Plan Review Stops For Permit 18020402 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-05 |
Time |
17:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-05 |
Time |
17:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-05-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-22 |
Time |
18:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-22 |
Time |
18:15 |
Sent To |
|
|
Notes |
2018-05-22 18:17:17 | ****PROVISOS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | PRODUCT APPROVALS REVIEWED BY DESIGNER OF RECORD ARE TO | | BE SUBMITTED TO THE BUILDING DIVISION, REVIEWED, AND | | ISSUED PRIOR TO INSTALLATION. | | | | PRECAST PLANK JOIST SYSTEMS ENGINEERING ARE TO BE | | REVIEWED BY STRUCTURAL ENGINEER OF RECORD ARE TO BE | | SUBMITTED TO THE BUILDING DIVISION, REVIEWED, AND | | ISSUED PRIOR TO INSTALLATION. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-04-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-04-09 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-04-09 |
Time |
09:39 |
Sent To |
|
|
Notes |
2018-04-09 09:44:36 | NEW CAR WAS STRUCTURE, SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017). | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR | | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME | | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | ISSUANCE. | | | | | | ORIGINAL COMMENT: | | 1) THE COVERSHEET OF THE ARCHITECTURAL PLANS IS DATED | | 12/18/2017 IN THE ARCHITECTURAL SHEETS THERE IS NO | | REFERENCE TO WHAT PLANS THEY WERE DEVELOPED. IN THE | | STRUCTURAL SHEETS, SHEET S13.0.1 UNDER THE HEADING | | STRUCTURAL SPECIFICATIONS / MISCELLANEOUS NOTE # 4 | | INDICATES THE APPLICABLE BUILDING CODE: 5TH EDITION | | (2014) FLORIDA BUILDING CODE. | | THE 6TH EDITION (2017) FLORIDA WAS ADOPTED STATEWIDE ON | | DEC. 31/ 2017. PLEASE UPDATE THE PLANS TO THE | | APPLICABLE CODE. | | | | RESPONSE: | | STRUCTURAL SHEET S13.01 WAS NOT UPDATED. STILL | | REFERENCING THE OLD CODE. REVISE AS REQUIRED TO AVOID | | CONFLICTS WITH THE THE REVISED ARCHITECTURAL COVER | | SHEET. NOTE: ARCHITECTURAL COVER SHEET 13.CVR WAS | | UPDATED WITH THE CURRENT CODE IN EFFECT BUT THE | | BUILDING HEIGHT AND AREA INFORMATION IS INCORRECT. THE | | ACTUAL BUILDING AREA IS 2,123.5 S.F. NOT 2,000 S.F. | | AND, THE ALLOWABLE BUILDING AREA FOR TYPE II | | CONSTRUCTION IS 23,000 S.F. NOT 23.00 S.F. PROVIDE | | CORRECT INFORMATION TO AVOID CONFLICTS/DELAYS. | | | | ORIGINAL COMMENT: | | 2A- THE ARCHITECTURAL PLAN A13.4.0 INDICATES THE FINISH | | ROOFING SYSTEM IS TO BE TPO ROOFING SYSTEM. PLEASE | | PROVIDE THE PRODUCT APPROVAL REPORT FOR THIS PRODUCT. / | | 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31) (D) ROOFING PRODUCTS AND ASSEMBLIES, | | | | RESPONSE: | | NO SUBMITTAL AT THIS TIME. THIS MAY BE SUBMITTED LATER | | BUT BEFORE INSPECTIONS TO AVOID CONFLICTS/DELAYS. | | | | ORIGINAL COMMENT: | | 2B) FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL | | ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR | | ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, | | IF ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | PREPARED, SIGNED AND | | SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR | | REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS & | | CLADDING. | | | | RESPONSE: | | NO SUBMITTAL AT THIS TIME. THIS MAY BE SUBMITTED LATER | | BUT BEFORE INSPECTIONS TO AVOID CONFLICTS/DELAYS. | | | | ORIGINAL COMMENT: | | 2C) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | RESPONSE: | | NO SUBMITTAL AT THIS TIME. THIS MAY BE SUBMITTED LATER | | BUT BEFORE INSPECTIONS TO AVOID CONFLICTS/DELAYS. | | | | | | ORIGINAL COMMENT: | | 3- SHEET S13.0.2. SHOWS A MONO-SLOPED ROOF WITH NO | | PARAPETS. PRESSURES ARE THE SAME FOR ZONE 2 AND 3 | | PLEASE PROVIDE WHY THE NEGATIVE ROOF PRESSURES HAVE NOT | | BEEN INCREASED. THE MONO- SLOPED ROOF DETAIL EVEN SHOWS | | (4) ROOF ZONE 3?S. ASCE 7-10 FIGURE 30.4-5A. PLEASE | | UPDATE PLANS. | | | | RESPONSE: | | NEGATIVE PRESSURES WERE REVISED, BUT CLARIFY WHY ALL | | THE POSITIVE PRESSURES WERE REDUCED? | | | | | | ORIGINAL COMMENT: | | 6) BUILDING PROVISO: PRECAST PLANK JOIST SYSTEMS ARE TO | | BE A DEFERRED SUBMITTAL AND TO BE REVIEWED BY THE | | DESIGNER OF RECORD, WHEN APPROVED THE ARCHITECTS SHOP | | DRAWING STAMP OF APPROVAL APPLIED AND FORWARDED TO THE | | BUILDING DEPARTMENT. | | | | ACKNOWLEDGED BY ARCHITECT. PROVIDE INFORMATION ON A | | TIMELY FASHION PRIOR TO INSPECTIONS TO AVOID | | CONFLICTS/DELAYS. | | | | | | NOTE: | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-03-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2018-03-05 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2018-03-05 |
