Plan Review Details - Permit 17120347
Plan Review Stops For Permit 17120347
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status N Date 2018-05-05 Cont ID  
Sent By shill Date 2018-05-05 Time 08:41 Rev Time 0.00
Received By shill Date 2018-05-05 Time 08:41 Sent To  
Notes
2018-05-05 08:42:12SEE REVIEWS UNDER 18040936

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-03-15 Cont ID  
Sent By shill Date 2018-03-15 Time 09:21 Rev Time 0.00
Received By shill Date 2018-03-14 Time 07:04 Sent To  
Notes
2018-03-15 09:26:27***CORRECTIONS***
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE PREVIOUS REVIEW PASSED WITH PROVISO TO REVISE
 THE PLAN. IT IS NOT CLEAR WHY THIS WAS NOT DONE. AS THE
 PLAN MUST BE RESUBMITTED TO ADDRESS COMMENTS FROM OTHER
 TRADES, PLEASE REVISE PLAN AT THIS TIME.
  
 PLAN IS TO BE REVISED TO SHOW COMPLIANCE WITH FBC
 EXISTING BUILDING CHAPTER 10, CHANGE OF OCCUPANCY.
 STATE EXISTING OCCUPANCY, PROPOSED NEW, AND THEN SHOW
 COMPLIANCE WITH FOLLOWING:
 FBC EXISTING BUILDING TABLE 1012.4
 FBC EXISTING BUILDING TABLE 1012.5
 FBC EXISTING BUILDING TABLE 1012.6
  
 2. SALES COUNTER TO COMPLY WITH FBC ACCESSIBILILTY 904;
 PROVIDE A DETAIL.
  
 3. A LICENSED CONTRACTOR IS REQUIRED TO OVERSEE THIS
 PROJECT. THIS CONTRACTOR TAKES RESPONSIBILITY FOR AND
 SUPERVISES THE SUBCONTRACTORS. AT THIS TIME, THIS
 PERMIT APPLICATION IS A PLUMBING APPLICATION. A
 CONTRACTOR LICENSED TO OVERSEE THE WORK SHOULD BE THE
 PRIME CONTRACTOR. IS IT APPLICANT'S INTENT THAT
 PLUMBING CONTRACTOR IS THE PRIME CONTRACTOR? IF YES,
 HAVE THE PLUMBING CONTRACTOR CONTACT ME. IF NO, SUBMIT
 A PERMIT APPLICATION FROM THE GENERAL OR BUILDING
 CONTRACTOR WHO WILL BE THE CONTRACTOR SUPERVISING THIS
 PROJECT.
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-01-12 Cont ID  
Sent By shill Date 2018-01-12 Time 17:57 Rev Time 0.00
Received By shill Date 2018-01-12 Time 17:57 Sent To  
Notes
2018-01-12 17:58:26****PROVISO****
 ***ISSUED AT APPLICANT'S RISK***
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
  
 PROVISO: SALES COUNTER TO COMPLY WITH FBC
 ACCESSIBILILTY 904
 SUBJECT TO FIELD INSPECTOR'S DISCRETION, A DETAIL MAY
 BE REQUIRED TO BE SUBMITTED FOR PLAN REVIEW
  
 PLAN IS TO BE REVISED TO SHOW COMPLIANCE WITH FBC
 EXISTING BUILDING CHAPTER 10, CHANGE OF OCCUPANCY.
 STATE EXISTING OCCUPANCY, PROPOSED NEW, AND THEN SHOW
 COMPLIANCE WITH FOLLOWING:
 FBC EXISTING BUILDING TABLE 1012.4
 FBC EXISTING BUILDING TABLE 1012.5
 FBC EXISTING BUILDING TABLE 1012.6
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2018-05-05 Cont ID  
Sent By shill Date 2018-05-05 Time 08:42 Rev Time 0.00
Received By shill Date 2018-05-05 Time 08:42 Sent To  
Notes
2018-05-05 08:42:43SEE REVIEWS UNDER 18040936
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-03-07 Cont ID  
Sent By jpearson Date 2018-03-07 Time 06:17 Rev Time 0.00
Received By jpearson Date 2018-03-06 Time 16:02 Sent To  
Notes
2018-03-06 16:02:15CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS NOT ADDRESSED:
  
 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 215.5, 408.4
 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO INTERIOR
 PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM
 BONDING TERMINATION POINT. NEC 215.5, 230, 250.50,
 250.94, 408.30
 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30
 4. PROVIDE DEDICATED CIRCUIT AND CONTROL FOR SIGN. NEC
 600.5; FBC EC 405.2.4
 5. PROVIDE SHOW WINDOW OUTLETS PER CODE. NEC 210.62
 6. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS
 STIPULATED IN THE FBC ENERGY CODE. FBC EC 405.2.2,
 405.2.2.2
  
 NEW COMMENT:
  
 7. PLEASE BE ADVISED THAT THESE COMMENT HAVE NOT BEEN
 ADDRESSED FOR TWO REVIEWS. IF UPON THE THIRD REVIEW, IF
 IT IS NECESSARY TO REJECT THE SUBMITTED PLAN A THIRD
 TIME FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW IS
 REQUIRED. FLORIDA STATUTES STATE: ?WITH RESPECT TO
 EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A
 LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO
 ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND
 ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY
 THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A
 CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN
 EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS,
 FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B)?
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-01-17 Cont ID  
Sent By jpearson Date 2018-01-17 Time 10:46 Rev Time 0.00
Received By jpearson Date 2018-01-17 Time 10:46 Sent To  
Notes
2018-01-17 10:46:38CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 215.5, 408.4
 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO INTERIOR
 PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM
 BONDING TERMINATION POINT. NEC 215.5, 230, 250.50,
 250.94, 408.30
 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30
 4. PROVIDE DEDICATED CIRCUIT AND CONTROL FOR SIGN. NEC
 600.5; FBC EC 405.2.4
 5. PROVIDE SHOW WINDOW OUTLETS PER CODE. NEC 210.62
 6. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS
 STIPULATED IN THE FBC ENERGY CODE. FBC EC 405.2.2,
 405.2.2.2
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-02-28 Cont ID  
Sent By pleduc Date 2018-02-28 Time   Rev Time 0.00
Received By pleduc Date 2018-02-27 Time 17:12 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-01-11 Cont ID  
Sent By pleduc Date 2018-01-11 Time   Rev Time 0.00
Received By pleduc Date 2018-01-10 Time 11:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-03-15 Cont ID  
Sent By shill Date 2018-03-15 Time 09:26 Rev Time 0.00
Received By shill Date 2018-02-21 Time 13:50 Sent To  
Notes
2018-02-22 13:50:58C15

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-02-02 Cont ID  
Sent By cpuell Date 2018-02-02 Time 14:42 Rev Time 0.00
Received By cpuell Date 2018-01-02 Time 11:04 Sent To  
Notes
2018-01-09 10:04:50C11
2018-01-09 06:14:431/9 TO CP / LEM TO PUT ON BOARD (NEEDS B, M, Z;
 POSSIBLE THAT ELEC APPLICATION SHOULD BE INCLUDED IN
 THIS PACKAGE)
  
  
2018-01-03 11:04:35RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-19 Cont ID  
Sent By tklarge Date 2017-12-19 Time 10:34 Rev Time 0.00
Received By tklarge Date 2017-12-08 Time 13:28 Sent To I
Notes
2017-12-11 13:28:22PLUMB <5K

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2018-05-05 Cont ID  
Sent By shill Date 2018-05-05 Time 08:43 Rev Time 0.00
Received By shill Date 2018-05-05 Time 08:43 Sent To  
Notes
2018-05-05 08:43:33SEE REVIEWS UNDER 18040936
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-01-12 Cont ID  
Sent By shill Date 2018-01-12 Time 18:16 Rev Time 0.00
Received By shill Date 2018-01-12 Time 18:08 Sent To  
Notes
2018-01-12 18:12:44****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED.
 AFTER ALL REVIEWS ARE COMPLETE AND PLANS ARE STAMPED,
 CHECK OUT ONE SET OF PLANS AND TAKE TO PALM BEACH
 COUNTY. THE PLANS ARE TO BE STAMPED AND THE RECEIPT
 SHOWING THAT FEES DUE HAVE BEEN PAID IS TO BE PROVIDED.
  
 561-233-5025 FOR MORE INFORMATION
  
 HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION/PAGES/IMP
 ACT-FEES.ASPX
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2018-05-05 Cont ID  
Sent By shill Date 2018-05-05 Time 08:43 Rev Time 0.00
Received By shill Date 2018-05-05 Time 08:43 Sent To  
Notes
2018-05-05 08:43:50SEE REVIEWS UNDER 18040936
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2018-03-05 Cont ID  
Sent By ccole Date 2018-03-05 Time 16:59 Rev Time 0.00
Received By ccole Date 2018-03-05 Time 16:59 Sent To  
Notes
2018-03-05 17:01:102ND REVIEW FBC-2014 MECHANICAL
 PERMIT #17120347
 3/5/18
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE 1ST REVIEW COMMENTS WERE NOT ADDRESSED. I HAVE
 COPIED THEM BELOW- PLEASE COMPLY.
  
  
 1ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17120347
 1/12/18
  
 PLAN REVIEW RESULTS: DENIED.
  
  
 1) NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW. SEE
 REQUIREMENTS BELOW:
  
 A) THE MAIN MECHANICAL REQUIREMENT FOR A HAIR SALON IS
 AN EXHAUST VENTILATION SYSTEM THAT HAS AN EXHAUST RATE
 OF 0.6 CFMS PER SQ. FT FOR THE SALON AREA- TABLE 403.3
  
 B) THE EXHAUST FAN MUST BE SUPPLIED WITH A SOURCE OF
 MAKEUP AIR AND MUST RUN CONTINUOUSLY WHENEVER THE SALON
 IS IN OPERATION- SECTION 501.4
  
 C) THE EXISTING OR NEW AC SYSTEM(S) MUST BE ABLE TO
 PROVIDE OUTDOOR AIR TO OCCUPANTS AT A RATE OF 20 CFMS
 PER PERSON AND 0.12 CFMS PER SQ. FT. THE OCCUPANT LOAD
 PER THE MECHANICAL CODE IS CALCULATED AT 25
 PERSONS/SQ.FT.. PLEASE PROVIDE VENTILATION
 CALCULATIONS.
  
 D) PLEASE NOTE IT IS PROHIBITED FOR AIR THAT IS
 SUPPLIED TO THE SALON SPACE TO BE RECIRCULATED TO OTHER
 ROOMS OR SPACES IN THE TENANT SPACE OR IN THE BUILDING
 IN GENERAL- TABLE 403.3 FOOTNOTE B.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-01-12 Cont ID  
Sent By ccole Date 2018-01-12 Time 09:10 Rev Time 0.00
Received By ccole Date 2018-01-12 Time 09:10 Sent To  
Notes
2018-01-12 09:45:301ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17120347
 1/12/18
  
 PLAN REVIEW RESULTS: DENIED.
  
  
 1) NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW. SEE
 REQUIREMENTS BELOW:
  
 A) THE MAIN MECHANICAL REQUIREMENT FOR A HAIR SALON IS
 AN EXHAUST VENTILATION SYSTEM THAT HAS AN EXHAUST RATE
 OF 0.6 CFMS PER SQ. FT FOR THE SALON AREA- TABLE 403.3
  
 B) THE EXHAUST FAN MUST BE SUPPLIED WITH A SOURCE OF
 MAKEUP AIR AND MUST RUN CONTINUOUSLY WHENEVER THE SALON
 IS IN OPERATION- SECTION 501.4
  
 C) THE EXISTING OR NEW AC SYSTEM(S) MUST BE ABLE TO
 PROVIDE OUTDOOR AIR TO OCCUPANTS AT A RATE OF 20 CFMS
 PER PERSON AND 0.12 CFMS PER SQ. FT. THE OCCUPANT LOAD
 PER THE MECHANICAL CODE IS CALCULATED AT 25
 PERSONS/SQ.FT.. PLEASE PROVIDE VENTILATION
 CALCULATIONS.
  
 D) PLEASE NOTE IT IS PROHIBITED FOR AIR THAT IS
 SUPPLIED TO THE SALON SPACE TO BE RECIRCULATED TO OTHER
 ROOMS OR SPACES IN THE TENANT SPACE OR IN THE BUILDING
 IN GENERAL- TABLE 403.3 FOOTNOTE B.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-03-13 Cont ID  
Sent By gjohnson Date 2018-03-13 Time 16:25 Rev Time 0.00
Received By gjohnson Date 2018-03-13 Time 16:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-01-08 Cont ID  
Sent By tklarge Date 2018-01-08 Time 07:01 Rev Time 0.00
Received By tklarge Date 2018-01-08 Time 06:10 Sent To  
Notes
2018-01-08 06:52:561) THE DESIGN PROFESSIONAL OF RECORD SHALL INDICATE ON
 SHEET #1 OF 3 THAT THIS IS A CHANGE OF OCCUPANCY AND
 NOTE THE PREVIOUS OCCUPANCY OF THE SPACE AND THE NEW
 OCCUPANCY OF THE SPACE. 2014 FBC EXISTING BUILDING CODE
 CHAPT. 501.3, AND SEC. 1001.3.
 2) THE HANDWASH SINK AND THE HAIRWASH SINKS ARE NOT
 PERMITTED ON A HORIZONTAL WET VENT PER 2014
 FBC-PLUMBING SECD. 912.1. AN INDIVIDUAL VENT ON THE MOP
 SINK WILL RECTIFY THIS ISSUE.
 3) THE UNDERGROUND HORIZONTAL SANITARY DRAIN FOR THE
 MOP SINK, HAIR SINKS AND HANDWASHING SINK SHALL BE A
 MINIMUM OF 3 INCHES UP TO THE FIRST HAIR SINK. 2014
 FBC-PLUMBING SEC. 710.1 AND TABLE 710.1 (2).
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-12-19 Cont ID  
Sent By tklarge Date 2017-12-19 Time 10:34 Rev Time 0.00
Received By tklarge Date 2017-12-19 Time 05:05 Sent To I
Notes
2017-12-19 06:13:471) CITY RECORDS SHOW THAT THE PREVIOUS BUSINESS IN THIS
 SPACE WAS A RETAIL STORE (MERCANTILE OCCUPANCY) . A
 HAIR SALON IS CONSIDERED A BUSINESS OCCUPANCY IN
 ACCORDANCE WITH THE 2014 FBC-BUILDING SEC.304.1.
 COMPLIANCE WITH THE 2014 FBC-EXISTING BUILDING SECS.
 1001.3 IS REQUIRED.
 2) 2014 FBC-EXISTING BUILDING VOLUME - SEC.1006.1 -
 ACCESSIBILITY - ACCESSIBILITY IN PORTIONS OF BUILDINGS
 UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL
 COMPLY WITH THE PROVISIONS OF THE FLORIDA BUILDING
 CODE, ACCESSIBILITY. THE EXISTING TOILET ROOM SHALL
 COMPLY WITH THE REQUIREMENTS OF THE ACCESSIBILITY CODE.
 SUBMIT A FLOOR PLAN SHOWING COMPLIANCE.
 3) CORRECT THE ADDRESS ON THE PLANS. THE PLANS NOTE THE
 ADDRESS AS 118 CLEMATIS ST. AND THE ADDRESS ON THE
 PERMIT APPLICATION IS LISTED AS 330 CLEMATIS ST., UNIT
 #118. CLARIFY.
 4) SUBMIT A WATER RISER DIAGRAM THAT CLEARLY SHOWS THE
 ENTIRE SCOPE OF WATER PIPING TO BE INSTALLED. WPB
 AMEND. TO FBC SEC. 107.3.5.1.3 ( 3 ).
 5) SUBMIT A SANITARY RISER DIAGRAM THAT CLEARLY SHOWS
 THE ENTIRE SCOPE OF DRAINAGE PIPING TO BE INSTALLED.
 WPB AMEND. TO FBC SEC. 107.3.5.1.3 ( 4 ).SHOW ALL PIPE
 SIZES ON THE SANITARY RISER. WPB AMEND. TO FBC SEC.
 107.2.1.
 6) ALL INDIRECT WASTE PIPING THAT EXCEEDS 30 INCHES IN
 DEVELOPED LENGTH MEASURED HORIZONTALLY, OR 54 INCHES IN
 TOTAL DEVELOPED LENGTH SHALL BE TRAPPED. 2014
 FBC-PLUMBING SEC. 802.2.
 7) THE SUBMITTED PLANS HAVE A NOTE STATING THAT THE
 EXISTING PLUMBING FIXTURES IN THE TOILET ROOM ARE TO BE
 REMOVED AND TO SEE SHEET TWO OF THREE FOR THE NEW
 LAYOUT. THERE ARE NO SHEETS TWO OF THREE OR THREE OF
 THREE AND THERE IS NO OTHER INFORMATION AS TO THE
 INSTALLATION OF NEW FIXTURES OR WHAT ELSE WILL BE DONE.
 CLARIFY. A MINIMUM OF ONE TOILET ROOM COMPLYING WITH
 THE FLORIDA ACCESSIBILITY CODE SHALL BE PROVIDED.
 8) HOT OR TEMPERED WATER SHALL BE SUPPLIED TO THE NEW
 WASH STATION SINKS AND TO THE HAND SINK PER 2014
 FBC-PLUMBING SEC. 607.1.
 9) TEMPERED WATER SHALL BE SUPPLIED THROUGH A WATER
 TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE 1070
 AND SHALL LIMIT THE TEMPERED WATER TO A MAXIMUM OF 110
 DEGREES. 2014 FBC-PLUMBING SEC.607.1.2.
 10) MEANS SHALL BE PROVIDED FOR CONTROLLING INCREASED
 PRESSURE CAUSED BY THERMAL EXPANSION IN ACCORDANCE WITH
 2014 FBC-PLUMBING SEC.607.3.
 11) SHOW THE OCCUPANT LOAD FOR THE NEW OCCUPANCY ON THE
 PLANS. WPB AMEND. TO FBC SEC. 107.2.1. WPB AMEND. TO
 FBC SEC. 107.3.5.1.1.
 12) BUILDINGS UNDERGOING A CHANGE OF OCCCUPANCY SHALL
 ALSO COMPLY WITH THE 2014 FBC - EXISTING BUILDING CODE
 CHAPTERS 7,8, & 9 PER 2014 FBC EXISTING BUILDING
 SEC.1012.1.1.
  
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2018-02-02 Cont ID  
Sent By ajones Date 2018-02-02 Time 13:19 Rev Time 0.00
Received By ajones Date 2018-02-02 Time 13:19 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy