED THROUGHOUT | | BY AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM. | | PLEASE PROVIDE DRAWING NOTE INDICATING COMPLIANCE OF | | THIS REQUIREMENT, OR PROVIDE JUSTIFICATION. | | | | 2) A 1-HOUR FIRE RATED SEPERATION IS PROVIDED BETWEEN | | THE TWO BOTTOM UNITS, HOWEVER THE SEPERATION BETWEEN | | THE TOP AND BOTTOM UNITS IS NOT PROVIDED. | | PLEASE PROVIDE THE SEPERATION, IF ANY, BETWEEN THE TOP | | AND BOTTOM UNITS. | | | | | | THANK YOU, | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 804-4751 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2018-04-23 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-04-23 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-04-23 |
Time |
10:59 |
Sent To |
I |
|
Notes |
2018-04-23 11:03:29 | PERMIT # 18030117 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | FAILED COMMENTS: | | | | 1) PER NFPA 101, CHAPTER 30 - NEW APARTMENTS | | 30.3.5.1: ALL BUILDINGS SHALL BE PROTECTED THROUGHOUT | | BY AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM. | | | | 2) HARD-WIRED MULTI-STATION SMOKE ALARMS SHALL BE | | INSTALLED ON ALL LEVELS OF THE DWELLING UNIT, INSIDE | | EACH BEDROOM AND DIRECTLY OUTSIDE BEDROOM DOORS. | | | | 3) PLEASE REVIEW AND COMPLY WITH ALL OTHER PLAN REVIEW | | COMMENTS. | | | | | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-06-04 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-04-26 |
Time |
14:50 |
Sent To |
|
|
Notes |
2019-04-29 14:50:33 | RESUB ROTUED TO SKENNEDY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-01-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-01-16 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-11-29 |
Time |
14:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-06-06 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-06-06 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-05-01 |
Time |
09:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-04-17 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-04-23 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-03-05 |
Time |
15:50 |
Sent To |
|
|
Notes |
2018-04-09 14:19:07 | R16 | 2018-03-21 07:15:21 | 3/21/18 REMOVED FROM REVIEW; A THIRD UNIT IS NOT | | PERMITTED, SEE ZONING REVIEW. | | PLAN HAS BEEN SCANNED AND ADDED AS AN ATTACHMENT TO | | THIS PERMT RECORD. | | | | | 2018-03-06 15:50:33 | R14 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-06-04 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-06-04 |
Time |
14:26 |
Sent To |
|
|
Notes |
2019-06-04 14:27:38 | MU 2019-012671-0000 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-04-17 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-04-17 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-04-17 |
Time |
07:58 |
Sent To |
|
|
Notes |
2018-04-18 15:19:10 | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
N |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-06-04 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-06-04 |
Time |
14:46 |
Sent To |
|
|
Notes |
2019-06-04 14:47:23 | SEE PERMIT 19051564. USED NEXT AVAILABLE SIZE VS. | | REQUIRED COOLING CAPACITY. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2019-01-16 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-01-16 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-01-16 |
Time |
11:32 |
Sent To |
|
|
Notes |
2019-01-16 12:20:38 | 3RD REVIEW: FBC 2017 5TH EDITION | | FBC 2017 EXISTING BUILDING | | | | THE RESUBMITTED PLAN INDICATES ONLY GENERALLY, THE USE | | OF A WINDOW CONDITIONING UNIT. | | | | PLEASE SEE FIRST REVIEW COMMENTS BELOW. | | | | PROVIDE AND ENERY SUBMITTAL, AND MECHANICAL PLAN PER | | FBC 107. NO REVIEW CAN BE CONDUCTED AS NOTHING IS | | PROVIDED. | | | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2018-05-18 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-05-18 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-05-18 |
Time |
15:05 |
Sent To |
|
|
Notes |
2018-05-18 15:08:22 | 2ND REVIEW: FBC 2017 5TH EDITION | | FBC 2017 EXISTING BUILDING | | | | THE RESUBMITTED PLAN INDICATES ONLY GENERALLY, THE USE | | OF A WINDOW CONDITIONING UNIT. | | | | PLEASE SEE FIRST REVIEW COMMENTS BELOW. | | | | PROVIDE AND ENERY SUBMITTAL, AND MECHANICAL PLAN PER | | FBC 107. NO REVIEW CAN BE CONDUCTED AS NOTHING IS | | PROVIDED. | | | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-04-17 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-04-17 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-04-17 |
Time |
07:58 |
Sent To |
|
|
Notes |
2018-04-18 15:22:46 | 1ST REVIEW: FBC 2017 5TH EDITION | | 1ST REVIEW FBC 2017 EXISTING BUILDING | | | | PROVIDE AND ENERY SUBMITTAL, AND MECHANICAL PLAN PER | | FBC 107. NO REVIEW CAN BE CONDUCTED AS NOTHING IS | | PROVIDED. | | | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-06-04 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-06-04 |
Time |
15:36 |
Sent To |
|
|
