Plan Review Details - Permit 18021080
Plan Review Stops For Permit 18021080 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-03-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-03-16 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-03-16 |
Time |
11:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2018-08-30 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-08-30 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-08-30 |
Time |
16:25 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2018-06-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-06-20 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-06-20 |
Time |
10:41 |
Sent To |
P |
|
Notes |
2018-06-20 10:41:00 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. CORRECTED. | | 2. CORRECTED. | | 3. CORRECTED. | | 4. CORRECTED. | | 5. CORRECTED. | | 6. CORRECTED. | | 7. CORRECTED. | | 8. CORRECTED. | | 9. CORRECTED. | | 10. THE RISER DIAGRAM PROVIDED WITH THIS SUBMISSION IS | | VERY DIFFERENT FROM THE LAST SUBMISSION. AS THERE ARE | | OTHER METERS WITH THIS SERVICE, PROVIDE LOAD | | CALCULATION FOR ENTIRE SERVICE IN ADDITION TO THE LOAD | | CALCULATION FOR THE INDIVIDUAL UNIT, INCLUDE EXISTING | | AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS | | ADEQUATE. SHOW WIRE SIZE OF SERVICE ON RISER DIAGRAM TO | | CONFIRM IT IS SIZED TO HANDLE THE ADDITIONAL LOAD. NEC | | 215.2, 220, 408.30; FBC RE E3602.3 (EVEN THOUGH | | MULTIPLE METERS ARE PERMITTED FOR 3 UNITS PER THE | | PROPERTY APPRAISERS INFORMATION, ONLY ONE SERVICE IS | | PERMITTED. THIS SERVICE NEEDS TO SIZED TO HANDLE ALL | | LOADS. A SEPARATE SERVICE DROP IS NOT CODE COMPLIANT. | | NEC 230.2 THIS IS THE REASON A RISER DIAGRAM WAS | | REQUESTED AND IS STILL REQUIRED. SHOW RISER DIAGRAM | | WITH DETAILS AS PREVIOUSLY REQUESTED ABOVE.) | | 11. CORRECTED. | | | | NEW COMMENTS: | | | | 12. RISER DIAGRAM SHOWS A # 8 EQUIPMENT GROUNDING | | CONDUCTOR IN THE CONDUIT FROM THE MAIN DISCONNECT TO | | THE UNIT DISCONNECT. THIS WIRE IS NOT SIZED PROPERLY | | FOR A 125 AMP SERVICE. PROVIDE CORRECTION. NEC 250.122 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-04-23 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-04-23 |
Time |
17:25 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-04-23 |
Time |
17:25 |
Sent To |
P |
|
Notes |
2018-04-23 17:25:09 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. LOAD CALCULATION PROVIDED IS INCORRECT. BASED ON THE | | NUMBERS PROVIDED: 10,000 + 16,610 + 6,500 = 33,110 VA, | | DIVIDED BY 240 = 138 AMPS. PROVIDE CORRECTED LOAD | | CALCULATION. NEC 220; FBC RE E3602.3 (LOAD CALCULATION | | NOT CORRECT, SEE NEW COMMENT #9 BELOW. ALSO, MATH IS | | NOT CORRECT.) | | 2. IF THE NUMBERS IN COMMENT # 1 RESULT IN SERVICE | | LARGER THAN THE 125 AMP SERVICE SPECIFIED ON PLAN, | | PROVIDE CORRECTION TO SIZE OF SERVICE. NEC 215.2, 220, | | 230.42, 408.30 (NOT ADDRESSED AT THIS TIME, AS THE LOAD | | CALCULATION IS NOT CORRECT.) | | 3. CORRECTED. | | 4. THERE IS A DISCREPANCY ON THE PLAN FOR THE TANKLESS | | WATER HEATER. DETAIL SHOWS THIS IS A 7KW LOAD, WHILE | | THE LOAD CALCULATION SHOWS THIS AS A 30KW LOAD. CLARIFY | | AND/OR CORRECT. FBC 107.2.1 (DISCREPANCY IS STILL | | THERE, ONLY NOW IT SHOWS AS 7 KW ON PRODUCT SPEC AND 11 | | KW IN LOAD CALCULATION. PROVIDE CORRECTION.) | | 5. CORRECTED. | | 6. NOTE # 3 IN ELECTRICAL NOTES STATES THAT RECEPTACLES | | SHALL BE TAMPER RESISTANT PER NEC 406.11. THIS CODE | | SECTION DOES NOT APPLY TO TAMPER RESISTANT RECEPTACLES. | | PROVIDE CORRECTION. NEC 406.12; FBC RE E4002.14 (NOT | | CORRECTED. PROVIDE NOTE THAT ALL RECEPTACLES SHALL BE | | TAMPER RESISTANT PER NEC 406.12 AND FBC RE E4002.14) | | 7. CORRECTED. | | 8. CORRECTED. | | | | NEW COMMENTS: | | | | 9. THE LOAD FOR A DRYER SHALL BE CALCULATED AT 5000 | | WATTS OR THE NAMEPLATE RATING, WHICHEVER IS GREATER. | | PROVIDE CORRECTION. NEC 220.54; FBC RE E3602.2 | | 10. THE RISER DIAGRAM PROVIDED WITH THIS SUBMISSION IS | | VERY DIFFERENT FROM THE LAST SUBMISSION. AS THERE ARE | | OTHER METERS WITH THIS SERVICE, PROVIDE LOAD | | CALCULATION FOR ENTIRE SERVICE IN ADDITION TO THE LOAD | | CALCULATION FOR THE INDIVIDUAL UNIT, INCLUDE EXISTING | | AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS | | ADEQUATE. SHOW WIRE SIZE OF SERVICE ON RISER DIAGRAM TO | | CONFIRM IT IS SIZED TO HANDLE THE ADDITIONAL LOAD. NEC | | 215.2, 220, 408.30; FBC RE E3602.3 | | 11. ONLY THE RECEPTACLE OUTLETS ARE SHOWN AS AFCI | | PROTECTED. PER CODE: "ALL 120-VOLT, SINGLE PHASE, 15 | | AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS IN | | DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, | | RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR AREAS | | OR ROOMS, SHALL HAVE AFCI PROTECTION." THIS INCLUDES | | LIGHTING AND RECEPTACLE OUTLETS PROVIDE CORRECTION. IF | | DESIRED, A NOTE WILL SUFFICE IN LIEU OF MARKING EACH | | OUTLET WITH AFCI. NEC 210.12; FBC RE E3902.12 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-03-08 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-03-08 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-03-08 |
Time |
10:12 |
Sent To |
|
|
Notes |
2018-03-08 10:12:29 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. LOAD CALCULATION PROVIDED IS INCORRECT. BASED ON THE | | NUMBERS PROVIDED: 10,000 + 16,610 + 6,500 = 33,110 VA, | | DIVIDED BY 240 = 138 AMPS. PROVIDE CORRECTED LOAD | | CALCULATION. NEC 220; FBC RE E3602.3 | | 2. IF THE NUMBERS IN COMMENT # 1 RESULT IN SERVICE | | LARGER THAN THE 125 AMP SERVICE SPECIFIED ON PLAN, | | PROVIDE CORRECTION TO SIZE OF SERVICE. NEC 215.2, 220, | | 230.42, 408.30 | | 3. CONDUIT FROM EXTERIOR DISCONNECT TO INTERIOR PANEL | | IS REQUIRED TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR. | | PROVIDE CORRECTION. NEC 250.122 | | 4. THERE IS A DISCREPANCY ON THE PLAN FOR THE TANKLESS | | WATER HEATER. DETAIL SHOWS THIS IS A 7KW LOAD, WHILE | | THE LOAD CALCULATION SHOWS THIS AS A 30KW LOAD. CLARIFY | | AND/OR CORRECT. FBC 107.2.1 | | 5. THERE IS A CONFLICT IN THE NOTES. NOTE 4 STATES THAT | | THE WORK SHOULD COMPLY WITH THE 2008 NEC, WHILE OTHER | | AREAS SHOW THE 2011 NEC AS THE PROPER VERSION. REMOVE | | THE CONFLICTING NOTE # 4. FBC 107.2.1 | | 6. NOTE # 3 IN ELECTRICAL NOTES STATES THAT RECEPTACLES | | SHALL BE TAMPER RESISTANT PER NEC 406.11. THIS CODE | | SECTION DOES NOT APPLY TO TAMPER RESISTANT RECEPTACLES. | | PROVIDE CORRECTION. NEC 406.12; FBC RE E4002.14 | | 7. NOTE # 2 IN ELECTRICAL NOTES STATES THAT ALL WIRING | | SHALL BE 12 GAUGE WIRE ON 20 AMP CIRCUITS, BUT THE | | SCHEDULE SHOWS 15 AMP CIRCUITS. CLARIFY AND/OR CORRECT. | | FBC 107.2.1 | | 8. BATH GFCI CIRCUIT IS SHOWN AS A 15 AMP CIRCUIT, | | WHICH IS A CODE VIOLATION. PROVIDE CORRECTION. NEC | | 210.11(C)(3) , FBC RE E3703.4 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2018-03-19 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-03-19 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-03-19 |
Time |
16:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-09-06 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-08-31 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-08-28 |
Time |
16:25 |
Sent To |
|
|
Notes |
2018-08-29 12:39:24 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-07-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-06-29 |
Time |
18:13 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-06-14 |
Time |
09:08 |
Sent To |
I |
|
Notes |
2018-06-18 09:08:49 | RESUB OF REVISION ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-04-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-04-27 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-04-20 |
Time |
10:41 |
Sent To |
I |
|
Notes |
2018-04-23 10:41:41 | RESUB OF REVISION ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-03-20 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2018-03-20 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-02-26 |
Time |
14:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2018-09-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-08-31 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-08-31 |
Time |
18:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2018-07-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-06-29 |
Time |
18:13 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-06-29 |
Time |
17:43 |
Sent To |
|
|
Notes |
2018-06-29 17:45:28 | RESIDENTIAL (R3) REVISION, THIRD PLUMBING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | NOTE: PLANS MAY BE SENT TO THE BOARD OF ENGINEERS FOR | | REVIEW BECAUSE OF ENGINEER'S MULTIPLE FAILURE TO | | ADDRESS COMMENTS. | | | | 1- REVISE THE DRAIN PIPE SIZE FOR ALL LAVATORIES AND | | KITCHEN SINKS SHOWN IN THE RISER DIAGRAM TO COMPLY WITH | | TABLE P3201.7 FBC-RESIDENTIAL. | | | | RESPONSE: THIRD REJECTION. ENGINEER WILL BE CHARGED 4 | | TIMES THE PLAN REVIEW IF COMMENT IS NOT ADDRESSED ON | | NEXT SUBMITTAL. REVISED PLUMBING RISER DIAGRAM 1 STILL | | DOESN'T COMPLY. REVISE AS REQUIRED. | | | | | | | | | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS' | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DON'T STAPLE OLD DRAWINGS TO PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-04-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-04-27 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-04-27 |
Time |
08:03 |
Sent To |
|
|
Notes |
2018-04-27 08:28:41 | RESIDENTIAL (R3) REVISION, SECOND PLUMBING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- PLUMBING RISER DIAGRAM SUBMITTED SHOWS 2 WET VENTED | | FIXTURES DRAINS DISCHARGING UPSTREAM OF THE DRY VENTED | | FIXTURE DRAIN CONNECTION. REVISE AS REQUIRED. | | | | RESPONSE: SECOND REJECTION. ENGINEER WILL BE CHARGED 4 | | TIMES THE PLAN REVIEW IF COMMENT IS NOT ADDRESSED ON | | NEXT SUBMITTAL. REVISED PLUMBING RISER DIAGRAM ONLY | | REVISED BATHROOM #2. BATHROOM #1 STILL DOESN'T COMPLY. | | REVISE AS REQUIRED. | | | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS' | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | SEC. P3108.2.1 FBC-RESIDENTIAL. HORIZONTAL WET VENT. | | THE DRY-VENT CONNECTION FOR A HORIZONTAL WET-VENT | | SYSTEM SHALL BE AN INDIVIDUAL VENT OR A COMMON VENT FOR | | ANY BATHROOM GROUP FIXTURE, EXCEPT AN EMERGENCY FLOOR | | DRAIN. WHERE THE DRY VENT CONNECTS TO A WATER CLOSET | | FIXTURE DRAIN, THE DRAIN SHALL CONNECT HORIZONTALLY TO | | THE HORIZONTAL WET VENT SYSTEM. NOT MORE THAN ONE | | WET-VENTED FIXTURE DRAIN SHALL DISCHARGE UPSTREAM OF | | THE DRY-VENTED FIXTURE DRAIN CONNECTION | | | | 2- REVISE THE DRAIN PIPE SIZE FOR ALL LAVATORIES AND | | KITCHEN SINKS SHOWN IN THE RISER DIAGRAM TO COMPLY WITH | | TABLE P3201.7 FBC-RESIDENTIAL. | | | | RESPONSE: SECOND REJECTION. ENGINEER WILL BE CHARGED 4 | | TIMES THE PLAN REVIEW IF COMMENT IS NOT ADDRESSED ON | | NEXT SUBMITTAL. REVISED PLUMBING RISER DIAGRAM 1 STILL | | DOESN'T COMPLY. REVISE AS REQUIRED. | | | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS' | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DON'T STAPLE OLD DRAWINGS TO PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-03-16 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-03-16 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-03-16 |
Time |
13:19 |
Sent To |
HIST |
|
Notes |
2018-03-16 13:36:22 | RESIDENTIAL (R3) REVISION, PLUMBING REVIEW COMMENTS | | CODE: FBC 5TH EDITION (2014). | | | | 1- PLUMBING RISER DIAGRAM SUBMITTED SHOWS 2 WET VENTED | | FIXTURES DRAINS DISCHARGING UPSTREAM OF THE DRY VENTED | | FIXTURE DRAIN CONNECTION. REVISE AS REQUIRED. | | | | SEC. P3108.2.1 FBC-RESIDENTIAL. HORIZONTAL WET VENT. | | THE DRY-VENT CONNECTION FOR A HORIZONTAL WET-VENT | | SYSTEM SHALL BE AN INDIVIDUAL VENT OR A COMMON VENT FOR | | ANY BATHROOM GROUP FIXTURE, EXCEPT AN EMERGENCY FLOOR | | DRAIN. WHERE THE DRY VENT CONNECTS TO A WATER CLOSET | | FIXTURE DRAIN, THE DRAIN SHALL CONNECT HORIZONTALLY TO | | THE HORIZONTAL WET VENT SYSTEM. NOT MORE THAN ONE | | WET-VENTED FIXTURE DRAIN SHALL DISCHARGE UPSTREAM OF | | THE DRY-VENTED FIXTURE DRAIN CONNECTION | | | | 2- REVISE THE DRAIN PIPE SIZE FOR ALL LAVATORIES AND | | KITCHEN SINKS SHOWN IN THE RISER DIAGRAM TO COMPLY WITH | | TABLE P3201.7 FBC-RESIDENTIAL. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DON'T STAPLE OLD DRAWINGS TO PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
|