Plan Review Details - Permit 18010496
Plan Review Stops For Permit 18010496
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-03-22 Cont ID  
Sent By jwitmer Date 2018-03-22 Time 15:59 Rev Time 0.00
Received By jwitmer Date 2018-03-22 Time 15:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2018-01-31 Time 15:00 Rev Time 0.00
Received By jwitmer Date 2018-01-31 Time 11:52 Sent To  
Notes
2018-01-31 14:09:211/31/2018. I SPOKE WITH ARCHITECT ALLEN BIRSE ABOUT:
 5 STORY BUILDING, ELEVATOR LOBBY NOT REQUIED.
  
 1) CODE ADDITION, 2017 FBC TO REDLINE
 2) TYPO SHEET A-2 OFFICE DOOR FROM D TO C. REDLINED.
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-02-19 Cont ID  
Sent By jpearson Date 2018-02-19 Time 12:26 Rev Time 0.00
Received By jpearson Date 2018-02-19 Time 12:16 Sent To P
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-03-20 Cont ID  
Sent By pleduc Date 2018-03-20 Time   Rev Time 0.00
Received By pleduc Date 2018-03-19 Time 15:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2018-01-19 Cont ID  
Sent By pleduc Date 2018-01-19 Time   Rev Time 0.00
Received By pleduc Date 2018-01-19 Time 12:01 Sent To  
Notes
2018-01-19 15:39:08THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 INFORMATION: THE FLORIDA FIRE PREVENTION CODE IS NOW
 THE 6TH EDITION. PLEASE TAKE NOTE AND ADJUST YOUR
 REFERENCES AND REVIEWS ACCORDINGLY.
  
  
  
 1) SHEET A 1 & A 2 - THE DEMO INDICATES EXISITNG 20 MIN
 DOORS; HOWEVER, DOOR "B" ON THE DOOR SCHULE HAS NO
 RATING. THESE DOORS ARE WITHIN A RATED WALL AND SHALL
 REFELCT THE REQUIRED RATING.
  
 PLEASE REVIEW AND CORRECT.
  
  
  
 2) SHEET A 2 & A 3 - THE DOOR SCHEDULE INDICATES THE
 DOOR "A" IN THE MAT COLUMN AS WD/GL. THE DIAGRAM OF
 DOOR "A" INDICATES ALL WOOD PANEL.
  
 PLEASE REVIEW AND CORRECT OR CLARIFY.
  
  
  
 3) SHEET A 2 - THERE IS AN INDICATION OF DOORS "A" 180
 SWING DOOR. THESE DOORS SERVE AN ELEVATOR LOBBY. IS THE
 EXISTING LOBBY REQUIRED TO BE RATED OR A SMOKE
 PARTITION. IF SO, THESE DOORS SHALL BE REQUIRED TO
 FUNCTION ACCORDINGLY.
  
 ADDITIONALLY, IF THE ELEVATOR SHAFT IS PRESSURIZED IT
 WILL AFFECT THE TYPE OF DOOR REQUIRED OF THE LOBBY.
  
 PLEASE REVIEW AND PROVIDE DETAILS AND/OR CORRECTIONS.
  
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2018-03-22 Time 15:59 Rev Time 0.00
Received By lmarchan Date 2018-03-12 Time 15:00 Sent To  
Notes
2018-03-13 15:00:32C24

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-03-01 Cont ID  
Sent By thunt Date 2018-03-01 Time 09:20 Rev Time 0.00
Received By thunt Date 2018-01-16 Time 15:29 Sent To I
Notes
2018-01-18 15:29:24C24

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2018-03-01 Cont ID  
Sent By thunt Date 2018-03-01 Time 09:19 Rev Time 0.00
Received By thunt Date 2018-01-31 Time 11:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-03-19 Cont ID  
Sent By ccole Date 2018-03-16 Time 12:45 Rev Time 0.00
Received By ccole Date 2018-03-16 Time 11:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-02-12 Cont ID  
Sent By ccole Date 2018-02-12 Time 16:30 Rev Time 0.00
Received By ccole Date 2018-02-12 Time 15:53 Sent To  
Notes
2018-02-12 16:52:051ST REVIEW FBC-2017 MECHANICAL, EXISTING BUILDING CODES
 PERMIT #18010496
 2/12/18
  
 PLAN REVIEW RESULTS: DENIED.
  
  
 1) MINIMUM VENTILATION CALCULATIONS ARE REQUIRED TO
 VERIFY COMPLIANCE WITH SECTION 809.2 FBC-17 EXISTING
 BUILDING AND TABLE 403.1.1 FBC-17 MECHANICAL.
  
 2) MISSING FIRE DAMPERS FOR DUCTS PENETRATING
 FIRE-RATED SEPARATION WALLS AT: ROOMS- 220/230,
 225/230, 225/233, 251/239, CORRIDOR 203/212, 208/249,
 AND AT THE RETURN AIR GRILL AND THE EXISTING DUCT AT
 THE MECHANICAL ROOM WALLS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-03-01 Cont ID  
Sent By thunt Date 2018-03-01 Time 09:19 Rev Time 0.00
Received By thunt Date 2018-03-01 Time 09:20 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2018-01-26 Cont ID  
Sent By ajones Date 2018-01-26 Time 11:00 Rev Time 0.00
Received By ajones Date 2018-01-26 Time 11:00 Sent To  
Notes
***NONE***