Plan Review Stops For Permit 17120769 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2018-09-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-09-20 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-09-20 |
Time |
16:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2018-07-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-07-25 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-07-25 |
Time |
07:44 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2018-06-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-06-21 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-06-21 |
Time |
08:58 |
Sent To |
P |
|
Notes |
2018-06-21 08:57:58 | PLAN | | REVIEW COMMENTS | | | | 3RD REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE VALUE OF $9,200.00 STATED ON THE REVISION | | APPLICATION IS NOT ADEQUATE FOR THE ADDITIONAL SCOPE | | SPECIFIED ON THE DRAWING THAT WAS SUBMITTED. PROVIDE AN | | ITEMIZED COST BREAK DOWN FOR THE PROPOSED REVISED SCOPE | | OF WORK WITH AN ACCURATE TOTAL VALUE. FBC 109.3 | | BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES, | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE | | WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | 2) COMPLIED. | | | | 3) COMPLIED. | | | | 4) COMPLIED. | | | | 5)THE PRODUCT APPROVAL (NOA NO. 17-1108.23) THAT IS | | SPECIFIED ON THE PLANS FOR THE EXTERIOR DOORS IS FOR A | | BI-FOLDING WINDOW. PLEASE REVISE PLANS AND SUBMIT THE | | PRODUCT APPROVALS FOR THE OUTSWING EXTERIOR DOORS. FBC | | 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS FOR | | THOSE PRODUCTS WHICH ARE REGULATED BY FAC 61G20-3.001 | | PER FLORIDA STATUTE 553.842 (5) THAT HAVE BEEN REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA | | NUMBERS INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM | | DESIGN PRESSURES FOR EACH OF THE WINDOW/GLASS TYPES, | | STRUCTURAL MULLIONS AND EXTERIOR DOOR TYPES. IF THE | | WINDOWS ARE NOT LARGE MISSILE IMPACT RATED, THEN SUBMIT | | PRODUCT APPROVALS FOR THE STORM PANELS ALONG WITH A KEY | | PLAN AND INSTALLATION SCHEDULE. | | | | 6) COMPLIED. | | | | 7) COMPLIED. | | | | 8) COMPLIED. | | | | 9) THE APPROVED PLANS WILL NEED TO BE REVIEWED BY PALM | | BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES ARE DUE. | | SEE THE IMPACT FEE REVIEW FOR DETAILS. | | | | 10) COMPLIED. | | | | 11) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-05-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-05-01 |
Time |
19:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-04-25 |
Time |
17:55 |
Sent To |
I |
|
Notes |
2018-04-25 16:37:32 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE VALUE OF $9,200.00 STATED ON THE REVISION | | APPLICATION IS NOT ADEQUATE FOR THE ADDITIONAL SCOPE | | SPECIFIED ON THE DRAWING THAT WAS SUBMITTED. PROVIDE AN | | ITEMIZED COST BREAK DOWN FOR THE PROPOSED REVISED SCOPE | | OF WORK WITH AN ACCURATE TOTAL VALUE. FBC 109.3 | | BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES, | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE | | WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | 2) SUBMIT TWO SETS OF A FLOOR PLAN THAT ACCURATELY | | SHOWS AND DESCRIBES THE EXISTING CONDITIONS. FBC | | 107.2.1 (INDICATE ON THE PLANS THE 598 SQFT. OF STORAGE | | AREA THAT WILL BE CONVERTED TO LIVING AREA.) | | | | 3) THE PLANS THAT WERE SUBMITTED DO NOT MATCH THE PALM | | BEACH COUNTY PROPERTY APPRAISER'S RECORDS. SHOW THE | | ENTIRE STRUCTURE THAT IS UNDER ROOF ON THE PLANS | | INCLUDING CARPORTS, PORCHES, ETC. IF THE EXISTING | | STRUCTURE DOES NOT MATCH THE PROPERTY APPRAISER'S | | DIAGRAM, EXPLAIN THE DIFFERENCES. FBC 107.2.1 ( THE | | ROOM CONTAINING THE WATER HEATER AND WASHER IS NOT | | SHOWN ON THE PROPERTY APPRAISER'S DRAWINGS AND THE CITY | | HAS NO RECORD OF