2018-02-13 16:41:08 | RESIDENTIAL (R3) RE-ROOF, THIRD BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017). | | | | 1- TU PUS FLORIDA PRODUCT APPROVAL FL5259-R27 AND FRSA | | REVISED TABLE 1A SUBMITTED: THE BASIC WIND SPEED FOR | | THE CITY OF WEST PALM BEACH IS 170MPH NOT 140 MPH. | | REVISE AS REQUIRED. NEED TO REVISE THE UNDERLAYMENT | | SYSTEM TO BE INSTALLED TO MEET THE REVISED DESIGN | | PRESSURES. SEC. R301.2.1 FBC-RESIDENTIAL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-02-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-07 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-06 |
Time |
17:55 |
Sent To |
|
|
Notes |
2018-02-06 17:56:16 | RESIDENTIAL (R3) RE-ROOF, SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017). | | | | 1- TU PUS FLORIDA PRODUCT APPROVAL FL5259-R27: | | A) FRSA TABLE 1A SUBMITTED IS NOT CURRENT. THE CURRENT | | 5TH EDITION OF THE FRSA MANUAL WAS REVISED. NEED TO USE | | TABLE 1A OF THE REVISED FRSA MANUAL 5TH EDITION. | | PROVIDE NEW TABLE AND REVISE UNDERLAYMENT SYSTEM TO BE | | INSTALLED AS REQUIRED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.2.1 FBC-RESIDENTIAL. | | | | B) REVISE THE MEAN ROOF HEIGHT. ACCORDING TO THE | | WEBSITE STREET VIEW OF THIS HOUSE, IT LOOKS LIKE THE | | MEAN ROOF HEIGHT IS HIGHER THAN 15 FEET FOR THE UPPER | | ROOF OF THIS HOUSE. REVISE AS REQUIRED AND USE | | CORRESPONDING TABLE. SEC. R301.1 FBC-RESIDENTIAL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-02-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-01 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-01 |
Time |
12:30 |
Sent To |
|
|
Notes |
2018-02-01 13:49:23 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS. | | CODE: FBC 6TH EDITION (2017). | | | | 1- ROOF TILE NOA 12-0904.08 SUBMITTED WITH FLORIDA | | PRODUCT APPROVAL FL601-R13 EXPIRED ON 01/02/18. NEED TO | | PROVIDE CURRENT PRODUCT APPROVAL (2 COPIES) AS REQUIRED | | BY FAC 61G20-3.001. | | NOTE: I CONTACTED THE FLORIDA PRODUCT APPROVAL STAFF TO | | INFORM THEM ABOUT THIS ISSUE SO THEY CAN UPDATE THE | | INFORMATION. | | | | 2- TU PUS FLORIDA PRODUCT APPROVAL FL5259-R27: CLEARLY | | MARK WHICH UNDERLAYMENT SYSTEM ON PAGE 7 OF 14 IS GOING | | TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OF SEC. R301.2.1 FBC-RESIDENTIAL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-02-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-16 |
Time |
17:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-16 |
Time |
17:33 |
Sent To |
|
|
Notes |
2018-02-16 17:33:58 | RECEIVED E-MAIL FORM CONTRACTOR. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-02-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-13 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-12 |
Time |
11:30 |
Sent To |
|
|
Notes |
2018-02-13 11:30:31 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-02-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-07 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-05 |
Time |
10:26 |
Sent To |
I |
|
Notes |
2018-02-06 10:26:41 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-02-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-01 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-01-31 |
Time |
09:54 |
Sent To |
I |
|
Notes |
2018-02-01 09:55:01 | JGOMEZ |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |