Plan Review Details - Permit 18010302
Plan Review Stops For Permit 18010302 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-02-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-02 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-02-02 |
Time |
14:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-01-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-01-18 |
Time |
19:01 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-01-18 |
Time |
16:32 |
Sent To |
|
|
Notes |
2018-01-18 16:36:40 | RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017) | | | | ORIGINAL COMMENT: | | 1- PROVIDE PRODUCT APPROVAL THAT MEETS THE DESIGN | | PRESSURES FOR EXPOSURE "C". DRAWINGS SUBMITTED WITH | | FLORIDA PRODUCT APPROVAL FL17347-R2 DON'T MEET THOSE | | DESIGN PRESSURES. | | FAC 61G20-3.001 | | | | RESPONSE: | | SAME DRAWING FL17347.15 WAS RE-SUBMITTED. IT DOESN'T | | MEET THE DESIGN PRESSURES SHOWN ON WIND-LOADS | | SUBMITTED. THE REPLACEMENT DOOR IS A SINGLE DOOR WITH | | SIDELITE ASSEMBLY. THEREFORE, THE DESIGN PRESSURES FOR | | A SINGLE DOOR WITH SIDELITE ASSEMBLY (OX/XO) SHOWN ON | | PRODUCT APPROVAL SUBMITTED DON'T MEET THE DESIGN | | PRESSURES. CONTRACTOR MARKED THE SINGLE DOOR ONLY. THIS | | IS INCORRECT. PROVIDE PRODUCT APPROVAL THAT MEETS THE | | DESIGN PRESSURES SHOWN ON THE WIND LOAD TABLE SUBMITTED | | FOR THE DOOR WITH SIDELITE ASSEMBLY. | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-01-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-01-11 |
Time |
17:57 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-01-11 |
Time |
17:48 |
Sent To |
|
|
Notes |
2018-01-11 18:14:57 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | CODE: FBC 6TH EDITION (2017) | | | | 1- WIND LOAD CALCULATIONS SUBMITTED ARE MARKED WITH THE | | DESIGN PRESSURES FOR AN INTERIOR ZONE IN EXPOSURE "B". | | ACCORDING TO SEC. R301.2.1.4 FBC-RESIDENTIAL, THIS | | BUILDING IS LOCATED IN EXPOSURE "C" NOT EXPOSURE. | | REVISE AS REQUIRED. OR PROVIDE COMPLETE ENGINEERING | | ANALYSIS WITH CALCULATIONS FOR ALL WIND DIRECTIONS. | | | | 2- PROVIDE PRODUCT APPROVAL THAT MEETS THE DESIGN | | PRESSURES FOR EXPOSURE "C". DRAWINGS SUBMITTED WITH | | FLORIDA PRODUCT APPROVAL FL17347-R2 DON'T MEET THOSE | | DESIGN PRESSURES. | | FAC 61G20-3.001 | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-02-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-02-02 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-01-29 |
Time |
14:34 |
Sent To |
I |
|
Notes |
2018-01-30 14:35:05 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-01-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-01-18 |
Time |
19:01 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-01-12 |
Time |
11:13 |
Sent To |
I |
|
Notes |
2018-01-16 11:13:58 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-01-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-01-11 |
Time |
18:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-01-10 |
Time |
10:44 |
Sent To |
I |
|
Notes |
2018-01-11 10:44:23 | BLDG <5K |
|
|
|