Plan Review Details - Permit 17120819
Plan Review Stops For Permit 17120819
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-03-15 Cont ID  
Sent By rmcdouga Date 2018-03-15 Time 16:24 Rev Time 0.00
Received By rmcdouga Date 2018-03-15 Time 11:15 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-02-12 Cont ID  
Sent By rmcdouga Date 2018-02-12 Time 09:07 Rev Time 0.00
Received By rmcdouga Date 2018-02-09 Time 14:44 Sent To I
Notes
2018-02-12 09:07:23PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE DRAINAGE PLAN THAT WAS SUBMITTED DOES NOT SHOW
 HOW THE LOT WILL BE GRADE TO DIVERT THE SURFACE WATER
 TO THE APPROVED POINT OF COLLECTION OR STORM DRAIN.
 SUBMIT TWO SETS OF A SURFACE DRAINAGE PLAN. FBC-R401.3
 DRAINAGE. SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM
 SEWER CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION
 THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE
 GRADE SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN
 THE FIRST 10 FEET (3048 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE
 BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2
 PERCENT AWAY FROM THE BUILDING.
 FBC 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS
 SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE
 ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE
 AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES AND, AS APPLICABLE, FLOOD HAZARD AREAS,
 FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT SHALL BE
 DRAWN IN ACCORDANCE WITH AN ACCURATE BOUNDARY LINE
 SURVEY.
  
 2) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR THE THE HORIZONTAL
 SLIDING WINDOWS AND THE DOUBLE CASEMENT WINDOWS THAT
 ARE SPECIFIED ON THE PLANS.
  
 3) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-01-11 Cont ID  
Sent By rmcdouga Date 2018-01-11 Time 07:37 Rev Time 0.00
Received By rmcdouga Date 2018-01-09 Time 07:09 Sent To  
Notes
2018-01-10 19:03:55PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) ON SHEET A-000 THE CONSTRUCTION TYPE SHOULD BE V-B
 AND NOT R-3. R-3 IS THE TYPE OF OCCUPANCY NOT THE
 CONSTRUCTION TYPE. FBC CHAPTER 6
  
 2) SUBMIT TWO SETS OF A SURFACE DRAINAGE PLAN.
 FBC-R401.3 DRAINAGE. SURFACE DRAINAGE SHALL BE DIVERTED
 TO A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF
 COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE
 GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION
 WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES (152
 MM) WITHIN THE FIRST 10 FEET (3048 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE
 BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2
 PERCENT AWAY FROM THE BUILDING.
 FBC 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS
 SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE
 ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE
 AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES AND, AS APPLICABLE, FLOOD HAZARD AREAS,
 FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT SHALL BE
 DRAWN IN ACCORDANCE WITH AN ACCURATE BOUNDARY LINE
 SURVEY.
  
 3) THE SITE PLAN ON A-100 INCORRECTLY SPECIFIES THIS
 STRUCTURE AS TWO STORIES. PLEASE CORRECT. FBC 107.2.1
  
 4) THE DOOR FROM THE GARAGE TO THE RESIDENCE IS
 REQUIRED TO COMPLY WITH FBC-R302.5.1.
  
 5) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR THE ROOF TILE, THE
 HORIZONTAL SLIDING WINDOWS, THE DOUBLE CASEMENT
 WINDOWS, THE DOUBLE HUNG WINDOWS AND THE IN-SWINGING
 FRENCH DOORS.
  
 6) THE PLANS SHOW IN-SWINGING GLAZED FRENCH DOORS AND
 THE PRODUCT APPROVALS THAT WERE SUBMITTED (NOA NO.
 14-0908.07) ARE FOR OUT-SWING GLAZED FRENCH DOORS. FBC
 107.3.4 SUBMIT PRODUCT APPROVALS FOR THE DOORS SHOWN ON
 THE PLANS OR REVISE THE PLANS. FBC 107.3.4
  
 7) THE PLANS SPECIFY DOUBLE HUNG WINDOWS ON SHEET
 A-200. THE PRODUCT APPROVALS THAT WERE SUBMITTED (NOA
 NO. 16-1003.01) ARE FOR SINGLE HUNG WINDOWS. SUBMIT
 PRODUCT APPROVALS FOR THE DOUBLE HUNG WINDOWS THAT ARE
 SPECIFIED ON THE PLANS OR REVISE THE PLANS.
  
 8) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-01-11 Cont ID  
Sent By jleahy Date 2018-01-11 Time 15:17 Rev Time 0.00
Received By jleahy Date 2018-01-11 Time 15:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-03-15 Cont ID  
Sent By rmcdouga Date 2018-03-15 Time 16:29 Rev Time 0.00
Received By rmcdouga Date 2018-02-21 Time 15:40 Sent To  
Notes
2018-02-22 15:41:10RESUB ROUTED TO LLOUIE VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-02-12 Cont ID  
Sent By rmcdouga Date 2018-02-12 Time 09:07 Rev Time 0.00
Received By rmcdouga Date 2018-02-02 Time 15:48 Sent To  
Notes
2018-02-02 15:49:02RESUB ROUTED TO LLOUIE VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-01-12 Cont ID  
Sent By cpuell Date 2018-01-12 Time 16:18 Rev Time 0.00
Received By cpuell Date 2017-12-21 Time 10:15 Sent To  
Notes
2017-12-22 10:16:03R22

