Plan Review Stops For Permit 17120347 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
N |
Date |
2018-05-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-05 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-05 |
Time |
08:41 |
Sent To |
|
|
Notes |
2018-05-05 08:42:12 | SEE REVIEWS UNDER 18040936 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-03-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-03-15 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-03-14 |
Time |
07:04 |
Sent To |
|
|
Notes |
2018-03-15 09:26:27 | ***CORRECTIONS*** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. THE PREVIOUS REVIEW PASSED WITH PROVISO TO REVISE | | THE PLAN. IT IS NOT CLEAR WHY THIS WAS NOT DONE. AS THE | | PLAN MUST BE RESUBMITTED TO ADDRESS COMMENTS FROM OTHER | | TRADES, PLEASE REVISE PLAN AT THIS TIME. | | | | PLAN IS TO BE REVISED TO SHOW COMPLIANCE WITH FBC | | EXISTING BUILDING CHAPTER 10, CHANGE OF OCCUPANCY. | | STATE EXISTING OCCUPANCY, PROPOSED NEW, AND THEN SHOW | | COMPLIANCE WITH FOLLOWING: | | FBC EXISTING BUILDING TABLE 1012.4 | | FBC EXISTING BUILDING TABLE 1012.5 | | FBC EXISTING BUILDING TABLE 1012.6 | | | | 2. SALES COUNTER TO COMPLY WITH FBC ACCESSIBILILTY 904; | | PROVIDE A DETAIL. | | | | 3. A LICENSED CONTRACTOR IS REQUIRED TO OVERSEE THIS | | PROJECT. THIS CONTRACTOR TAKES RESPONSIBILITY FOR AND | | SUPERVISES THE SUBCONTRACTORS. AT THIS TIME, THIS | | PERMIT APPLICATION IS A PLUMBING APPLICATION. A | | CONTRACTOR LICENSED TO OVERSEE THE WORK SHOULD BE THE | | PRIME CONTRACTOR. IS IT APPLICANT'S INTENT THAT | | PLUMBING CONTRACTOR IS THE PRIME CONTRACTOR? IF YES, | | HAVE THE PLUMBING CONTRACTOR CONTACT ME. IF NO, SUBMIT | | A PERMIT APPLICATION FROM THE GENERAL OR BUILDING | | CONTRACTOR WHO WILL BE THE CONTRACTOR SUPERVISING THIS | | PROJECT. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-01-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-01-12 |
Time |
17:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-01-12 |
Time |
17:57 |
Sent To |
|
|
Notes |
2018-01-12 17:58:26 | ****PROVISO**** | | ***ISSUED AT APPLICANT'S RISK*** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | | | PROVISO: SALES COUNTER TO COMPLY WITH FBC | | ACCESSIBILILTY 904 | | SUBJECT TO FIELD INSPECTOR'S DISCRETION, A DETAIL MAY | | BE REQUIRED TO BE SUBMITTED FOR PLAN REVIEW | | | | PLAN IS TO BE REVISED TO SHOW COMPLIANCE WITH FBC | | EXISTING BUILDING CHAPTER 10, CHANGE OF OCCUPANCY. | | STATE EXISTING OCCUPANCY, PROPOSED NEW, AND THEN SHOW | | COMPLIANCE WITH FOLLOWING: | | FBC EXISTING BUILDING TABLE 1012.4 | | FBC EXISTING BUILDING TABLE 1012.5 | | FBC EXISTING BUILDING TABLE 1012.6 | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
N |
Date |
2018-05-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-05 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-05 |
Time |
08:42 |
Sent To |
|
|
Notes |
2018-05-05 08:42:43 | SEE REVIEWS UNDER 18040936 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-03-07 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-03-07 |
Time |
06:17 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-03-06 |
Time |
16:02 |
Sent To |
|
|
Notes |
2018-03-06 16:02:15 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS NOT ADDRESSED: | | | | 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO INTERIOR | | PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM | | BONDING TERMINATION POINT. NEC 215.5, 230, 250.50, | | 250.94, 408.30 | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30 | | 4. PROVIDE DEDICATED CIRCUIT AND CONTROL FOR SIGN. NEC | | 600.5; FBC EC 405.2.4 | | 5. PROVIDE SHOW WINDOW OUTLETS PER CODE. NEC 210.62 | | 6. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | STIPULATED IN THE FBC ENERGY CODE. FBC EC 405.2.2, | | 405.2.2.2 | | | | NEW COMMENT: | | | | 7. PLEASE BE ADVISED THAT THESE COMMENT HAVE NOT BEEN | | ADDRESSED FOR TWO REVIEWS. IF UPON THE THIRD REVIEW, IF | | IT IS NECESSARY TO REJECT THE SUBMITTED PLAN A THIRD | | TIME FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW IS | | REQUIRED. FLORIDA STATUTES STATE: ?WITH RESPECT TO | | EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B)? | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-01-17 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-01-17 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-01-17 |
Time |
10:46 |
Sent To |
|
|
Notes |
2018-01-17 10:46:38 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO INTERIOR | | PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM | | BONDING TERMINATION POINT. NEC 215.5, 230, 250.50, | | 250.94, 408.30 | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30 | | 4. PROVIDE DEDICATED CIRCUIT AND CONTROL FOR SIGN. NEC | | 600.5; FBC EC 405.2.4 | | 5. PROVIDE SHOW WINDOW OUTLETS PER CODE. NEC 210.62 | | 6. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | STIPULATED IN THE FBC ENERGY CODE. FBC EC 405.2.2, | | 405.2.2.2 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-02-28 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-02-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-02-27 |
Time |
17:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2018-01-11 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-01-11 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-01-10 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-03-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-03-15 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-02-21 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-02-02 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2018-02-02 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-01-02 |
Time |
11:04 |
Sent To |
|
|
Notes |
2018-01-09 10:04:50 | C11 | 2018-01-09 06:14:43 | 1/9 TO CP / LEM TO PUT ON BOARD (NEEDS B, M, Z; | | POSSIBLE THAT ELEC APPLICATION SHOULD BE INCLUDED IN | | THIS PACKAGE) | | | | | 2018-01-03 11:04:35 | RESUB ROUTED TO TKLARGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-12-19 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-12-19 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-12-08 |
Time |
13:28 |
Sent To |
I |
|
Notes |
2017-12-11 13:28:22 | PLUMB <5K |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
N |
Date |
2018-05-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-05 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-05 |
Time |
08:43 |
Sent To |
|
|
Notes |
2018-05-05 08:43:33 | SEE REVIEWS UNDER 18040936 | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-01-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-01-12 |
Time |
18:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-01-12 |
Time |
18:08 |
Sent To |
|
|
Notes |
2018-01-12 18:12:44 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | AFTER ALL REVIEWS ARE COMPLETE AND PLANS ARE STAMPED, | | CHECK OUT ONE SET OF PLANS AND TAKE TO PALM BEACH | | COUNTY. THE PLANS ARE TO BE STAMPED AND THE RECEIPT | | SHOWING THAT FEES DUE HAVE BEEN PAID IS TO BE PROVIDED. | | | | 561-233-5025 FOR MORE INFORMATION | | | | HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION/PAGES/IMP | | ACT-FEES.ASPX | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
N |
Date |
2018-05-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-05-05 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-05-05 |
Time |
08:43 |
Sent To |
|
|
Notes |
2018-05-05 08:43:50 | SEE REVIEWS UNDER 18040936 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2018-03-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-03-05 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-03-05 |
Time |
16:59 |
Sent To |
|
|
Notes |
2018-03-05 17:01:10 | 2ND REVIEW FBC-2014 MECHANICAL | | PERMIT #17120347 | | 3/5/18 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE 1ST REVIEW COMMENTS WERE NOT ADDRESSED. I HAVE | | COPIED THEM BELOW- PLEASE COMPLY. | | | | | | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17120347 | | 1/12/18 | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW. SEE | | REQUIREMENTS BELOW: | | | | A) THE MAIN MECHANICAL REQUIREMENT FOR A HAIR SALON IS | | AN EXHAUST VENTILATION SYSTEM THAT HAS AN EXHAUST RATE | | OF 0.6 CFMS PER SQ. FT FOR THE SALON AREA- TABLE 403.3 | | | | B) THE EXHAUST FAN MUST BE SUPPLIED WITH A SOURCE OF | | MAKEUP AIR AND MUST RUN CONTINUOUSLY WHENEVER THE SALON | | IS IN OPERATION- SECTION 501.4 | | | | C) THE EXISTING OR NEW AC SYSTEM(S) MUST BE ABLE TO | | PROVIDE OUTDOOR AIR TO OCCUPANTS AT A RATE OF 20 CFMS | | PER PERSON AND 0.12 CFMS PER SQ. FT. THE OCCUPANT LOAD | | PER THE MECHANICAL CODE IS CALCULATED AT 25 | | PERSONS/SQ.FT.. PLEASE PROVIDE VENTILATION | | CALCULATIONS. | | | | D) PLEASE NOTE IT IS PROHIBITED FOR AIR THAT IS | | SUPPLIED TO THE SALON SPACE TO BE RECIRCULATED TO OTHER | | ROOMS OR SPACES IN THE TENANT SPACE OR IN THE BUILDING | | IN GENERAL- TABLE 403.3 FOOTNOTE B. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-01-12 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-01-12 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-01-12 |
Time |
09:10 |
Sent To |
|
|
Notes |
2018-01-12 09:45:30 | 1ST REVIEW FBC-2014 MECHANICAL | | PERMIT #17120347 | | 1/12/18 | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW. SEE | | REQUIREMENTS BELOW: | | | | A) THE MAIN MECHANICAL REQUIREMENT FOR A HAIR SALON IS | | AN EXHAUST VENTILATION SYSTEM THAT HAS AN EXHAUST RATE | | OF 0.6 CFMS PER SQ. FT FOR THE SALON AREA- TABLE 403.3 | | | | B) THE EXHAUST FAN MUST BE SUPPLIED WITH A SOURCE OF | | MAKEUP AIR AND MUST RUN CONTINUOUSLY WHENEVER THE SALON | | IS IN OPERATION- SECTION 501.4 | | | | C) THE EXISTING OR NEW AC SYSTEM(S) MUST BE ABLE TO | | PROVIDE OUTDOOR AIR TO OCCUPANTS AT A RATE OF 20 CFMS | | PER PERSON AND 0.12 CFMS PER SQ. FT. THE OCCUPANT LOAD | | PER THE MECHANICAL CODE IS CALCULATED AT 25 | | PERSONS/SQ.FT.. PLEASE PROVIDE VENTILATION | | CALCULATIONS. | | | | D) PLEASE NOTE IT IS PROHIBITED FOR AIR THAT IS | | SUPPLIED TO THE SALON SPACE TO BE RECIRCULATED TO OTHER | | ROOMS OR SPACES IN THE TENANT SPACE OR IN THE BUILDING | | IN GENERAL- TABLE 403.3 FOOTNOTE B. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-03-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-03-13 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-03-13 |
Time |
16:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-01-08 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-01-08 |
Time |
07:01 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-01-08 |
Time |
06:10 |
Sent To |
|
|
Notes |
2018-01-08 06:52:56 | 1) THE DESIGN PROFESSIONAL OF RECORD SHALL INDICATE ON | | SHEET #1 OF 3 THAT THIS IS A CHANGE OF OCCUPANCY AND | | NOTE THE PREVIOUS OCCUPANCY OF THE SPACE AND THE NEW | | OCCUPANCY OF THE SPACE. 2014 FBC EXISTING BUILDING CODE | | CHAPT. 501.3, AND SEC. 1001.3. | | 2) THE HANDWASH SINK AND THE HAIRWASH SINKS ARE NOT | | PERMITTED ON A HORIZONTAL WET VENT PER 2014 | | FBC-PLUMBING SECD. 912.1. AN INDIVIDUAL VENT ON THE MOP | | SINK WILL RECTIFY THIS ISSUE. | | 3) THE UNDERGROUND HORIZONTAL SANITARY DRAIN FOR THE | | MOP SINK, HAIR SINKS AND HANDWASHING SINK SHALL BE A | | MINIMUM OF 3 INCHES UP TO THE FIRST HAIR SINK. 2014 | | FBC-PLUMBING SEC. 710.1 AND TABLE 710.1 (2). | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-12-19 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-12-19 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-12-19 |
Time |
05:05 |
Sent To |
I |
|
Notes |
2017-12-19 06:13:47 | 1) CITY RECORDS SHOW THAT THE PREVIOUS BUSINESS IN THIS | | SPACE WAS A RETAIL STORE (MERCANTILE OCCUPANCY) . A | | HAIR SALON IS CONSIDERED A BUSINESS OCCUPANCY IN | | ACCORDANCE WITH THE 2014 FBC-BUILDING SEC.304.1. | | COMPLIANCE WITH THE 2014 FBC-EXISTING BUILDING SECS. | | 1001.3 IS REQUIRED. | | 2) 2014 FBC-EXISTING BUILDING VOLUME - SEC.1006.1 - | | ACCESSIBILITY - ACCESSIBILITY IN PORTIONS OF BUILDINGS | | UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL | | COMPLY WITH THE PROVISIONS OF THE FLORIDA BUILDING | | CODE, ACCESSIBILITY. THE EXISTING TOILET ROOM SHALL | | COMPLY WITH THE REQUIREMENTS OF THE ACCESSIBILITY CODE. | | SUBMIT A FLOOR PLAN SHOWING COMPLIANCE. | | 3) CORRECT THE ADDRESS ON THE PLANS. THE PLANS NOTE THE | | ADDRESS AS 118 CLEMATIS ST. AND THE ADDRESS ON THE | | PERMIT APPLICATION IS LISTED AS 330 CLEMATIS ST., UNIT | | #118. CLARIFY. | | 4) SUBMIT A WATER RISER DIAGRAM THAT CLEARLY SHOWS THE | | ENTIRE SCOPE OF WATER PIPING TO BE INSTALLED. WPB | | AMEND. TO FBC SEC. 107.3.5.1.3 ( 3 ). | | 5) SUBMIT A SANITARY RISER DIAGRAM THAT CLEARLY SHOWS | | THE ENTIRE SCOPE OF DRAINAGE PIPING TO BE INSTALLED. | | WPB AMEND. TO FBC SEC. 107.3.5.1.3 ( 4 ).SHOW ALL PIPE | | SIZES ON THE SANITARY RISER. WPB AMEND. TO FBC SEC. | | 107.2.1. | | 6) ALL INDIRECT WASTE PIPING THAT EXCEEDS 30 INCHES IN | | DEVELOPED LENGTH MEASURED HORIZONTALLY, OR 54 INCHES IN | | TOTAL DEVELOPED LENGTH SHALL BE TRAPPED. 2014 | | FBC-PLUMBING SEC. 802.2. | | 7) THE SUBMITTED PLANS HAVE A NOTE STATING THAT THE | | EXISTING PLUMBING FIXTURES IN THE TOILET ROOM ARE TO BE | | REMOVED AND TO SEE SHEET TWO OF THREE FOR THE NEW | | LAYOUT. THERE ARE NO SHEETS TWO OF THREE OR THREE OF | | THREE AND THERE IS NO OTHER INFORMATION AS TO THE | | INSTALLATION OF NEW FIXTURES OR WHAT ELSE WILL BE DONE. | | CLARIFY. A MINIMUM OF ONE TOILET ROOM COMPLYING WITH | | THE FLORIDA ACCESSIBILITY CODE SHALL BE PROVIDED. | | 8) HOT OR TEMPERED WATER SHALL BE SUPPLIED TO THE NEW | | WASH STATION SINKS AND TO THE HAND SINK PER 2014 | | FBC-PLUMBING SEC. 607.1. | | 9) TEMPERED WATER SHALL BE SUPPLIED THROUGH A WATER | | TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE 1070 | | AND SHALL LIMIT THE TEMPERED WATER TO A MAXIMUM OF 110 | | DEGREES. 2014 FBC-PLUMBING SEC.607.1.2. | | 10) MEANS SHALL BE PROVIDED FOR CONTROLLING INCREASED | | PRESSURE CAUSED BY THERMAL EXPANSION IN ACCORDANCE WITH | | 2014 FBC-PLUMBING SEC.607.3. | | 11) SHOW THE OCCUPANT LOAD FOR THE NEW OCCUPANCY ON THE | | PLANS. WPB AMEND. TO FBC SEC. 107.2.1. WPB AMEND. TO | | FBC SEC. 107.3.5.1.1. | | 12) BUILDINGS UNDERGOING A CHANGE OF OCCCUPANCY SHALL | | ALSO COMPLY WITH THE 2014 FBC - EXISTING BUILDING CODE | | CHAPTERS 7,8, & 9 PER 2014 FBC EXISTING BUILDING | | SEC.1012.1.1. | | | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2018-02-02 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2018-02-02 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2018-02-02 |
Time |
13:19 |
Sent To |
|
|
Notes |
|
|