Plan Review Details - Permit 17120310
Plan Review Stops For Permit 17120310
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-04-19 Cont ID  
Sent By jgomez Date 2021-04-19 Time 16:13 Rev Time 0.00
Received By jgomez Date 2021-04-19 Time 15:07 Sent To  
Notes
2021-04-19 16:14:25BUILDING REVIEW APPROVED WITH PROVISO:
 NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS. :
 1-DEFERRED SUBMITTALS:
 WINDOWS, DOORS, ROOFING AND ROOF VENTS, ALUMINUM
 SOFFITS,
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE FOR REVIEW PRIOR TO SUBMITTAL TO
 THIS OFFICE. SEC. 107.3.4.1 CITY AMENDMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-03-08 Cont ID  
Sent By jgomez Date 2021-03-08 Time 10:02 Rev Time 0.00
Received By jgomez Date 2021-03-08 Time 09:11 Sent To  
Notes
2021-03-08 09:43:32NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 1- ENERGY CALCULATIONS:
 THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED AND
 DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY
 DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION,
 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO
 BEGIN CONSTRUCTION.
  
 RESPONSE:
 SIGNED ENERGY CALCULATIONS SUBMITTED ARE FOR ANOTHER
 HOUSE. ENERGY CALCULATIONS SUBMITTED ARE FOR 425 HOGANS
 ST. THIS PERMIT APPLICATION IS FOR 422 20TH ST. PROVIDE
 CORRECT ENERGY CALCULATIONS.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION,
  
 2- OK.
  
 3- OK.
  
 ORIGINAL COMMENT:
 4- PROVIDE BOUNDARY LINE SURVEY AS REQUIRED BY SEC.
 107.2.5 CITY AMENDMENTS.
 PROVIDE SURVEY WITH ORIGINAL SEAL/SIGNATURE (DIGITAL
 SIGNATURE OR HARDCOPY ORIGINAL) AS REQUIRED BY CHAPTER
 472 FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS FOR
 PUBLIC RECORDS.
  
 RESPONSE:
 SURVEY UPLOADED IS FOR LOT 4. THIS PERMIT APPLICATION
 IS FOR LOT 2. PROVIDE CORRECT SURVEY. NOTE: PLEASE
 UPLOAD THE SURVEY IN THE "DRAWINGS" FOLDER NOT IN THE
 "SUPPORTING DOCUMENTS" FOLDER AS REQUIRED BY THE CITY
 GUIDELINES FOR DIGITAL SUBMITTALS.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 5- MERRY PLACE LOT GRADING SHEET C1:
 A) DRAWING C1 WAS UPLOADED IN THE "SUPPORTING
 DOCUMENTS" FOLDER INSTEAD OF THE "DRAWINGS" FOLDER. ALL
 DRAWINGS NEED TO BE UPLOADED IN THE "DRAWINGS" FOLDER
 (WITH PROPER DIGITAL SIGNATURE) AS REQUIRED BY THE CITY
 DIGITAL PLAN REVIEW INSTRUCTIONS AND SEC. 107.2.1.3
 CITY AMENDMENTS FOR PROPER RECORDS RETENTION.
  
 RESPONSE:
 NOW WE ARE MISSING DRAWING C1. PLEASE UPLOAD DRAWING C1
 INTO THE DRAWINGS FOLDER.
  
 6-DEFERRED SUBMITTALS:
 WINDOWS, DOORS, ROOFING AND ROOF VENTS, ALUMINUM
 SOFFITS, RAILINGS AND GUARDRAILS.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE FOR REVIEW PRIOR TO SUBMITTAL TO
 THIS OFFICE. SEC. 107.3.4.1 CITY AMENDMENTS.
  
  
 7- NEW COMMENT FOR CLARIFICATION:
 THERE ARE TWO SITE PLANS SUBMITTED. ONE OF THEM IS
 SHEET A-0.1 AND THE OTHER ONE IS SHEET SP-1. CLARIFY
 WHY SUBMITTING 2 DIFFERENT DRAWINGS FOR THE SITE PLAN
 AND WHICH ONE IS THE CORRECT ONE. PLEASE PROVIDE ONLY
 THE ONE TO BE CONSIDERED TO AVOID CONFLICTS/DELAYS.
 SEC. 107.2.1 CITY AMENDMENTS.
  
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-10-30 Cont ID  
Sent By jgomez Date 2020-10-30 Time 18:06 Rev Time 0.00
Received By jgomez Date 2020-10-30 Time 16:53 Sent To  
Notes
2020-10-30 18:07:07NEW SINGLE FAMILY RESIDENCE R3) BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- ENERGY CALCULATIONS:
 THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED AND
 DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY
 DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION,
 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO
 BEGIN CONSTRUCTION.
  
 2- STRUCTURAL DRAWINGS S1, S2, S3 AND S4 WERE NOT
 UPLOADED FOR REVIEW. NEED TO UPLOAD THESE DRAWINGS.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 3- 03/08/21 COMMENT WAS OMITTED. THIS IS ONE STORY
 HOUSE. JG.
  
