Plan Review Details - Permit 17120398
Plan Review Stops For Permit 17120398
Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-07-26 Cont ID  
Sent By tklarge Date 2018-07-26 Time 12:45 Rev Time 0.00
Received By tklarge Date 2018-07-16 Time 13:29 Sent To  
Notes
2018-07-17 13:29:11RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-06-01 Cont ID  
Sent By thunt Date 2018-06-01 Time 16:50 Rev Time 0.00
Received By thunt Date 2018-05-29 Time 15:38 Sent To I
Notes
2018-05-30 15:39:11RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-28 Cont ID  
Sent By thunt Date 2017-12-28 Time 07:51 Rev Time 0.00
Received By thunt Date 2017-12-11 Time 13:17 Sent To  
Notes
2017-12-12 13:18:04PLUMB <5K

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-07-26 Cont ID  
Sent By tklarge Date 2018-07-26 Time 12:44 Rev Time 0.00
Received By tklarge Date 2018-07-26 Time 12:08 Sent To I
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-06-01 Cont ID  
Sent By thunt Date 2018-06-01 Time 16:41 Rev Time 0.00
Received By thunt Date 2018-06-01 Time 16:41 Sent To  
Notes
2018-06-01 16:42:5706/01/2018 2ND PLUMBING REVIEW**DENIED**
  
 1) CONSTRUCTION DOCUMENTS SHALL BE DRAWN ON AND WITH
 SUITABLE MATERIAL. NO PENCIL IS ALLOWED. FBC 107.2.1
  
 2) PROVIDE AN ISOMETRIC DRAWING SHOWING PIPE SIZE AT
 EACH SECTION TO COMPLY WITH FBC 107.3.5 YOU ARE ONLY
 SHOWING THE RAN FROM THE HAND SINK AND THE VENT FROM
 THE FLOOR SINK.
  
 3) YOUR SHOWING 2? AT THE INDIRECT WASTE FLOOR SINK
 WHICH IS UNDERSIZED AS 3? IS REQUIRED AS YOU HAVE 8
 DRAINAGE FIXTURE UNITS (DFU?S) . SEE FBC P TABLE
 710.1(2)
  
 SEE INTERCETOR PLAN REVIEW FOR ADDED NOTES.
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-12-28 Cont ID  
Sent By thunt Date 2017-12-28 Time 07:42 Rev Time 0.00
Received By thunt Date 2017-12-28 Time 07:42 Sent To  
Notes
2017-12-28 07:51:1112/28/2017 1ST PLUMBING REVIEW**DENIED**
  
 1) A SANITARY ISOMETRIC DRAWING IS REQUIRED FBC 107.2.1
  
 2) A WATER ISOMETRIC DRAWING IS REQUIRED FBC 107.2.1
  
 3) CITY RECORD SHOW THIS AS A BUSINESS OCCUPANCY.
 PLEASE EXPLAIN THE PURPOSE FOR ADDING THESE SINKS FBC
 107.2.1. PLEASE BE ADVISED IF THERE IS TO BE ANY FOOD
 COOKED OR SERVED THEN THIS WOUD BE A CHANGE OF
 OCCUPANCY AND A FULL SET OF PLANS WOULD NEED TO BE
 SUBMITTED SHOWING SUCH AND ALL ACCESSIBILTY WOULD NEED
 TO BE BROUGHT UP TO CODE. ZONING WOULD NEED TO APPROVE
 THE CHANGE OF OCCUPANCY FIRST. THIS PLAN REVIEWER HAS
 CALL AND LEFT MESSAGE FOR THIS CONTRACTOR
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop P-GREASE GREASE INTERCEPTOR/TRAP REVIEW
Rev No 2 Status P Date 2018-07-26 Cont ID  
Sent By tklarge Date 2018-07-26 Time 12:44 Rev Time 0.00
Received By tklarge Date 2018-07-26 Time 12:08 Sent To  
Notes
***NONE***

Review Stop P-GREASE GREASE INTERCEPTOR/TRAP REVIEW
Rev No 1 Status F Date 2018-06-01 Cont ID  
Sent By thunt Date 2018-06-01 Time 16:43 Rev Time 0.00
Received By thunt Date 2018-06-01 Time 16:43 Sent To  
Notes
2018-06-01 16:49:5606/01/2018 1ST REVIEW PLUMBING INTERCEPTOR**DENIED**
  
  
 1) YOU MUST SHOW HOW YOU SIZED THE INTERCEPTOR IN
 ACCORDANCE WITH RULE 64E-6 FL. AMEND CODE.
  
 2) THE INTERCEPTOR MODEL YOU HAVE SUPPLIED IS TOO SMALL
 BASE ON MY CALCULATIONS FROM RULE 64E-6 FL. AMEND CODE.
 PROVIDE ANSWER TO COMMENT 1 AND VERIFY BASED ON MODEL
 SPEC'S. FBC 107.2.1
  
 3) A SEPERATE PERMIT APPLICATION FOR GREASE
 INTERCEPTERS IS REQUIRED AND CAN BE PULLED AS A SUB
 PERMIT FROM THIS MASTER. FBC 105.1, FBC P 1003.2
  
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  