Plan Review Details - Permit 18020355
Plan Review Stops For Permit 18020355 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-02-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-26 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-26 |
Time |
09:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-02-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-22 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-22 |
Time |
11:03 |
Sent To |
|
|
Notes |
2018-02-22 11:03:46 | RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017). | | | | 1- THE DESIGN PRESSURES OF GARAGE DOOR NOA 17-0920.03 | | SUBMITTED DON'T MEET THE NEGATIVE AND POSITIVE DESIGN | | PRESSURES REQUIRED FOR A BUILDING LOCATED IN EXPOSURE | | "D". PROVIDE ANOTHER PRODUCT APPROVAL THAT MEETS THE | | DESIGN PRESSURES FOR EXPOSURE "D". | | NOTE: CALCULATIONS SUBMITTED ARE NOT THE RIGHT | | CALCULATIONS TO BE USED FOR GARAGE DOORS. NEED TO USE | | TABLE R301.2(4) FBC-RESIDENTIAL, 6TH EDITION (2017) FOR | | GARAGE DOORS. AND ADJUST THE CALCULATIONS TO THE | | BUILDING EXPOSURE "D" AND CORRESPONDING MEAN ROOF | | HEIGHT. OTHERWISE, PROVIDE COMPLETE SIGNED AND SEALED | | SITE SPECIFIC CALCULATIONS | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-02-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-15 |
Time |
18:47 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-15 |
Time |
18:29 |
Sent To |
|
|
Notes |
2018-02-15 18:51:06 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | CODE: FBC 6TH EDITION (2017). | | | | 1- ACCORDING TO SEC. R301.2.1.4 FBC-RESIDENTIAL, 6TH | | EDITION (2017) THIS HOUSE IS LOCATED IN EXPOSURE "D". | | THE DESIGN PRESSURES OF GARAGE DOOR NOA 17-0920.03 | | SUBMITTED DON'T MEET THE DESIGN PRESSURES REQUIRED FOR | | A BUILDING LOCATED IN EXPOSURE "D". PROVIDE ANOTHER | | PRODUCT APPROVAL THAT MEETS THE DESIGN PRESSURES FOR | | EXPOSURE "D". | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-02-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-26 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-26 |
Time |
09:16 |
Sent To |
|
|
Notes |
2018-02-26 09:17:29 | CONTRACTOR E-MAILED NEW NOA. | | | | GOOD MORNING, | | | | | | | | ATTACHED IS THE NOA (#- 17-1016.17) FOR PERMIT-18020355 | | LOCATED AT 3530 EMBASSY DR. PLEASE LET ME KNOW IF YOU | | HAVE ANY QUESTIONS. | | | | | | | | THANK YOU, | | | | PEYTON | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-02-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-22 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-20 |
Time |
10:00 |
Sent To |
I |
|
Notes |
2018-02-21 10:00:32 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-02-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-15 |
Time |
18:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-08 |
Time |
13:49 |
Sent To |
I |
|
Notes |
2018-02-09 13:50:05 | BLDG <5K |
|
|
|
Account Summary | Usage Policy | Privacy Policy