Plan Review Stops For Permit 18010142 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-02-22 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-02-22 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-02-22 |
Time |
07:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-02-14 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-02-14 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-02-14 |
Time |
15:28 |
Sent To |
|
|
Notes |
2018-02-14 16:05:33 | ****PLAN REVIEW COMMENTS**** | | | | ART LANGE BUILDING PLANS EXAMINER | | | | DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS STREET | | WEST PALM BEACH, FL 33402 | | | | 561-805-6718 [email protected] | | | | FBC FLORIDA BUILDING CODE 2017 6TH EDITION W/2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | 2017 6TH EDITION | | | | SECOND REVIEW: | | | | CODE CRITERIA | | | | 1. OK | | | | | | 2. IMPACT FEES OK | | | | | | | | 3. PRODUCT APPROVALS PARTIALLY ADDRESSED. | | | | (A) OK A PRODUCT APPROVAL WAS SUBMITTED FOR A LAWSON | | 3200 CASEMENT WINDOW. THIS WAS NOT SHOWN ON THE PLANS. | | | | (B) MISSING PAGE 3 THE MASONITE DOOR PRODUCT APPROVAL | | SUBMITTED HAS A MAXIMUM FRAME HEIGHT OF 81.875 INCHES. | | THE PLANS SHOW AN 84 INCH DOOR. UPDATE AS NEEDED. | | | | (C) NOT PROVIDED PROVIDE ROOFING PRODUCT APPROVALS | | ALONG WITH THE SELECTED ROOF ASSEMBLY USED. | | | | FBC 106.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | REGULATED BY DCA RULE 9N-3 SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 4. OK SIMPSON ATTACHMENT SHOWN AS LH 26 IS NOT FOUND. | | DID YOU MEAN LU 26. | | | | NEW COMMENT: | | | | IF YOU WISH TO HAVE THE PERMIT ISSUED WITHOUT THE ABOVE | | PRODUCT APPROVALS, ALTERNATIVELY YOU CAN SUBMIT THESE | | LATER AS A DEFERRED SUBMITTAL BY LISTING THEM ON THE | | PLANS AS DEFERRED SUBMITTALS. | | | | FBC 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | FOR REVIEW BY THE BUILDING OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | THE PERMIT PACKAGE. | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-01-12 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-01-12 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-01-11 |
Time |
16:10 |
Sent To |
|
|
Notes |
2018-01-12 08:23:18 | ****PLAN REVIEW COMMENTS**** | | | | ART LANGE BUILDING PLANS EXAMINER | | | | DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS STREET | | WEST PALM BEACH, FL 33402 | | | | 561-805-6718 [email protected] | | | | FBC FLORIDA BUILDING CODE 2017 6TH EDITION W/2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | 2017 6TH EDITION | | | | CODE CRITERIA | | | | 1. AS OF DECEMBER 31, 2017 THE CURRENT CODE CYCLE IS | | SHOWN ABOVE. UPDATE THIS IN THREE AREAS SHOWN ON A-1. | | | | 2. IMPACT FEES | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. | | | | 3. PRODUCT APPROVALS | | | | (A) A PRODUCT APPROVAL WAS SUBMITTED FOR A LAWSON 3200 | | CASEMENT WINDOW. THIS WAS NOT SHOWN ON THE PLANS. | | | | (B) THE MASONITE DOOR PRODUCT APPROVAL SUBMITTED HAS A | | MAXIMUM FRAME HEIGHT OF 81.875 INCHES. THE PLANS SHOW | | AN 84 INCH DOOR. UPDATE AS NEEDED. | | | | (C) PROVIDE ROOFING PRODUCT APPROVALS ALONG WITH THE | | SELECTED ROOF ASSEMBLY USED. | | | | FBC 106.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | REGULATED BY DCA RULE 9N-3 SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 4. SIMPSON ATTACHMENT SHOWN AS LH 26 IS NOT FOUND. DID | | YOU MEAN LU 26. | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | THE PERMIT PACKAGE. | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-02-14 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-02-14 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-02-14 |
Time |
15:00 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-01-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-01-22 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-01-22 |
Time |
13:48 |
Sent To |
|
|
Notes |
2018-01-22 13:48:16 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. NOTE 1 OF ELECTRICAL NOTES SPECIFIES USING THE 2011 | | NEC, WHICH IS NOT THE CURRENT CODE. PROVIDE CORRECTION. | | FBC PREFACE | | 2. NOTE 7 OF ELECTRICAL NOTES SPECIFIES THAT BEDROOM | | CIRCUITS SHALL HAVE "ARC PROTECTION". PER CODE: "BRANCH | | CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- AND | | 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, | | DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | SHALL BE AFCI PROTECTED." PROVIDE CORRECTION. NEC | | 210.12; FBC RE E3902.16 | | 3. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | E3609.3; FBC 107.2.1 | | 4. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC RE | | E3706.2, E3902 | | 5. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | 6. FOR DWELLING UNITS, ATTACHED GARAGES, AND DETACHED | | GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE | | LEVEL ACCESS. PROVIDE CORRECTION. NEC 210.70(A)(2)(B), | | FBC RE E3903.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2018-02-21 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-02-21 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-02-21 |
Time |
14:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2018-02-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-02-14 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-02-14 |
Time |
08:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2018-01-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-01-30 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-01-30 |
Time |
13:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-02-22 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-02-22 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-02-15 |
Time |
13:19 |
Sent To |
|
|
Notes |
2018-02-21 14:34:41 | 2/21 TO AL DESK | | | | | 2018-02-16 13:20:07 | RESUB ROUTED TO FMITTNER VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-02-14 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-02-14 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-02-05 |
Time |
11:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-02-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-02-05 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-01-05 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2018-02-14 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-02-14 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-02-14 |
Time |
15:27 |
Sent To |
|
|
Notes |
2018-02-14 15:28:48 | RECEIVED RECEIPT FROM PALM BEACH COUNTY | | MU-2018-002993 0000 | | NO FEES DUE. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-01-12 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-01-12 |
Time |
08:24 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-01-12 |
Time |
08:24 |
Sent To |
|
|
Notes |
2018-01-12 08:25:07 | ****PLAN REVIEW COMMENTS**** | | | | ART LANGE BUILDING PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS STREET | | WEST PALM BEACH, FL 33402 | | 561-805-6718 [email protected] | | | | | | IMPACT FEES | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-02-07 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-02-07 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-02-07 |
Time |
14:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-01-09 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-01-09 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-01-09 |
Time |
13:18 |
Sent To |
|
|
Notes |
2018-01-09 14:09:23 | MECHANICAL PLAN REVIEW FAIL | | | | 1 - HEAT LOAD REQUIRED FLORIDA BUILDING CODE ENERGY | | CONSERVATION SEC 403.6.1 | | | | CHRIS MONTELLO | | EMAIL - [email protected] | | 561-805-6733 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-02-14 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-02-14 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-02-14 |
Time |
14:44 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2018-01-22 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2018-01-22 |
Time |
07:04 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-01-22 |
Time |
07:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-02-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-02-14 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-02-14 |
Time |
08:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2018-01-30 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-01-30 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-01-30 |
Time |
13:55 |
Sent To |
|
|
Notes |
|
|