Plan Review Details - Permit 17120834
Plan Review Stops For Permit 17120834
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-12-28 Cont ID  
Sent By aclange Date 2017-12-28 Time 13:15 Rev Time 0.00
Received By aclange Date 2017-12-28 Time 13:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-01-23 Cont ID  
Sent By jpearson Date 2018-01-23 Time 10:12 Rev Time 0.00
Received By jpearson Date 2018-01-23 Time 08:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-12-29 Cont ID  
Sent By pleduc Date 2017-12-29 Time   Rev Time 0.00
Received By pleduc Date 2017-12-28 Time 16:03 Sent To  
Notes
2017-12-28 16:45:11THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THE DOOR SCHEDULE DID NOT INCLUDE HARDWARE ON THE
 EXIT DOORS. THE EXIT HARDWARE SHALL MEET THE
 REQUIREMENTS OF NFPA 101, CHAPTER 7, MEANS OF EGRESS.
  
 PER CHAPTER 38, NEW BUSINESS OCCUPANCIES
  
 38.2 MEANS OF EGRESS REQUIREMENTS.
 38.2.1 GENERAL.
 38.2.1.1 ALL MEANS OF EGRESS SHALL BE IN ACCORDANCE
 WITH CHAPTER 7 AND THIS CHAPTER.
  
 38.2.2.2 DOORS.
 38.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE
 PERMITTED.
 38.2.2.2.2* LOCKS COMPLYING WITH 7.2.1.5.5 SHALL BE
 PERMITTED ONLY ON PRINCIPAL ENTRANCE/EXIT DOORS.
  
 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES.
 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED
 READILY FROM THE EGRESS SIDE WHENEVER THE BUILDING IS
 OCCUPIED.
 7.2.1.5.2* THE REQUIREMENT OF 7.2.1.5.1 SHALL NOT APPLY
 TO DOOR LEAVES OF LISTED FIRE DOOR ASSEMBLIES AFTER
 EXPOSURE TO ELEVATED TEMPERATURE IN ACCORDANCE WITH THE
 LISTING, BASED ON LABORATORY FIRE TEST PROCEDURES.
 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE
 OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR
 OPERATION FROM THE EGRESS SIDE.
  
 7.2.1.5.5 KEY-OPERATED LOCKS.
 7.2.1.5.5.1 EXTERIOR DOOR ASSEMBLIES SHALL BE PERMITTED
 TO HAVE KEYOPERATED LOCKS FROM THE EGRESS SIDE,
 PROVIDED THAT ALL OF THE FOLLOWING CRITERIA ARE MET:
 (1) THIS ALTERNATIVE IS PERMITTED IN CHAPTERS 11
 THROUGH 43 FOR THE SPECIFIC OCCUPANCY.
 (2) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS
 THAN 1 IN. (25 MM) HIGH ON A CONTRASTING BACKGROUND
 THAT READS AS FOLLOWS IS LOCATED ON OR ADJACENT TO THE
 DOOR LEAF: THIS DOOR TO
 REMAIN UNLOCKED WHEN THE BUILDING IS OCCUPIED.
 (3) THE LOCKING DEVICE IS OF A TYPE THAT IS READILY
 DISTINGUISHABLE AS LOCKED.
 (4) A KEY IS IMMEDIATELY AVAILABLE TO ANY OCCUPANT
 INSIDE THE BUILDING WHEN IT IS LOCKED.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2018-01-31 Time   Rev Time 0.00
Received By lmarchan Date 2018-01-30 Time 16:08 Sent To  
Notes
2018-01-30 16:08:39GIVEN TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-01-24 Cont ID  
Sent By gjohnson Date 2018-01-24 Time 12:43 Rev Time 0.00
Received By gjohnson Date 2017-12-21 Time 10:10 Sent To  
Notes
2017-12-22 10:10:21C07

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2017-12-28 Cont ID  
Sent By aclange Date 2017-12-28 Time 13:15 Rev Time 0.00
Received By aclange Date 2017-12-28 Time 13:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-01-31 Cont ID  
Sent By ccole Date 2018-01-31 Time 09:48 Rev Time 0.00
Received By ccole Date 2018-01-31 Time 08:53 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-01-18 Cont ID  
Sent By ccole Date 2018-01-18 Time 09:57 Rev Time 0.00
Received By ccole Date 2018-01-18 Time 09:57 Sent To  
Notes
2018-01-18 10:12:501ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17120834
 1/18/18
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M2.1: PROVIDE THE FLEX DUCT SIZES.
  
 2) PROVIDE SIZING CALCULATIONS FOR THE NEW MINI SPLIT
 SYSTEM.
  
 3) VERIFY SMOKE DETECTORS ARE EXISTING AND FUNCTIONAL
 IN THE RETURN AIR PLENUM OR IN THE RETURN AIR SYSTEMS
 OF THE EXISTING RTU'S.
  
 4) M6.1: THE MIAMI-DADE NOA #13-1017.09 FOR THE ROOF
 STAND IS NO LONGER VALID. IT HAS BEEN SUPERSEDED BY
 #15-0902.05. PLEASE CORRECT AND PROVIDE TWO COPIES OF
 THE NOA WITH SHOP DRAWING APPROVAL STAMPS BY THE EOR.
  
 5) SHOW THE LOCATION OF THE NEW CONDENSER ON THE ROOF
 AND PROVIDE SITE SPECIFIC WIND LOAD DESIGN CRITERIA AND
 INSTALLATION DETAILS FOR THE STAND AND THE CONDENSER.
 THE NOA MAY BE MARKED UP TO SHOW THE APPLICABLE
 INSTALLATION DETAILS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-01-24 Cont ID  
Sent By gjohnson Date 2018-01-24 Time 12:43 Rev Time 0.00
Received By gjohnson Date 2018-01-24 Time 11:07 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-01-04 Cont ID  
Sent By JR Date 2018-01-04 Time 14:49 Rev Time 0.00
Received By jroach Date 2018-01-04 Time 14:49 Sent To  
Notes
***NONE***