Plan Review Details - Permit 18020327
Plan Review Stops For Permit 18020327
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-05-19 Cont ID  
Sent By cthroop Date 2018-05-19 Time 09:10 Rev Time 0.00
Received By cthroop Date 2018-05-19 Time 09:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-04-21 Cont ID  
Sent By cthroop Date 2018-04-21 Time 11:03 Rev Time 0.00
Received By cthroop Date 2018-04-21 Time 10:59 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-02-10 Cont ID  
Sent By cthroop Date 2018-02-10 Time 10:59 Rev Time 0.00
Received By cthroop Date 2018-02-10 Time 10:58 Sent To  
Notes
2018-02-10 11:00:47BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PROVIDE THE FOLLOWING INFORMATION FOR FLOORING:
  
 1. FLOOR PLAN WITH DIMENSIONS AND LOCATION OF WORK.
 *DESIGNER TO PRINT NAME AND SIGN PLAN PER FBC 107 *
 2. TOTAL SQUARE FOOTAGE OF NEW FLOORING.
 3. TYPE OF PROPOSED FLOORING
 (TILE/MARBLE/LAMINATE/WOOD/OTHER).
 4. STATED VALUE OF WORK.
 5. EXISTING SITE CONDITIONS:
 A) THICKNESS OF SLAB. B) CEILING ASSEMBLY (OPEN
 CONCRETE/SUSPENDED GYPSUM/ACOUSTICAL)
 6. PROPOSED UNDERLAYMENT.
 7. TEST REPORTS FOR PROPOSED UNDERLAYMENT BASED ON
 EXISTING SITE CONDITIONS.
 8. TEST REPORTS MAY BE BASED ON THE FOLLOWING ASTM?S,
 E-84, E-90 & E-492.
 9. ALL DOCUMENTS SHALL BE SUBMITTED IN DUPLICATE.
  
 FBC 603.1 FLAME SPREAD ? ASTM E-84-09
  
 FBC 1207.2 AIR-BORNE SOUND. ASTM E - 90-04
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E - 492-09
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC SPACE OR SERVICE
 AREA WITHIN THE STRUCTURE SHALL HAVE AN IMPACT
 INSULATION CLASS (IIC) RATING OF NOT LESS THAN 50 (45
 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E
 492.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-05-11 Cont ID  
Sent By cthroop Date 2018-05-19 Time 09:11 Rev Time 0.00
Received By jleahy Date 2018-05-11 Time 14:15 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-05-19 Cont ID  
Sent By cthroop Date 2018-05-19 Time 09:11 Rev Time 0.00
Received By cthroop Date 2018-05-10 Time 13:39 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-04-24 Cont ID  
Sent By thunt Date 2018-04-24 Time 18:09 Rev Time 0.00
Received By thunt Date 2018-04-12 Time 10:04 Sent To  
Notes
2018-04-13 10:04:34RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-02-10 Cont ID  
Sent By cthroop Date 2018-02-10 Time 11:00 Rev Time 0.00
Received By cthroop Date 2018-02-07 Time 10:05 Sent To I
Notes
2018-02-08 10:05:29PLUMB <5K

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-05-18 Cont ID  
Sent By tklarge Date 2018-05-18 Time 07:16 Rev Time 0.00
Received By tklarge Date 2018-05-18 Time 05:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-04-24 Cont ID  
Sent By thunt Date 2018-04-24 Time 17:39 Rev Time 0.00
Received By thunt Date 2018-04-24 Time 17:39 Sent To  
Notes
2018-04-24 17:54:2504/24/2018 2ND PLUMBING REVIEW**DENIED**
  
 PLEASE BE ADVISED THE NEW SET OF PLANS ARE SHOWING THIS
 AS THE ONLY BATHROOM AND THE 1ST SET OF PLANS SUBMITTED
 DO NOT HAVE THE CORRECT ADDRESS ON THEM. THIS BUILDING
 BUILT IN 2005 UNDER PERMIT # 03020961 WAS BUILT
 COMPLING WITH THE FAIR HOUSING DESIGN MANUAL WITH SPEC
 A BATHROOM WHICH MUST FULLY REMAIN.
  
  
 1) A SHOWER INSTALLED ADJACENT TO A TOILET IS NOT
 ACCEPTABLE UNDER THE GUIDELINES ( FAIR HOUSING MANUAL
 7.44)
  
 2) SHOWER VALVE IS NOT IN A ACCESSIBLE LOCATION TO BE
 ACCESSED FROM THE CLEAR FLOOR SPACE AREA.
  
 3) WHERE A SHOWER IS THE ONLY BATHING FIXTURE IN A
 DWELLING IT MUST COMPLY WITH ( FAIR HOUSING MANUAL 7.58
  
 4) SHOW CABINET DETAIL. MAX COUNTER TOP TO SINK IS 34".
 ( FAIR HOUSING MANUAL 7.52
  
 5) SHOW ALL REQUIRED CLEAR FLOOR SPACES. ( FAIR HOUSING
 MANUAL 7.43)
  
 6) TOILETS ARE REQUIRED TO BE 18" MIN ON GRAB BAR SIDE
 AND 15" ON NONE GRAB BAR SIDE TOTAL MIN 33". ( FAIR
 HOUSING MANUAL 7.43)
  
 7) EXISTING DRAIN OFFSET TO BE 30" MAX FROM CENTERLINE
 OF TRAP. FBC-P 1002.1
  
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-02-09 Cont ID  
Sent By thunt Date 2018-02-09 Time 04:56 Rev Time 0.00
Received By thunt Date 2018-02-09 Time 04:56 Sent To B
Notes
***NONE***