Plan Review Details - Permit 17111142
Plan Review Stops For Permit 17111142 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2018-12-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-12-10 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-12-07 |
Time |
16:11 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-11-14 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-11-13 |
Time |
18:58 |
Sent To |
I |
|
Notes |
2018-11-14 09:21:14 | PLAN | | REVIEW COMMENTS | | 3611 S. FLAGLER DRIVE | | "THE CRYSTAL" 6 UNIT, 7 STOREY R-2 (CONDO) | | AE FLOOD ZONE | | | | 5TH REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) NOT ADDRESSED. NEW COMMENTS: THRESHOLD BUILDINGS | | REQUIRE THREE SETS OF CONSTRUCTION DOCUMENTS. ONLY TWO | | SETS OF THE PILE SURVEYS WERE SUBMITTED. THE LETTER | | FROM THE ENGINEER, RONALD M. JEZERINAC P.E., STATES | | THAT THE PILE SURVEYS THAT THEY REVIEWED HAVE HIS SHOP | | DRAWING APPROVAL STAMP. THE ONES THAT WERE SUBMITTED DO | | NOT HAVE SHOP DRAWING REVIEW STAMPS ON THEM. | | -FBC 107.2.1.3 PROVIDE CERTIFICATION DOCUMENTS FROM THE | | THRESHOLD INSPECTOR THAT HAVE BEEN REVIEWED AND | | ACCEPTED BY THE DESIGNER OF RECORD ATTESTING THAT THE | | PRODUCTION PILES AND PILE CAPS HAVE BEEN INSPECTED AND | | ARE INSTALLED PER THE PLANS FROM THE DESIGNER OF | | RECORD. | | | | 2) NOT ADDRESSED. NEW COMMENT: THE (3) THRESHOLD | | INPECTION PLANS THAT WERE SUBMITTED HAVE DIGITAL | | SIGNATURES, WHICH ARE ONLY ACCEPTABLE FOR | | ELECTRONICALLY SUBMITTED DOCUMENTS. | | -FBC 110.3.7 SUBMIT THREE SETS OF A THRESHOLD | | INSPECTION PLAN FROM THE NEW DESIGNER OF RECORD. THE | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURES ARE REQUIRED | | ON PAPER DOCUMENTS PER FAC 61G15-23.003 | | | | 3) NOT ADDRESSED. NEW COMMENT: I DID NOT SEE TERMITE | | PROTECTION SPECIFIED ON THE PLANS. | | -SHOW COMPLIANCE WITH FBC1816.1 TERMITE PROTECTION. | | | | 4) ADDRESSED. I REDLINED SHEET A101 TO REFER TO REVISED | | SHEETS A101 AND S3.1. | | -FBC 107.2.1THERE ARE SOME DISCREPANCIES BETWEEN THE | | ARCHITECTURAL PLANS AND THE STRUCTURAL PLANS THAT NEED | | TO BE ADDRESSED. ON SHEET S3.1 THE OPENING AND STAIRS | | ARE SHOWN ON THE WEST SIDE OF THE FIRE PUMP ROOM. THE | | SITE PLANS AND SHEETS A101 AND A201 SHOW THE DOOR ON | | THE SOUTH END OF THE FIRE PUMP ROOM. | | | | 5) NEW COMMENTS: THRESHOLD BUILDINGS REQUIRE THREE (3) | | SETS OF CONSTRUCTION DOCUMENTS TO BE SUBMITTED FOR | | REVIEW. ONLY TWO SETS OF THE GEOTECHNICAL REPORT, THE | | SITE-SPECIFIC FLOOD ZONE ANALYSIS THE LETTERS FROM | | NUTTING ENGINEERS AND JEZERINAC GROUP WERE SUBMITTED. | | FBC 107.1 | | | | 6) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | COMMENTS HAS BEEN ADDRESSED. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2018-10-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-10-25 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-10-25 |
Time |
17:32 |
Sent To |
I |
|
Notes |
2018-10-25 17:14:29 | PLAN | | REVIEW COMMENTS | | 3611 S. FLAGLER DRIVE | | "THE CRYSTAL" 6 UNIT, 7 STOREY R-2 (CONDO) | | AE FLOOD ZONE | | | | 4TH REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC 107.2.1.3 PROVIDE CERTIFICATION DOCUMENTS FROM | | THE THRESHOLD INSPECTOR THAT HAVE BEEN REVIEWED AND | | ACCEPTED BY THE DESIGNER OF RECORD ATTESTING THAT THE | | PRODUCTION PILES AND PILE CAPS HAVE BEEN INSPECTED AND | | ARE INSTALLED PER THE PLANS FROM THE DESIGNER OF | | RECORD. | | | | 2) FBC 110.3.7 SUBMIT THREE SETS OF A THRESHOLD | | INSPECTION PLAN FROM THE NEW DESIGNER OF RECORD. THE | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURES ARE REQUIRED | | ON PAPER DOCUMENTS PER FAC 61G15-23.003 | | | | 3) SHOW COMPLIANCE WITH FBC1816.1 TERMITE PROTECTION. | | | | 4) FBC 107.2.1THERE ARE SOME DISCREPANCIES BETWEEN THE | | ARCHITECTURAL PLANS AND THE STRUCTURAL PLANS THAT NEED | | TO BE ADDRESSED. ON SHEET S3.1 THE OPENING AND STAIRS | | ARE SHOWN ON THE WEST SIDE OF THE FIRE PUMP ROOM. THE | | SITE PLANS AND SHEETS A101 AND A201 SHOW THE DOOR ON | | THE SOUTH END OF THE FIRE PUMP ROOM. | | | | 5) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | COMMENTS HAS BEEN ADDRESSED. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2018-05-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-05-29 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-05-23 |
