Plan Review Stops For Permit 18010478 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-05-11 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-05-11 |
Time |
09:19 |
Sent To |
|
|
Notes |
2018-05-21 14:51:52 | PENDING UPDATE OF LICENSE & INSURANCE AS APPLICABLE FOR | | GC & TWO OF THE SUBS, INFORMED ALFONSO.. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-04-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-04-05 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-04-05 |
Time |
07:36 |
Sent To |
|
|
Notes |
2018-04-05 15:52:08 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) NEW COMMENT: A SURVEY WAS SUBMITTED, HOWEVER, THE | | PLANS INDICATE THAT THE EXISTING STORAGE STRUCTURE IS | | 16' X 26' AND THE MIDDLE BUILDING ON THE SURVEY IS | | 16.2' X 32'. PLEASE PROVIDE CLARIFICATION. | | | | 2) (PREVIOUS COMMENT.) PROVIDE THE WINDSPEED DATA AND | | EXPOSURE CATEGORY ON THE PLANS. SPECIFY THE REQUIRED | | COMPONENT AND CLADDING DESIGN PRESSURES ON THE PLANS. | | FBC-R301.2.1 | | | | 3) (PREVIOUS COMMENT.) IN ORDER TO CLARIFY THE WORK | | THAT WILL BE DONE, PROVIDE AN EXISTING FLOOR PLAN AND A | | PROPOSED FLOOR PLAN. FBC 107.2.1 | | | | 4) (PREVIOUS COMMENT.) SPECIFY THE LEVEL OF ALTERATION | | ON THE PLANS. FBC EXISTING BUILDING CHAPTER 5. THIS | | APPEARS TO BE A LEVEL 3 ALTERATION. NEW COMMENTS: THIS | | PROJECT IS A CHANGE OF USE THAT DOES NOT INVOLVE A | | CHANGE IN OCCUPANCY CLASSIFICATION PER FBC EXISTING | | BUILDING 1001.2.1. | | | | 5) COMPLIED. | | | | 6) COMPLIED. | | | | 7) COMPLIED. | | | | 8) COMPLIED. THE ALTERATION WILL NOT CREATE ANY | | ADDITIONAL LOADS TO THE EXISTING STRUCTURE. EVALUATION | | REPORT NOT REQUIRED. | | | | 9) COMPLIED. THE EXISTING WINDOWS AND DOORS WERE | | INSTALLED UNDER SEPARATE PERMIT # 91BA03568 AND | | #94008097. | | | | 10) (PREVIOUS COMMENT.) FBC - R 301.2.1.2 SUBMIT TWO | | COPIES OF AN INSTALLATION SCHEDULE AND KEY PLAN FOR THE | | STORM PANELS. SPECIFY THE OPENING SIZE, THE WIND | | PRESSURES, TYPE OF ANCHOR, ANCHOR SPACING, EDGE | | DISTANCE, PANEL LENGTH, PANEL SPAN, SEPARATION DISTANCE | | FROM PANEL TO GLASS AND THE APPLICABLE SECTION NUMBER | | FROM THE INSTALLATION DRAWINGS. I HAVE INCLUDED A LINK | | TO THE CONSTRUCTION SERVICES DEPARTMENT SITE THAT HAS | | MANY OF THE RELATED FORMS INCLUDING THE SCHEDULE FOR | | INSTALLATION OF OPENING PROTECTIVE DEVICES. | | HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/ | | | | 11) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | COMMENTS HAS BEEN ADDRESSED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-02-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-02-16 |
Time |
18:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-02-16 |
Time |
08:27 |
Sent To |
I |
|
Notes |
2018-02-16 08:32:26 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) BASED ON AERIAL PHOTOS, THERE APPEARS TO BE THREE | | BUILDINGS ON THIS LOT. SUBMIT TWO COPIES OF A RECENT | | SURVEY AND SITE PLAN THAT SHOWS ALL OF THE STRUCTURES | | THAT ARE LOCATED ON THE PROPERTY. IDENTIFY THE EXISTING | | UTILITY SHED THAT WILL BE CONVERTED TO HABITABLE SPACE | | AND THE DISTANCES FROM THE SHED TO PROPERTY LINES AND | | OTHER STRUCTURES ON THE PROPERTY. FBC-R302.1 | | | | 2) PROVIDE THE WINDSPEED DATA AND EXPOSURE CATEGORY ON | | THE PLANS. SPECIFY THE REQUIRED COMPONENT AND CLADDING | | DESIGN PRESSURES ON THE PLANS. FBC-R301.2.1 | | | | 3) IN ORDER TO CLARIFY THE WORK THAT WILL BE DONE, | | PROVIDE AN EXISTING FLOOR PLAN AND A PROPOSED FLOOR | | PLAN. FBC 107.2.1 | | | | 4) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS. FBC | | EXISTING BUILDING CHAPTER 5. THIS APPEARS TO BE A LEVEL | | 3 ALTERATION. | | | | 5) THE ENERGY CALCULATIONS ARE ON AN OUTDATED 2014 | | FORM. THE FBC SIXTH EDITION (2017) WENT INTO EFFECT ON | | JANUARY 1, 2018. ALL NEW PERMITS APPLIED FOR ON OR | | AFTER THAT DATE ARE REQUIRED TO COMPLY WITH AND | | REFERENCE THE FBC SIXTH EDITION (2017). | | | | 6) THE ENERGY CALCULATIONS SPECIFY A BEDROOM. THE CARD | | ROOM ON THE PLANS HAS A CLOSET AND APPEARS TO BE A | | BEDROOM. BEDROOMS/SLEEPING ROOMS ARE REQUIRED TO HAVE | | AN EMERGENCY ESCAPE AND RESCUE OPENING (FBC-R310) AND | | SMOKE ALARMS (FBC-R314). IF THIS ROOM WILL NOT BE USED | | AS A BEDROOM, THEN PRINT "THIS ROOM IS NOT TO BE USED | | FOR FOR SLEEPING PURPOSES" ON THE PLANS. | | | | 7) THE ENERGY CALCULATIONS SPECIFY A KITCHEN. THE | | ZONING CODE DOES NOT ALLOW A KITCHEN IN THIS ACCESSORY | | STRUCTURE. CORRECT THE ENERGY CALCULATIONS AND PRINT ON | | THE PLANS THAT A KITCHEN IS NOT ALLOWED. FBC 107.2.1 | | | | 8) FBC EXISTING BUILDING 907.4.1 SUBMIT TWO COPIES OF | | AN ENGINEERING EVALUATION AND ANALYSIS THAT ESTABLISHES | | THE STRUCTURAL ADEQUACY OF THE ALTERED STRUCTURE SHALL | | BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL AND | | SUBMITTED TO THE CODE OFFICIAL. | | | | 9) UNDER PREVIOUS PERMIT | | | | 10) FBC - R 301.2.1.2 SUBMIT TWO COPIES OF AN | | INSTALLATION SCHEDULE AND KEY PLAN FOR THE STORM | | PANELS. SPECIFY THE OPENING SIZE, THE WIND PRESSURES, | | TYPE OF ANCHOR, ANCHOR SPACING, EDGE DISTANCE, PANEL | | LENGTH, PANEL SPAN, SEPARATION DISTANCE FROM PANEL TO | | GLASS AND THE APPLICABLE SECTION NUMBER FROM THE | | INSTALLATION DRAWINGS. I HAVE INCLUDED A LINK TO THE | | CONSTRUCTION SERVICES DEPARTMENT SITE THAT HAS MANY OF | | THE RELATED FORMS INCLUDING THE SCHEDULE FOR | | INSTALLATION OF OPENING PROTECTIVE DEVICES. | | HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/ | | | | 11) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | COMMENTS HAS BEEN ADDRESSED. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-05-11 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-05-11 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-04-12 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2018-04-12 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2018-04-12 |
Time |
13:09 |
Sent To |
|
|
Notes |
2018-04-12 13:09:05 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE LOAD CALCULATION FOR MAIN SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | 2. PANEL B, PROVIDE GROUNDING ELECTRODE SYSTEM AS | | REQUIRED FOR A BUILDING OR STRUCTURE SUPPLIED BY A | | FEEDER OR BRANCH CIRCUIT. NEC 250.32; FBC RE3607.3 | | 3. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | MAIN BREAKER AT THE PANEL FOR PANEL B. NEC 225.31, | | 225.32 | | 4. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | FBC EC R404.1 | | 5. SMOKE ALARM MUST BE INSTALLED AT LEAST 3 FEET FROM | | BATHROOM DOOR. PROVIDE CORRECTION. FBC RE R314.3(4) | | 6. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | PHIL PETTY | | ELECTRICAL PLANS EXAMINER, CHIEF ELECTRICAL INSPECTOR | | 561-805-6742 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-02-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-02-09 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-02-09 |
Time |
10:31 |
Sent To |
|
|
Notes |
2018-02-09 10:31:40 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE LOAD CALCULATION FOR MAIN SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | 2. PANEL B, PROVIDE GROUNDING ELECTRODE SYSTEM AS | | REQUIRED FOR A BUILDING OR STRUCTURE SUPPLIED BY A | | FEEDER OR BRANCH CIRCUIT. NEC 250.32; FBC RE3607.3 | | 3. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | MAIN BREAKER AT THE PANEL FOR PANEL B. NEC 225.31, | | 225.32 | | 4. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | FBC EC R404.1 | | 5. SMOKE ALARM MUST BE INSTALLED AT LEAST 3 FEET FROM | | BATHROOM DOOR. PROVIDE CORRECTION. FBC RE R314.3(4) | | 6. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-05-21 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-05-21 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-05-18 |
Time |
13:10 |
Sent To |
|
|
Notes |
2018-05-21 13:10:25 | RESUB ROUTED TO SKENNEDY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-05-11 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-05-11 |
Time |
09:18 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-04-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-18 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-03-28 |
Time |
10:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-02-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-02-16 |
Time |
18:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-01-16 |
Time |
11:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2018-05-21 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-05-21 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-05-11 |
Time |
09:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-02-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-02-16 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-02-16 |
Time |
08:32 |
Sent To |
|
|
Notes |
2018-02-16 08:33:41 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2018-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-05-11 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-05-11 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2018-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-05-11 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-05-11 |
Time |
09:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2018-04-17 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-04-17 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-04-17 |
Time |
13:55 |
Sent To |
|
|
Notes |
2018-04-17 13:55:51 | 1 - PER FBC. SEC 107 MANUAL J AND PLANS NEED TO MATCH |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-02-07 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-02-07 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-02-07 |
Time |
15:24 |
Sent To |
|
|
Notes |
2018-02-07 15:27:14 | 1 - PER FBC. SEC 107 MANUAL J AND PLANS NEED TO MATCH |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-05-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-05-11 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-05-11 |
Time |
09:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-03-30 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-03-30 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-03-30 |
Time |
15:18 |
Sent To |
|
|
Notes |
2018-03-30 15:38:45 | 03/30/18 APPROVED BY PLUMBING AND PUT BACK IN R04, LAC |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-02-09 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-02-09 |
Time |
06:43 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-02-09 |
Time |
06:43 |
Sent To |
|
|
Notes |
2018-02-09 06:46:41 | 02/09/2018 PLUMBING 1ST REVIEW**DEINED** | | | | 1) YOU DO NOT SHOW THE REQUIRED VENT TO THE OUTDOORS ON | | THE ISOMETRIC SYSTEM AS REQUIRED PER FBC-P 904.1 | | | | 2) PIPE FITTINGS SHALL BE INSTALLED TO GUIDE SEWAGE AND | | WASTE IN THE DIRECTION OF FLOW. FBC-P 706.3 | | | | | | TIM HUNT | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | 561-805-6695 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-05-11 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
awooten |
Date |
2018-04-09 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-01-18 |
|
|
Cont ID |
|
Sent By |
AW |
Date |
2018-01-18 |
Time |
15:29 |
Rev Time |
|
Received By |
awooten |
Date |
2018-01-18 |
Time |
|
Sent To |
|
|
Notes |
2018-01-18 15:28:58 | ***************************************ZONING REVIEW | | FAILED**************************************** | | | | PROVIDE A COPY OF THE SURVEY SHOWING ALL EXISTING | | SETBACKS. FURTHER COMMENTS MAY FOLLOW. | | | | ALANA WOOTEN | | ASSOCIATE PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|