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2018-01-09 Cont ID  
Sent By rmcdouga Date 2018-01-09 Time 07:16 Rev Time 0.00
Received By rmcdouga Date 2018-01-09 Time 07:16 Sent To  
Notes
2018-01-09 07:19:50MU 2017-34645

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-01-03 Cont ID  
Sent By cmontell Date 2018-01-03 Time 15:11 Rev Time 0.00
Received By cmontell Date 2018-01-03 Time 14:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-01-09 Cont ID  
Sent By rmcdouga Date 2018-01-09 Time 13:05 Rev Time 0.00
Received By rmcdouga Date 2018-01-09 Time 11:24 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2018-03-15 Cont ID  
Sent By rmcdouga Date 2018-03-15 Time 16:25 Rev Time 0.00
Received By rmcdouga Date 2018-03-15 Time 16:24 Sent To  
Notes
2018-03-15 16:28:59ENTEGRA CONCRETE FLAT ROOF TILE, NOA NO.16-0112.07
 3M AH-160 ROOF TILE ADHESIVE, NOA NO. 14-0805.01
 POLYGLASS POLYSTICK UNDERLAYMENTS, NOA NO. 17-0614.22

Review Stop Z ZONING
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2018-02-27 Time   Rev Time 0.00
Received By llouie Date 2018-02-26 Time 15:58 Sent To B
Notes
2018-02-27 12:06:26ZONING PROVISOS:
  
 1.) ARCHITECTURAL FEATURE ABOVE GARAGE SHALL NOT
 PROJECT MORE THAN 3 FT. FROM THE WALL OF THE BUILDING.
  
 2.) SWIMMING POOL AND POOL DECK SHALL BE LOCATED
 OUTSIDE OF THE 5 FT. WIDE UTILITY EASEMENT LOCATED AT
 THE REAR OF THE PROPERTY.
  
 3.) A/C COMPRESSOR SHALL BE SCREENED FROM PUBLIC VIEW
 WITH LANDSCAPING.
  
 4.) SEPARATE PERMIT APPLICATIONS AND REVIEWS REQUIRED
 FOR: SWIMMING POOL, LANDSCAPING, IRRIGATION AND,
 DRIVEWAY AND WALKWAY.
  

Review Stop Z ZONING
Rev No 2 Status F Date 2018-02-08 Cont ID  
Sent By LL Date 2018-02-08 Time   Rev Time 0.00
Received By llouie Date 2018-02-07 Time 10:48 Sent To B
Notes
2018-02-08 14:42:36** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) A PORTION OF THE POOL/POOL DECK IS LOCATED WITHIN A
 5 FT. WIDE UTILITY EASEMENT LOCATED ALONG THE NORTH
 PROPERTY LINE (AS DEPICTED IN THE UPDATED SURVEY).
 PLEASE RELOCATE ALL PORTIONS OF THE POOL OUTSIDE OF THE
 EASEMENT.
  
  
 NOTES:
  
 * SEPARATE PERMIT APPLICATIONS AND REVIEWS REQUIRED
 FOR: SWIMMING POOL, DRIVEWAY/WALKWAY AND LANDSCAPING
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY
 (C.O.).
  
 * REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: SF7
  

Review Stop Z ZONING
Rev No 1 Status F Date 2018-01-12 Cont ID  
Sent By LL Date 2018-01-12 Time   Rev Time  
Received By llouie Date 2018-01-12 Time   Sent To  
Notes
2018-01-12 15:42:12** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) AN UPDATED SURVEY OF THE PROPERTY, SHOWING ANY
 EXISTING EASEMENTS, ETC., IS REQUIRED.
  
 2.) REQUIRED SIDE SETBACK IS A MINIMUM OF 5 FT. AND 15
 FT. TOTAL ON BOTH SIDES. THE SIDE SETBACKS PROVIDED IN
 THE SITE PLAN DOES NOT MEET THIS MINIMUM REQUIREMENT.
 [ZLDR S.94-72(A)(2)]
  
 3.) PER ZLDR S.94-304(D), THE SWIMMING POOL SHALL BE
 SETBACK AT LEAST 5 FT. FROM THE WATER?S EDGE TO THE
 REAR PROPERTY LINE. PLEASE PROVIDE DIMENSIONS TO
 DEMONSTRATE COMPLIANCE.
  
 4.) SHOW SETBACK DIMENSION FROM THE PROPOSED DRIVEWAY
 TO THE SIDE PROPERTY LINE.
  
 5.) THE REQUIRED FRONT YARD OF THE PROPERTY (THE AREA
 WITHIN 25 FT. OF THE FRONT PROPERTY LINE FROM GREGORY
 RD.) SHALL CONTAIN AT LEAST 1,000 SQ. FT. OF LANDSCAPED
 AREA. PLEASE PROVIDE PERVIOUS AND IMPERVIOUS SURFACE
 CALCULATIONS TO DEMONSTRATE COMPLIANCE. [ZLDR
 S.94-482(A)]
  
  
 NOTES:
  
 * SEPARATE PERMIT APPLICATIONS AND REVIEWS REQUIRED
 FOR: SWIMMING POOL, DRIVEWAY AND LANDSCAPING PRIOR TO
 THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY (C.O.).
  
 * REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: SF7
  


Account Summary | Usage Policy | Privacy Policy