Plan Review Details - Permit 18010865
Plan Review Stops For Permit 18010865
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-01-30 Cont ID  
Sent By jwitmer Date 2018-01-30 Time 13:05 Rev Time 0.00
Received By jwitmer Date 2018-01-30 Time 10:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-03-13 Cont ID  
Sent By jpearson Date 2018-03-13 Time 17:23 Rev Time 0.00
Received By jpearson Date 2018-03-13 Time 17:23 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-02-09 Cont ID  
Sent By jpearson Date 2018-02-09 Time 13:06 Rev Time 0.00
Received By jpearson Date 2018-02-09 Time 10:44 Sent To  
Notes
2018-02-09 13:06:14CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. NOTE 7 AND 8 ON SHEET E3.1 SHOWS 3 RUNS OF 500 KCMIL
 COPPER TO THE 1200 AMP MAIN DISCONNECT(MAIN 3 OF 3),
 AND THEN TO THE GUTTER. THE TOTAL AMPACITY OF THIS WIRE
 IS 380 X 3 = 1140 AMPS, WHICH IS UNDERSIZED. PROVIDE
 CORRECTION. NEC 240.4(C)
 2. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES
 EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN
 RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR
 LIGHTING PROPOSED TO COMPLY WITH CODE FOR THE SPACE
 WHERE THE REVISION OCCURS. FBC EC C405.4.2
 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. SHOW ON PLAN. NEC 250.94
 4. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS,
 DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD
 SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS
 (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF
 THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE
 REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET
 SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1,
 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-01-25 Cont ID  
Sent By wjolin Date 2018-01-25 Time 11:38 Rev Time 0.00
Received By scaldero Date 2018-01-25 Time 11:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2018-03-19 Time   Rev Time 0.00
Received By lmarchan Date 2018-03-08 Time 13:02 Sent To  
Notes
2018-03-09 13:02:22RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-03-07 Cont ID  
Sent By cpuell Date 2018-03-07 Time 11:24 Rev Time 0.00
Received By cpuell Date 2018-01-23 Time 14:00 Sent To  
Notes
2018-01-24 14:00:11C18

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-03-19 Cont ID  
Sent By ccole Date 2018-03-19 Time 15:46 Rev Time 0.00
Received By ccole Date 2018-03-19 Time 15:27 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-02-07 Cont ID  
Sent By ccole Date 2018-02-07 Time 09:33 Rev Time 0.00
Received By ccole Date 2018-02-07 Time 09:32 Sent To  
Notes
2018-02-07 09:36:521ST REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION
 CODES
 REVISION #18010865
 MASTER PERMIT #17060769
 2/7/18
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SUBMIT REVISED AC COOLING AND HEATING CALCULATIONS
 FRO THE CHANGE TO THE SYSTEMS- SECTION C403.2.1 FBC-14
 ENERGY CONSERVATION.
  
 2) THE REVISED ENERGYGAUGE COMPLIANCE FORM DOES NOT
 PROVIDE ANY INPUT DATA FOR THE NEW DEMISING WALLS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-02-14 Cont ID  
Sent By gjohnson Date 2018-02-14 Time 09:54 Rev Time 0.00
Received By gjohnson Date 2018-02-13 Time 16:02 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-03-06 Cont ID  
Sent By jroach Date 2018-03-06 Time 08:35 Rev Time 0.00
Received By jroach Date 2018-02-26 Time 16:50 Sent To PC
Notes
***NONE***