Plan Review Details - Permit 18020364
Plan Review Stops For Permit 18020364
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-05-30 Cont ID  
Sent By cthroop Date 2018-05-30 Time 08:17 Rev Time 0.00
Received By cthroop Date 2018-05-30 Time 08:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-05-25 Cont ID  
Sent By cthroop Date 2018-05-25 Time 10:00 Rev Time 0.00
Received By cthroop Date 2018-05-24 Time 16:16 Sent To  
Notes
2018-05-25 10:23:43BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. RE-LOCATING THE EXISTING FRENCH DOORS OPENS UP THE
 BUILDING ENVELOPE AND INCREASES CONDITIONED SPACE.
 1A. PROVIDE ENERGY SUBMITTAL.
  
 2. RE-LOCATE AND INSTALL EXISTING SHUTTERS AT NEW DOOR
 LOCATION.
 STORM SHUTTERS
 PROVIDE STORM PANEL INFORMATION WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND
 MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC
 1609.1.2.
  
 3. NEW HABITABLE SPACE REQUIRES MOISTURE BARRIER UNDER
 CONCRETE SLAB. VERIFY EXISTING 6 MIL. PLASTIC OR
 INSTALL 6 MIL PLASTIC UNDER PROPOSED CONCRETE OVERPOUR.
 R506.2.3 VAPOR RETARDER.
 A 6-MIL (0.006 INCH; 152 ?M) POLYETHYLENE OR APPROVED
 VAPOR RETARDER WITH JOINTS LAPPED NOT LESS THAN 6
 INCHES (152 MM) SHALL BE PLACED BETWEEN THE CONCRETE
 FLOOR SLAB AND THE BASE COURSE OR THE PREPARED SUBGRADE
 WHERE NO BASE COURSE EXISTS.
  
 4. VERIFY OR INSTALL ADEQUATE FOOTING UNDER NEW CMU
 WALL.
 R401.2 REQUIREMENTS.
 FOUNDATIONS SHALL BE CAPABLE OF RESISTING ALL LOADS
 FROM ROOF UPLIFT AND BUILDING OVERTURN. FOUNDATION
 UPLIFT FOR LIGHT-FRAME WOOD OR STEEL BUILDINGS SHALL BE
 CALCULATED OR DETERMINED FROM TABLE R401.1. MASONRY
 BUILDINGS WITHIN THE DIMENSIONAL SCOPE OF TABLE R401.1
 SHALL BE ASSUMED TO BE OF ADEQUATE WEIGHT SO AS NOT TO
 REQUIRE UPLIFT RESISTANCE GREATER THAN THAT PROVIDED BY
 THE STRUCTURE AND ANY NORMAL FOUNDATION. FOUNDATION
 CONSTRUCTION SHALL ALSO BE CAPABLE OF ACCOMMODATING ALL
 GRAVITY LOADS IN ACCORDANCE WITH SECTION R301 AND OF
 TRANSMITTING THE RESULTING LOADS TO THE SUPPORTING
 SOIL. FILL SOILS THAT SUPPORT FOOTINGS AND FOUNDATIONS
 SHALL BE DESIGNED, INSTALLED AND TESTED IN ACCORDANCE
 WITH ACCEPTED ENGINEERING PRACTICE. GRAVEL FILL USED AS
 FOOTINGS FOR WOOD AND PRECAST CONCRETE FOUNDATIONS
 SHALL COMPLY WITH SECTION R403.
  
 5. PROVIDE LANDING AT EXTERIOR DOOR.
 R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS.
 THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH
 EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE
 LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A
 MINIMUM DIMENSION OF 36 INCHES (914 MM) MEASURED IN THE
 DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE
 PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4 UNIT
 VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-03-06 Cont ID  
Sent By skennedy Date 2018-03-06 Time 09:41 Rev Time 0.00
Received By skennedy Date 2018-03-06 Time 09:41 Sent To  
Notes
2018-03-07 13:45:261ST REVIEW: FBC 2017 6TH ED. RESIDENTIAL
 1ST REVIEW FBC 2017 EXISTING BUILDING
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES.
 FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.
  
 PROVIDE THE FOLLOWING MINIMUM INFORMATION:
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3.
 SPECIFICALLY, PROVIDE A DOOR SUBMITTAL.
 FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
 FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
 FBC 107.3.5.3 ? INDICATE THE MEANS OF TERMITE
 PROTECTION PROPOSED PURSUANT TO FBC-R318.
 FBC 107 - PROVIDE DETAILS FOR THE CONSTRICTION OF
 EXTERIOR WALLS:EG SHOW IF BLOCK AND SHOW STEEL
 RE-INFORCING SIZE AND SPACING AND METHOD OF CONNECTION
 TO EXISTING STRUCTURE. SHOW EXISTING OR PROPOSED
 ADDITIONAL FOOTINGS FOR EXTERIOR WALL AREA. SHOW THE
 FINISH OF INTERIOR AND EXTERIOR WALLS. SHOW ANY
 PROPOSED ADDITION AND MEANS OF RAISING THE EXISTING
 FLOOR AREA. WILL CONCRETE BE ADDED. WILL THE FLOOR BE
 LEVELED? SHOW ANY PROPOSED LANDING FOR THE EXTERIOR OF
 PROPOSED NEW DOOR. NOTE A MINIMUM 3 FEET LONG LANDING
 IS REQUIRED ALONG THE WIDTH OF THE OPENING.
 FBC - R301.2.1.2 PROTECTION OF OPENINGS. SHOW METHOD OF
 IMPACT PROTECTION FOR GLAZING IF NOT IMPACT RESISTANT.
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-05-24 Cont ID  
Sent By jleahy Date 2018-05-24 Time 09:02 Rev Time 0.00
Received By jleahy Date 2018-05-24 Time 09:02 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-03-06 Cont ID  
Sent By skennedy Date 2018-03-06 Time 09:42 Rev Time 0.00
Received By skennedy Date 2018-03-06 Time 09:42 Sent To  
Notes
2018-03-07 14:01:461ST REVIEW: FBC 2017 6TH ED. RESIDENTIAL
 1ST REVIEW FBC 2017 EXISTING BUILDING
  
  
 PROVIDE ELECTRICAL AS FOLLOWS:
 E3901.2.1 SPACING. RECEPTACLES SHALL BE INSTALLED SO
 THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR
 LINE OF ANY WALL SPACE IS MORE THAN 6 FEET (1829 MM),
 FROM A RECEPTACLE OUTLET.
 FBCRE3902.12 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION.
 FBCRE3903.3 ADDITIONAL LOCATIONS. AT LEAST ONE
 WALL-SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE
 INSTALLED TO PROVIDE ILLUMINATION ON THE EXTERIOR SIDE
 OF EACH OUTDOOR EGRESS DOOR HAVING GRADE LEVEL ACCESS
 FBCRE4002.14 TAMPER-RESISTANT RECEPTACLES IN AREAS
 SPECIFIED IN SECTION E3901.1, 125-VOLT, 15- AND
 20-AMPERE RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT
 RECEPTACLES.
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-06-07 Cont ID  
Sent By cthroop Date 2018-06-07 Time 17:10 Rev Time 0.00
Received By cthroop Date 2018-06-06 Time 10:23 Sent To I
Notes
2018-06-07 10:23:17IMPACT ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-05-25 Cont ID  
Sent By cthroop Date 2018-05-25 Time 11:27 Rev Time 0.00
Received By cthroop Date 2018-05-02 Time 10:33 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-03-15 Cont ID  
Sent By ajones Date 2018-03-15 Time 11:43 Rev Time 0.00
Received By ajones Date 2018-02-08 Time 10:03 Sent To  
Notes
2018-02-12 10:03:26R25

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2018-06-07 Cont ID  
Sent By cthroop Date 2018-06-07 Time 17:10 Rev Time 0.00
Received By cthroop Date 2018-06-07 Time 17:09 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2018-05-25 Cont ID  
Sent By cthroop Date 2018-05-25 Time 09:59 Rev Time 0.00
Received By cthroop Date 2018-05-24 Time 16:17 Sent To  
Notes
2018-05-25 10:00:42BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. CONDITIONED SPACE HAS BEEN INCREASED. IMPACT FEES
 MAY APPLY.
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-03-06 Cont ID  
Sent By skennedy Date 2018-03-06 Time 09:42 Rev Time 0.00
Received By skennedy Date 2018-03-06 Time 09:42 Sent To  
Notes
2018-03-06 09:51:521ST REVIEW FBC 2017 EXISTING BUILDING
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND
 TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED
 WITH A COPY OF RECEIPT AS APPLICABLE.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2018-03-06 Cont ID  
Sent By skennedy Date 2018-03-06 Time 09:41 Rev Time 0.00
Received By skennedy Date 2018-03-06 Time 09:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2018-03-06 Cont ID  
Sent By skennedy Date 2018-03-06 Time 09:42 Rev Time 0.00
Received By skennedy Date 2018-03-06 Time 09:42 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-03-15 Cont ID  
Sent By AV Date 2018-03-15 Time 11:42 Rev Time 0.00
Received By ajones Date 2018-03-14 Time 10:31 Sent To  
Notes
***NONE***