 4- PROVIDE BOUNDARY LINE SURVEY AS REQUIRED BY SEC.
 107.2.5 CITY AMENDMENTS.
 PROVIDE SURVEY WITH ORIGINAL SEAL/SIGNATURE (DIGITAL
 SIGNATURE OR HARDCOPY ORIGINAL) AS REQUIRED BY CHAPTER
 472 FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS FOR
 PUBLIC RECORDS.
  
 5- MERRY PLACE LOT GRADING SHEET C1:
 A) DRAWING C1 WAS UPLOADED IN THE "SUPPORTING
 DOCUMENTS" FOLDER INSTEAD OF THE "DRAWINGS" FOLDER. ALL
 DRAWINGS NEED TO BE UPLOADED IN THE "DRAWINGS" FOLDER
 (WITH PROPER DIGITAL SIGNATURE) AS REQUIRED BY THE CITY
 DIGITAL PLAN REVIEW INSTRUCTIONS AND SEC. 107.2.1.3
 CITY AMENDMENTS FOR PROPER RECORDS RETENTION.
  
 B) DRAWING C1 SHOWS DETAIL SECTIONS A/C2 AND B/C2.
 WHERE ARE THESE DETAILS?. SHEET C2 WAS NOT UPLOADED.
 PROVIDE THESE DETAILS AND REVISE DETAIL REFERENCE
 ACCORDINGLY. SEC. 107.2.1 CITY AMENDMENTS.
  
 6-DEFERRED SUBMITTALS:
 WINDOWS, DOORS, ROOFING AND ROOF VENTS, ALUMINUM
 SOFFITS, RAILINGS AND GUARDRAILS.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE FOR REVIEW PRIOR TO SUBMITTAL TO
 THIS OFFICE. SEC. 107.3.4.1 CITY AMENDMENTS.
  
 7- VALUATION DECLARED IN THE PERMIT APPLICATION IS LOW.
 VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S
 OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS
 REQUIRED BY SEC. 109.3 CITY AMENDMENTS. VALUATION WAS
 UPDATED TO $199,160. THE PERMIT FEE BALANCE IS $3801.84
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-03-09 Cont ID  
Sent By jleahy Date 2021-03-09 Time 07:09 Rev Time 0.00
Received By jleahy Date 2021-03-09 Time 06:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-10-28 Cont ID  
Sent By jleahy Date 2020-10-28 Time 07:32 Rev Time 0.00
Received By jleahy Date 2020-10-28 Time 07:26 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2020-10-28 Cont ID  
Sent By jleahy Date 2020-10-28 Time 07:31 Rev Time 0.00
Received By jleahy Date 2020-10-28 Time 07:26 Sent To  
Notes
2020-10-28 07:32:05LOW VOLTAGE FOR TVS ONLY JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-04-22 Cont ID  
Sent By lmarchan Date 2021-04-22 Time 11:53 Rev Time 0.00
Received By lmarchan Date 2021-04-15 Time 13:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-04-09 Cont ID  
Sent By pvalenti Date 2021-04-09 Time 09:04 Rev Time 0.00
Received By pvalenti Date 2021-02-26 Time 08:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-04 Cont ID  
Sent By ajones Date 2020-11-04 Time 09:27 Rev Time 0.00
Received By ajones Date 2020-10-26 Time 12:57 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2021-04-25 Cont ID  
Sent By lmarchan Date 2021-04-25 Time 08:14 Rev Time 0.00
Received By lmarchan Date 2021-04-25 Time 08:14 Sent To  
Notes
2021-04-25 08:14:24RECEIPT MU-2021-19509 - $0.00 DUE

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-11-02 Cont ID  
Sent By jgomez Date 2020-11-02 Time 13:07 Rev Time 0.00
Received By jgomez Date 2020-11-02 Time 13:06 Sent To  
Notes
2020-11-02 13:07:22IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-10-29 Cont ID  
Sent By medwards Date 2020-10-29 Time 15:45 Rev Time 0.00
Received By medwards Date 2020-10-29 Time 15:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-03-09 Cont ID  
Sent By lcrespo Date 2021-03-09 Time 10:54 Rev Time 0.00
Received By lcrespo Date 2021-03-09 Time 10:25 Sent To  
Notes
2021-03-09 10:56:1903/09/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-10-27 Cont ID  
Sent By lcrespo Date 2020-10-27 Time 09:12 Rev Time 0.00
Received By lcrespo Date 2020-10-27 Time 09:12 Sent To  
Notes
2020-10-27 09:12:5110/27/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLEASE HAVE YOUR PLANS THAT ARE SIGNED AND SEALED BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR -
 IF YOUR ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF (CITY HALL DROPBOX) THE
 ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH A "PLAN
 REVIEW REQUEST FORM" EXPLAINING THE REASON FOR
 SUBMITTING THE DOCUMENT OR DRAWINGS. THE PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY EMAILING [email protected] AND
 ASKING FOR THE FORM.
  