IT. UNLESS YOU CAN PROVIDE PROOF THAT | | IT WAS CONSTRUCTED WITH THE PROPER PERMITS AND | | INSPECTIONS, IT WILL NEED TO BE REMOVED OR BROUGHT INTO | | COMPLIANCE.) | | | | 4) COMPLIED. | | | | 5) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE | | WINDOW/GLASS TYPES, STRUCTURAL MULLIONS AND EXTERIOR | | DOOR TYPES. IF THE WINDOWS ARE NOT LARGE MISSILE IMPACT | | RATED, THEN SUBMIT PRODUCT APPROVALS FOR THE STORM | | PANELS ALONG WITH A KEY PLAN AND INSTALLATION SCHEDULE. | | | | 6) COMPLIED. | | | | 7) COMPLIED. | | | | 8) COMPLIED. | | | | 9) THE APPROVED PLANS WILL NEED TO BE REVIEWED BY PALM | | BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES ARE DUE. | | SEE THE IMPACT FEE REVIEW FOR DETAILS. | | | | 10) (NEW COMMENT) THE PERMIT THAT IS BEING REVISED WAS | | ISSUED UNDER THE 2014 FBC, FIFTH EDITION AND THE 2011 | | NEC. REVISE THE DESIGN CRITERIA ON THE PLANS | | ACCORDINGLY. | | | | 11) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-01-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-01-04 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-01-03 |
Time |
11:40 |
Sent To |
|
|
Notes |
2018-01-04 14:33:30 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE VALUE OF $9,200.00 STATED ON THE REVISION | | APPLICATION IS NOT ADEQUATE FOR THE ADDITIONAL SCOPE | | SPECIFIED ON THE DRAWING THAT WAS SUBMITTED. PROVIDE AN | | ITEMIZED COST BREAK DOWN FOR THE PROPOSED REVISED SCOPE | | OF WORK WITH AN ACCURATE TOTAL VALUE. FBC 109.3 | | BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES, | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE | | WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | 2) SUBMIT TWO SETS OF A FLOOR PLAN THAT ACCURATELY | | SHOWS AND DESCRIBES THE EXISTING CONDITIONS. FBC | | 107.2.1 | | | | 3) THE PLANS THAT WERE SUBMITTED DO NOT MATCH THE PALM | | BEACH COUNTY PROPERTY APPRAISER'S RECORDS. SHOW THE | | ENTIRE STRUCTURE THAT IS UNDER ROOF ON THE PLANS | | INCLUDING CARPORTS, PORCHES, ETC. IF THE EXISTING | | STRUCTURE DOES NOT MATCH THE PROPERTY APPRAISER'S | | DIAGRAM, EXPLAIN THE DIFFERENCES. FBC 107.2.1 | | | | 4) PROVIDE EXISTING AND PROPOSED AREA TABULATIONS ON | | THE PLANS. FBC 107.2.1 | | | | 5) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE | | WINDOW/GLASS TYPES, STRUCTURAL MULLIONS AND EXTERIOR | | DOOR TYPES. IF THE WINDOWS ARE NOT LARGE MISSILE IMPACT | | RATED, THEN SUBMIT PRODUCT APPROVALS FOR THE STORM | | PANELS ALONG WITH A KEY PLAN AND INSTALLATION SCHEDULE. | | | | 6) SHOW HOW THE BEDROOM WINDOWS WILL COMPLY WITH | | FBC-R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. | | BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM | | SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND | | RESCUE OPENING. | | | | FBC-R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE | | AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR | | OPENING OF 5.7 SQUARE FEET. EXCEPTION: GRADE FLOOR | | OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 | | SQUARE FEET. | | | | FBC-R310.1.2 MINIMUM OPENING HEIGHT. | | THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 | | INCHES. | | | | FBC-R310.1.3 MINIMUM OPENING WIDTH. | | THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES. | | | | 7) SPECIFY THE OCCUPANCY TYPE ON THE PLANS. FBC 107.2.1 | | | | 8) SPECIFY THE EXPOSURE CATEGORY OF THE PROJECT ON THE | | PLANS. FBC-R301.2.1.4 | | | | 9) THE APPROVED PLANS WILL NEED TO BE REVIEWED BY PALM | | BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES ARE DUE. | | SEE THE IMPACT FEE REVIEW FOR DETAILS. | | | | 10) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2018-07-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-07-26 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-07-26 |
Time |
10:38 |
Sent To |
