2018-04-25 08:26:39****PLAN REVIEW COMMENTS****
  
 ART LANGE BUILDING PLANS EXAMINER
  
 DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS STREET
 WEST PALM BEACH, FL 33402
  
 561-805-6718 [email protected]
  
  
 DENIED BY BUILDING SECOND REVIEW
  
  
 1) NOT PROVIDED: PROVIDE A DRAINAGE PLAN SHOWING
 COMPLIANCE WITH SEC. R401.3 FBC-RESIDENTIAL.
  
 PROVIDE TWO SETS OF DRAINAGE PLANS THAT SHOW COMPLIANCE
 WITH FBC-R401.3 DRAINAGE. SURFACE DRAINAGE SHALL BE
 DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER APPROVED
 POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS
 SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE
 BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2
 PERCENT AWAY FROM THE BUILDING.
  
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE
 BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2
 PERCENT AWAY FROM THE BUILDING.
  
 2) PARTIALLY COMPLIED
 FBC 107.2.5 THE CONSTRUCTION DOCUMENTS SUBMITTED WITH
 THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY A
 SITE PLAN SHOWING TO SCALE THE ESTABLISHED STREET
 GRADES AND THE PROPOSED FINISHED GRADES AND, AS
 APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN
 FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE
 WITH AN ACCURATE BOUNDARY LINE SURVEY.
  
 15) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT
 A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
 RE-SUBMITTAL PROCEDURE
 YOU ARE REQUIRED TO FILL OUT A RE-SUBMITTAL FORM TO BE
 SUBMITTED WITH THE CORRECTED PLANS AND/OR OTHER
 DOCUMENTS. THE PERMIT CLERK WILL RETRIEVE THE DENIED
 APPLICATION, PLANS AND OTHER DOCUMENTS FOR YOU. YOU ARE
 REQUIRED TO REMOVE THE OLD PLAN SHEETS THAT HAVE BEEN
 CORRECTED AND REPLACE THEM WITH THE NEW ONES. THE CLERK
 WILL PROVIDE YOU WITH A STAPLE REMOVER AND A STAPLER.
 ONE SET OF THE OLD PLAN SHEETS THAT HAVE BEEN REMOVED
 SHALL BE MARKED AS VOIDED AND RESUBMITTED ALONG WITH
 THE TWO (OR MORE) SETS THAT CONTAIN THE CORRECTED
 SHEETS. IF THERE ARE ANY SHEETS THAT HAVE BEEN STAMPED
 FOR COUNTY IMPACT FEES, HOA APPROVAL STAMPS OR OTHERS,
 RESUBMIT THOSE SHEETS.
 IF ALL OF THE PLAN SHEETS HAVE BEEN CORRECTED, THEN TWO
 (OR MORE) SETS OF THE NEW PLANS AND ANY OTHER DOCUMENTS
 SHALL BE SUBMITTED.
  
  
 _______________________________________________________
 _________________
  
 DEFERRED SUBMITTALS:
  
 THE FOLLOWING ITEMS HAVE BEEN LISTED ON THE COVER SHEET
 AS DEFERRED SUBMITTALS.
 WINDOWS
 ROOFING AND ROOF VENTS,
 DOORS
 ALUMINUM RAILINGS
 PRECAST LINTELS
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-01-19 Cont ID  
Sent By rmcdouga Date 2018-01-19 Time 18:35 Rev Time 0.00
Received By rmcdouga Date 2018-01-19 Time 13:02 Sent To I
Notes
2018-01-19 17:09:37PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PROVIDE TWO SETS OF DRAINAGE PLANS THAT SHOW
 COMPLIANCE WITH FBC-R401.3 DRAINAGE. SURFACE DRAINAGE
 SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER
 APPROVED POINT OF COLLECTION THAT DOES NOT CREATE A
 HAZARD. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER
 AWAY FROM FOUNDATION WALLS. THE GRADE SHALL FALL A
 MINIMUM OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET
 (3048 MM). EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR
 OTHER PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF
 FALL WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL
 BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE
 STRUCTURE. IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM)
 OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF
 2 PERCENT AWAY FROM THE BUILDING.
  
 2) FBC 107.2.5 THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES AND, AS APPLICABLE,
 FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN FLOOD
 ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN
 ACCURATE BOUNDARY LINE SURVEY. IN THE CASE OF
 DEMOLITION, THE SITE PLAN SHALL SHOW CONSTRUCTION TO BE
 DEMOLISHED AND THE LOCATION AND SIZE OF EXISTING
 STRUCTURES AND CONSTRUCTION THAT ARE TO REMAIN ON THE
 SITE OR PLOT.
  
 3) ON SHEET A-0, TYPE IV CONSTRUCTION IS SPECIFIED.
 TYPE IV IS HEAVY TIMBER CONSTRUCTION. THE CORRECT
 CONSTRUCTION TYPE FOR THIS PROJECT SHOULD BE TYPE V-B.
 FBC SECTION 602
  
 4) ON SHEET A-0, THE 2014 FBC RESIDENTIAL SHOULD BE
 LISTED WITH THE CODE SUMMARY. FBC-R101.2
  
 5) SHEET S-4 IS MISSING FROM BOTH SETS OF THE PLANS
 THAT WERE SUBMITTED. FBC 107.2.1
  
 6) SHOW THAT THE DOOR FROM THE GARAGE TO THE RESIDENCE
 COMPLIES WITH R302.5.1 OPENING PROTECTION. OPENINGS
 FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR
 SLEEPING PURPOSES SHALL NOT BE PERMITTED. OTHER
 OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE
 EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 13/8
 INCHES (35 MM) IN THICKNESS, SOLID OR HONEY-COMB-CORE
 STEEL DOORS NOT LESS THAN 13/8 INCHES (35 MM) THICK, OR
 20-MINUTE FIRE-RATED DOORS, EQUIPPED WITH A
 SELF-CLOSING DEVICE.
  
 7) A SMOKE ALARM IS REQUIRED ON THE FIRST FLOOR OF THE
 DWELLING. FBC-R314.3
  
 8) ON SHEET S-1, SOME OF THE VERTICAL REINFORCING BARS
 ARE NOT SHOWN ON THE FLOOR PLANS AT EXTERIOR CORNERS
 AND THE SIDES OF THE WINDOW OPENINGS. FBC-R609.3
  
 9) THE STEEL COLUMN SCHEDULE ON S-2 IS MISSING SOME
 DETAILS. THE WELDS FOR THE BASE AND CAP PLATES AND THE
 LOCATION AND LENGTH/EMBED DEPTHS OF THE NELSON STUDS.
 CLARIFY THE ABBREVIATION H.S. FROM THE STEEL COLUMN
 SCHEDULE.
  
 10) THE INFORMATION IN THE EGRESS WINDOW NOTE ON SHEET
 A-1 IS NOT CORRECT. R310.1.1 MINIMUM OPENING AREA. ALL
 EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A
 MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET.
 EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM
 NET CLEAR OPENING OF 5 SQUARE FEET.
 R310.1.2 MINIMUM OPENING HEIGHT. THE MINIMUM NET CLEAR
 OPENING HEIGHT SHALL BE 24 INCHES (610 MM).
 R310.1.3 MINIMUM OPENING WIDTH. THE MINIMUM NET CLEAR
 OPENING WIDTH SHALL BE 20 INCHES (508 MM).
  
 11) THE ENERGY FORMS CONTAIN ERRORS. THE BUILDER'S NAME
 IN INCORRECT. THE CONDITION FLOOR AREA DOES NOT MATCH
 THE PLANS. THE NUMBER OF BEDROOMS DOES NOT MATCH THE
 PLANS. THE VENT RATIO DOES NOT MATCH THE PLANS. FBC
 ENERGY CONSERVATION SECTION R101.5.1.1.2
  
 12) SHOW COMPLIANCE WITH FBC-RR807.1 ATTIC ACCESS.
 BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTION
 SHALL HAVE AN ATTIC ACCESS OPENING TO ATTIC AREAS THAT
 EXCEED 30 SQUARE FEET (2.8 M2) AND HAVE A VERTICAL
 HEIGHT OF 30 INCHES (762 MM) OR GREATER. THE VERTICAL
 HEIGHT SHALL BE MEASURED FROM THE TOP OF THE CEILING
 FRAMING MEMBERS TO THE UNDERSIDE OF THE ROOF FRAMING
 MEMBERS. THE ROUGH-FRAMED OPENING SHALL NOT BE LESS
 THAN 22 INCHES BY 30 INCHES (559 MM BY 762 MM) AND
 SHALL BE LOCATED IN A HALLWAY OR OTHER READILY
 ACCESSIBLE LOCATION. WHEN LOCATED IN A WALL, THE
 OPENING SHALL BE A MINIMUM OF 22 INCHES WIDE BY 30
 INCHES HIGH. WHEN THE ACCESS IS LOCATED IN A CEILING,
 MINIMUM UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL
 BE AT SOME POINT 30 INCHES (762 MM) ABOVE THE ACCESS
 MEASURED VERTICALLY FROM THE BOTTOM OF CEILING FRAMING
 MEMBERS. SEE SECTION M1305.1.3 FOR ACCESS REQUIREMENTS
 WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTICS.
  
