Plan Review Details - Permit 18020441
Plan Review Stops For Permit 18020441
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-04-05 Cont ID  
Sent By cthroop Date 2018-04-05 Time 16:53 Rev Time 0.00
Received By cthroop Date 2018-04-05 Time 16:49 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-04-02 Cont ID  
Sent By scaldero Date 2018-04-02 Time 11:22 Rev Time 0.00
Received By cthroop Date 2018-04-02 Time 14:06 Sent To  
Notes
2018-04-02 14:51:45 
 BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. APPLICANT FAILED TO PULL AND MARK OLD PLANS VOID.
 2. ZONING AND FIRE STAMPED OLD PLAN SET.
 3. ROUTING SUBMITTAL BACK TO ZONING (JR). ZONING TO
 ROUTE TO FIRE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-02-27 Cont ID  
Sent By cthroop Date 2018-02-27 Time 10:55 Rev Time 0.00
Received By cthroop Date 2018-02-27 Time 10:55 Sent To FIRE
Notes
2018-02-27 11:16:05BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DESIGN WIND LOADS BASED ON ASCE 7-10 ARE VALID, BUT
 PLANS ARE BASED ON THE 2014 FBC. THE CURRENT GOVERNING
 CODE IS THE 2017 FBC 6TH ED. PLEASE CORRECT CODE
 REFERENCE ON PLANS.
 2. ENGINEER OF RECORD TO SIGN AND SEAL ALL PLAN AGES.
 3. PROVIDE FLAME SPREAD REPORT FOR AWNING FABRIC PER
 ASTM E-84 OR NFPA 701.
 4. PROVIDE SITE PLAN. SHOW LOCATION OF ALL WORK.
 5. PROVIDE DETAIL OF EXISTING OR PROPOSED FOUNDATION.
  
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE 2017
 FLORIDA BUILDING CODE, 6TH EDITION.
  
 PURSUANT TO FBC 107.1, AND FS 481.229 (1) I, AS THIS
 DESIGN EXCEEDS $25,000.00 IN VALUE, THE DESIGN MUST BE
 PREPARED BY A LICENSED PROFESSIONAL PURSUANT TO FS 481.
 SEE BELOW:
  
 PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE,
 DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE
 61G15-23.001.
  
 FBC 603.1 FLAME SPREAD ? ASTM E-84-09
  
 FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING
 OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA
 AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION
 PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL
 FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING
 DIMENSIONS; AND ALL EXTERIOR ELEVATIONS:
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
  
  
  
  
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-03-30 Cont ID  
Sent By scaldero Date 2018-03-27 Time 11:06 Rev Time 0.00
Received By scaldero Date 2018-03-26 Time 11:13 Sent To B
Notes
2018-03-27 10:56:36PERMIT # 18020441
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 APPROVED PROVISO COMMENTS:
  
 1) APPROVED PER CONVERSATION WITH THE CONTRACTOR THAT
 THIS PROJECT IS IN COMPLIANCE WITH NFPA 13, CHAPTER 8.
 8.15.7 * EXTERIOR PROJECTIONS.
 8.15.7.1
 UNLESS THE REQUIREMENTS OF 8.15.7.2, 8.15.7.3, OR
 8.15.7.4 ARE MET, SPRINKLERS SHALL BE INSTALLED UNDER
 EXTERIOR PROJECTIONS EXCEEDING 4 FT (1.2 M) IN WIDTH.
  
 8.15.7.2 *
 SPRINKLERS SHALL BE PERMITTED TO BE OMITTED WHERE THE
 EXTERIOR PROJECTIONS ARE CONSTRUCTED WITH MATERIALS
 THAT ARE NONCOMBUSTIBLE, LIMITED-COMBUSTIBLE, OR FIRE
 RETARDANT?TREATED WOOD AS DEFINED IN NFPA 703.
  