|
|
Notes |
2018-07-26 11:02:54 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PROVISO!!!! | | | | LOAD CALCULATION IS NOT IN ACCORDANCE WITH ARTICLE 220 | | OF THE NEC, OR FBC RESIDENTIAL E3602.2 SERVICE LOAD. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2018-06-20 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-06-20 |
Time |
17:45 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-06-20 |
Time |
17:45 |
Sent To |
B |
|
Notes |
2018-06-20 17:51:50 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | | | OUTLET SPACING TO MEET CODE.. | | | | WALL SPACING/OUTLETS REQUIRED: | | | | E3901.2.1 SPACING. RECEPTACLES SHALL BE INSTALLED SO | | THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR | | LINE OF ANY WALL | | SPACE IS MORE THAN 6 FEET (1829 MM), FROM A RECEPTACLE | | OUTLET. [210.52(A)(1)] | | | | E3901.2.2 WALL SPACE. | | AS USED IN THIS SECTION, A WALL SPACE SHALL INCLUDE THE | | FOLLOWING: [210.52(A)(2)] | | .1.ANY SPACE THAT IS 2 FEET (610 MM) OR MORE IN WIDTH, | | INCLUDING SPACE MEASURED AROUND CORNERS, AND THAT IS | | UNBROKEN ALONG THE FLOOR LINE BY DOORWAYS AND SIMILAR | | OPENINGS, FIREPLACES, AND FIXED CABINETS. | | .2.THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR | | WALLS, EXCLUDING SLIDING PANELS. | | .3.THE SPACE CREATED BY FIXED ROOM DIVIDERS SUCH AS | | RAILINGS AND FREESTANDING BAR-TYPE COUNTERS | | | | VLAUE FOR THE ADDITIONAL WORK LOW. | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA | | OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | BUILDING OFFICIAL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-04-19 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-04-19 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-04-19 |
Time |
16:39 |
Sent To |
|
|
Notes |
2018-04-19 16:44:30 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | | | PLAN SHOWS NEW SERVICE, LOOKS TO BE MORE THAN 8' OF | | SERVIE CONDUCTOR INSTALLED WITHIN THE BUILDING. | | | | PLAN LOOKS TO BE A COMPLETE REWIRE? IS IT? | | | | NEED PANEL SCHEDULE | | | | IF THIS IS A REWIRE ADDITIONAL COMMENTS WILL BE GIVEN. | | | | IF THIS IS A REWIRE THEN THE VALUE OF THE WORK HAS NOT | | BEEN UPDATED FOR THE REWIRE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-01-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-01-04 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-01-04 |
Time |
16:57 |
Sent To |
I |
|
Notes |
2018-01-04 17:02:27 | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | NEED TO SHOW EXISTING FROM NEW ELECTRICAL WORK | | | | SHOW LOCATION OF SERVICE | | | | NO LIGHTING CIRCUITS OR OUTLETS ARE SHOWN | | | | OUTLET SPACING TO BE PER CODE. | | SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | REQUIREMENTS FOR OUTLETS. | | RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT | | MEASURED HORIZONTALLY ALONG | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | FROM A RECEPTACLE OUTLET. | | PROVIDE CORRECTION. NEC 210.52; FBC RE3901.2.1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2018-09-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-09-20 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-09-19 |
Time |
16:03 |
Sent To |
|
|
Notes |
2018-09-20 16:03:30 | IMPACT FEES ROUTED TO RMCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-07-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-07-26 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-07-11 |
Time |
13:52 |
Sent To |
|
|
Notes |
2018-07-19 13:52:50 | RESUB ROUTED TO TKLARGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-06-21 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-06-21 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-06-14 |
Time |
16:16 |
Sent To |
|
|
Notes |
2018-06-14 16:16:35 | RESUB ROUTED TO JLEAHY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-05-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-05-01 |
Time |
19:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-04-18 |
Time |
16:03 |
Sent To |
|
|
Notes |
2018-04-18 16:03:29 | RESUB ROUTED TO JLEAHY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-01-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-01-04 |
Time |
17:02 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-12-20 |
Time |
13:32 |
Sent To |
|
|
Notes |
2017-12-21 13:32:17 | REVISION ROUTED TO RMCDOUGAL |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2018-09-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-09-20 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-09-20 |
Time |
16:17 |
Sent To |
|
|
Notes |
2018-09-20 16:18:42 | MU-2018-27295, PAID $180.65 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-01-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-01-04 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-01-04 |
Time |
16:13 |
Sent To |
|
|
Notes |
2018-01-04 16:14:33 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2018-07-24 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-07-24 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-07-24 |
Time |
16:19 |
Sent To |
|
|
Notes |
2018-07-24 16:47:03 | 07/24/18 APPROVED BY PLUMBING AND SENT TO MCDOUGAL, LAC |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2018-06-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-06-21 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-06-21 |
Time |
11:21 |
Sent To |
I |
|
Notes |
2018-06-21 11:23:41 | SUBMIT A CODE COMPLIANT SANITARY RISER DIAGRAM FOR | | REVIEW. THERE ARE TOO MANY CODE VIOLATIONS ON THIS | | DRAWING TO LIST. WPB AMEND. TO FBC SEC. 107.3.5.3. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-04-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-04-25 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-04-25 |
Time |
16:39 |
Sent To |
|
|
Notes |
2018-04-25 17:51:06 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY PLUMBING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE PLUMBING RISER DIAGRAM CONTAINS NUMEROUS CODE | | VIOLATIONS. BASED ON THE PLUMBING DRAWING THAT WAS | | SUBMITTED IT APPEARS THE PERSON THAT PRODUCED THE | | PLUMBING RISER DIAGRAM IS NOT PROFICIENT WITH THESE | | DRAWINGS. PLEASE CONSULT A DESIGN PROFESSIONAL WITH A | | WORKING KNOWLEDGE OF PRODUCING PLUMBING CODE COMPLIANT | | RISER DIAGRAMS. FBC 107.2.1 | | | | 2) NO MORE THAN TWO WATER CLOSETS ARE ALLOWED TO BE WET | | VENTED. FBCR-P3108.1 | | | | 3) ONE OF THE WATER CLOSETS IS DRAWN WITH A TRAP. WATER | | CLOSETS HAVE INTEGRAL TRAPS. FBCR-P3201.6 FIXTURES | | SHALL NOT BE DOUBLE TRAPPED. | | | | 4) THE KITCHEN SINK IS DRAWN AS A VENT WITH A TRAP AT | | THE BOTTOM OF IT. THE P-TRAPS ARE LOCATED ON THE WASTE | | ARMS. FBCR-P3201.6 | | | | 5) THE WASHING MACHINE IS DRAWN WITH THE TRAP AT THE | | LEVEL OF THE BUILDING DRAIN. THE CLOTHES WASHER STAND | | PIPE TYPICALLY TIES INTO ITS VENT PIPE ABOVE THE FLOOR | | LEVEL BECAUSE THE STAND PIPE CAN BE NO LONGER THAN 42 | | INCHES. FBCR-P2706.2 | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-01-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-01-04 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-01-04 |
Time |
16:13 |
Sent To |
E |
|
Notes |
2018-01-04 16:34:46 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY PLUMBING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT TWO SETS OF A PLUMBING RISER DIAGRAM. | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2018-07-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-07-25 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-07-25 |
Time |
08:35 |
Sent To |
|
|
Notes |
2018-07-25 08:35:47 | NO ROOFING PRODUCT APPROVALS WERE SUBMITTED. |
|
|