Notes |
2019-06-04 15:38:03 | IRRIGATION ONLY REVIEW BY GEORGE JOHNSON. SEPARATE | | APPLICATION REQUIRED & SEPARATE BACKFLOW REQUIRED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
N |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-06-04 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-06-04 |
Time |
14:29 |
Sent To |
|
|
Notes |
2019-06-04 14:30:00 | SEE 18080900 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2019-01-08 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-01-08 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-01-08 |
Time |
17:08 |
Sent To |
|
|
Notes |
2019-01-08 17:08:04 | 3ND REVIEW: FBC 2017 6TH EDITION | | | | IT IS UNCLEAR WHAT NEW PLUMBING WORK WAS DONE IN ORDER | | TO CLARIFY WHAT WAS DONE I AM REQUESTING A MEETING BE | | SCHEDULED SEE CONTACT INFORMATION BELOW, WITHOUT | | CLARIFICATION A PERMIT WILL NOT BE APPROVED. | | | | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED 3RD | | REQUEST | | | | 1. PROVIDE A CODE COMPLIANT SANITARY ISOMETRIC DRAWING. | | PER WPB AMEND TO FBC 107.3.5.1.3 | | | | 3. PLACE NOTE ON PLAN PIPES MAY NEED TO BE EXPOSED FOR | | INSPECTION UP TO THE DISCRETION OF THE FIELD INSPECTOR. | | PER FBC PL 312 | | | | PREVIOUS COMMENTS 2ND REQUEST | | | | 1. THE LAVATORY,S NOT NOT APPEAR TO HAVE THE REQUIRED | | 21" INFRONT OF FIXTURE PER FBC PL 405.3.1 | | | | 2. SHT. A.02 THE PIPING FOR THE NEW KITCHEN SHALL NOT | | CONNECT TO THE WET VENT OF THE BATHROOM PER FBC PL | | 912.1 | | | | 3. PLEASE INDICATE ON THE PLAN LOCATION OF THE WATER | | HEATER AND MARK THE FIXTURE AS NEW OR EXISTING. PER WPB | | AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-06-06 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-06-06 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-06-06 |
Time |
11:14 |
Sent To |
|
|
Notes |
2018-06-06 14:13:14 | 2ND REVIEW: FBC 2017 6TH EDITION | | | | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED | | | | 1. PROVIDE A CODE COMPLIANT SANITARY ISOMETRIC DRAWING. | | PER WPB AMEND TO FBC 107.3.5.1.3 | | | | 3. PLACE NOTE ON PLAN PIPES MAY NEED TO BE EXPOSED FOR | | INSPECTION UP TO THE DISCRETION OF THE FIELD INSPECTOR. | | PER FBC PL 312 | | | | NEW COMMENTS: | | | | 1. THE LAVATORY,S NOT NOT APPEAR TO HAVE THE REQUIRED | | 21" INFRONT OF FIXTURE PER FBC PL 405.3.1 | | | | 2. SHT. A.02 THE PIPING FOR THE NEW KITCHEN SHALL NOT | | CONNECT TO THE WET VENT OF THE BATHROOM PER FBC PL | | 912.1 | | | | 3. PLEASE INDICATE ON THE PLAN LOCATION OF THE WATER | | HEATER AND MARK THE FIXTURE AS NEW OR EXISTING. PER WPB | | AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-04-10 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-04-10 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-04-10 |
Time |
09:54 |
Sent To |
|
|
Notes |
2018-04-10 11:26:15 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. PROVIDE A CODE COMPLIANT SANITARY ISOMETRIC DRAWING. | | PER WPB AMEND TO FBC 107.3.5.1.3 | | | | 2. PROVIDE DIMENSIONS FOR BATHROOMS TO SHOW COMPLIANCE | | WITH FBC PL 405.3.1 | | | | 3. PLACE NOTE ON PLAN PIPES MAY NEED TO BE EXPOSED FOR | | INSPECTION UP TO THE DISCRETION OF THE FIELD INSPECTOR. | | PER FBC PL 312 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2019-06-04 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2019-06-04 |
Time |
|
Sent To |
|
|
Notes |
2019-06-04 15:20:07 | APPROVAL PER ANGELLA JONES-VANN TO MAKE THIRD UNIT | | LEGAL. | | | | ALANA WOOTEN | | ASSOCIATE PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] | 2019-01-16 11:33:41 | SKIPPED THIS STOP AS BUILDING REVIEW RESPONSE IS THE | | MAIN ISSUE NEEDING RE-SUBMTTAL. SAK |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2018-05-10 |
|
|
Cont ID |
|
Sent By |
AW |
Date |
2018-05-10 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2018-05-10 |
Time |
|
Sent To |
|
|
Notes |
2018-05-10 11:10:09 | ********************************ZONING | | NOTE************************************ | | | | ZONING PASSED PER THE ZONING ADMINISTRATOR, ANGELLA | | VANN. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-03-22 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2018-03-22 |
Time |
|
Sent To |
|
|
Notes |
2018-03-22 12:49:10 | ********************************ZONING | | NOTE************************************ | | | | ZONING PASSED PER THE ZONING ADMINISTRATOR, ANGELLA | | VANN. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
AW |
Date |
2018-03-20 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2018-03-20 |
Time |
|
Sent To |
|
|
Notes |
2018-03-20 13:59:05 | ********************************************ZONING | | REVIEW FAILED********************************* | | | | THE THIRD UNIT IS NOT PERMITTED. PERMIT HISTORY SHOWS | | ONLY 2 UNITS AND CURRENT ZONING IS A SINGLE FAMILY | | DISTRICT. | | | | ALANA WOOTEN | | ASSOICATE PLANNER | | 561-822-1449 | | [email protected] |
|
|