Plan Review Details - Permit 18011237
Plan Review Stops For Permit 18011237
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-02-23 Cont ID  
Sent By rmcdouga Date 2018-02-23 Time 15:28 Rev Time 0.00
Received By rmcdouga Date 2018-02-23 Time 15:28 Sent To  
Notes
2018-02-23 15:32:34R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND BARRIER
 CODE INSPECTION SHALL BE COMPLETED PRIOR TO FILLING THE
 POOL WITH WATER.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-02-14 Cont ID  
Sent By rmcdouga Date 2018-02-14 Time 16:51 Rev Time 0.00
Received By rmcdouga Date 2018-02-14 Time 16:51 Sent To  
Notes
2018-02-14 17:15:54PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) R4501.18 LADDERS AND STEPS. IN PRIVATE POOLS WHERE
 WATER DEPTH EXCEEDS 5 FEET (1524 MM), THERE SHALL BE
 LADDERS, STAIRS OR UNDERWATER BENCHES/SWIMOUTS IN THE
 DEEP END.
  
 2) R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND
 BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO
 FILLING THE POOL WITH WATER.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-02-14 Cont ID  
Sent By jleahy Date 2018-02-14 Time 09:39 Rev Time 0.00
Received By jleahy Date 2018-02-14 Time 09:39 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-02-26 Cont ID  
Sent By lcrespo Date 2018-02-26 Time 16:21 Rev Time 0.00
Received By lcrespo Date 2018-02-26 Time 16:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-02-15 Cont ID  
Sent By lcrespo Date 2018-02-15 Time 15:46 Rev Time 0.00
Received By lcrespo Date 2018-01-31 Time 15:10 Sent To  
Notes
2018-02-01 15:10:34REVISION ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-02-26 Cont ID  
Sent By lcrespo Date 2018-02-26 Time 16:21 Rev Time 0.00
Received By lcrespo Date 2018-02-26 Time 16:21 Sent To  
Notes
2018-02-26 16:22:4802/26/18 APPROVED BY PLUMBING AND SENT TO PROCESSING,
 LAC

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-02-15 Cont ID  
Sent By tklarge Date 2018-02-15 Time 15:45 Rev Time 0.00
Received By lcrespo Date 2018-02-15 Time 15:45 Sent To  
Notes
2018-02-15 15:46:29DENIED
  
 1. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL ON POOL HEATER AND THEY SHALL BE ON
 SITE FOR FINAL INSPECTION. NOT IN ORIGINAL PACKAGE WHEN
 FIRST SUBMITTED. WPB AMENDMENTS TO THE FBC SEC.
 107.2.1.
  
 2. SIGNATURE (OR SEAL, OR TITLE BLOCK, OR ALL THREE)
 ARE NOT IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE
 61G15-23.001, FLORIDA STATUTE 471.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 [email protected]
 561-805-6720
  

Review Stop Z ZONING
Rev No 1 Status P Date 2018-02-13 Cont ID  
Sent By ajones Date 2018-02-13 Time 14:40 Rev Time 0.00
Received By ajones Date 2018-02-07 Time 10:38 Sent To E
Notes
***NONE***