2018-01-02 13:50:18 | NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW |
| COMMENTS. |
| CODE: FBC 5TH EDITION (2014). |
| |
| 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| COUNTY (2300 N. JOG RD.) FOR IMPACT FEE ASSESSMENT. |
| BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID |
| RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF |
| THE UNIFIED LAND DEVELOPMENT CODE. |
| |
| 2- DRAWINGS NEED TO HAVE THE CORRECT ADDRESS. THE HOUSE |
| IS LOCATED ON WINDSOR AVE NOT WINDSOR CT. ALSO, THE |
| CORRECT ZIP CODE IS 33407 NOT 33401. THE ASSIGNED |
| ADDRESS FOR THIS NEW HOUSE IS 3719 WINDSOR AVE, WEST |
| PALM BEACH FL 33407. REVISE INFORMATION ON ALL PLANS AS |
| REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. |
| |
| 3- FLOOR PLAN ON SHEET 1. |
| A) SPECIFY THE SIZE OF THE ENTRY DOOR TO VERIFY |
| COMPLIANCE WITH SEC. R311.2 FBC-RESIDENTIAL, 5TH |
| EDITION (2014). |
| |
| B) SPECIFY SELF CLOSING DEVICE FOR DOOR LEADING FROM |
| THE GARAGE TO THE MAIN HOUSE AS REQUIRED BY SEC. |
| R302.5.1 FBC RESIDENTIAL. |
| |
| 4- REVISE THE GRAVITY LOADS SPECIFIED ON SHEET T-1. |
| NEED TO REVISE THE ATTIC LIVE LOAD TO COMPLY WITH TABLE |
| R301.5 FBC-RESIDENTIAL. |
| |
| 5- REVISE STRUCTURAL NOTE #3 ON SHEET T-1. ACCORDING TO |
| ASTM C 1063 THE HIGH RIB METAL LATH NEED TO BE NAILED |
| WITH NAILS OR STAPLES THAT PROVIDE MIN. 1-3/4" |
| PENETRATION INTO THE ROOF TRUSS. THEREFORE THE 1-1/2" |
| NAILS DON'T COMPLY. REVISE AS REQUIRED. |
| |
| 6- JOBSITE LOCATION MAP SHOWN ON SHEET D-1 DOESN'T |
| CORRESPOND TO PROPOSED LOCATION. REVISE AS REQUIRED. |
| SEC. 107.2.1 CITY AMENDMENTS. |
| |
| 7- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, |
| CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN |
| PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY |
| AMENDMENTS. VALUATION WAS UPDATED TO $215,855. THE |
| PERMIT FEE BALANCE IS $4137.66. |
| |
| 8- ENERGY CALCULATIONS SUBMITTED: |
| A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM |
| INCLUDING THE HOUSE ADDRESS (3719 WINDSOR AVE WPB. FL |
| 33407), OWNER'S NAME AND BUILDER'S NAME. SEC. |
| R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION |
| (2014). |
| |
| B) CONCRETE BLOCK WALL INSULATION SPECIFIED ON ITEM #9 |
| DOESN'T MATCH PLANS. REVISE AS REQUIRED TO MATCH. SEC. |
| R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| C) CEILING INSULATION SPECIFIED ON ITEM #10 DOESN'T |
| MATCH PLANS. REVISE AS REQUIRED TO MATCH. SEC. |
| R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| D) PROVIDE THE NAME OF THE PERSON RESPONSIBLE FOR THE |
| DESIGN AS REQUIRED BY SEC. R405.4.2 FBC-ENERGY |
| CONSERVATION. |
| |
| E) DOORS INFORMATION ON PAGE 3 OF 4 SPECIFIES AN |
| INSULATED DOOR ON THE SOUTH. PLANS DON'T SHOW ANY |
| INSULATED DOOR ON THE SOUTH SIDE. CLARIFY WHERE IS THIS |
| DOOR LOCATED AT. REVISE AS REQUIRED TO MATCH PLANS. |
| SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| F) WINDOWS INFORMATION SHOWN ON PAGE 3 OF 4 DOESN'T |
| MATCH PLANS. REVISE THE ORIENTATION, AREA AND OVERHANG |
| DEPTH AND SEPARATION TO MATCH PLANS. SEC. R101.5.1.1.2 |
| FBC-ENERGY CONSERVATION. |
| |
| G) GARAGE FLOOR AREA AND CEILING AREA SHOWN ON PAGE 3 |
| OF 4 DOESN'T MATCH PLANS. REVISE AS REQUIRED TO MATCH. |
| SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| H) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL |
| (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-ENERGY |
| CONSERVATION. |
| |
| NOTE: |
| LABEL REQUIRED FOR DOORS AND WINDOWS SHOWING THE |
| U-FACTOR AND SHGC FACTOR SPECIFIED IN THE ENERGY |
| CALCULATIONS IS REQUIRED WHEN THE CALCULATIONS DON'T |
| USE THE PROGRAM'S DEFAULT FACTOR. |
| |
| 9- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| FAC 61G20-3.001 FOR: |
| A) ENTRY DOOR WITH SIDELITE AS SHOWN ON PLANS. |
| |
| B) OVERHEAD GARAGE DOOR AS SHOWN ON PLANS. |
| |
| C) SINGLE HUNG WINDOWS AS SHOWN ON PLANS. |
| |
| D) SLIDING GLASS DOORS AS SHOWN ON PLANS. |
| |
| E) HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE |
| IMPACT GLAZING. AND PROVIDE COMPLETE INSTALLATION |
| SCHEDULE. SEE CITY SAMPLE. |
| |
| F) ROOF SHINGLES AS SHOWN ON PLANS. |
| |
| G) GABLE VENT AS SHOWN ON THE FRONT ELEVATION. |
| |
| H) PRECAST LINTELS AS SPECIFIED ON PLANS. |
| |
| 10- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| |
| 11- PROVIDE SITE PLANS OR SURVEY SHOWING THE PROPOSED |
| HOUSE AND THE PROPERTY LINES AS REQUIRED BY SEC. |
| 107.3.5.3(1) CITY AMENDMENTS. |
| |
| 12- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| COLONIAL SHUTTERS SHOWN ON THE FRONT ELEVATION. SPECIFY |
| SHUTTERS MATERIAL AND FASTENING SPECIFICATIONS. SEC. |
| R301.1 FBC-RESIDENTIAL. |
| |
| 13- GABLE END DETAIL ON SHEET T-1: |
| A) SPECIFY STUCCO THICKNESS (7/8") AS REQUIRED BY TABLE |
| R702.1(1) FBC-RESIDENTIAL. |
| |
| B) SPECIFY TWO LAYERS OF WATER-RESISTIVE BARRIERS AS |
| REQUIRED BY SEC. R703.6.3 FBC-RESIDENTIAL. |
| |
| 14- PROVIDE COMPLETE GARAGE DOOR STRUCTURAL BUCK |
| DETAIL. SPECIFY BUCK SIZE AND FASTENER TYPE AND |
| SPACING. SEC. R301.1 FBC-RESIDENTIAL. |
| |
| ****PLEASE PROVIDE RESPONSE LETTEER ADDRESSING EACH |
| COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. |
| ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| FOR REFERENCE. |
| |