2018-02-28 14:10:07 | BUILDING PLAN REVIEW |
| 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER, PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. PLAN DRAWING KS2072 IS BASED ON THE 2014 FBC 5TH ED. |
| 2. CURRENT GOVERNING CODE IS THE 2017 FBC 6TH ED. |
| 3. PROVIDE PLAN BASED ON CURRENT CODE. |
| 4. ENGINEER'S SIGNATURE AND SEAL IS PHOTOCOPIED. |
| 5. RESIDENTIAL POOL BARRIER'S SHALL COMPLY WITH THE |
| 2017 FBC 6TH ED. RESIDENTIAL CHPT. 45. GATE AND LATCH |
| SHALL COMPLY WITH SECTION 4501.17.1.8. |
| |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE 2017 |
| FLORIDA BUILDING CODE, 6TH EDITION. |
| |
| PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND |
| SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, |
| DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE |
| 61G15-23.001. |
| |
| R4501.17.1.8 |
| ACCESS GATES, WHEN PROVIDED, SHALL BE SELF-CLOSING AND |
| SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS |
| R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED |
| WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON THE POOL |
| SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED |
| NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE |
| GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON |
| EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE |
| REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY |
| OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE |
| ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM |
| THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING |
| GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457 |
| MM) OF THE RELEASE MECHANISM. |
| |
| |
| |
| |