Plan Review Details - Permit 18020733
Plan Review Stops For Permit 18020733
Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2018-03-02 Cont ID  
Sent By squinone Date 2018-03-02 Time   Rev Time 0.00
Received By squinone Date 2018-03-02 Time   Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-06-07 Cont ID  
Sent By thunt Date 2018-06-07 Time 15:23 Rev Time 0.00
Received By thunt Date 2018-06-06 Time 11:48 Sent To I
Notes
2018-06-07 11:48:57RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-03-02 Cont ID  
Sent By cpuell Date 2018-03-02 Time 16:56 Rev Time 0.00
Received By cpuell Date 2018-02-16 Time 13:09 Sent To  
Notes
2018-02-20 13:09:53PLUMB <5K

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-06-07 Cont ID  
Sent By thunt Date 2018-06-07 Time 15:23 Rev Time 0.00
Received By thunt Date 2018-06-07 Time 15:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-02-20 Cont ID  
Sent By thunt Date 2018-02-20 Time 15:34 Rev Time 0.00
Received By thunt Date 2018-02-20 Time 15:34 Sent To ENG
Notes
2018-02-20 15:41:4202/20/2018 PLUBING 1ST REVIEW**DENIED**
  
 1) VALUE OF JOB SEEMS LOW. 109.3 BUILDING PERMIT
 VALUATIONS. IF, IN THE OPINION OF THE BUILDING
 OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW
 DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED
 CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE
 APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL
 BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE
 LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION
 COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.),
 AS PUBLISHED BY INTERNATIONAL CODE CONGRESS.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  
 2) PROVIDE A SANITARY RISER DRAWING OF ALL FIXTURES AND
 DFU'S THAT WILL BE DISCHARGING INTO THIS INTERCEPTOR.
 FBC 107.3.5 PLUMBING #4
  
 3) SHOW CALCULATIONS OF ALL DRAINAGE UNDER FULL DEMAND.
 HOW DID YOU DETERMINED THE SIZE OF THE INTERCEPTOR. FBC
 P 1003.3.6
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  