 13) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT
 ROOFING MATERIALS, UPPER ROOF VENTS, WINDOW/GLASS
 TYPES, PRECAST LINTELS AND EXTERIOR DOOR TYPES.
  
 14) FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. THE
 VALUATION HAS BEEN ADJUSTED BASED ON THE CURRENT ICC
 VALUATION DATA.
  
 15) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT
 A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
 RE-SUBMITTAL PROCEDURE
 YOU ARE REQUIRED TO FILL OUT A RE-SUBMITTAL FORM TO BE
 SUBMITTED WITH THE CORRECTED PLANS AND/OR OTHER
 DOCUMENTS. THE PERMIT CLERK WILL RETRIEVE THE DENIED
 APPLICATION, PLANS AND OTHER DOCUMENTS FOR YOU. YOU ARE
 REQUIRED TO REMOVE THE OLD PLAN SHEETS THAT HAVE BEEN
 CORRECTED AND REPLACE THEM WITH THE NEW ONES. THE CLERK
 WILL PROVIDE YOU WITH A STAPLE REMOVER AND A STAPLER.
 ONE SET OF THE OLD PLAN SHEETS THAT HAVE BEEN REMOVED
 SHALL BE MARKED AS VOIDED AND RESUBMITTED ALONG WITH
 THE TWO (OR MORE) SETS THAT CONTAIN THE CORRECTED
 SHEETS. IF THERE ARE ANY SHEETS THAT HAVE BEEN STAMPED
 FOR COUNTY IMPACT FEES, HOA APPROVAL STAMPS OR OTHERS,
 RESUBMIT THOSE SHEETS.
 IF ALL OF THE PLAN SHEETS HAVE BEEN CORRECTED, THEN TWO
 (OR MORE) SETS OF THE NEW PLANS AND ANY OTHER DOCUMENTS
 SHALL BE SUBMITTED.
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-06-04 Cont ID  
Sent By ppetty Date 2018-06-04 Time 13:56 Rev Time 0.00
Received By ppetty Date 2018-06-04 Time 13:56 Sent To  
Notes
2018-06-04 13:56:38CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: OK, SEE COMMENTS BELOW.
  
 1. OK
 2. OK
 3. OK
 4. OK
 5. OK
 6. OK
 7. OK
 8. OK
 9. OK
 10. OK
 11. OK
 12. OK
 13. OK
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 PHIL PETTY
 ELECTRICAL PLANS EXAMINER, CHIEF ELECTRICAL INSPECTOR
 561-805-6742
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-04-17 Cont ID  
Sent By ppetty Date 2018-04-17 Time 11:13 Rev Time 0.00
Received By ppetty Date 2018-04-17 Time 11:13 Sent To  
Notes
2018-04-17 11:13:44CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. OK
 2. OK
 3. OK
 4. OK
 5. OK
 6. OK
 7. OK
 8. ADDRESS ON PERMIT APPLICATION IS 457 LILAC CT., PLAN
 SHOWS NO ADDRESS. PROVIDE CORRECTION. FBC 107.2.1
 9. OK
 10. OK
 11. FEED TO INTERIOR PANEL FROM DISCONNECT IS REQUIRED
 TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR, SIZED PER
 CODE. PROVIDE CORRECTION. NEC 250.122; FBC RE E3704.6,
 3607.3.1
 12. OK
 13. PROVIDE LOCATION OF METER AND DISCONNECT ON PLAN.
 FBC 107.2.
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 PHIL PETTY
 ELECTRICAL PLANS EXAMINER, CHIEF ELECTRICAL INSPECTOR
 561-805-6742
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-01-19 Cont ID  
Sent By jpearson Date 2018-01-19 Time 12:36 Rev Time 0.00
Received By jpearson Date 2018-01-19 Time 11:20 Sent To  
Notes
2018-01-19 12:28:41CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. BREAKER FOR WATER HEATER IS STATED AS 30 AMP, WHICH
 IS TOO LARGE FOR THIS LOAD. BREAKER SHOULD BE SIZED AT
 125% OF THE LOAD, WHICH IS A 25 AMP. PROVIDE
 CORRECTION. NEC 422.13; FBC RE3702.10
 2. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE3609.3
 3. PROVIDE GFCI PROTECTION FOR ALL OUTLETS IN GARAGE,
 INCLUDING THE GARAGE DOOR OPENER. NEC 210.8; FBC
 RE3902.2
 4. ALL EXTERIOR RECEPTACLES REQUIRE GFCI PROTECTION.
 PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.3
 5. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE
 PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH
 CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE
 CORRECTION. NEC 210.11(C)(3) , FBC RE3703.4
 6. ALL RECEPTACLES IN KITCHEN REQUIRE GFCI PROTECTION.
 PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.6
 7. PROVIDE GFCI PROTECTED RECEPTACLE ON 2ND FLOOR
 BALCONY. NEC 210.52(E)(3); FBC RE3901.7, E3902.3
 8. ADDRESS ON PERMIT APPLICATION IS 457 LILAC CT., PLAN
 SHOWS NO ADDRESS. PROVIDE CORRECTION. FBC 107.2.1
 9. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE.
 FBC EC R404.1
 10. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE4002.14
 11. FEED TO INTERIOR PANEL FROM DISCONNECT IS REQUIRED
 TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR, SIZED PER
 CODE. PROVIDE CORRECTION. NEC 250.122; FBC RE E3704.6,
 3607.3.1
 12. PROVIDE SMOKE ALARM ON EACH STORY OF THE DWELLING.
 FBC R314.3
 13. PROVIDE LOCATION OF METER AND DISCONNECT ON PLAN.
 FBC 107.2.1
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2018-06-29 Cont ID  
Sent By rmcdouga Date 2018-06-29 Time 11:15 Rev Time 0.00
Received By rmcdouga Date 2018-06-26 Time 15:28 Sent To  
Notes
2018-06-27 15:28:33IMPACT FEES ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-06-16 Cont ID  
Sent By shill Date 2018-06-16 Time 14:20 Rev Time 0.00
Received By shill Date 2018-05-24 Time 13:53 Sent To  
Notes
2018-05-25 13:53:45R31