 2. ON THE P-1 SHEET, THE WASHING MACHINE IS ON A 2"
 DRAIN AND THERE IS NO CODE REFERENCE FOR THE SIZE IN
 THE RESIDENTIAL CODE BUT IN THE 2017 FBC RESIDENTIAL
 2601.1, IT SAYS THAT ANY NOT ADDRESSED BY THIS CODE
 SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF THE
 FLORIDA BUILDING CODE, PLUMBING. IN THE 2017 FLORIDA
 BUILDING CODE ? PLUMBING TABLE TABLE 709.1 DRAINAGE
 FIXTURE UNITS FOR FIXTURES AND GROUPS FOR AUTOMATIC
 CLOTHE WASHERS THE RESIDENTIAL HAS A FOOT NOT (G) THAT
 SENDS YOU TO 406.2 FOR SIZING REQUIREMENTS FOR FIXTURE
 DRAIN, BRANCH DRAIN, AND DRAINAGE STACK FOR AN
 AUTOMATIC CLOTHES WASHER STANDPIPE. THE FIXTURE DRAIN
 FOR THE STANDPIPE SERVING AN AUTOMATIC CLOTHES WASHER
 SHALL CONNECT TO A 3-INCH PER THE 2017 FBC SEC. 406.2
 WASTE CONNECTION.
  
 3. IT IS ALSO RECOMMENDED THAT THE TOILET ON THE BRANCH
 FOR THE WASHING MACHINE BE MOVED TO THE BATHROOM GROUP
 BUT NOT ENFORCED. THIS IS TO PREVENT SUDS FROM CHOKING
 THE TRAP OF THE TOILET WHICH WILL MAKE IT REGURGITATE
 FOR AIR. THE VENT SHOWN WILL NOT WORK AS IT WILL NOT
 HAVE A WALL.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2020-11-02 Cont ID  
Sent By jgomez Date 2020-11-02 Time 13:09 Rev Time 0.00
Received By jgomez Date 2020-11-02 Time 13:09 Sent To  
Notes
2020-11-02 13:10:15ROOFING PRODUCT APPROVALS AND ROOFING VENTS SHOWN ON
 PLANS WILL BE SUBMITTED LATER AS DEFERRED SUBMITTALS.
 JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-04-19 Cont ID  
Sent By jgomez Date 2021-04-19 Time 16:23 Rev Time 0.00
Received By jgomez Date 2021-04-19 Time 16:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-03-08 Cont ID  
Sent By jgomez Date 2021-03-08 Time 10:49 Rev Time 0.00
Received By jgomez Date 2021-03-08 Time 10:49 Sent To  
Notes
2021-03-08 10:34:18SITE PLAN DRAWING SP-1 UPLOADED ON 01/20/21 DOESN'T
 HAVE A DIGITAL SIGNATURE. PLEASE PROVIDE DIGITAL
 SIGNATURE AS DONE WITH THE OTHER DRAWINGS.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-11-02 Cont ID  
Sent By jgomez Date 2020-11-02 Time 13:07 Rev Time 0.00
Received By jgomez Date 2020-11-02 Time 13:07 Sent To  
Notes
2020-11-02 13:09:38SIGNATURE:
 DRAWINGS SUBMITTED:
 DRAWINGS HAVE COPY OF THE DESIGN PROFESSIONAL
 SEAL/SIGNATURE. PLEASE RESUBMIT ALL DRAWINGS WITH
 DESIGN PROFESSIONAL ORIGINAL SEAL/SIGNATURE. SINCE THIS
 IS AN ELECTRONIC SUBMITTAL, IT IS BETTER TO RESUBMIT
 WITH THE DESIGN PROFESSIONAL DIGITAL SIGNATURE.
 OTHERWISE, HARDCOPIES OF PLANS WITH DESIGN PROFESSIONAL
 ORIGINAL SEAL/SIGNATURE MAY BE DROPPED OFF IN CITY
 HALL.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2021-04-22 Cont ID  
Sent By ajones Date 2021-04-22 Time 11:01 Rev Time 0.00
Received By ajones Date 2021-04-22 Time 11:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2021-04-08 Cont ID  
Sent By ajones Date 2021-04-08 Time 10:12 Rev Time 0.00
Received By ajones Date 2021-04-08 Time 10:12 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-11-04 Cont ID  
Sent By avann Date 2020-11-04 Time 09:27 Rev Time 0.00
Received By ajones Date 2020-11-04 Time 09:27 Sent To  
Notes
2020-11-04 09:27:3111/4/20-FAILED. THE CORNER SETBACK REQIUREMENT FOR
 MERRYPLACE SMALL COTTAGE HOMES IS 6.5 FEET.
  
 ANGELLA VANN, AICP
 561-822-1441
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved