Plan Review Details - Permit 18020842
Plan Review Stops For Permit 18020842
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-03-21 Cont ID  
Sent By rmcdouga Date 2018-03-21 Time 19:10 Rev Time 0.00
Received By rmcdouga Date 2018-03-21 Time 18:28 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-02-23 Cont ID  
Sent By rmcdouga Date 2018-02-23 Time 08:49 Rev Time 0.00
Received By rmcdouga Date 2018-02-23 Time 08:49 Sent To  
Notes
2018-02-23 11:07:35PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THIS STRUCTURE IS LOCATED IN EXPOSURE CATEGORY B
 WITH A VULT WIND SPEED OF 170 MPH. THE ROOFING SYSTEM
 THAT WAS INDICATED DOES NOT MEET THE REQUIRED DESIGN
 PRESSURES FOR THE PERIMETER AND CORNER ROOF AREAS. THE
 TPO SYSTEM SPECIFIED ON PAGES 7 AND 8 OF NOA NO.
 14-0326.08 HAS A MAXIMUM DESIGN PRESSURE OF -45 PSF AND
 CAN NOT BE INCREASED BY ENHANCED FASTENING PER
 LIMITATION NUMBER 9 ON PAGE 22.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-03-21 Cont ID  
Sent By rmcdouga Date 2018-03-21 Time 19:10 Rev Time 0.00
Received By rmcdouga Date 2018-03-20 Time 11:34 Sent To  
Notes
2018-03-21 11:34:38RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-02-23 Cont ID  
Sent By rmcdouga Date 2018-02-23 Time 11:21 Rev Time 0.00
Received By rmcdouga Date 2018-02-20 Time 11:23 Sent To  
Notes
2018-02-21 11:23:34SHILL