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-04-25 Cont ID  
Sent By aclange Date 2018-04-25 Time 08:26 Rev Time 0.00
Received By aclange Date 2018-04-02 Time 13:41 Sent To  
Notes
2018-04-03 13:41:55R09

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-01-19 Cont ID  
Sent By rmcdouga Date 2018-01-19 Time 18:36 Rev Time 0.00
Received By rmcdouga Date 2017-12-28 Time 11:45 Sent To  
Notes
2017-12-29 11:45:44R06

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2018-06-29 Cont ID  
Sent By rmcdouga Date 2018-06-29 Time 11:15 Rev Time 0.00
Received By rmcdouga Date 2018-06-29 Time 11:04 Sent To I
Notes
2018-06-29 11:14:58MU-18-22368

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2018-04-25 Cont ID  
Sent By aclange Date 2018-04-25 Time 07:43 Rev Time 0.00
Received By aclange Date 2018-04-25 Time 07:42 Sent To  
Notes
2018-04-25 07:43:54BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-01-17 Cont ID  
Sent By rmcdouga Date 2018-01-17 Time 15:13 Rev Time 0.00
Received By rmcdouga Date 2018-01-17 Time 15:13 Sent To  
Notes
2018-01-17 15:13:54BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-01-19 Cont ID  
Sent By rmcdouga Date 2018-01-19 Time 16:56 Rev Time 0.00
Received By rmcdouga Date 2018-01-19 Time 16:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-06-14 Cont ID  
Sent By lcrespo Date 2018-06-14 Time 07:25 Rev Time 0.00
Received By lcrespo Date 2018-06-14 Time 07:25 Sent To  
Notes
2018-06-14 07:26:2106/14/18/ APPROVED BY PLUMBING AND PUT BACK IN R31, LAC

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-04-17 Cont ID  
Sent By thunt Date 2018-04-17 Time 18:24 Rev Time 0.00
Received By thunt Date 2018-04-17 Time 18:24 Sent To  
Notes
2018-04-17 18:34:5704/17/2018 2ND PLUMBING REVIEW**DENIED**
  
 1) ADDRESS MUST BE ON PLAN. FBC 107.2.1
  
 2) THE WATER HEATER ON YOUR FLORIDA ENERGY EFFICIENCY
 FORM R405-2014 IS SHOWING THE E.F AS .92. AS OF APRIL
 16, 2015 ALL RESIDENTIAL WATER HEATERS ARE REQUIRED TO
 BE A MIN .95 E.F UP TO 55 GALLONS. THIS IS DEFINED IN
 THE CODE OF FEDERAL REGULATION (CFR) 75 FR 2012.
  
 3) THE VERTICAL WET VENT THE KITCHEN IS CONNECTED TO
 ALSO SERVES THE 2ND FLOOR BATHROOM. FBC-R P 3108.4 ONLY
 ALLOWS VERTICAL VENT VENTING TO BE ON THE SAME FLOOR.
 PLEASE REVISE YOUR SANITARY ISOMETRIC DRAWING.
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-01-11 Cont ID  
Sent By thunt Date 2018-01-11 Time 06:50 Rev Time 0.00
Received By thunt Date 2018-01-11 Time 06:50 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status N Date 2018-06-16 Cont ID  
Sent By shill Date 2018-06-16 Time 14:20 Rev Time 0.00
Received By shill Date 2018-06-16 Time 14:20 Sent To  
Notes
2018-06-16 14:20:12PRODUCT APPROVALS REVIEWED BY DESIGNER OF RECORD ARE TO
 BE SUBMITTED WITH ROOF SUB PERMIT APPLICATION
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2018-04-25 Cont ID  
Sent By aclange Date 2018-04-25 Time 07:41 Rev Time 0.00
Received By aclange Date 2018-04-25 Time 07:41 Sent To  
Notes
2018-04-25 07:42:04NO PRODUCT APPROVALS WERE SUBMITTED FOR ROOFING
 MATERIALS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2018-01-19 Cont ID  
Sent By rmcdouga Date 2018-01-19 Time 14:04 Rev Time 0.00
Received By rmcdouga Date 2018-01-19 Time 13:02 Sent To  
Notes
2018-01-19 14:05:09NO PRODUCT APPROVALS WERE SUBMITTED FOR ROOFING
 MATERIALS.

Review Stop Z ZONING
Rev No 3 Status P Date 2018-06-01 Cont ID  
Sent By awooten Date 2018-06-01 Time   Rev Time 0.00
Received By awooten Date 2018-06-01 Time   Sent To  
Notes
2018-06-01 16:06:55******ZONING PROVISO******
 PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY,
 THE FOLLOWING CONDITIONS SHALL BE ADDRESSED:
 1. A LANDSCAPE PERMIT, WHICH INCLUDES A LANDSCAPE PLAN,
 SHALL BE SUBMITTED TO THE BUILDING DIVISION FOR REVIEW.
  
 2. THE LANDSCAPE MATERIAL SHOWN ON THE APPROVED
 LANDSCAPE PERMIT SHALL BE INSTALLED AND PASS A FINAL
 LANDSCAPE INSPECTION.
  
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2018-04-06 Cont ID  
Sent By awooten Date 2018-04-06 Time 09:37 Rev Time 0.00
Received By awooten Date 2018-04-05 Time 13:55 Sent To  
Notes
2018-04-06 09:37:42*****ZONING REVIEW FAILED********
  
 THE FOLLOWING LANDSCAPING REQUIREMENTS ARE REQUIRED FOR
 NEW RESIDENTIAL DEVELOPMENT:
  
 GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY
 DWELLING UNITS SHALL BE AS FOLLOWS:
 A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT
 TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF
 OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR
 EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.
 B. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PLAN WITH TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 THERE IS A SECOND OPTION OF SUBMITING A CONDITIONAL
 LANDSCAPING APPROVAL APPLICATION SO THAT THE PERMIT CAN
 BE APPROVED. HOWEVER, THE CERTIFICATE OF OCCUPANCY
 CANNOT BE GENERATED UNTIL A LANDSCAPE PLAN HAS BEEN
 SUBMITTED AND APPROVED. PLEASE CONTACT ME FOR MORE
 INFORMATION ON THE CONDITIONAL APPROVAL PROCESS.
  
 **************THE CONDITIONAL LANDSCAPE APPROVAL
 APPLIICATION MUST BE SUBMITTED AND PROCESSED, PRIOR TO
 APPROVAL.***********************
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By AV Date 2018-01-09 Time   Rev Time  
Received By   Date 2018-01-09 Time   Sent To  
Notes
2018-01-09 11:16:19*****ZONING REVIEW FAILED********
  
 THE FOLLOWING LANDSCAPING REQUIREMENTS ARE REQUIRED FOR
 NEW RESIDENTIAL DEVELOPMENT:
  
 GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY
 DWELLING UNITS SHALL BE AS FOLLOWS:
 A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT
 TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF
 OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR
 EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.
 B. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PLAN WITH TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 THERE IS A SECOND OPTION OF SUBMITING A CONDITIONAL
 LANDSCAPING APPROVAL APPLICATION SO THAT THE PERMIT CAN
 BE APPROVED. HOWEVER, THE CERTIFICATE OF OCCUPANCY
 CANNOT BE GENERATED UNTIL A LANDSCAPE PLAN HAS BEEN
 SUBMITTED AND APPROVED. PLEASE CONTACT ME FOR MORE
 INFORMATION ON THE CONDITIONAL APPROVAL PROCESS.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved