Plan Review Stops For Permit 17120550 |
Review Stop |
AD |
ADDRESSING |
Rev No |
3 |
Status |
P |
Date |
2018-07-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-07 |
Time |
17:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-07 |
Time |
17:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2018-04-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-30 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-30 |
Time |
08:41 |
Sent To |
|
|
Notes |
2018-04-30 08:44:01 | 2ND REVIEW FBC 2014 EXISTING BUILDING | | | | APPLICANT TO ASSURE PERMIT APPLICATIONS CONTAIN CORRECT | | ADDRESS INFORMATION AS FOLLOWS: | | | | THE ADDRESS FOR THE SOUTH BUILDING IS 3805 BROADWAY | | WHICH INCLUDES THE NEW UNITS 1 THROUGH 15. | | THE NEW ADDRESS FOR THE NORTH BUILDING IS 3809 BROADWAY | | WHICH INCLUDES THE NEW UNITS 16 THROUGH 20. | | | | 2ND REVIEW - PLANS DO NOT INDICATE WHICH PLANS ARE FOR | | 3809 BROADWAY, OR UNIT NUMBERS. UNIT NUMBERS UTILIZE | | LETTERS, WHICH DO NOT CONFORM WITH CITY OF WEST PALM | | BEACH ADDRESSING STANDARDS. | | | | IF YOU WOULD LIKE TO CHANGE THE ADDRESSES OR UNIT | | NUMBERS, PLEASE CONTACT: | | | | [email protected] | | 561-494-1080 | | | | IF YOU DO NOT WISH TO CHANGE THE ADDRESSES OR UNIT | | NUMBERS, PLEASE REVISE PLANS ACCORDINGLY. | | |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2017-12-19 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-12-19 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-12-19 |
Time |
11:26 |
Sent To |
|
|
Notes |
2017-12-19 11:26:33 | 1ST REVIEW FBC 2014 EXISTING BUILDING | | | | APPLICANT TO ASSURE PERMIT APPLICATIONS CONTAIN CORRECT | | ADDRESS INFORMATION AS FOLLOWS: | | | | THE ADDRESS FOR THE SOUTH BUILDING IS 3805 BROADWAY | | WHICH INCLUDES THE NEW UNITS 1 THROUGH 15. | | THE NEW ADDRESS FOR THE NORTH BUILDING IS 3809 BROADWAY | | WHICH INCLUDES THE NEW UNITS 16 THROUGH 20. | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2018-09-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-09-02 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-09-02 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-07-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-07 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-07 |
Time |
17:34 |
Sent To |
|
|
Notes |
2018-07-07 17:34:33 | PROVISO - ADDRESS COMMENTS BY OTHER TRADES | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-04-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-30 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-30 |
Time |
08:20 |
Sent To |
|
|
Notes |
2018-04-30 08:26:44 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. FBC 107, SCOPE NOT CLEAR. PLANS STATE THAT ALL | | EXISTING FINISHES ARE TO REMAIN. APPLICATION STATES | | THAT CABINETS WILL BE INSTALLED. | | | | 2. FBC 107, SCOPE NOT CLEAR. APPLICATION STATES THAT 2 | | ADA BATHROOMS WILL BE INSTALLED. PLANS STATE ALL | | EXISTING FINISHES WILL REMAIN. ADA (FBC ACCESSIBILITY) | | IS APPLICABLE TO PLACES OF PUBLIC ACCOMMODATION. | | ARCHITECTURAL SHEETS NOT CLEAR AS TO WHERE THE TWO ADA | | BATHROOMS ARE PROPOSED. | | | | 3. FBC 107, SCOPE NOT CLEAR. I WAS TOLD THAT THIS IS A | | CHANGE OF OCCUPANCY, BUT I WAS UNABLE TO LOCATE THIS | | INFOROMATION ON THE PLANS. FBC EXISTING BUILDING | | 1001.2, PROVIDE A CODE SUMMARY - EXISTING OCCUPANCY, | | PROPOSED NEW OCCUPANCY. SHOW COMPLIANCE WITH ALL | | REQUIREMENTS. A COMPLETE REVIEW CANNOT BE DONE AT THIS | | TIME DUE TO LACK OF INFORMATION. | | | | 4. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY MAY BE | | REQUIRED. 561-233-5025 FOR MORE INFORMATION. | | | | 5. SEE ADDRESS REVIEW; PLANS NEED TO BE REVISED TO | | REFLECT CORRECT ADDRESSES AND UNIT NUMBERS. | | | | 6. FBC 109, PROVIDE A COST BREAKDOWN FOR ALL WORK | | PROPOSED. | | | | 7. A RESPONSE LETTER WOULD BE HELPFUL. NO LETTER WAS | | PROVIDED. NOT CLEAR ON PLANS HOW PREVIOUS COMMENTS WERE | | ADDRESSED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-01-02 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-01-02 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-01-02 |
Time |
14:23 |
Sent To |
|
|
Notes |
2018-01-02 14:25:59 | | | ****PLAN REVIEW COMMENTS**** | | | | ART LANGE BUILDING PLANS EXAMINER | | | | DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS STREET | | WEST PALM BEACH, FL 33402 | | | | 561-805-6718 [email protected] | | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION W/2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | 2015 5TH EDITION | | | | 1. DESCRIPTION OF WORK SHOWN IS FOR CABINET | | REPLACEMENT. THIS SHOULD BE SHOWN AS A CHANGE OF | | OCCUPANCY FROM R-1 TO R-2 AND INCLUDE A DESCRIPTION OF | | ALL WORK. FBC 105.3 | | | | 2. PERMIT VALUE APPEARS TOO LOW. ADJUST ACCORDINGLY. | | | | FBC 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE | | OPINION OF THE BUILDING OFFICIAL, THE CLAIMED VALUATION | | OF BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | BUILDING OFFICIAL. | | | | 3. ADDRESSING: | | | | ADJUST THE PLANS TO INCLUDE THE TWO FOLLOWING | | ADDRESSES. SOUTH BUILDING WILL BE 3805 BROADWAY AND THE | | NORTHERN BUILDING SHOULD BE SHOWN AS 3809 BROADWAY. | | THESE ADDRESSES HAVE BEEN UPDATED IN OUR SYSTEM | | ALREADY. | | | | 4. EXISTING BUILDING CODE: | | | | THIS PROJECT IS A CHANGE OF OCCUPANCY WITHIN A GROUP | | AND SHOULD SHOW COMPLIANCE WITH THE FOLLOWING AREAS OF | | THE EXISTING BUILDING CODE IN SECTION 1012. | | | | 1012.1 GENERAL. | | | | THE PROVISIONS OF THIS SECTION SHALL APPLY TO BUILDINGS | | OR PORTIONS THEREOF UNDERGOING A CHANGE OF OCCUPANCY | | CLASSIFICATION. THIS INCLUDES A CHANGE OF OCCUPANCY | | CLASSIFICATION WITHIN A GROUP AS WELL AS A CHANGE OF | | OCCUPANCY CLASSIFICATION FROM ONE GROUP TO A DIFFERENT | | GROUP. SUCH BUILDINGS SHALL ALSO COMPLY WITH SECTIONS | | 1002 THROUGH 1011. THE APPLICATION OF REQUIREMENTS FOR | | THE CHANGE OF OCCUPANCY SHALL BE AS SET FORTH IN | | SECTIONS 1012.1.1 THROUGH | | | | 1012.1.4. A CHANGE OF OCCUPANCY, AS DEFINED IN SECTION | | 202, WITHOUT A CORRESPONDING CHANGE OF OCCUPANCY | | CLASSIFICATION SHALL COMPLY WITH SECTION 1001.2. | | SEE ALSO SECTIONS 1012.2 FIRE PROTECTION SYSTEMS AND | | 1012.2.1 FIRE SPRINKLER SYSTEM. | | | | 5. INTERIOR ENVIRONMENT, INTERIOR SPACE DIMENSIONS. | | SEVERAL OF THE ROOMS ARE TOO SMALL OR ARE NOT PROVIDED | | WITH A CLOSET. | | | | FBC 1208.3 ROOM AREA. | | | | EVERY DWELLING UNIT SHALL HAVE NO FEWER THAN ONE ROOM | | THAT SHALL HAVE NOT LESS THAN 120 SQUARE FEET (13.9 M2) | | OF NET FLOOR AREA. OTHER HABITABLE ROOMS SHALL HAVE A | | NET FLOOR AREA OF NOT LESS THAN 70 SQUARE FEET (6.5 | | M2). | | | | FBC 1208.4 EFFICIENCY DWELLING UNITS. | | | | AN EFFICIENCY LIVING UNIT SHALL CONFORM TO THE | | REQUIREMENTS OF THE CODE EXCEPT AS MODIFIED HEREIN: | | | | 1) THE UNIT SHALL HAVE A LIVING ROOM OF NOT LESS THAN | | 220 SQUARE FEET (20.4 M2) OF FLOOR AREA. AN ADDITIONAL | | 100 SQUARE FEET (9.3 M2) OF FLOOR AREA SHALL BE | | PROVIDED FOR EACH OCCUPANT OF SUCH UNIT IN EXCESS OF | | TWO. | | | | 2) THE UNIT SHALL BE PROVIDED WITH A SEPARATE CLOSET. | | | | 3) THE UNIT SHALL BE PROVIDED WITH A KITCHEN SINK, | | COOKING APPLIANCE AND REFRIGERATION FACILITIES, EACH | | HAVING A CLEAR WORKING SPACE OF NOT LESS THAN 30 INCHES | | (762 MM) IN FRONT. LIGHT AND VENTILATION CONFORMING TO | | THIS CODE SHALL BE PROVIDED. | | | | 6. SOUND TRANSMISSION. SHOW HOW WALLS WILL COMPLY WITH | | THE FOLLOWING SECTION. | | | | FBC 1207.2 AIR-BORNE SOUND. | | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. PENETRATIONS OR OPENINGS IN CONSTRUCTION | | ASSEMBLIES FOR PIPING; ELECTRICAL DEVICES; RECESSED | | CABINETS; BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR | | EXHAUST DUCTS SHALL BE SEALED, LINED, INSULATED OR | | OTHERWISE TREATED TO MAINTAIN THE REQUIRED RATINGS. | | THIS REQUIREMENT SHALL NOT APPLY TO DWELLING UNIT | | ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT | | FITTING TO THE FRAME AND SILL. | | | | 7. PROVIDE THE USE OF THE UTILITY ROOM AND SHOW | | COMPLIANCE WITH FBC 509.4 SEPARATION AND PROTECTION. | | THE INCIDENTAL USES LISTED IN TABLE 509 SHALL BE | | SEPARATED FROM THE REMAINDER OF THE BUILDING OR | | EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM, OR BOTH, | | IN ACCORDANCE WITH THE PROVISIONS OF TABLE 508.4. | | | | 8. IMPACT FEE: BEFORE A PERMIT TO CONSTRUCT CAN BE | | ISSUED, IMPACT FEES, REQUIRED BY PALM BEACH COUNTY, | | SHALL BE PAID. UPON FINAL APPROVAL OF PLANS, ONE SET OF | | PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM BEACH | | COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH THE | | IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT MUST BE | | RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE THE | | BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | 9. ADDITIONAL INFORMATION REQUIRED. | | | | A) PROVIDE ELEVATIONS FOR THE KITCHEN AREA. | | | | B) SHOW LOCATIONS OF NEW WALLS. ARE THE WALLS AROUND | | THE KITCHENS NEW? IF SO PROVIDE WALL DETAILS. | | | | C) PROVIDE DETAIL FOR BATHROOM SHOWERS AND INCLUDE | | FRAMING SPACING. | | | | D) PARKING LOT REPAVING OR STRIPING WILL REQUIRE A | | SEPARATE PERMIT. | | | | E) PAGE A.3 SUBMITTED IS NOT LEGIBLE. | | | | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | THE PERMIT PACKAGE. | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2018-09-07 |
|
|
Cont ID |
|
Sent By |
dharvey |
Date |
2018-09-07 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
dharvey |
Date |
2018-09-07 |
Time |
14:47 |
Sent To |
|
|
Notes |
2018-09-07 14:48:45 | EXISTING SERVICE DRAWING PROVIDED SHOWING SINGLE AND | | THREE PHASE SERVICES. NELSON DOZIER ADVISED TO HAVE | | OWNER/CONTRACTOR PROVIDE PERMIT APPLICATIONS FOR ALL | | TRADES, HAVE IMPACT FEES PAID AND PLAN REVIEW IS | | COMPLETE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2018-08-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-08-20 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-08-20 |
Time |
13:09 |
Sent To |
|
|
Notes |
2018-08-20 13:09:54 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. 3 PHASE PANEL ON SINGLE PHASE SERVICE. (THIS HAS NOT | | BEEN ADDRESSED IN THE RISER DIAGRAM. RISER DIAGRAM MUST | | ACCURATELY REFLECT THE CURRENT ELECTRICAL SERVICE. HOW | | COULD A 3 PHASE SERVICE BE FED FROM A SINGLE PHASE | | SERVICE? PROVIDE ACCURATE RISER DIAGRAM, SHOWING ALL | | DETAILS OF SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD | | SERVICE, WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO | | ANY SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30; WPB FBC 107.2.1 | | | | NEW COMMENT: | | | | 2. PLAN HAS A BLOCK NOTE THAT STATES THERE IS NOW WORK | | TO BE INTENDED UNDER THIS PERMIT, BUT PLAN SHOWS | | EXHAUST FANS BEING INSTALLED. CORRECT DISCREPANCY. WPB | | FBC 107.2.1 | | 3. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | SERVICE IS ADEQUATE. LOAD CALCULATION SHOULD SHOW LOADS | | BASED ON THE WATTAGE DEMAND FOR EACH LOAD, AND THEN | | DIVIDED BY THE APPROPRIATE VOLTAGE. LOAD CALCULATION | | PROVIDED SWITCHES BETWEEN AMPERAGE OF LOADS AND | | WATTAGE, AND THEREFORE IS DIFFICULT TO UNDERSTAND. | | BASED ON THE NUMBERS PROVIDED, THE SERVICE TO SOUTH | | BUILDING IS OVERLOADED AS IS, AND NOW THERE WILL BE | | ADDITIONAL LOAD FOR EXHAUST FANS. THERE IS ALSO NO LOAD | | SHOWN FOR SMALL APPLIANCE CIRCUITS, WATER HEATERS, AND | | EXHAUST HOODS. NEC 215.2, 220, 408.30 | | 4. PROVIDE PANEL SCHEDULE(S) INDICATING ANY NEW OR | | ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE | | CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE APPLICABLE | | TO COMPLY WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, | | 215.5, 408.4; WPB FBC 107.3.5 | | 5. EACH OCCUPANT SHALL HAVE READY ACCESS TO ALL | | OVERCURRENT DEVICES PROTECTING THE CONDUCTORS SUPPLYING | | THAT OCCUPANCY. LOCATION OF ELECTRICAL PANELS NOT SHOWN | | ON PLAN, THEREFORE IT IS IMPOSSIBLE TO DETERMINE | | COMPLIANCE WITH THIS REQUIREMENT. PROVIDE CORRECTION. | | NEC 240.24(B) | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2018-06-27 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2018-06-27 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2018-06-27 |
Time |
13:06 |
Sent To |
|
|
Notes |
2018-06-27 13:07:37 | 3 PHASE PANEL FEED FROM SINGLE PHASE SERVICE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-04-27 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-04-27 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-04-27 |
Time |
08:41 |
Sent To |
|
|
Notes |
2018-04-27 09:00:22 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ADDRESS ON PLAN SHOW 3805 BROADWAY, BUT SHOWS BOTH | | BUILDINGS. THESE PLANS SHOULD BE SEPARATED SO THAT EACH | | PLAN HAS THE PROPER ADDRESS AND CORRESPONDING PLAN. | | PROVIDE CORRECTION. WPB FBC 107.2.1 | | 2. PROVIDE ELECTRICAL PLAN SHOWING ANY NEW WORK | | REQUIRED PER MECHANICAL COMMENTS. WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-01-03 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-01-03 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-01-03 |
Time |
07:11 |
Sent To |
|
|
Notes |
2018-01-03 07:41:17 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | SEALED BY THE LICENSED DESIGN PROFESSIONAL RESPONSIBLE | | FOR DESIGN. FS 471.003(2)(H); 471.025; FBC 107.2.1, | | 107.3.5 | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO INTERIOR | | PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM | | BONDING TERMINATION POINT. NEC 215.5, 230, 250.50, | | 250.94, 408.30 | | 3. PROVIDE PANEL SCHEDULE FOR EACH PANEL, INDICATING | | ANY NEW OR ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE | | FOR THESE CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE | | APPLICABLE TO COMPLY WITH CODE. NEC 210.8, 210.12, | | 215.5, 408.4 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2018-06-22 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-06-22 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-06-22 |
Time |
11:48 |
Sent To |
|
|
Notes |
2018-06-22 14:40:11 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) ANY WORK ON THE FIRE SPRINKLER OR SPRINKLER | | MONITORING ALARM SHALL BE DONE UNDER SEPARATE SHOP | | DRAWINGS. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2018-04-16 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-04-16 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-04-16 |
Time |
13:20 |
Sent To |
|
|
Notes |
2018-04-16 14:52:36 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) PREVIOUS FIRE COMMENTS WERE NOT ADDRESS. | | | | THE PREVIOUS FIRE COMMENTS ARE RESUBMITTED: | | | | ******************************************************* | | ******************************************************* | | *************** | | | | 1) THE APPLCATIONSTATES THE PROPOSED WORK IS TO REPLACE | | THE KITCHEN CABINETS. SHEET A 1 - STATES THAT THE | | PROPOSED WORK IS A CHANGE OF OCCUPANCY FROM MOTEL TO | | MULTI- RESIDENTIAL. | | | | PER THE FLORIDA FIRE PREVENTION CODE IT IS FROM | | EXISTING HOTEL TO NEW APARTMENT OCCUPANCY | | | | PLEASE CLARIFY. | | | | | | | | 2) THERE IS A REFERENCE INDICATING A FIRE ALARM IS NOT | | REQUIRED PER THE FBC; HOWEVER, A FIRE ALARM IS REQUIRED | | PER THE FLORIDA FIRE PREVENTION CODE, NFPA 101, CHPATER | | 30, NEW APARTMENT BUILDINGS. YOUR PROJECT INDICATES 14 | | UNITS. | | | | 30.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS. | | 30.3.4.1 GENERAL. | | 30.3.4.1.1 APARTMENT BUILDINGS FOUR OR MORE STORIES IN | | HEIGHT OR WITH MORE THAN 11 DWELLING UNITS, OTHER THAN | | THOSE MEETING THE REQUIREMENTS OF 30.3.4.1.2, SHALL BE | | PROVIDED WITH A FIRE ALARM SYSTEM IN ACCORDANCE WITH | | SECTION 9.6, EXCEPT AS MODIFIED BY 30.3.4.2 THROUGH | | 30.3.4.5. | | | | HOWEVER, | | | | 30.3.4.1.2 A FIRE ALARM SYSTEM SHALL NOT BE REQUIRED IN | | BUILDINGS WHERE EACH DWELLING UNIT IS SEPARATED FROM | | OTHER CONTIGUOUS DWELLING UNITS BY FIRE BARRIERS (SEE | | SECTION 8.3) HAVING A MINIMUM 1-HOUR FIRE RESISTANCE | | RATING, AND WHERE EACH DWELLING UNIT HAS EITHER ITS OWN | | INDEPENDENT EXIT OR ITS OWN INDEPENDENT STAIRWAY OR | | RAMP DISCHARGING AT THE FINISHED GROUND LEVEL. | | | | PLEASE REVIEW, CORRECT OR JUSTIFY WITH DETAILS AND/OR A | | SIGNED AND SEALED ENGINEEER REVIEW OF THE CONSTRUCTION, | | THAT THE CODE REQUIREMENTS ARE PROVIDED FOR. | | | | | | | | | | 3) THERE IS A REFERENCE INDICATING A FIRE SPRINKLER | | SYSTEM IS NOT REQUIRED PER THE FBC; HOWEVER, A FIRE | | SPRINKLER SYSTEM IS REQUIRED PER THE FLORIDA FIRE | | PREVENTION CODE, NFPA 101, CHPATER 30, NEW APARTMENT | | BUILDINGS. | | | | 30.3.5 EXTINGUISHMENT REQUIREMENTS. | | 30.3.5.1 ALL BUILDINGS SHALL BE PROTECTED THROUGHOUT BY | | AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM | | INSTALLED IN ACCORDANCE WITH 30.3.5.2. | | | | 30.3.5.2 WHERE AN AUTOMATIC SPRINKLER SYSTEM IS | | INSTALLED, EITHER FOR TOTAL OR PARTIAL BUILDING | | COVERAGE, THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE | | WITH SECTION 9.7, AS MODIFIED BY 30.3.5.3 AND 30.3.5.4. | | IN BUILDINGS FOUR OR FEWER STORIES ABOVE GRADE PLANE, | | SYSTEMS IN ACCORDANCE WITH NFPA 13R, STANDARD FOR THE | | INSTALLATION OF SPRINKLER SYSTEMS IN LOW-RISE | | RESIDENTIAL OCCUPANCIES, SHALL BE PERMITTED. | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY WITH ALL | | APPLICABLE FIRE CODE REFERENCES. | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-12-20 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-12-20 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-12-20 |
Time |
11:19 |
Sent To |
|
|
Notes |
2017-12-20 11:20:58 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | 1) THE APPLCATIONSTATES THE PROPOSED WORK IS TO REPLACE | | THE KITCHEN CABINETS. SHEET A 1 - STATES THAT THE | | PROPOSED WORK IS A CHANGE OF OCCUPANCY FROM MOTEL TO | | MULTI- RESIDENTIAL. | | | | PER THE FLORIDA FIRE PREVENTION CODE IT IS FROM | | EXISTING HOTEL TO NEW APARTMENT OCCUPANCY | | | | PLEASE CLARIFY. | | | | | | | | 2) THERE IS A REFERENCE INDICATING A FIRE ALARM IS NOT | | REQUIRED PER THE FBC; HOWEVER, A FIRE ALARM IS REQUIRED | | PER THE FLORIDA FIRE PREVENTION CODE, NFPA 101, CHPATER | | 30, NEW APARTMENT BUILDINGS. YOUR PROJECT INDICATES 14 | | UNITS. | | | | 30.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS. | | 30.3.4.1 GENERAL. | | 30.3.4.1.1 APARTMENT BUILDINGS FOUR OR MORE STORIES IN | | HEIGHT OR WITH MORE THAN 11 DWELLING UNITS, OTHER THAN | | THOSE MEETING THE REQUIREMENTS OF 30.3.4.1.2, SHALL BE | | PROVIDED WITH A FIRE ALARM SYSTEM IN ACCORDANCE WITH | | SECTION 9.6, EXCEPT AS MODIFIED BY 30.3.4.2 THROUGH | | 30.3.4.5. | | | | HOWEVER, | | | | 30.3.4.1.2 A FIRE ALARM SYSTEM SHALL NOT BE REQUIRED IN | | BUILDINGS WHERE EACH DWELLING UNIT IS SEPARATED FROM | | OTHER CONTIGUOUS DWELLING UNITS BY FIRE BARRIERS (SEE | | SECTION 8.3) HAVING A MINIMUM 1-HOUR FIRE RESISTANCE | | RATING, AND WHERE EACH DWELLING UNIT HAS EITHER ITS OWN | | INDEPENDENT EXIT OR ITS OWN INDEPENDENT STAIRWAY OR | | RAMP DISCHARGING AT THE FINISHED GROUND LEVEL. | | | | PLEASE REVIEW, CORRECT OR JUSTIFY WITH DETAILS AND/OR A | | SIGNED AND SEALED ENGINEEER REVIEW OF THE CONSTRUCTION, | | THAT THE CODE REQUIREMENTS ARE PROVIDED FOR. | | | | | | | | | | 3) THERE IS A REFERENCE INDICATING A FIRE SPRINKLER | | SYSTEM IS NOT REQUIRED PER THE FBC; HOWEVER, A FIRE | | SPRINKLER SYSTEM IS REQUIRED PER THE FLORIDA FIRE | | PREVENTION CODE, NFPA 101, CHPATER 30, NEW APARTMENT | | BUILDINGS. | | | | 30.3.5 EXTINGUISHMENT REQUIREMENTS. | | 30.3.5.1 ALL BUILDINGS SHALL BE PROTECTED THROUGHOUT BY | | AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM | | INSTALLED IN ACCORDANCE WITH 30.3.5.2. | | | | 30.3.5.2 WHERE AN AUTOMATIC SPRINKLER SYSTEM IS | | INSTALLED, EITHER FOR TOTAL OR PARTIAL BUILDING | | COVERAGE, THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE | | WITH SECTION 9.7, AS MODIFIED BY 30.3.5.3 AND 30.3.5.4. | | IN BUILDINGS FOUR OR FEWER STORIES ABOVE GRADE PLANE, | | SYSTEMS IN ACCORDANCE WITH NFPA 13R, STANDARD FOR THE | | INSTALLATION OF SPRINKLER SYSTEMS IN LOW-RISE | | RESIDENTIAL OCCUPANCIES, SHALL BE PERMITTED. | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY WITH ALL | | APPLICABLE FIRE CODE REFERENCES. | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2018-10-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-18 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-09 |
Time |
10:10 |
Sent To |
|
|
Notes |
2018-10-11 10:11:55 | IMPACT FEES ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-09-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-09-02 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-08-06 |
Time |
15:54 |
Sent To |
|
|
Notes |
2018-08-07 15:57:06 | C25 | | **TRAVELLING WITH 17120551** |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-07-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-12 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-06-18 |
Time |
16:36 |
Sent To |
|
|
Notes |
2018-06-20 16:36:51 | C10 | | **TRAVELLING WITH 17120551** |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-04-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-30 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-12 |
Time |
15:37 |
Sent To |
|
|
Notes |
2018-04-13 15:37:49 | C11 - **TRAVELLING WITH 17120551** |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-04-13 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2018-04-13 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-12-14 |
Time |
10:48 |
Sent To |
|
|
Notes |
2017-12-18 10:49:35 | TRAVELING WITH 17120551 | 2017-12-18 10:49:25 | C04 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
P |
Date |
2018-10-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-18 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-18 |
Time |
16:44 |
