Plan Review Stops For Permit 18010496 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-03-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2018-03-22 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2018-03-22 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-01-31 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2018-01-31 |
Time |
11:52 |
Sent To |
|
|
Notes |
2018-01-31 14:09:21 | 1/31/2018. I SPOKE WITH ARCHITECT ALLEN BIRSE ABOUT: | | 5 STORY BUILDING, ELEVATOR LOBBY NOT REQUIED. | | | | 1) CODE ADDITION, 2017 FBC TO REDLINE | | 2) TYPO SHEET A-2 OFFICE DOOR FROM D TO C. REDLINED. | | JAMES A. WITMER BN, PX, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. | | WEST PALM BEACH. FL 33402 | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2018-02-19 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-02-19 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-02-19 |
Time |
12:16 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-03-20 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-03-20 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-03-19 |
Time |
15:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2018-01-19 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-01-19 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-01-19 |
Time |
12:01 |
Sent To |
|
|
Notes |
2018-01-19 15:39:08 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | INFORMATION: THE FLORIDA FIRE PREVENTION CODE IS NOW | | THE 6TH EDITION. PLEASE TAKE NOTE AND ADJUST YOUR | | REFERENCES AND REVIEWS ACCORDINGLY. | | | | | | | | 1) SHEET A 1 & A 2 - THE DEMO INDICATES EXISITNG 20 MIN | | DOORS; HOWEVER, DOOR "B" ON THE DOOR SCHULE HAS NO | | RATING. THESE DOORS ARE WITHIN A RATED WALL AND SHALL | | REFELCT THE REQUIRED RATING. | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | 2) SHEET A 2 & A 3 - THE DOOR SCHEDULE INDICATES THE | | DOOR "A" IN THE MAT COLUMN AS WD/GL. THE DIAGRAM OF | | DOOR "A" INDICATES ALL WOOD PANEL. | | | | PLEASE REVIEW AND CORRECT OR CLARIFY. | | | | | | | | 3) SHEET A 2 - THERE IS AN INDICATION OF DOORS "A" 180 | | SWING DOOR. THESE DOORS SERVE AN ELEVATOR LOBBY. IS THE | | EXISTING LOBBY REQUIRED TO BE RATED OR A SMOKE | | PARTITION. IF SO, THESE DOORS SHALL BE REQUIRED TO | | FUNCTION ACCORDINGLY. | | | | ADDITIONALLY, IF THE ELEVATOR SHAFT IS PRESSURIZED IT | | WILL AFFECT THE TYPE OF DOOR REQUIRED OF THE LOBBY. | | | | PLEASE REVIEW AND PROVIDE DETAILS AND/OR CORRECTIONS. | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-03-22 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-03-12 |
Time |
15:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-03-01 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-03-01 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-01-16 |
Time |
15:29 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2018-03-01 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-03-01 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-01-31 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-03-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-03-16 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-03-16 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-02-12 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-02-12 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-02-12 |
Time |
15:53 |
Sent To |
|
|
Notes |
2018-02-12 16:52:05 | 1ST REVIEW FBC-2017 MECHANICAL, EXISTING BUILDING CODES | | PERMIT #18010496 | | 2/12/18 | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) MINIMUM VENTILATION CALCULATIONS ARE REQUIRED TO | | VERIFY COMPLIANCE WITH SECTION 809.2 FBC-17 EXISTING | | BUILDING AND TABLE 403.1.1 FBC-17 MECHANICAL. | | | | 2) MISSING FIRE DAMPERS FOR DUCTS PENETRATING | | FIRE-RATED SEPARATION WALLS AT: ROOMS- 220/230, | | 225/230, 225/233, 251/239, CORRIDOR 203/212, 208/249, | | AND AT THE RETURN AIR GRILL AND THE EXISTING DUCT AT | | THE MECHANICAL ROOM WALLS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2018-03-01 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-03-01 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-03-01 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2018-01-26 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2018-01-26 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2018-01-26 |
Time |
11:00 |
Sent To |
|
|
Notes |
|
|