Plan Review Stops For Permit 18020062 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-30 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-29 |
Time |
16:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-03-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-06 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-02 |
Time |
16:03 |
Sent To |
|
|
Notes |
2018-03-06 08:45:02 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PLAN IS BASED ON THE 2014 FBC. PROVIDE PLAN BASED ON | | THE 2017 FBC 6TH ED. | | 2. PALM BEACH COUNTY IMPACT FEES REQUIRED. | | 3. PLAN PAGE A-A SHOWS DETAIL 1, A-3. THERE IS NO | | DETAIL 1 ON PLAN PAGE A-3. PLEASE CLARIFY. | | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE 2017 | | FLORIDA BUILDING CODE, 6TH EDITION. | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-03-28 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2018-03-28 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2018-03-28 |
Time |
10:10 |
Sent To |
|
|
Notes |
2018-03-28 10:14:37 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. CORRECTED | | 2. CORRECTED | | 3. CORRECTED | | | | END OF COMMENT | | | | SINCERELY, | | | | PHIL PETTY | | CHIEF ELECTRICAL INSPECTOR | | 561-805-6742 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-02-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-02-22 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-02-22 |
Time |
08:21 |
Sent To |
|
|
Notes |
2018-02-22 09:56:44 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. THE NEC AND FBC SPECIFIED FOR DESIGN IS NOT THE | | CURRENT CODE. PROVIDE CORRECTION. FBC PREFACE (ALSO SEE | | CURRENT CODES ABOVE) | | 2. CIRCUIT FOR BATHROOM GFCI RECEPTACLES IS SHOWN AS 15 | | AMP. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH | | CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE | | CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4 | | 3. LIGHTING IN CLOSET IS SHOWN AS A RECESS LIGHT. PER | | CODE: "LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS | | AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE | | PERMITTED IN CLOTHES CLOSETS". PROVIDE CORRECTION. NEC | | 410.16; FBC RE E4003.12 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2018-03-16 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-03-16 |
Time |
06:45 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-03-16 |
Time |
06:45 |
Sent To |
|
|
Notes |
2018-03-16 06:46:51 | A SPERATE GAS REVIEW HAS BEEN DONE UNDER PERMIT | | 18020386 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-30 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-14 |
Time |
13:52 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-03-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-06 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-02-02 |
Time |
13:22 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2018-03-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-30 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-30 |
Time |
14:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-03-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-03-06 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-03-02 |
Time |
16:03 |
Sent To |
|
|
Notes |
2018-03-06 08:39:06 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2018-03-01 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-03-01 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-03-01 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-03-16 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-03-16 |
Time |
07:01 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-03-16 |
Time |
07:01 |
Sent To |
|
|
Notes |
2018-03-16 07:03:02 | 03/16/18 APPROVED BY PLUMBING AND PUT BACK IN R06, LAC |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-02-28 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-02-28 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-02-28 |
Time |
14:28 |
Sent To |
|
|
Notes |
2018-02-28 14:34:07 | DENIED | | | | 1. THIS REVIEW IS BASED ON THE 2017 FLORIDA BUILDING | | CODE 6TH EDITION. PLEASE REMOVE ALL REFERENCES TO THE | | 2014 FBC 5TH EDITION. WPB AMENDMENTS TO THE FBC 107.2.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 2. CONNECTION UNDER SLAB SHALL BE MADE WITH APPROVED | | FITTING, IF JOINING CAST IRON WITH PVC IT SHALL COMPLY | | WITH SECTIONS P3003.4.1 THROUGH P3003.4.3. | | | | 3. THE PLAN SHOWS A BACKFLOW PREVENTION DEVICE AT WATER | | SERVICE BUT NOT REQUIRED. IF ONE WAS TO BE INSTALLED A | | SEPARATE PERMIT APPLICATION, INSPECTION AND | | CERTIFICATION WILL BE REQUIRED AND THE LOCATION SHALL | | BE WITHIN 5' FROM THE CITY METER. IT SHALL BE CERTIFIED | | BY UTILITIES AT OWNERS EXPENSE. WPB AMENDMENTS TO THE | | FBC 105.1. | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | [email protected] | | 561-805-6720 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
AW |
Date |
2018-03-23 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2018-03-23 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
AW |
Date |
2018-02-13 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2018-02-13 |
Time |
|
Sent To |
|
|
Notes |
|
|