Plan Review Details - Permit 18011189
Plan Review Stops For Permit 18011189
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2018-07-07 Cont ID  
Sent By shill Date 2018-07-07 Time 15:31 Rev Time 0.00
Received By shill Date 2018-07-07 Time 15:31 Sent To  
Notes
2018-07-07 15:34:35****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. THE BUILDING PERMIT FOR THIS SITE HAS BEEN ISSUED.
 IT APPEARS THAT THIS PERMIT IS NO LONGER NEEDED.
  
 PLEASE CONTACT ME VIA EMAIL TO EITHER CONFIRM THAT THIS
 IS NOT NEEDED, OR TO REQUEST THAT IT BE ISSUED.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-03-14 Cont ID  
Sent By jwitmer Date 2018-03-14 Time 16:03 Rev Time 0.00
Received By jwitmer Date 2018-03-14 Time 15:48 Sent To  
Notes
2018-03-14 16:02:59CLEARING AND GRUBBING PERMIT.
 APPROVED WILL STAMP NEW PLANS ONCE THE ZONING APPROVAL
 IS GIVEN.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-03-02 Cont ID  
Sent By jwitmer Date 2018-03-02 Time 07:25 Rev Time 0.00
Received By jwitmer Date 2018-03-02 Time 07:09 Sent To  
Notes
2018-03-02 07:25:252017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 18011189
 ADD: 2115 MERCER AVE. PAVING
 CONT: M & M ASPHALT MAINTENANCE
 TEL: 561-588-0949
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: FRI. MARCH 02/2018
 ACTION: DENIED
  
 1) PERIMETER FENCING UNDER A SEPARATE PERMIT. PLEASE
 PROVIDE COMPLIANCE WITH: 2017 FBC-B 3306.5 BARRIERS.
 BARRIERS SHALL BE A MINIMUM OF 8 FEET (2438 MM) IN
 HEIGHT AND SHALL BE PLACED ON THE SIDE OF THE WALKWAY
 NEAREST THE CONSTRUCTION. BARRIERS SHALL EXTEND THE
 ENTIRE LENGTH OF THE CONSTRUCTION SITE.
  
 2) 2017 FBC0B 3306.2 WALKWAYS. A WALKWAY SHALL BE
 PROVIDED FOR PEDESTRIAN TRAVEL IN FRONT OF EVERY
 CONSTRUCTION AND DEMOLITION SITE UNLESS THE APPLICABLE
 GOVERNING AUTHORITY AUTHORIZES THE SIDEWALK TO BE
 FENCED OR CLOSED. WALKWAYS SHALL BE OF SUFFICIENT WIDTH
 TO ACCOMMODATE THE PEDESTRIAN TRAFFIC, BUT IN NO CASE
 SHALL THEY BE LESS THAN 4 FEET (1219 MM) IN WIDTH.
 WALKWAYS SHALL BE PROVIDED WITH A DURABLE WALKING
 SURFACE. WALKWAYS SHALL BE ACCESSIBLE IN ACCORDANCE
 WITH CHAPTER 11 AND SHALL BE DESIGNED TO SUPPORT ALL
 IMPOSED LOADS AND IN NO CASE SHALL THE DESIGN LIVE LOAD
 BE LESS THAN 150 POUNDS PER SQUARE FOOT (PSF).
  
 3) COMPLIED. PLEASE PROVIDE COMPLIANCE WITH: POLLUTION
 PREVENTION PLAN. 2017 FBC-B 3307.1 PROTECTION REQUIRED.
 ADJOINING PUBLIC AND PRIVATE PROPERTY SHALL BE
 PROTECTED FROM DAMAGE DURING CONSTRUCTION, REMODELING
 AND DEMOLITION WORK. PROVISIONS SHALL BE MADE TO
 CONTROL WATER RUNOFF AND EROSION DURING CONSTRUCTION OR
 DEMOLITION ACTIVITIES. THE PERSON MAKING OR CAUSING AN
 EXCAVATION TO BE MADE SHALL PROVIDE WRITTEN NOTICE TO
 THE OWNERS OF ADJOINING BUILDINGS ADVISING THEM THAT
 THE EXCAVATION IS TO BE MADE AND THAT THE ADJOINING
 BUILDINGS SHOULD BE PROTECTED. SAID NOTIFICATION SHALL
 BE DELIVERED NOT LESS THAN 10 DAYS PRIOR TO THE
 SCHEDULED STARTING DATE OF THE EXCAVATION.
  
 2014 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 109.3.10 IMPACT OF CONSTRUCTION. ALL
 CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL BE
 PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT THE
 CONDITION OF ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS
 PERMITTED TO AFFECT SAID PROPERTY PURSUANT TO CONSENT
 BY THE APPLICABLE PROPERTY OWNER, UNDER TERMS &
 CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY OWNER.
 THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF
 DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE
 STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION
 ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE
 WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY
 REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS
 OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS,
 CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL
 DEVELOPMENT, INCLUDING ADDITIONS, POOLS, PATIOS,
 DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING
 PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ.
 FT. OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A
 PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED
 DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A
 CERTIFICATION FROM A LICENSED ENGINEER SHALL BE
 SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL
 OF THE FINAL INSPECTION.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 4 Status P Date 2018-06-22 Cont ID  
Sent By hhall Date 2018-06-22 Time 09:26 Rev Time 0.00
Received By hhall Date 2018-06-22 Time 09:26 Sent To B
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 3 Status F Date 2018-05-07 Cont ID  
Sent By hhall Date 2018-05-07 Time 13:28 Rev Time 0.00
Received By hhall Date 2018-05-07 Time 13:28 Sent To I
Notes
2018-05-07 13:29:22FAILED - ADDRESS ZONING COMMENTS

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2018-03-12 Cont ID  
Sent By hhall Date 2018-03-12 Time 09:00 Rev Time 0.00
Received By hhall Date 2018-03-12 Time 08:59 Sent To B
Notes
2018-03-12 09:00:32SEE ZONING DETAILS

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2018-03-02 Cont ID  
Sent By shill Date 2018-03-02 Time 06:27 Rev Time 0.00
Received By shill Date 2018-03-02 Time 06:27 Sent To  
Notes
2018-03-02 06:28:00TRAVELLING WITH 18011188
 SEE REVIEWS UNDER 18011188
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2018-07-07 Cont ID  
Sent By shill Date 2018-07-07 Time 15:31 Rev Time 0.00
Received By shill Date 2018-06-14 Time 14:36 Sent To  
Notes
2018-06-14 14:37:06RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-05-07 Cont ID  
Sent By cpuell Date 2018-05-07 Time 13:58 Rev Time 0.00
Received By cpuell Date 2018-04-30 Time 14:57 Sent To  
Notes
2018-05-01 14:57:32ROUTED TO ZONING INBOX
 **TRAVELLING WITH 18011188**

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-03-14 Cont ID  
Sent By jwitmer Date 2018-03-14 Time 16:03 Rev Time 0.00
Received By jwitmer Date 2018-03-07 Time 11:18 Sent To  
Notes
2018-03-08 11:18:29RESUB ROUTED TO ZONING
 **TRAVELLING WITH 18011188**

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2018-03-02 Time   Rev Time 0.00
Received By lmarchan Date 2018-01-30 Time 12:56 Sent To  
Notes
2018-01-31 12:56:49ROUTED TO ZONING
 **TRAVELLINGW ITH 18011188**

Review Stop Z ZONING
Rev No 4 Status P Date   Cont ID  
Sent By   Date 2018-06-19 Time   Rev Time 0.00
Received By pgreilic Date 2018-06-19 Time 10:05 Sent To ENG
Notes
2018-06-19 10:05:49PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 3 Status F Date   Cont ID  
Sent By   Date 2018-05-04 Time   Rev Time 0.00
Received By pgreilic Date 2018-05-04 Time 16:54 Sent To ENG
Notes
2018-05-04 16:55:31SHOW APPROVED SIDEWALK CONNECTION ON ALL PLANS
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date   Cont ID  
Sent By   Date 2018-03-09 Time   Rev Time 0.00
Received By   Date 2018-03-09 Time   Sent To ENG
Notes
2018-03-09 10:31:461.) INCLUDE BIKE RACK DETAIL
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2018-02-13 Cont ID  
Sent By llouie Date 2018-02-13 Time 11:18 Rev Time 0.00
Received By pgreilic Date 2018-02-07 Time 10:26 Sent To  
Notes
2018-02-13 11:19:111.) SHOW LOCATION OF SIDEWALK CONNECTION FROM SIDEWALK
 ALONG MERCER TO SITE AS SHOWN IN APPROVED SITE PLAN
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]