Plan Review Details - Permit 18030102
Plan Review Stops For Permit 18030102
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2018-03-29 Cont ID  
Sent By cthroop Date 2018-03-29 Time 15:29 Rev Time 0.00
Received By cthroop Date 2018-03-29 Time 15:29 Sent To  
Notes
2018-03-29 15:30:32THE ADDRESS FOR THIS STRUCTURE IS 225 GREENWOOD. THE
 REAR STRUCTURE SHOULD BE 227 GREENWOOD.
2018-03-02 16:42:01EVALUATE FOR GREENWOO DRIVE ADDRESS

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-06-11 Cont ID  
Sent By cthroop Date 2018-06-11 Time 17:12 Rev Time 0.00
Received By cthroop Date 2018-06-07 Time 16:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-05-01 Cont ID  
Sent By cthroop Date 2018-05-01 Time 13:38 Rev Time 0.00
Received By cthroop Date 2018-05-01 Time 12:15 Sent To  
Notes
2018-05-01 13:39:04BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE PRODUCT APPROVALS FOR ROOF SYSTEM COMPONENTS
 OR YOU MAY CHOOSE TO DEFER THESE SUBMITTAL UNTIL A
 LATER DATE.
 2. DESIGNER TO LIST SUBMITTALS TO BE DEFERRED ON
 CONSTRUCTION DOCUMENTS.
  
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-03-29 Cont ID  
Sent By CTHROOP Date 2018-03-29 Time 15:35 Rev Time 0.00
Received By cthroop Date 2018-03-28 Time 08:12 Sent To  
Notes
2018-03-29 15:56:00BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PALM BEACH COUNTY IMPACT FEES MAY BE REQUIRED.
 ADDITIONAL 58 SQ. FT. UNDER AIR.
 2. ROOFING PERMIT REQUIRED. PROVIDE PRODUCT APPROVALS
 FOR PROPOSED ROOF SYSTEM COMPONENTS.
 3. PLAN PAGE 7 SHOWS TWO OPTIONS FOR INSULATION, R-30
 BATT OR SPRAYED FOAM. IF OWNER CHOOSES THE SPRAYED FOAM
 SYSTEM, PROVIDE AN ICC-ES REPORT FOR THE PRODUCT TO BE
 INSTALLED.
 4. PLAN PAGE 4 SHOWS A FLAIRED STAIR TREAD AT THE
 BOTTOM OF THE NEW STAIRS. STAIR TREADS SHALL COMPLY
 WITH FBCR311.7.5.2.
 5. PLANS DO NOT PROVIDE DEMENSIONS FOR STAIR LANDING.
 STAIR LANDINGS SHALL COMPLY WITH FBCR311.7.L6. LANDINGS
 SHALL BE A MINIMUM OF 36" IN THE DIRECTION OF TRAVEL.
 6. PLAN PAGE 7 SHOWS STAIR HANDRAIL MHEIGHT TO BE 36"
 -38". HANDRAIL HEIGHT MAY BE BETWEEN 34" - 38" PER
 FBCR311.7.8.
 7. PLANS DO NOT SHOW DEMENSIONS FOR STAIRWAY WIDTH.
 STAIRWAY WIDTH SHALL COMPLY WITH FBCR 311.7.1.
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.
  
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 R311.7.5.2 TREADS.
 THE MINIMUM TREAD DEPTH SHALL BE 10 INCHES (254 MM).
 THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN
 THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF
 ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD?S
 LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN ANY
 FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE
 THAN 3/8 INCH (9.5 MM).
  
 R311.7.6 LANDINGS FOR STAIRWAYS.
 THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM
 OF EACH STAIRWAY. THE MINIMUM WIDTH PERPENDICULAR TO
 THE DIRECTION OF TRAVEL SHALL BE NO LESS THAN THE WIDTH
 OF THE FLIGHT SERVED. LANDINGS OF SHAPES OTHER THAN
 SQUARE OR RECTANGULAR SHALL BE PERMITTED PROVIDED THE
 DEPTH AT THE WALK LINE AND THE TOTAL AREA IS NOT LESS
 THAN THAT OF A QUARTER CIRCLE WITH A RADIUS EQUAL TO
 THE REQUIRED LANDING WIDTH. WHERE THE STAIRWAY HAS A
 STRAIGHT RUN, THE MINIMUM DEPTH IN THE DIRECTION OF
 TRAVEL SHALL BE NOT LESS THAN 36 INCHES (914 MM).
  
 R311.7.8 HANDRAILS.
 HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF
 EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR
 MORE RISERS. R311.7.8.
 HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED
 PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF
 RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM)
 AND NOT MORE THAN 38 INCHES (965 MM). R311.7.8.1 HEIGHT
  
 R311.7.1 WIDTH.
 STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES (914 MM) IN
 CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL
 HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT.
 HANDRAILS SHALL NOT PROJECT MORE THAN 4.5 INCHES (114
 MM) ON EITHER SIDE OF THE STAIRWAY AND THE MINIMUM
 CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL
 HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL NOT BE
 LESS THAN 311/2 INCHES (787 MM) WHERE A HANDRAIL IS
 INSTALLED ON ONE SIDE AND 27 INCHES (698 MM) WHERE
 HANDRAILS ARE PROVIDED ON BOTH SIDES.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-04-25 Cont ID  
Sent By ppetty Date 2018-04-25 Time 11:54 Rev Time 0.00
Received By ppetty Date 2018-04-25 Time 11:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-03-12 Cont ID  
Sent By jpearson Date 2018-03-12 Time 15:26 Rev Time 0.00
Received By jpearson Date 2018-03-12 Time 12:51 Sent To  
Notes
2018-03-12 15:26:29CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PLAN SHOWS A CARBON MONOXIDE ALARM ON SECOND FLOOR
 IN HALLWAY. IN ADDITION TO THE CO ALARM, A SMOKE ALARM
 IS REQUIRED IN THIS LOCATION. ADDITIONALLY, THE
 DOWNSTAIRS BEDROOM SHOULD HAVE A SMOKE ALARM INSIDE THE
 BEDROOM AS WELL AS A SMOKE/CO ALARM WITHIN 10 FEET OF
 THE BEDROOM, PROVIDE CORRECTION. FBC RE R314.3, R315.1
 2. PLAN SHOWS A MAIN DISCONNECT ON THE OUTSIDE OF A
 HOME, FEEDING AN INTERIOR PANEL. THE CONDUCTORS TO
 INTERIOR PANEL SHOULD INCLUDE AN EQUIPMENT GROUNDING
 CONDUCTOR. PROVIDE CORRECTION. NEC 250.122; FBC RE
 E3704.6, 3607.3.1
 3. PLAN SHOWS A STANDARD RECESS LIGHT OVER MASTER TUB.
 LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE SUITABLE
 FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC 410.10(D);
 FBC RE E4003.11
 4. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS. SECOND A/C SYSTEM IS NOT INCLUDED. DEMAND
 FACTORS ARE NOT APPLIED PROPERLY. SUB-PANEL LOAD IS
 SHOWN AS 12.0 KW IN MAIN PANEL, BUT AS 4.5 KW IN
 SUB-PANEL. CLARIFY AND/OR CORRECT. SEE FBC RE FOR
 FORMAT. NEC 220; FBC RE E3602.2
 5. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE
 PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH
 CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE
 CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4
 6. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10
 7. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS,
 DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD
 SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND
 SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN
 THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE
 INDICATING THE REQUIRED SEPARATE PERMITS AND DATA
 SPECIFICATION SHEET SUBMITTALS FOR ANY OF THESE SYSTEMS
 PRESENT. FBC 105.1, 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2018-05-08 Cont ID  
Sent By mgonzale Date 2018-05-08 Time 13:46 Rev Time 0.00
Received By mgonzale Date 2018-05-08 Time 13:46 Sent To  
Notes
2018-05-08 13:47:33OWNERS HAVE COMPLIED WITH THE UNITY OF TITLE
 APPLICATION.
  
 MANNY GONZALEZ
 SENIOR ENGINEERING PROJECT COORDINATOR
 PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2018-04-30 Cont ID  
Sent By shill Date 2018-04-30 Time 08:10 Rev Time 0.00
Received By shill Date 2018-04-30 Time 08:10 Sent To  
Notes
2018-04-30 08:11:43PER ENGINEERING: UNITY OF TITLE REQUIRED
 PLEASE ADVISE ([email protected]) WHEN THIS IS FILED WITH
 THE PALM BEACH COUNTY CLERK'S OFFICE AND ENGINEERING
 REVIEW WILL BE PASSED AT THAT TIME.
  
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2018-04-10 Cont ID  
Sent By shill Date 2018-04-10 Time 13:44 Rev Time 0.00
Received By mgonzale Date 2018-04-10 Time 13:43 Sent To  
Notes
2018-04-10 13:44:30PER ENGINEERING: UNITY OF TITLE REQUIRED
  
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200
  
2018-03-02 16:41:06EVALUATE FOR UNITY OF TITLE WITH REAR PARCEL,

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2018-05-23 Cont ID  
Sent By fmittner Date 2018-05-23 Time 11:56 Rev Time 0.00
Received By fmittner Date 2018-05-23 Time 11:56 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2018-04-18 Cont ID  
Sent By fmittner Date 2018-04-18 Time 15:30 Rev Time 0.00
Received By fmittner Date 2018-04-18 Time 15:29 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-03-08 Cont ID  
Sent By fmittner Date 2018-03-08 Time 10:06 Rev Time 0.00
Received By fmittner Date 2018-03-08 Time 10:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-06-11 Cont ID  
Sent By cthroop Date 2018-06-11 Time 17:12 Rev Time 0.00
Received By cthroop Date 2018-05-11 Time 14:53 Sent To I
Notes
2018-05-14 14:54:05R21

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-05-01 Cont ID  
Sent By cthroop Date 2018-05-01 Time 13:39 Rev Time 0.00
Received By cthroop Date 2018-04-11 Time 12:13 Sent To I
Notes
2018-04-12 12:18:10R21

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-04-10 Cont ID  
Sent By shill Date 2018-04-10 Time 13:44 Rev Time 0.00
Received By shill Date 2018-03-02 Time 10:10 Sent To  
Notes
2018-04-09 07:35:064/9 ON SH DESK
  
2018-03-06 10:10:42R08

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2018-05-01 Cont ID  
Sent By cthroop Date 2018-05-01 Time 13:33 Rev Time 0.00
Received By cthroop Date 2018-05-01 Time 13:33 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-03-29 Cont ID  
Sent By cthroop Date 2018-03-29 Time 15:30 Rev Time 0.00
Received By cthroop Date 2018-03-29 Time 14:26 Sent To  
Notes
2018-03-29 15:32:07BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THERE IS AN INCREASE OF 58 SQ. FT. UNDER AIR.
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2018-05-29 Cont ID  
Sent By hmoser Date 2018-05-29 Time 13:43 Rev Time 0.00
Received By hmoser Date 2018-05-29 Time 13:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2018-04-19 Cont ID  
Sent By cmontell Date 2018-04-19 Time 13:56 Rev Time 0.00
Received By cmontell Date 2018-04-19 Time 13:44 Sent To  
Notes
2018-04-19 13:56:01PLAN DENIED
 1) PROVIDE A/C EQUIPMENT SCHEDULE ON PLAN.
 PER SECTION 107 FBC. 2017.
 2) PROVIDE DUCT SIZE AND CFM ON
 DUCT IN DRESSING ROOM
 3) REFER TO SECTION 107.2.1 ALL INFORMATION
 DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN.
  
 CHRIS MONTELLO
 561-805-6733
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-04-09 Cont ID  
Sent By hmoser Date 2018-04-09 Time 09:16 Rev Time 0.00
Received By hmoser Date 2018-04-09 Time 08:33 Sent To  
Notes
2018-04-09 09:16:28PLAN DENIED
 1) PROVIDE EQUIPMENT SCHEDULE ON PLAN.
 PER SECTION 107 FBC. 2017.
 2) PROVIDE DUCT SIZE AND CFM ON
 DUCT IN DRESSING ROOM
 3) REFER TO SECTION 107.2.1 ALL INFORMATION
 DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-06-04 Cont ID  
Sent By thunt Date 2018-06-04 Time 06:58 Rev Time 0.00
Received By thunt Date 2018-06-04 Time 06:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-04-20 Cont ID  
Sent By thunt Date 2018-04-20 Time 07:10 Rev Time 0.00
Received By thunt Date 2018-04-20 Time 07:10 Sent To  
Notes
2018-04-20 07:16:3504/20/2018 2ND PLUMBING REVIEW**DEINED**
  
 1) LAV SINK ON 1ST FLOOR SHOWING ON SANITARY RISER
 ISOMETRIC SHALL NOT CONNECT INTO THE STACK THAT
 RECEIVESDISCHARGE FROM A TOILET. FBC-R P 3109.2 LAV
 SINK DOES NOT SHOW ON FLOOR PLAN.
  
 2) 2ND FLOOR GUEST BATHRROM ONLY 1 WET VENTED FIXTURE
 IS PERMITTED BEYOND THE VENT. FBC-R P3108.2.1
  
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-03-22 Cont ID  
Sent By lcrespo Date 2018-03-22 Time 17:49 Rev Time 0.00
Received By lcrespo Date 2018-03-22 Time 15:00 Sent To  
Notes
2018-03-22 17:52:1703/22/2018 1ST REVIEW**DENIED**
  
 ON P-3 RISER DIAGRAM, 1 ST FLOOR BATHROOM GROUP CANNOT
 RUN ON THE MAIN TRUNK LINE, SHOW IT AS A BRANCH AND OR
 A AVV, REVENT OR VENT IT OUTSIDE THE UNIT AND DO THE
 SAME FOR THE SECOND FLOOR. FBC R 3104.6 VENT FOR FUTURE
 FIXTURES.
  
 ROMAN TUB REQUIRES A THERMOSTATIC VALVE IN AN
 ACCESSIBLE LOCATION IF SHALL COMPLY WITH ASSE 1017 FBC
 R 2724.1 TEMPERATURE-ACTUATED MIXING VALVES.
  
 PLEASE SHOW WHERE A THERMAL EXPANSION DEVICE IS LOCATED
 FBC R2903.4 THERMAL EXPANSION CONTROL.
  
 THE PLAN SHOWS A POOL AND A SEPARATE BACKFLOW
 PREVENTION DEVICE MAY BE REQUIRED DEPENDING ON FACTORS
 LIKE A POOL FILL AND INSTALLED BY A LICENSED CONTRACTOR
 WITH A SEPARATE APPLICATION AND INSPECTION. FBC R
 2902.3 BACKFLOW PROTECTION.
 REFER TO THE ITEM BELOW FOR COMPLIANCE
 A. A SITE PLAN DEPICTING THE GENERAL LOCATION OF THE
 PROPOSED BACKFLOW PREVENTION DEVICE.
 B. TWO COPIES OF THE MANUFACTURER?S SPECIFICATIONS FOR
 THE BACKFLOW PREVENTER. THE MAKE, MODEL, AND SIZE OF
 THE DEVICE SHALL BE LISTED IN THE DESCRIPTION OF WORK
 SECTION ON THE PERMIT APPLICATION.
 C. DOCUMENTATION THAT THE PROPOSED DEVICE IS LEAD-FREE.
 D. DOCUMENTATION THAT THE PROPOSED BACKFLOW DEVICE IS
 ON THE APPROVED DEVICE LIST PUBLISHED BY THE UNIVERSITY
 OF SOUTHERN CALIFORNIA (USC). PLEASE CONTACT DEPARTMENT
 OF PUBLIC UTILITY FIELD CUSTOMER SERVICE AT
 561-822-2240 FOR DOCUMENTED CONFIRMATION THAT THE
 PROPOSED BACKFLOW PREVENTION DEVICE COMPLIES WITH CITY
 REQUIREMENTS.
 E. BACKFLOW PREVENTER REQUIRED PER THE CITY OF WEST
 PALM BEACH ORD #2853-95. A PERMIT REQUIRED BY A
 LICENSED CONTRACTOR AND MUST BE CERTIFIED BY UTILITIES
 PRIOR TO FINAL INSPECTION. PLEASE CONTACT CITY OF WPB
 UTILITIES AT 561-822-2240 FOR FURTHER DIRECTIONS.
  
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FORM A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS AND GAS RISER THAT REFLECTS THE
 ENTIRE SCOPE OF GAS WORK TO BE DONE. AT THIS TIME. A
 SEPARATE GAS PERMIT REQUIRED AND A GAS RISER DIAGRAM
 REQUIRED. A NOTE CAN THAT PUT ON PLANS THAT SUBMITTAL
 FOR PRODUCT APPROVAL WILL BE SUBMITTED FOR APPLIANCES
 AND ALL GAS RELATED DOCUMENT. WPB AMENDMENTS TO THE FBC
 SEC. 107.3.5.3 (12) RESIDENTIAL GAS
 REFER TO THE ITEM BELOW FOR COMPLIANCE
 A. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL
 CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER
 FBC-2017 FUEL GAS, SECS. 402.4.1, 402.4.2.
 B. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS
 STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
 C. TYPE OF GAS, (LP OR NATURAL).
 D. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON
 THE SYSTEM. REFER TO THE FBC-2017 FBC FUEL GAS RES.
 SEC. G2413.
 E. SUBMIT CALCULATIONS FOR COMBUSTION AIR FOR STOVE PER
 THE FBC-2017 FUEL GAS CODE SEC. 304.
 F. SHOW THE DISTANCE FROM THE POINT OF DELIVERY,
 (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING
 AND/OR SYSTEM PER THE FBC-2017 FUEL GAS APPENDIX A ?
 USE OF CAPACITY SECTION A.3.1(4) & INDICATE THE
 DELIVERY PRESSURE (PSI) PER FBC-2017 FUEL GAS SEC.
 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 G. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL
 GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA
 54, NFPA 58, AND FBC-2017 FUEL GAS SEC. 402.2
  
 ALL PLUMBING MUST COMPLY WITH FLORIDA BUILDING CODE
 2017 6TH EDITION.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 [email protected]
 561-805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2018-06-11 Cont ID  
Sent By cthroop Date 2018-06-11 Time 17:12 Rev Time 0.00
Received By cthroop Date 2018-06-07 Time 16:08 Sent To  
Notes
2018-06-11 17:12:54ROOFING SUBMITTALS TO BE DEFERRED. CT

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2018-05-01 Cont ID  
Sent By cthroop Date 2018-05-01 Time 13:33 Rev Time 0.00
Received By cthroop Date 2018-05-01 Time 12:16 Sent To  
Notes
2018-05-01 13:37:14BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE PRODUCT APPROVALS FOR ROOF SYSTEM COMPONENTS
 OR YOU MAY CHOOSE TO DEFER THESE SUBMITTAL UNTIL A
 LATER DATE.
 2. DESIGNER TO LIST SUBMITTALS TO BE DEFERRED ON
 CONSTRUCTION DOCUMENTS.
  
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2018-03-29 Cont ID  
Sent By cthroop Date 2018-03-29 Time 15:32 Rev Time 0.00
Received By cthroop Date 2018-03-29 Time 14:25 Sent To  
Notes
2018-03-29 15:33:56 
 BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED.
 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOF SYSTEM
 COMPONENTS.
  
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-05-23 Cont ID  
Sent By fmittner Date 2018-05-23 Time 11:56 Rev Time 0.00
Received By fmittner Date 2018-05-23 Time 11:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-03-08 Cont ID  
Sent By fmittner Date 2018-03-08 Time 10:06 Rev Time 0.00
Received By fmittner Date 2018-03-08 Time 10:06 Sent To  
Notes
***NONE***