Plan Review Details - Permit 18011256
Plan Review Stops For Permit 18011256 |
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2018-05-03 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-05-03 |
Time |
20:05 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-05-03 |
Time |
20:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2018-02-20 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-02-20 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-02-20 |
Time |
14:29 |
Sent To |
|
|
Notes |
2018-03-06 07:28:11 | DENIED | | | | 1. TANK-LESS WATER HEATER REQUIRES A SEPARATE PERMIT | | FOR GAS. INDICATE ON THE PLAN IF THE TANK-LESS WATER | | HEATER IS REPLACING AN EXISTING TANK-LESS WATER HEATER | | OR IS IT REPLACING A STORAGE TANK TYPE WATER HEATER OR | | IS IT BEING ADDED TO THE EXISTING HOT WATER SYSTEM? WPB | | AMENDMENTS TO THE FBC SEC 105.1 | | | | 2. SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING A PIPING | | RISER DIAGRAM AND A DRAWING SHOWING THE LOCATION OF TWH | | AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN | | RELATION TO THE WATER HEATER. INDICATE ON THE PLAN IF | | THE TANK-LESS WATER HEATER IS THE ONLY GAS APPLIANCE IN | | THIS SYSTEM? IF NOT, SUBMIT A COMPLETE GAS RISER | | SHOWING ALL PIPE SIZES, TYPE OF PIPE, THE DEVELOPED | | LENGTH TO THE FURTHEST GAS OUTLET, THE BTU LOAD OF EACH | | APPLIANCE, THE PSI OF THE SYSTEM, THE TYPE OF GAS AND | | THE TOTAL BTU LOAD ON THE SYSTEM. THESE REQUIREMENTS | | ALSO APPLY TO A NEW GAS SYSTEM. THE LOCATION OF THE | | WATER HEATER SHALL COMPLY WITH THE MANUFACTURER'S | | INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND | | DRAWN. WPB AMENDMENTS TO THE FBC SEC 107.2.1. | | | | 3. CPVC PIPE OUTSIDE IS NOT RECOMMENDED BY MANUFACTURES | | SPECIFICATION PLEASE TELL ME HOW YOU ARE GOING TO | | PROTECT IT FROM UV EXPOSURE. | | | | 4. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER THE 2017 FBC R | | SEC G2413.3. | | | | 5. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | ON THE PLAN PER 2017 FBC R SEC G2413.2. | | | | 6, SUMMIT TANKLESS WATER HEATERS MANUFACTURES | | SPECIFICATION AND MUST BE ON SITE FOR INSPECTION | | REFERRERS. | | | | 7. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | EACH PIPE SIZE. WPB AMENDMENTS TO THE FBC SEC 107.2.1. | | | | 8. SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | THE GAS CODE OR ANOTHER STANDARD THAT WAS USED IN THE | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC R SEC | | G2412.4, G2412.8, G2413.1, G2413.2, & G2413.3. | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | INSTALLATION. 2017 FBC FG 410.1. | | | | 10. THE CLAIMED VALUE APPEARS TO BE UNDERESTIMATED ON | | THE APPLICATION, PLEASE PROVIDE A BONA FIDE SIGNED | | CONTRACT. WPB AMENDMENTS TO THE FBC SEC 109.3 | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEW | | 561-805-6720 | | [email protected] | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2018-02-05 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-02-05 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-02-05 |
Time |
10:50 |
Sent To |
|
|
Notes |
2018-02-20 14:38:15 | DENIED | | | | 1. TANK-LESS WATER HEATER REQUIRES A SEPARATE PERMIT | | FOR GAS. INDICATE ON THE PLAN IF THE TANK-LESS WATER | | HEATER IS REPLACING AN EXISTING TANK-LESS WATER HEATER | | OR IS IT REPLACING A STORAGE TANK TYPE WATER HEATER OR | | IS IT BEING ADDED TO THE EXISTING HOT WATER SYSTEM? WPB | | AMENDMENTS TO THE FBC SEC 105.1 | | 2. SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING A PIPING | | RISER DIAGRAM AND A DRAWING SHOWING THE LOCATION OF TWH | | AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN | | RELATION TO THE WATER HEATER. INDICATE ON THE PLAN IF | | THE TANK-LESS WATER HEATER IS THE ONLY GAS APPLIANCE IN | | THIS SYSTEM? IF NOT, SUBMIT A COMPLETE GAS RISER | | SHOWING ALL PIPE SIZES, TYPE OF PIPE, THE DEVELOPED | | LENGTH TO THE FURTHEST GAS OUTLET, THE BTU LOAD OF EACH | | APPLIANCE, THE PSI OF THE SYSTEM, THE TYPE OF GAS AND | | THE TOTAL BTU LOAD ON THE SYSTEM. THESE REQUIREMENTS | | ALSO APPLY TO A NEW GAS SYSTEM. THE LOCATION OF THE | | WATER HEATER SHALL COMPLY WITH THE MANUFACTURER'S | | INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND | | DRAWN. WPB AMENDMENTS TO THE FBC SEC 107.2.1. | | 3. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER THE 2017 FBC R | | SEC G2413.3. | | 4. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | ON THE PLAN PER 2017 FBC R SEC G2413.2. | | 5. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | EACH PIPE SIZE. WPB AMENDMENTS TO THE FBC SEC 107.2.1. | | 6. SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | THE GAS CODE OR ANOTHER STANDARD THAT WAS USED IN THE | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC R SEC | | G2412.4, G2412.8, G2413.1, G2413.2, & G2413.3. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | [email protected] | | 561-805-6720 | | | 2018-02-05 10:51:23 | NO GAS PLAN HAVE BEEN SUBMITTED |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-05-03 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-05-03 |
Time |
20:06 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-05-02 |
Time |
15:35 |
Sent To |
|
|
Notes |
2018-05-02 15:35:40 | RESUB ROUTED TO LCRESPO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-02-20 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-02-20 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-02-14 |
Time |
13:55 |
Sent To |
|
|
Notes |
2018-02-15 13:55:35 | RESUB ROUTED TO LCRESPO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-02-05 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-02-05 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-02-05 |
Time |
10:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-02-05 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-02-05 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-01-31 |
Time |
13:36 |
Sent To |
|
|
Notes |
2018-02-01 13:36:44 | PLUMB <5K |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-05-03 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-05-03 |
Time |
20:05 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-05-03 |
Time |
20:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-02-20 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-02-20 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-02-20 |
Time |
14:30 |
Sent To |
|
|
Notes |
2018-02-20 14:37:23 | DENIED | | | | 1. TANK-LESS WATER HEATER REQUIRES A SEPARATE PERMIT | | FOR GAS. INDICATE ON THE PLAN IF THE TANK-LESS WATER | | HEATER IS REPLACING AN EXISTING TANK-LESS WATER HEATER | | OR IS IT REPLACING A STORAGE TANK TYPE WATER HEATER OR | | IS IT BEING ADDED TO THE EXISTING HOT WATER SYSTEM? WPB | | AMENDMENTS TO THE FBC SEC 105.1 | | 2. SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING A PIPING | | RISER DIAGRAM AND A DRAWING SHOWING THE LOCATION OF TWH | | AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN | | RELATION TO THE WATER HEATER. INDICATE ON THE PLAN IF | | THE TANK-LESS WATER HEATER IS THE ONLY GAS APPLIANCE IN | | THIS SYSTEM? IF NOT, SUBMIT A COMPLETE GAS RISER | | SHOWING ALL PIPE SIZES, TYPE OF PIPE, THE DEVELOPED | | LENGTH TO THE FURTHEST GAS OUTLET, THE BTU LOAD OF EACH | | APPLIANCE, THE PSI OF THE SYSTEM, THE TYPE OF GAS AND | | THE TOTAL BTU LOAD ON THE SYSTEM. THESE REQUIREMENTS | | ALSO APPLY TO A NEW GAS SYSTEM. THE LOCATION OF THE | | WATER HEATER SHALL COMPLY WITH THE MANUFACTURER'S | | INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND | | DRAWN. WPB AMENDMENTS TO THE FBC SEC 107.2.1. | | 3. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER THE 2017 FBC R | | SEC G2413.3. | | 4. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | ON THE PLAN PER 2017 FBC R SEC G2413.2. | | 5. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | EACH PIPE SIZE. WPB AMENDMENTS TO THE FBC SEC 107.2.1. | | 6. SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | THE GAS CODE OR ANOTHER STANDARD THAT WAS USED IN THE | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC R SEC | | G2412.4, G2412.8, G2413.1, G2413.2, & G2413.3. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | [email protected] | | 561-805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-02-05 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-02-05 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-02-05 |
Time |
10:29 |
Sent To |
|
|
Notes |
2018-02-05 10:40:43 | DENIED | | | | 1. TANK-LESS WATER HEATER REQUIRES A SEPARATE PERMIT | | FOR GAS. INDICATE ON THE PLAN IF THE TANK-LESS WATER | | HEATER IS REPLACING AN EXISTING TANK-LESS WATER HEATER | | OR IS IT REPLACING A STORAGE TANK TYPE WATER HEATER OR | | IS IT BEING ADDED TO THE EXISTING HOT WATER SYSTEM? WPB | | AMENDMENTS TO THE FBC SEC 105.1 | | | | 2. SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING A PIPING | | RISER DIAGRAM AND A DRAWING SHOWING THE LOCATION OF TWH | | AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN | | RELATION TO THE WATER HEATER. INDICATE ON THE PLAN IF | | THE TANK-LESS WATER HEATER IS THE ONLY GAS APPLIANCE IN | | THIS SYSTEM? IF NOT, SUBMIT A COMPLETE GAS RISER | | SHOWING ALL PIPE SIZES, TYPE OF PIPE, THE DEVELOPED | | LENGTH TO THE FURTHEST GAS OUTLET, THE BTU LOAD OF EACH | | APPLIANCE, THE PSI OF THE SYSTEM, THE TYPE OF GAS AND | | THE TOTAL BTU LOAD ON THE SYSTEM. THESE REQUIREMENTS | | ALSO APPLY TO A NEW GAS SYSTEM. THE LOCATION OF THE | | WATER HEATER SHALL COMPLY WITH THE MANUFACTURER'S | | INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND | | DRAWN. WPB AMENDMENTS TO THE FBC SEC 107.2.1. | | | | 3. CPVC PIPE OUTSIDE IS NOT RECOMMENDED BY MANUFACTURES | | SPECIFICATION PLEASE TELL ME HOW YOU ARE GOING TO | | PROTECT IT FROM UV EXPOSURE. | | | | 4. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER THE 2017 FBC R | | SEC G2413.3. | | | | 5. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | ON THE PLAN PER 2017 FBC R SEC G2413.2. | | | | 6, SUMMIT TANKLESS WATER HEATERS MANUFACTURES | | SPECIFICATION AND MUST BE ON SITE FOR INSPECTION | | REFERRERS. | | | | 7. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | EACH PIPE SIZE. WPB AMENDMENTS TO THE FBC SEC 107.2.1. | | | | 8. SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | THE GAS CODE OR ANOTHER STANDARD THAT WAS USED IN THE | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC R SEC | | G2412.4, G2412.8, G2413.1, G2413.2, & G2413.3. | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | INSTALLATION. 2017 FBC FG 410.1. | | | | 10. THE CLAIMED VALUE APPEARS TO BE UNDERESTIMATED ON | | THE APPLICATION, PLEASE PROVIDE A BONA FIDE SIGNED | | CONTRACT. WPB AMENDMENTS TO THE FBC SEC 109.3 | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEW | | 561-805-6720 | | [email protected] | | | | | | |
|
|
|