Plan Review Stops For Permit 18030102 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
N |
Date |
2018-03-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-29 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-29 |
Time |
15:29 |
Sent To |
|
|
Notes |
2018-03-29 15:30:32 | THE ADDRESS FOR THIS STRUCTURE IS 225 GREENWOOD. THE | | REAR STRUCTURE SHOULD BE 227 GREENWOOD. | 2018-03-02 16:42:01 | EVALUATE FOR GREENWOO DRIVE ADDRESS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-06-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-06-11 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-06-07 |
Time |
16:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-05-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-05-01 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-05-01 |
Time |
12:15 |
Sent To |
|
|
Notes |
2018-05-01 13:39:04 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE PRODUCT APPROVALS FOR ROOF SYSTEM COMPONENTS | | OR YOU MAY CHOOSE TO DEFER THESE SUBMITTAL UNTIL A | | LATER DATE. | | 2. DESIGNER TO LIST SUBMITTALS TO BE DEFERRED ON | | CONSTRUCTION DOCUMENTS. | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | SUBMITTALS. | | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | THE DEFERRED SUBMITTALS ON | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-03-29 |
|
|
Cont ID |
|
Sent By |
CTHROOP |
Date |
2018-03-29 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-28 |
Time |
08:12 |
Sent To |
|
|
Notes |
2018-03-29 15:56:00 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PALM BEACH COUNTY IMPACT FEES MAY BE REQUIRED. | | ADDITIONAL 58 SQ. FT. UNDER AIR. | | 2. ROOFING PERMIT REQUIRED. PROVIDE PRODUCT APPROVALS | | FOR PROPOSED ROOF SYSTEM COMPONENTS. | | 3. PLAN PAGE 7 SHOWS TWO OPTIONS FOR INSULATION, R-30 | | BATT OR SPRAYED FOAM. IF OWNER CHOOSES THE SPRAYED FOAM | | SYSTEM, PROVIDE AN ICC-ES REPORT FOR THE PRODUCT TO BE | | INSTALLED. | | 4. PLAN PAGE 4 SHOWS A FLAIRED STAIR TREAD AT THE | | BOTTOM OF THE NEW STAIRS. STAIR TREADS SHALL COMPLY | | WITH FBCR311.7.5.2. | | 5. PLANS DO NOT PROVIDE DEMENSIONS FOR STAIR LANDING. | | STAIR LANDINGS SHALL COMPLY WITH FBCR311.7.L6. LANDINGS | | SHALL BE A MINIMUM OF 36" IN THE DIRECTION OF TRAVEL. | | 6. PLAN PAGE 7 SHOWS STAIR HANDRAIL MHEIGHT TO BE 36" | | -38". HANDRAIL HEIGHT MAY BE BETWEEN 34" - 38" PER | | FBCR311.7.8. | | 7. PLANS DO NOT SHOW DEMENSIONS FOR STAIRWAY WIDTH. | | STAIRWAY WIDTH SHALL COMPLY WITH FBCR 311.7.1. | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. | | | | R311.7.5.2 TREADS. | | THE MINIMUM TREAD DEPTH SHALL BE 10 INCHES (254 MM). | | THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN | | THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF | | ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD?S | | LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN ANY | | FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE | | THAN 3/8 INCH (9.5 MM). | | | | R311.7.6 LANDINGS FOR STAIRWAYS. | | THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM | | OF EACH STAIRWAY. THE MINIMUM WIDTH PERPENDICULAR TO | | THE DIRECTION OF TRAVEL SHALL BE NO LESS THAN THE WIDTH | | OF THE FLIGHT SERVED. LANDINGS OF SHAPES OTHER THAN | | SQUARE OR RECTANGULAR SHALL BE PERMITTED PROVIDED THE | | DEPTH AT THE WALK LINE AND THE TOTAL AREA IS NOT LESS | | THAN THAT OF A QUARTER CIRCLE WITH A RADIUS EQUAL TO | | THE REQUIRED LANDING WIDTH. WHERE THE STAIRWAY HAS A | | STRAIGHT RUN, THE MINIMUM DEPTH IN THE DIRECTION OF | | TRAVEL SHALL BE NOT LESS THAN 36 INCHES (914 MM). | | | | R311.7.8 HANDRAILS. | | HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF | | EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR | | MORE RISERS. R311.7.8. | | HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED | | PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF | | RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM) | | AND NOT MORE THAN 38 INCHES (965 MM). R311.7.8.1 HEIGHT | | | | R311.7.1 WIDTH. | | STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES (914 MM) IN | | CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL | | HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT. | | HANDRAILS SHALL NOT PROJECT MORE THAN 4.5 INCHES (114 | | MM) ON EITHER SIDE OF THE STAIRWAY AND THE MINIMUM | | CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL | | HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL NOT BE | | LESS THAN 311/2 INCHES (787 MM) WHERE A HANDRAIL IS | | INSTALLED ON ONE SIDE AND 27 INCHES (698 MM) WHERE | | HANDRAILS ARE PROVIDED ON BOTH SIDES. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-04-25 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2018-04-25 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2018-04-25 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-03-12 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-03-12 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-03-12 |
Time |
12:51 |
Sent To |
|
|
Notes |
2018-03-12 15:26:29 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PLAN SHOWS A CARBON MONOXIDE ALARM ON SECOND FLOOR | | IN HALLWAY. IN ADDITION TO THE CO ALARM, A SMOKE ALARM | | IS REQUIRED IN THIS LOCATION. ADDITIONALLY, THE | | DOWNSTAIRS BEDROOM SHOULD HAVE A SMOKE ALARM INSIDE THE | | BEDROOM AS WELL AS A SMOKE/CO ALARM WITHIN 10 FEET OF | | THE BEDROOM, PROVIDE CORRECTION. FBC RE R314.3, R315.1 | | 2. PLAN SHOWS A MAIN DISCONNECT ON THE OUTSIDE OF A | | HOME, FEEDING AN INTERIOR PANEL. THE CONDUCTORS TO | | INTERIOR PANEL SHOULD INCLUDE AN EQUIPMENT GROUNDING | | CONDUCTOR. PROVIDE CORRECTION. NEC 250.122; FBC RE | | E3704.6, 3607.3.1 | | 3. PLAN SHOWS A STANDARD RECESS LIGHT OVER MASTER TUB. | | LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE SUITABLE | | FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC 410.10(D); | | FBC RE E4003.11 | | 4. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | LOADS. SECOND A/C SYSTEM IS NOT INCLUDED. DEMAND | | FACTORS ARE NOT APPLIED PROPERLY. SUB-PANEL LOAD IS | | SHOWN AS 12.0 KW IN MAIN PANEL, BUT AS 4.5 KW IN | | SUB-PANEL. CLARIFY AND/OR CORRECT. SEE FBC RE FOR | | FORMAT. NEC 220; FBC RE E3602.2 | | 5. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH | | CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE | | CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4 | | 6. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | NEC 110.9, 110.10 | | 7. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND | | SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN | | THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE | | INDICATING THE REQUIRED SEPARATE PERMITS AND DATA | | SPECIFICATION SHEET SUBMITTALS FOR ANY OF THESE SYSTEMS | | PRESENT. FBC 105.1, 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2018-05-08 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2018-05-08 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
mgonzale |
Date |
2018-05-08 |
Time |
13:46 |
Sent To |
|
|
Notes |
2018-05-08 13:47:33 | OWNERS HAVE COMPLIED WITH THE UNITY OF TITLE | | APPLICATION. | | | | MANNY GONZALEZ | | SENIOR ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2018-04-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-30 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-30 |
Time |
08:10 |
Sent To |
|
|
Notes |
2018-04-30 08:11:43 | PER ENGINEERING: UNITY OF TITLE REQUIRED | | PLEASE ADVISE ([email protected]) WHEN THIS IS FILED WITH | | THE PALM BEACH COUNTY CLERK'S OFFICE AND ENGINEERING | | REVIEW WILL BE PASSED AT THAT TIME. | | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | /FORMS,-PERMITS-APPLICATIONS | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | MAIN PHONE: (561) 822-1200 | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2018-04-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-10 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
mgonzale |
Date |
2018-04-10 |
Time |
13:43 |
Sent To |
|
|
Notes |
2018-04-10 13:44:30 | PER ENGINEERING: UNITY OF TITLE REQUIRED | | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | /FORMS,-PERMITS-APPLICATIONS | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | MAIN PHONE: (561) 822-1200 | | | 2018-03-02 16:41:06 | EVALUATE FOR UNITY OF TITLE WITH REAR PARCEL, |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2018-05-23 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-05-23 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-05-23 |
Time |
11:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2018-04-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-04-18 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-04-18 |
Time |
15:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2018-03-08 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-03-08 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-03-08 |
Time |
10:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-06-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-06-11 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-05-11 |
Time |
14:53 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-05-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-05-01 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-04-11 |
Time |
12:13 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-04-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-10 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-03-02 |
Time |
10:10 |
Sent To |
|
|
Notes |
2018-04-09 07:35:06 | 4/9 ON SH DESK | | | 2018-03-06 10:10:42 | R08 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
N |
Date |
2018-05-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-05-01 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-05-01 |
Time |
13:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-03-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-29 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-29 |
Time |
14:26 |
Sent To |
|
|
Notes |
2018-03-29 15:32:07 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. THERE IS AN INCREASE OF 58 SQ. FT. UNDER AIR. | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2018-05-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2018-05-29 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2018-05-29 |
Time |
13:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2018-04-19 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-04-19 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-04-19 |
Time |
13:44 |
Sent To |
|
|
Notes |
2018-04-19 13:56:01 | PLAN DENIED | | 1) PROVIDE A/C EQUIPMENT SCHEDULE ON PLAN. | | PER SECTION 107 FBC. 2017. | | 2) PROVIDE DUCT SIZE AND CFM ON | | DUCT IN DRESSING ROOM | | 3) REFER TO SECTION 107.2.1 ALL INFORMATION | | DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE | | PERSON RESPONSIBLE FOR THE DESIGN. | | | | CHRIS MONTELLO | | 561-805-6733 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-04-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2018-04-09 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2018-04-09 |
Time |
08:33 |
Sent To |
|
|
Notes |
2018-04-09 09:16:28 | PLAN DENIED | | 1) PROVIDE EQUIPMENT SCHEDULE ON PLAN. | | PER SECTION 107 FBC. 2017. | | 2) PROVIDE DUCT SIZE AND CFM ON | | DUCT IN DRESSING ROOM | | 3) REFER TO SECTION 107.2.1 ALL INFORMATION | | DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE | | PERSON RESPONSIBLE FOR THE DESIGN. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-06-04 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-06-04 |
Time |
06:58 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-06-04 |
Time |
06:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-04-20 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-04-20 |
Time |
07:10 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-04-20 |
Time |
07:10 |
Sent To |
|
|
Notes |
2018-04-20 07:16:35 | 04/20/2018 2ND PLUMBING REVIEW**DEINED** | | | | 1) LAV SINK ON 1ST FLOOR SHOWING ON SANITARY RISER | | ISOMETRIC SHALL NOT CONNECT INTO THE STACK THAT | | RECEIVESDISCHARGE FROM A TOILET. FBC-R P 3109.2 LAV | | SINK DOES NOT SHOW ON FLOOR PLAN. | | | | 2) 2ND FLOOR GUEST BATHRROM ONLY 1 WET VENTED FIXTURE | | IS PERMITTED BEYOND THE VENT. FBC-R P3108.2.1 | | | | | | TIM HUNT | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | 561-805-6695 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-03-22 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-03-22 |
Time |
17:49 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-03-22 |
Time |
15:00 |
Sent To |
|
|
Notes |
2018-03-22 17:52:17 | 03/22/2018 1ST REVIEW**DENIED** | | | | ON P-3 RISER DIAGRAM, 1 ST FLOOR BATHROOM GROUP CANNOT | | RUN ON THE MAIN TRUNK LINE, SHOW IT AS A BRANCH AND OR | | A AVV, REVENT OR VENT IT OUTSIDE THE UNIT AND DO THE | | SAME FOR THE SECOND FLOOR. FBC R 3104.6 VENT FOR FUTURE | | FIXTURES. | | | | ROMAN TUB REQUIRES A THERMOSTATIC VALVE IN AN | | ACCESSIBLE LOCATION IF SHALL COMPLY WITH ASSE 1017 FBC | | R 2724.1 TEMPERATURE-ACTUATED MIXING VALVES. | | | | PLEASE SHOW WHERE A THERMAL EXPANSION DEVICE IS LOCATED | | FBC R2903.4 THERMAL EXPANSION CONTROL. | | | | THE PLAN SHOWS A POOL AND A SEPARATE BACKFLOW | | PREVENTION DEVICE MAY BE REQUIRED DEPENDING ON FACTORS | | LIKE A POOL FILL AND INSTALLED BY A LICENSED CONTRACTOR | | WITH A SEPARATE APPLICATION AND INSPECTION. FBC R | | 2902.3 BACKFLOW PROTECTION. | | REFER TO THE ITEM BELOW FOR COMPLIANCE | | A. A SITE PLAN DEPICTING THE GENERAL LOCATION OF THE | | PROPOSED BACKFLOW PREVENTION DEVICE. | | B. TWO COPIES OF THE MANUFACTURER?S SPECIFICATIONS FOR | | THE BACKFLOW PREVENTER. THE MAKE, MODEL, AND SIZE OF | | THE DEVICE SHALL BE LISTED IN THE DESCRIPTION OF WORK | | SECTION ON THE PERMIT APPLICATION. | | C. DOCUMENTATION THAT THE PROPOSED DEVICE IS LEAD-FREE. | | D. DOCUMENTATION THAT THE PROPOSED BACKFLOW DEVICE IS | | ON THE APPROVED DEVICE LIST PUBLISHED BY THE UNIVERSITY | | OF SOUTHERN CALIFORNIA (USC). PLEASE CONTACT DEPARTMENT | | OF PUBLIC UTILITY FIELD CUSTOMER SERVICE AT | | 561-822-2240 FOR DOCUMENTED CONFIRMATION THAT THE | | PROPOSED BACKFLOW PREVENTION DEVICE COMPLIES WITH CITY | | REQUIREMENTS. | | E. BACKFLOW PREVENTER REQUIRED PER THE CITY OF WEST | | PALM BEACH ORD #2853-95. A PERMIT REQUIRED BY A | | LICENSED CONTRACTOR AND MUST BE CERTIFIED BY UTILITIES | | PRIOR TO FINAL INSPECTION. PLEASE CONTACT CITY OF WPB | | UTILITIES AT 561-822-2240 FOR FURTHER DIRECTIONS. | | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | REQUIRED FORM A CONTRACTOR TO PERFORM THE RELATED WORK. | | PROVIDE COMPLETE PLANS AND GAS RISER THAT REFLECTS THE | | ENTIRE SCOPE OF GAS WORK TO BE DONE. AT THIS TIME. A | | SEPARATE GAS PERMIT REQUIRED AND A GAS RISER DIAGRAM | | REQUIRED. A NOTE CAN THAT PUT ON PLANS THAT SUBMITTAL | | FOR PRODUCT APPROVAL WILL BE SUBMITTED FOR APPLIANCES | | AND ALL GAS RELATED DOCUMENT. WPB AMENDMENTS TO THE FBC | | SEC. 107.3.5.3 (12) RESIDENTIAL GAS | | REFER TO THE ITEM BELOW FOR COMPLIANCE | | A. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | FBC-2017 FUEL GAS, SECS. 402.4.1, 402.4.2. | | B. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | AMENDMENTS TO FBC SEC. 107.2.1. | | C. TYPE OF GAS, (LP OR NATURAL). | | D. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | THE SYSTEM. REFER TO THE FBC-2017 FBC FUEL GAS RES. | | SEC. G2413. | | E. SUBMIT CALCULATIONS FOR COMBUSTION AIR FOR STOVE PER | | THE FBC-2017 FUEL GAS CODE SEC. 304. | | F. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | AND/OR SYSTEM PER THE FBC-2017 FUEL GAS APPENDIX A ? | | USE OF CAPACITY SECTION A.3.1(4) & INDICATE THE | | DELIVERY PRESSURE (PSI) PER FBC-2017 FUEL GAS SEC. | | 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | G. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND FBC-2017 FUEL GAS SEC. 402.2 | | | | ALL PLUMBING MUST COMPLY WITH FLORIDA BUILDING CODE | | 2017 6TH EDITION. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | [email protected] | | 561-805-6720 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2018-06-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-06-11 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-06-07 |
Time |
16:08 |
Sent To |
|
|
Notes |
2018-06-11 17:12:54 | ROOFING SUBMITTALS TO BE DEFERRED. CT |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2018-05-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-05-01 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-05-01 |
Time |
12:16 |
Sent To |
|
|
Notes |
2018-05-01 13:37:14 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE PRODUCT APPROVALS FOR ROOF SYSTEM COMPONENTS | | OR YOU MAY CHOOSE TO DEFER THESE SUBMITTAL UNTIL A | | LATER DATE. | | 2. DESIGNER TO LIST SUBMITTALS TO BE DEFERRED ON | | CONSTRUCTION DOCUMENTS. | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | SUBMITTALS. | | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | THE DEFERRED SUBMITTALS ON | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2018-03-29 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-29 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-29 |
Time |
14:25 |
Sent To |
|
|
Notes |
2018-03-29 15:33:56 | | | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING PERMIT REQUIRED. | | 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOF SYSTEM | | COMPONENTS. | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-05-23 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-05-23 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-05-23 |
Time |
11:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2018-03-08 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-03-08 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-03-08 |
Time |
10:06 |
Sent To |
|
|
Notes |
|
|