 8.15.7.3
 SPRINKLERS SHALL BE PERMITTED TO BE OMITTED FROM BELOW
 THE EXTERIOR PROJECTIONS OF COMBUSTIBLE CONSTRUCTION,
 PROVIDED THE EXPOSED FINISH MATERIAL ON THE EXTERIOR
 PROJECTIONS ARE NONCOMBUSTIBLE, LIMITED-COMBUSTIBLE, OR
 FIRE RETARDANT?TREATED WOOD AS DEFINED IN NFPA 703, AND
 THE EXTERIOR PROJECTIONS CONTAIN ONLY SPRINKLERED
 CONCEALED SPACES OR ANY OF THE FOLLOWING UNSPRINKLERED
 COMBUSTIBLE CONCEALED SPACES:
 (1) COMBUSTIBLE CONCEALED SPACES FILLED ENTIRELY WITH
 NONCOMBUSTIBLE INSULATION
 (2) LIGHT OR ORDINARY HAZARD OCCUPANCIES WHERE
 NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE CEILINGS ARE
 DIRECTLY ATTACHED TO THE BOTTOM OF SOLID WOOD JOISTS SO
 AS TO CREATE ENCLOSED JOIST SPACES 160 FT3 (4.5 M3) OR
 LESS IN VOLUME, INCLUDING SPACE BELOW INSULATION THAT
 IS LAID DIRECTLY ON TOP OR WITHIN THE CEILING JOISTS IN
 AN OTHERWISE SPRINKLERED ATTIC [SEE 11.2.3.1.4(4)(D)]
 (3) CONCEALED SPACES OVER ISOLATED SMALL EXTERIOR
 PROJECTIONS NOT EXCEEDING 55 FT2 (5.1 M2) IN AREA
  
 8.15.7.4
 SPRINKLERS SHALL BE PERMITTED TO BE OMITTED FROM
 EXTERIOR EXIT CORRIDORS WHEN THE EXTERIOR WALLS OF THE
 CORRIDOR ARE AT LEAST 50 PERCENT OPEN AND WHEN THE
 CORRIDOR IS ENTIRELY OF NONCOMBUSTIBLE CONSTRUCTION.
  
 8.15.7.5 *
 SPRINKLERS SHALL BE INSTALLED UNDER EXTERIOR
 PROJECTIONS GREATER THAN 2 FT (0.6 M) WIDE OVER AREAS
 WHERE COMBUSTIBLES ARE STORED.
  
 2) COMPLIANCE WITH THE ABOVE CODE WILL BE VERIFIED IN
 THE FIELD AT TIME OF FINAL INSPECTION.
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2018-03-01 Cont ID  
Sent By scaldero Date 2018-03-01 Time 12:47 Rev Time 0.00
Received By scaldero Date 2018-03-01 Time 12:43 Sent To I
Notes
2018-03-01 12:47:48PERMIT # 18020441
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 FAILED COMMENTS:
  
 1) A PROPER SITE PLAN IS REQUIRED. PLEASE INDICATE IF
 THIS AWNINGS ARE ATTACHED OR DETACHED FROM THE
 STRUCTURE. ALSO, PLEASE INDICATE IF THE STRUCTURE IS
 PROTECTED THROUGHOUT BY A FIRE SPRINKLER SYSTEM.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-04-02 Cont ID  
Sent By cthroop Date 2018-04-02 Time 14:47 Rev Time 0.00
Received By cthroop Date 2018-03-13 Time 15:23 Sent To Z
Notes
2018-04-02 14:48:11ZONING AND FIRE TO STAMP NEW PLANS. CT
2018-03-14 15:23:13ROUTED TO FIRE INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-03-01 Cont ID  
Sent By cpuell Date 2018-03-01 Time 13:58 Rev Time 0.00
Received By cpuell Date 2018-02-09 Time 09:12 Sent To  
Notes
2018-02-13 09:12:43ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2018-04-05 Cont ID  
Sent By jroach Date 2018-04-05 Time 09:26 Rev Time 0.00
Received By jroach Date 2018-04-05 Time 09:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-02-22 Cont ID  
Sent By JR Date 2018-02-22 Time 09:51 Rev Time 0.00
Received By jroach Date 2018-02-16 Time 10:59 Sent To B
Notes
***NONE***