Plan Review Details - Permit 18021080
Plan Review Stops For Permit 18021080
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-03-16 Cont ID  
Sent By jgomez Date 2018-03-16 Time 13:19 Rev Time 0.00
Received By jgomez Date 2018-03-16 Time 11:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2018-08-30 Cont ID  
Sent By jpearson Date 2018-08-30 Time 16:25 Rev Time 0.00
Received By jpearson Date 2018-08-30 Time 16:25 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2018-06-20 Cont ID  
Sent By jpearson Date 2018-06-20 Time 10:41 Rev Time 0.00
Received By jpearson Date 2018-06-20 Time 10:41 Sent To P
Notes
2018-06-20 10:41:00CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. CORRECTED.
 2. CORRECTED.
 3. CORRECTED.
 4. CORRECTED.
 5. CORRECTED.
 6. CORRECTED.
 7. CORRECTED.
 8. CORRECTED.
 9. CORRECTED.
 10. THE RISER DIAGRAM PROVIDED WITH THIS SUBMISSION IS
 VERY DIFFERENT FROM THE LAST SUBMISSION. AS THERE ARE
 OTHER METERS WITH THIS SERVICE, PROVIDE LOAD
 CALCULATION FOR ENTIRE SERVICE IN ADDITION TO THE LOAD
 CALCULATION FOR THE INDIVIDUAL UNIT, INCLUDE EXISTING
 AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS
 ADEQUATE. SHOW WIRE SIZE OF SERVICE ON RISER DIAGRAM TO
 CONFIRM IT IS SIZED TO HANDLE THE ADDITIONAL LOAD. NEC
 215.2, 220, 408.30; FBC RE E3602.3 (EVEN THOUGH
 MULTIPLE METERS ARE PERMITTED FOR 3 UNITS PER THE
 PROPERTY APPRAISERS INFORMATION, ONLY ONE SERVICE IS
 PERMITTED. THIS SERVICE NEEDS TO SIZED TO HANDLE ALL
 LOADS. A SEPARATE SERVICE DROP IS NOT CODE COMPLIANT.
 NEC 230.2 THIS IS THE REASON A RISER DIAGRAM WAS
 REQUESTED AND IS STILL REQUIRED. SHOW RISER DIAGRAM
 WITH DETAILS AS PREVIOUSLY REQUESTED ABOVE.)
 11. CORRECTED.
  
 NEW COMMENTS:
  
 12. RISER DIAGRAM SHOWS A # 8 EQUIPMENT GROUNDING
 CONDUCTOR IN THE CONDUIT FROM THE MAIN DISCONNECT TO
 THE UNIT DISCONNECT. THIS WIRE IS NOT SIZED PROPERLY
 FOR A 125 AMP SERVICE. PROVIDE CORRECTION. NEC 250.122
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-04-23 Cont ID  
Sent By jpearson Date 2018-04-23 Time 17:25 Rev Time 0.00
Received By jpearson Date 2018-04-23 Time 17:25 Sent To P
Notes
2018-04-23 17:25:09CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. LOAD CALCULATION PROVIDED IS INCORRECT. BASED ON THE
 NUMBERS PROVIDED: 10,000 + 16,610 + 6,500 = 33,110 VA,
 DIVIDED BY 240 = 138 AMPS. PROVIDE CORRECTED LOAD
 CALCULATION. NEC 220; FBC RE E3602.3 (LOAD CALCULATION
 NOT CORRECT, SEE NEW COMMENT #9 BELOW. ALSO, MATH IS
 NOT CORRECT.)
 2. IF THE NUMBERS IN COMMENT # 1 RESULT IN SERVICE
 LARGER THAN THE 125 AMP SERVICE SPECIFIED ON PLAN,
 PROVIDE CORRECTION TO SIZE OF SERVICE. NEC 215.2, 220,
 230.42, 408.30 (NOT ADDRESSED AT THIS TIME, AS THE LOAD
 CALCULATION IS NOT CORRECT.)
 3. CORRECTED.
 4. THERE IS A DISCREPANCY ON THE PLAN FOR THE TANKLESS
 WATER HEATER. DETAIL SHOWS THIS IS A 7KW LOAD, WHILE
 THE LOAD CALCULATION SHOWS THIS AS A 30KW LOAD. CLARIFY
 AND/OR CORRECT. FBC 107.2.1 (DISCREPANCY IS STILL
 THERE, ONLY NOW IT SHOWS AS 7 KW ON PRODUCT SPEC AND 11
 KW IN LOAD CALCULATION. PROVIDE CORRECTION.)
 5. CORRECTED.
 6. NOTE # 3 IN ELECTRICAL NOTES STATES THAT RECEPTACLES
 SHALL BE TAMPER RESISTANT PER NEC 406.11. THIS CODE
 SECTION DOES NOT APPLY TO TAMPER RESISTANT RECEPTACLES.
 PROVIDE CORRECTION. NEC 406.12; FBC RE E4002.14 (NOT
 CORRECTED. PROVIDE NOTE THAT ALL RECEPTACLES SHALL BE
 TAMPER RESISTANT PER NEC 406.12 AND FBC RE E4002.14)
 7. CORRECTED.
 8. CORRECTED.
  
 NEW COMMENTS:
  
 9. THE LOAD FOR A DRYER SHALL BE CALCULATED AT 5000
 WATTS OR THE NAMEPLATE RATING, WHICHEVER IS GREATER.
 PROVIDE CORRECTION. NEC 220.54; FBC RE E3602.2
 10. THE RISER DIAGRAM PROVIDED WITH THIS SUBMISSION IS
 VERY DIFFERENT FROM THE LAST SUBMISSION. AS THERE ARE
 OTHER METERS WITH THIS SERVICE, PROVIDE LOAD
 CALCULATION FOR ENTIRE SERVICE IN ADDITION TO THE LOAD
 CALCULATION FOR THE INDIVIDUAL UNIT, INCLUDE EXISTING
 AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS
 ADEQUATE. SHOW WIRE SIZE OF SERVICE ON RISER DIAGRAM TO
 CONFIRM IT IS SIZED TO HANDLE THE ADDITIONAL LOAD. NEC
 215.2, 220, 408.30; FBC RE E3602.3
 11. ONLY THE RECEPTACLE OUTLETS ARE SHOWN AS AFCI
 PROTECTED. PER CODE: "ALL 120-VOLT, SINGLE PHASE, 15
 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS IN
 DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,
 RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR AREAS
 OR ROOMS, SHALL HAVE AFCI PROTECTION." THIS INCLUDES
 LIGHTING AND RECEPTACLE OUTLETS PROVIDE CORRECTION. IF
 DESIRED, A NOTE WILL SUFFICE IN LIEU OF MARKING EACH
 OUTLET WITH AFCI. NEC 210.12; FBC RE E3902.12
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-03-08 Cont ID  
Sent By jpearson Date 2018-03-08 Time 10:12 Rev Time 0.00
Received By jpearson Date 2018-03-08 Time 10:12 Sent To  
Notes
2018-03-08 10:12:29CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. LOAD CALCULATION PROVIDED IS INCORRECT. BASED ON THE
 NUMBERS PROVIDED: 10,000 + 16,610 + 6,500 = 33,110 VA,
 DIVIDED BY 240 = 138 AMPS. PROVIDE CORRECTED LOAD
 CALCULATION. NEC 220; FBC RE E3602.3
 2. IF THE NUMBERS IN COMMENT # 1 RESULT IN SERVICE
 LARGER THAN THE 125 AMP SERVICE SPECIFIED ON PLAN,
 PROVIDE CORRECTION TO SIZE OF SERVICE. NEC 215.2, 220,
 230.42, 408.30
 3. CONDUIT FROM EXTERIOR DISCONNECT TO INTERIOR PANEL
 IS REQUIRED TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR.
 PROVIDE CORRECTION. NEC 250.122
 4. THERE IS A DISCREPANCY ON THE PLAN FOR THE TANKLESS
 WATER HEATER. DETAIL SHOWS THIS IS A 7KW LOAD, WHILE
 THE LOAD CALCULATION SHOWS THIS AS A 30KW LOAD. CLARIFY
 AND/OR CORRECT. FBC 107.2.1
 5. THERE IS A CONFLICT IN THE NOTES. NOTE 4 STATES THAT
 THE WORK SHOULD COMPLY WITH THE 2008 NEC, WHILE OTHER
 AREAS SHOW THE 2011 NEC AS THE PROPER VERSION. REMOVE
 THE CONFLICTING NOTE # 4. FBC 107.2.1
 6. NOTE # 3 IN ELECTRICAL NOTES STATES THAT RECEPTACLES
 SHALL BE TAMPER RESISTANT PER NEC 406.11. THIS CODE
 SECTION DOES NOT APPLY TO TAMPER RESISTANT RECEPTACLES.
 PROVIDE CORRECTION. NEC 406.12; FBC RE E4002.14
 7. NOTE # 2 IN ELECTRICAL NOTES STATES THAT ALL WIRING
 SHALL BE 12 GAUGE WIRE ON 20 AMP CIRCUITS, BUT THE
 SCHEDULE SHOWS 15 AMP CIRCUITS. CLARIFY AND/OR CORRECT.
 FBC 107.2.1
 8. BATH GFCI CIRCUIT IS SHOWN AS A 15 AMP CIRCUIT,
 WHICH IS A CODE VIOLATION. PROVIDE CORRECTION. NEC
 210.11(C)(3) , FBC RE E3703.4
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-03-19 Cont ID  
Sent By fmittner Date 2018-03-19 Time 16:06 Rev Time 0.00
Received By fmittner Date 2018-03-19 Time 16:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2018-09-06 Cont ID  
Sent By jpearson Date 2018-08-31 Time 07:57 Rev Time 0.00
Received By jgomez Date 2018-08-28 Time 16:25 Sent To  
Notes
2018-08-29 12:39:24RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-07-03 Cont ID  
Sent By jgomez Date 2018-06-29 Time 18:13 Rev Time 0.00
Received By jgomez Date 2018-06-14 Time 09:08 Sent To I
Notes
2018-06-18 09:08:49RESUB OF REVISION ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-04-27 Cont ID  
Sent By jgomez Date 2018-04-27 Time 08:43 Rev Time 0.00
Received By jgomez Date 2018-04-20 Time 10:41 Sent To I
Notes
2018-04-23 10:41:41RESUB OF REVISION ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-03-20 Cont ID  
Sent By cpuell Date 2018-03-20 Time 08:56 Rev Time 0.00
Received By cpuell Date 2018-02-26 Time 14:40 Sent To  
Notes
2018-02-27 14:40:28R19

Review Stop P PLUMBING
Rev No 4 Status P Date 2018-09-07 Cont ID  
Sent By jgomez Date 2018-08-31 Time 07:57 Rev Time 0.00
Received By jgomez Date 2018-08-31 Time 18:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2018-07-03 Cont ID  
Sent By jgomez Date 2018-06-29 Time 18:13 Rev Time 0.00
Received By jgomez Date 2018-06-29 Time 17:43 Sent To  
Notes
2018-06-29 17:45:28RESIDENTIAL (R3) REVISION, THIRD PLUMBING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE: PLANS MAY BE SENT TO THE BOARD OF ENGINEERS FOR
 REVIEW BECAUSE OF ENGINEER'S MULTIPLE FAILURE TO
 ADDRESS COMMENTS.
  
 1- REVISE THE DRAIN PIPE SIZE FOR ALL LAVATORIES AND
 KITCHEN SINKS SHOWN IN THE RISER DIAGRAM TO COMPLY WITH
 TABLE P3201.7 FBC-RESIDENTIAL.
  
 RESPONSE: THIRD REJECTION. ENGINEER WILL BE CHARGED 4
 TIMES THE PLAN REVIEW IF COMMENT IS NOT ADDRESSED ON
 NEXT SUBMITTAL. REVISED PLUMBING RISER DIAGRAM 1 STILL
 DOESN'T COMPLY. REVISE AS REQUIRED.
  
  
  
  
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS'
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
  
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY
 REVIEWED DRAWINGS. DON'T STAPLE OLD DRAWINGS TO PLANS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-04-27 Cont ID  
Sent By jgomez Date 2018-04-27 Time 08:22 Rev Time 0.00
Received By jgomez Date 2018-04-27 Time 08:03 Sent To  
Notes
2018-04-27 08:28:41RESIDENTIAL (R3) REVISION, SECOND PLUMBING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- PLUMBING RISER DIAGRAM SUBMITTED SHOWS 2 WET VENTED
 FIXTURES DRAINS DISCHARGING UPSTREAM OF THE DRY VENTED
 FIXTURE DRAIN CONNECTION. REVISE AS REQUIRED.
  
 RESPONSE: SECOND REJECTION. ENGINEER WILL BE CHARGED 4
 TIMES THE PLAN REVIEW IF COMMENT IS NOT ADDRESSED ON
 NEXT SUBMITTAL. REVISED PLUMBING RISER DIAGRAM ONLY
 REVISED BATHROOM #2. BATHROOM #1 STILL DOESN'T COMPLY.
 REVISE AS REQUIRED.
  
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS'
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
  
 SEC. P3108.2.1 FBC-RESIDENTIAL. HORIZONTAL WET VENT.
 THE DRY-VENT CONNECTION FOR A HORIZONTAL WET-VENT
 SYSTEM SHALL BE AN INDIVIDUAL VENT OR A COMMON VENT FOR
 ANY BATHROOM GROUP FIXTURE, EXCEPT AN EMERGENCY FLOOR
 DRAIN. WHERE THE DRY VENT CONNECTS TO A WATER CLOSET
 FIXTURE DRAIN, THE DRAIN SHALL CONNECT HORIZONTALLY TO
 THE HORIZONTAL WET VENT SYSTEM. NOT MORE THAN ONE
 WET-VENTED FIXTURE DRAIN SHALL DISCHARGE UPSTREAM OF
 THE DRY-VENTED FIXTURE DRAIN CONNECTION
  
 2- REVISE THE DRAIN PIPE SIZE FOR ALL LAVATORIES AND
 KITCHEN SINKS SHOWN IN THE RISER DIAGRAM TO COMPLY WITH
 TABLE P3201.7 FBC-RESIDENTIAL.
  
 RESPONSE: SECOND REJECTION. ENGINEER WILL BE CHARGED 4
 TIMES THE PLAN REVIEW IF COMMENT IS NOT ADDRESSED ON
 NEXT SUBMITTAL. REVISED PLUMBING RISER DIAGRAM 1 STILL
 DOESN'T COMPLY. REVISE AS REQUIRED.
  
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS'
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
  
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY
 REVIEWED DRAWINGS. DON'T STAPLE OLD DRAWINGS TO PLANS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-03-16 Cont ID  
Sent By gjohnson Date 2018-03-16 Time 13:19 Rev Time 0.00
Received By jgomez Date 2018-03-16 Time 13:19 Sent To HIST
Notes
2018-03-16 13:36:22RESIDENTIAL (R3) REVISION, PLUMBING REVIEW COMMENTS
 CODE: FBC 5TH EDITION (2014).
  
 1- PLUMBING RISER DIAGRAM SUBMITTED SHOWS 2 WET VENTED
 FIXTURES DRAINS DISCHARGING UPSTREAM OF THE DRY VENTED
 FIXTURE DRAIN CONNECTION. REVISE AS REQUIRED.
  
 SEC. P3108.2.1 FBC-RESIDENTIAL. HORIZONTAL WET VENT.
 THE DRY-VENT CONNECTION FOR A HORIZONTAL WET-VENT
 SYSTEM SHALL BE AN INDIVIDUAL VENT OR A COMMON VENT FOR
 ANY BATHROOM GROUP FIXTURE, EXCEPT AN EMERGENCY FLOOR
 DRAIN. WHERE THE DRY VENT CONNECTS TO A WATER CLOSET
 FIXTURE DRAIN, THE DRAIN SHALL CONNECT HORIZONTALLY TO
 THE HORIZONTAL WET VENT SYSTEM. NOT MORE THAN ONE
 WET-VENTED FIXTURE DRAIN SHALL DISCHARGE UPSTREAM OF
 THE DRY-VENTED FIXTURE DRAIN CONNECTION
  
 2- REVISE THE DRAIN PIPE SIZE FOR ALL LAVATORIES AND
 KITCHEN SINKS SHOWN IN THE RISER DIAGRAM TO COMPLY WITH
 TABLE P3201.7 FBC-RESIDENTIAL.
  
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY
 REVIEWED DRAWINGS. DON'T STAPLE OLD DRAWINGS TO PLANS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  