Sent To |
|
|
Notes |
2018-10-18 16:45:55 | IMPACT FEES $0.00 PLANS ARE STAMPED. CT |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2018-09-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-09-02 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-09-02 |
Time |
14:23 |
Sent To |
|
|
Notes |
2018-09-02 14:24:47 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2018-07-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-07 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-07 |
Time |
17:39 |
Sent To |
|
|
Notes |
2018-07-07 17:39:56 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | DUE TO CHANGE OF OCCUPANCY: | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | THAT FEES DUE, IF APPLICABLE, PROVIDED. | | | | AFTER ALL OTHER REVIEWS HAVE PASSED, CHECK OUT ONE SET | | OF PLANS TO TAKE TO THE COUNTY. | | | | 561-233-5025 FOR MORE INFORMATION | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-04-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-30 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-30 |
Time |
08:26 |
Sent To |
|
|
Notes |
2018-04-30 08:27:31 | SEE BUILDING REVIEW |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2018-08-23 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-08-23 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-08-23 |
Time |
15:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2018-06-26 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-06-26 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-06-26 |
Time |
13:02 |
Sent To |
|
|
Notes |
2018-06-26 14:01:12 | 3RD REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES | | PERMIT #17120550 | | 6/26/18 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M1: AS NOTED IN THE PREVIOUS REVIEW, | | MECHANICAL VENTILATION IS REQUIRED FOR THE BATHROOMS IN | | ACCORDANCE WITH TABLE 403.3 FBC-14 MECHANICAL. THIS IS | | A COMMERCIAL R2 OCCUPANCY, NOT A SINGLE FAMILY R3 | | OCCUPANCY WHERE NATURAL VENTILATION OF BATHROOMS IS | | ALLOWED PER THE FBC-14 RESIDENTIAL. PLEASE REVIEW THE | | FOLLOWING CODES THAT ARE ALSO APPLICABLE TO THE | | PROPOSED PROJECT: | | | | A) SECTION 1011.1 FBC-14 EXISTING BUILDING WHICH STATES | | A CHANGE OF OCCUPANCY SHALL HAVE LIGHT AND VENTILATION | | IN COMPLIANCE WITH THE FLORIDA BUILDING CODE. | | | | B) SECTION 1203.4.2.1 FBC-14 BUILDING WHICH STATES | | BATHROOMS SHALL BE "MECHANICALLY VENTILATED". | | | | 2) M1: THE MODEL NUMBER AEE12DT LISTED IN SCHEDULE IS | | NOT A FRIDGIDAIRE MODEL NUMBER. IT IS A GE NUMBER- | | PLEASE CORRECT. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2018-04-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-04-24 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-04-24 |
Time |
12:43 |
Sent To |
|
|
Notes |
2018-04-24 12:44:17 | 2ND REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES | | PERMIT #17120550 | | 4/24/18 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) COMMENTS #2, 3, & 4 FROM THE 1ST REVIEW STILL EXIST. | | I HAVE PRINTED THEM BELOW WITH SOME ADDITIONAL NOTES- | | PLEASE COMPLY. | | | | 2) SPACE HEATING SYSTEMS ARE REQUIRED FOR THE SUITES | | PER SECTION 309.1 FBC -14 MECHANICAL. PLEASE INDICATE | | HOW COMPLIANCE IS BEING MET. (THE NEW AC EQUIPMENT | | SCHEDULE ON THE M1 PLAN DOESN'T INDICATE IF THE SYSTEMS | | PROVIDE HEAT, AND NO CUT SHEETS FOR THE SYSTEMS HAVE | | BEEN PROVIDED FOR CLARIFICATION). | | | | 3) VENTILATION IS REQUIRED FOR THE SUITES- EITHER | | NATURALLY OR MECHANICALLY- PER SECTION 401.2. PLEASE | | INDICATE HOW COMPLIANCE IS BEING MET. (THE PLAN APPEARS | | TO SHOW NATURAL VENTILATION. PLEASE SEE SECTION 402.2 | | AN PROVIDE CALCULATIONS TO INDICATE COMPLIANCE). | | | | 4) EXHAUST VENTILATION SYSTEMS ARE REQUIRED FOR BOTH | | THE KITCHENS AND THE BATHROOMS PER TABLE 403.3. | | INDICATE HOW COMPLIANCE IS BEING MET. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-12-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-12-27 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-12-27 |
Time |
14:23 |
Sent To |
|
|
Notes |
2017-12-27 14:23:36 | 1ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES | | PERMIT #17120550 | | 12/27/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE A SCOPE OF WORK FOR MECHANICAL | | ALTERATIONS (IF APPLICABLE) WITH CORRESPONDING DRAWINGS | | AND DETAILS- SECTION 1009.1 EXISTING BUILDING CODE. | | | | 2) SPACE HEATING SYSTEMS ARE REQUIRED FOR THE SUITES | | PER SECTION 309.1 FBC -14 MECHANICAL. PLEASE INDICATE | | HOW COMPLIANCE IS BEING MET. | | | | 3) VENTILATION IS REQUIRED FOR THE SUITES- EITHER | | NATURALLY OR MECHANICALLY- PER SECTION 401.2. PLEASE | | INDICATE HOW COMPLIANCE IS BEING MET. | | | | 4) EXHAUST VENTILATION SYSTEMS ARE REQUIRED FOR BOTH | | THE KITCHENS AND THE BATHROOMS PER TABLE 403.3. | | INDICATE HOW COMPLIANCE IS BEING MET. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-07-10 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-07-10 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-07-10 |
Time |
14:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2018-04-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-04-24 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-04-21 |
Time |
10:58 |
Sent To |
|
|
Notes |
2018-04-24 07:44:06 | NO PLUMBING APPROVED UNDER THIS PERMIT/GPJ |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-01-10 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-01-08 |
Time |
18:10 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-01-08 |
Time |
15:39 |
Sent To |
|
|
Notes |
2018-01-10 08:26:30 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: | | | | 1. SHT.A-4 AND A-5 PLEASE SHOW GRAB BARS TO BE MEASURED | | TO THE TOP OF THE GRIPPING SURFACE. PER FBC PL 609.4 | | | | 2. SHOW DIMENSIONS FOR FBC ACC 604.7 DISPENSERS. | | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE | | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 | | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND | | SHALL NOT BE LOCATED BEHIND GRAB BARS | | | | 3. PLEASE SHOW HOT AND COLD AND LABEL PIPING ON WATER | | RISER. PER WPB AMEND TO FBC 107.2.1 | | | | 4. BECAUSE OF THE AGE OF THE BUILDING AND THIS BEING A | | CHANGE OF OCCUPANCY THE SAFETY PIPING ON THE WATER | | HEATER WILL NEED TO BE BROUGHT UP TO CODE, THE T+P | | RELIEF VALVE AND DRAIN LINE AND THERMAL EXPANSION. PER | | FBC PL CH 504 AND 607.3 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2018-07-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-07-12 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-07-12 |
Time |
08:58 |
Sent To |
|
|
Notes |
2018-07-12 08:58:33 | OK PER PG, SEE REVIEW UNDER 17120551, SEE STAMP ON PLAN | | TWO PERMITS TRAVELLING TOGETHER, ONE SET OF PLANS | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-04-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-30 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-30 |
Time |
08:17 |
Sent To |
|
|
Notes |
2018-04-30 08:17:56 | OK PER PG, SEE REVIEW UNDER 17120551, SEE STAMP ON PLAN | | TWO PERMITS TRAVELLING TOGETHER, ONE SET OF PLANS | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
PG |
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
ajones |
Date |
2018-01-16 |
Time |
15:06 |
Sent To |
|
|
Notes |
|
|