Time |
14:49 |
Sent To |
|
|
Notes |
2018-03-05 16:37:36 | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 18020402 | | ADD: 2901 OKEECHOBEE BLVD. | | CONT: HEDRICK BROTHERS | | TEL: 561-360-3817 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 1ST REVIEW | | DATE: MON. MARCH 05/ 2018 | | ACTION: DENIED | | | | 1) THE COVERSHEET OF THE ARCHITECTURAL PLANS IS DATED | | 12/18/2017 IN THE ARCHITECTURAL SHEETS THERE IS NO | | REFERENCE TO WHAT PLANS THEY WERE DEVELOPED. IN THE | | STRUCTURAL SHEETS, SHEET S13.0.1 UNDER THE HEADING | | STRUCTURAL SPECIFICATIONS / MISCELLANEOUS NOTE # 4 | | INDICATES THE APPLICABLE BUILDING CODE: 5TH EDITION | | (2014) FLORIDA BUILDING CODE. | | THE 6TH EDITION (2017) FLORIDA WAS ADOPTED STATEWIDE ON | | DEC. 31/ 2017. PLEASE UPDATE THE PLANS TO THE | | APPLICABLE CODE. | | | | 2) 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | BUILDINGS: | | 107.3.5.1 COMMERCIAL BUILDINGS: | | 107.3.5.1.1 BUILDING | | 2.1. OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS | | SHALL BE DETERMINED. | | 2.2. MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED | | (SEE TABLE 506.2). | | | | 3) MISSING THE SOILS REPORT. THE STRUCTURAL SHEET | | S13.0.1. UNDER THE HEADING SITE WORK NOTE # 1 INDICATES | | A SUBSURFACE INVESTIGATION HAS BEEN COMPLETED BY | | ARDAMAN & ASSOCIATES REPORT DATED MAY 07/ 2015, WHICH | | IS AN INTEGRAL PART OF THESE CONTRACT DOCUMENTS. 2017 | | FBC-B SECTION 1803.5.2 QUESTIONABLE SOIL. | | | | 4A) THE ARCHITECTURAL PLAN A13.4.0 INDICATES THE FINISH | | ROOFING SYSTEM IS TO BE TPO ROOFING SYSTEM. PLEASE | | PROVIDE THE PRODUCT APPROVAL REPORT FOR THIS PRODUCT. / | | 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31) (D) ROOFING PRODUCTS AND ASSEMBLIES, | | | | 4B) FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL | | ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR | | ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, | | IF ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | PREPARED, SIGNED AND | | SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR | | REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS & | | CLADDING. | | | | 4C) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 5) SHEET S13.0.2. SHOWS A MONO-SLOPED ROOF WITH NO | | PARAPETS. PRESSURES ARE THE SAME FOR ZONE 2 AND 3 | | PLEASE PROVIDE WHY THE NEGATIVE ROOF PRESSURES HAVE NOT | | BEEN INCREASED. THE MONO- SLOPED ROOF DETAIL EVEN SHOWS | | (4) ROOF ZONE 3?S. ASCE 7-10 FIGURE 30.4-5A. PLEASE | | UPDATE PLANS. | | | | 6) BUILDING PROVISO: PRECAST PLANK JOIST SYSTEMS ARE TO | | BE A DEFERRED SUBMITTAL AND TO BE REVIEWED BY THE | | DESIGNER OF RECORD, WHEN APPROVED THE ARCHITECTS SHOP | | DRAWING STAMP OF APPROVAL APPLIED AND FORWARDED TO THE | | BUILDING DEPARTMENT. | | | | 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-04-08 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-04-08 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-04-08 |
Time |
10:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-03-07 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-03-07 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-03-07 |
Time |
14:25 |
Sent To |
|
|
Notes |
2018-03-07 14:26:31 | E-13.1 SHOWS WRONG BUILDING CODE EDITION. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-05 |
Time |
18:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-05 |
Time |
18:16 |
Sent To |
|
|
Notes |
2018-06-05 18:16:15 | OK PER MG | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
F |
Date |
2018-05-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-22 |
Time |
18:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-22 |
Time |
18:21 |
Sent To |
|
|
Notes |
2018-05-22 18:21:44 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | APPLICATION IF REQUIRED | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | /FORMS,-PERMITS-APPLICATIONS | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | MAIN PHONE: (561) 822-1200 | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2018-04-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-12 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-12 |
Time |
12:23 |
Sent To |
|
|
Notes |
2018-04-12 12:24:35 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | APPLICATION IF REQUIRED | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | /FORMS,-PERMITS-APPLICATIONS | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | MAIN PHONE: (561) 822-1200 | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2018-03-23 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-03-23 |
Time |
15:25 |
Sent To |
|
|
Notes |
2018-03-23 15:25:28 | NO REVIEW PERFORMED, WILL BE DONE DURING 2ND CYCLE. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2018-02-26 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-02-26 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-02-26 |
Time |
10:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-05 |
Time |
18:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-30 |
Time |
11:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-05-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-22 |
Time |
18:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-04 |
Time |
08:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-04-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-12 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-03-29 |
Time |
10:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2018-03-23 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-02-23 |
Time |
12:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-04-09 |
Time |
17:09 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-04-09 |
Time |
17:09 |
Sent To |
|
|
Notes |
2018-04-09 17:10:20 | NO FEES DUE. MU-2018-009761. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-03-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2018-03-05 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2018-03-05 |
Time |
14:52 |
Sent To |
|
|
Notes |
2018-03-05 16:38:08 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. ONE SET OF | | PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR | | REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE | | OFFICE LOCATED AT 2300 N. JOG RD. ROOMS 2W01-2W14 WEST | | PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE | | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | (561)233-5025 FOR MORE INFORMATION. | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2018-04-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-04-09 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-04-09 |
Time |
14:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-03-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-03-09 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-03-09 |
Time |
16:12 |
Sent To |
|
|
Notes |
2018-03-09 16:21:01 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18020402 | | 3/9/18 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET SP-4: PROVIDE VEHICULAR DAMAPE PROTECTION FOR | | THE RELOCATED GENERATOR- SECTION 303.4. | | | | 2) NO MECHANICAL PLANS WERE UPLOADED FOR REVIEW. PLEASE | | CLARIFY IF ANY VENTILATION FANS, WATER HEATERS, BOILERS | | OR OTHER MECHANICAL EQUIPMENT WILL BE INSTALLED. | | PROVIDE DRAWINGS, DETAILS, AND SPECIFICATIONS IF | | APPLICABLE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2018-03-19 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-03-19 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-03-17 |
Time |
12:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
Rev No |
1 |
Status |
P |
Date |
2018-03-19 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-03-19 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-03-19 |
Time |
09:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2018-05-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-22 |
Time |
18:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-22 |
Time |
18:19 |
Sent To |
|
|
Notes |
2018-05-22 18:20:17 | SEPARATE ROOF PERMIT REQUIRED | | PRODUCT APPROVALS REVIEWED BY DESIGNER OF RECORD TO BE | | SUBMITTED WITH ROOF PERMIT APPLICATION | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2018-06-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-06-05 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-05 |
Time |
17:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2018-05-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-22 |
Time |
18:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-22 |
Time |
18:21 |
Sent To |
|
|
Notes |
2018-05-22 18:21:17 | CIVIL SHEETS ARE NOT DIGITALLY SIGNED AND SEALED. SEE | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED DATED | | ORGINALS. PAPER ORIGINAL SIGNED AND SEALED DOCUMENTS | | MAY BE SUBMITTED TO SATISFY THIS REQUIREMENT. | | | | ALL OTHER PAGES ARE DIGITALLY SIGNED AND SEALED IN | | ACCORDANCE WITH FS471, FS481. NEW SHEETS SUBMITTED FOR | | 3RD CYCLE NEED REVIEW. | | | | [email protected] | | 561-805-6724 | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2018-04-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-12 |
Time |
12:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-12 |
Time |
12:25 |
Sent To |
|
|
Notes |
2018-04-12 12:31:05 | CIVIL SHEETS ARE NOT DIGITALLY SIGNED AND SEALED. SEE | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED DATED | | ORGINALS. PAPER ORIGINAL SIGNED AND SEALED DOCUMENTS | | MAY BE SUBMITTED TO SATISFY THIS REQUIREMENT. | | | | ALL OTHER PAGES ARE DIGITALLY SIGNED AND SEALED IN | | ACCORDANCE WITH FS471, FS481. NEW SHEETS SUBMITTED FOR | | 3RD CYCLE NEED REVIEW. | | | | [email protected] | | 561-805-6724 | | | | | | | | | 2018-03-19 09:53:31 | 3/19/18 DIG SIG ON PLUMB PG OK/GPJ |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2018-05-31 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2018-05-31 |
Time |
16:34 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2018-05-31 |
Time |
15:52 |
Sent To |
|
|
Notes |
2018-05-31 16:35:36 | PASSED | | | | 1) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING: | | | | A. PARKING LOT STRIPING | | B. NEW/RELOCATED SITE LIGHTING | | | | 2) PLEASE CONTACT THE ENGINEERING SERVICES DIVISION FOR | | ANY PERMITTING REQUIREMENTS. | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2018-05-16 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2018-05-16 |
Time |
15:42 |
Rev Time |
0.75 |
Received By |
eschneid |
Date |
2018-05-16 |
Time |
14:20 |
Sent To |
|
|
Notes |
2018-05-16 15:42:41 | FAILED | | | | PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | 1) REPEAT COMMENT: THE SITE PLAN PROVIDED WITH THE | | PERMIT IS NOT THE SAME SITE PLAN APPROVED AS PART OF | | THE MINOR SITE PLAN AMENDMENT. THE APPROVED PLANS SHALL | | BE PROVIDED WITH THE PERMIT. THE APPROVED SITE PLAN | | SHEETS SP-1, SP-2 AND SP-3 HAVE A LAST REVISION DATED | | OF FEBRUARY 26, 2018. THE PLANS INCLUDED WITH THE | | PERMIT ARE DATED FEBRUARY 22, 2018, WHICH PREDATES THE | | APPROVED PLANS. | | | | 2) THE SUBMITTAL OF A LANDSCAPE PERMIT IS REQUIRED | | PRIOR TO ZONING APPROVAL OF THIS PERMIT. THE LANDSCAPE | | PLANS SUBMITTED WITH THIS PERMIT ARE NOT THE FINAL | | APPROVED LANDSCAPE PLANS. THE LANDSCAPE PERMIT MUST | | INCLUDE THE APPROVED PLANS. PLEASE CONTACT THE DIGITAL | | INTAKE CLERK, LAURA MARCHANT, TO COORDINATE THE REMOVAL | | OF THE INCORRECT LANDSCAPE PLANS INCLUDED WITH THIS | | PERMIT. | | | | SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING: | | | | A. PARKING LOT STRIPING | | B. NEW/RELOCATED SITE LIGHTING | | C. SITE ENGINEERING | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2018-04-11 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2018-04-11 |
Time |
11:03 |
Rev Time |
2.00 |
Received By |
eschneid |
Date |
2018-04-11 |
Time |
08:57 |
Sent To |
|
|
Notes |
2018-04-11 10:56:35 | FAILED | | | | PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | 1) THE SITE PLAN PROVIDED WITH THE PERMIT IS NOT THE | | SAME SITE PLAN APPROVED AS PART OF THE MINOR SITE PLAN | | AMENDMENT. THE APPROVED PLANS SHALL BE PROVIDED WITH | | THE PERMIT. | | | | 2) SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWING: | | | | A. PARKING LOT STRIPING | | B. LANDSCAPE - THE LANDSCAPE PLANS INCLUDED WITH THIS | | PERMIT SUBMITTAL MUST BE REMOVED FROM THIS PERMIT. | | C. NEW/RELOCATED SITE LIGHTING | | D. SITE ENGINEERING | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-02-26 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2018-02-26 |
Time |
08:32 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2018-02-26 |
Time |
08:32 |
Sent To |
|
|
Notes |
2018-02-26 08:33:30 | FAILED | | | | THE SITE PLAN HAS NOT YET BEEN APPROVED BY THE PPRC. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] |
|
|