Time |
08:04 |
Sent To |
|
|
Notes |
2018-05-29 11:37:46 | PLAN | | REVIEW COMMENTS | | 3611 S. FLAGLER DRIVE | | "THE CRYSTAL" 6 UNIT, 7 STOREY R-2 (CONDO) | | AE FLOOD ZONE | | | | 3RD REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | SEE SAME REVIEW COMMENTS FOR REVISION TO CHANGE PILE | | FOUNDATION SCOPE OF WORK TO INCLUDE BUILDING SHELL | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC 107.2.1.3 PROVIDE CERTIFICATION DOCUMENTS FROM | | THE THRESHOLD INSPECTOR THAT HAVE BEEN REVIEWED AND | | ACCEPTED BY THE DESIGNER OF RECORD ATTESTING THAT THE | | PRODUCTION PILES AND PILE CAPS HAVE BEEN INSPECTED AND | | ARE INSTALLED PER THE PLANS FROM THE DESIGNER OF | | RECORD. | | | | 2) ADDRESS THE IMPACT FEE REVIEW COMMENTS. BEFORE A | | PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES MUST BE | | PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE SET OF | | PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM BEACH | | COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH THE | | IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT MUST BE | | RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE THE | | BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | 3) FBC 110.3.7 SUBMIT THREE SETS OF A THRESHOLD | | INSPECTION PLAN FROM THE NEW DESIGNER OF RECORD. | | | | 4) NOTE: POST TENSION SLABS. 107.3.4.2 DEFERRED | | SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, DEFERRED | | SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN | | THAT ARE NOT SUBMITTED AT THE TIME OF THE APPLICATION | | AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL | | WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL | | ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING | | OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS | | ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE | | BUILDING OFFICIAL. | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | OFFICIAL. | | | | 5) FBC 3306.1 PROTECTION REQUIRED. PEDESTRIANS SHALL BE | | PROTECTED DURING CONSTRUCTION, REMODELING AND | | DEMOLITION ACTIVITIES AS REQUIRED BY THIS CHAPTER AND | | TABLE 3306.1. SIGNS SHALL BE PROVIDED TO DIRECT | | PEDESTRIAN TRAFFIC. | | FBC 3306.2 WALKWAYS. A WALKWAY SHALL BE PROVIDED FOR | | PEDESTRIAN TRAVEL IN FRONT OF EVERY CONSTRUCTION AND | | DEMOLITION SITE UNLESS THE APPLICABLE GOVERNING | | AUTHORITY AUTHORIZES THE SIDEWALK TO BE FENCED OR | | CLOSED. WALKWAYS SHALL BE OF SUFFICIENT WIDTH TO | | ACCOMMODATE THE PEDESTRIAN TRAFFIC, BUT IN NO CASE | | SHALL THEY BE LESS THAN 4 FEET (1219 MM) IN WIDTH. | | WALKWAYS SHALL BE PROVIDED WITH A DURABLE WALKING | | SURFACE. WALKWAYS SHALL BE ACCESSIBLE IN ACCORDANCE | | WITH CHAPTER 11 AND SHALL BE DESIGNED TO SUPPORT ALL | | IMPOSED LOADS AND IN NO CASE SHALL THE DESIGN LIVE LOAD | | BE LESS THAN 150 POUNDS PER SQUARE FOOT (PSF) (7.2 | | KN/M2). | | FBC 3306.5 BARRIERS. BARRIERS SHALL BE NOT LESS THAN 8 | | FEET (2438 MM) IN HEIGHT AND SHALL BE PLACED ON THE | | SIDE OF THE WALKWAY NEAREST THE CONSTRUCTION. BARRIERS | | SHALL EXTEND THE ENTIRE LENGTH OF THE CONSTRUCTION | | SITE. OPENINGS IN SUCH BARRIERS SHALL BE PROTECTED BY | | DOORS WHICH ARE NORMALLY KEPT CLOSED. | | FBC 3306.7 COVERED WALKWAYS. COVERED WALKWAYS SHALL | | HAVE A CLEAR HEIGHT OF NOT LESS THAN 8 FEET (2438 MM) | | AS MEASURED FROM THE FLOOR SURFACE TO THE CANOPY | | OVERHEAD. ADEQUATE LIGHTING SHALL BE PROVIDED AT ALL | | TIMES. COVERED WALKWAYS SHALL BE DESIGNED TO SUPPORT | | ALL IMPOSED LOADS. IN NO CASE SHALL THE DESIGN LIVE | | LOAD BE LESS THAN 150 PSF (7.2 KN/M2) FOR THE ENTIRE | | STRUCTURE. | | FBC 3306.8 REPAIR, MAINTENANCE AND REMOVAL. PEDESTRIAN | | PROTECTION REQUIRED BY THIS CHAPTER SHALL BE MAINTAINED | | IN PLACE AND KEPT IN GOOD ORDER FOR THE ENTIRE LENGTH | | OF TIME PEDESTRIANS ARE SUBJECT TO BEING ENDANGERED. | | THE OWNER OR THE OWNER?S AGENT, UPON THE COMPLETION OF | | THE CONSTRUCTION ACTIVITY, SHALL IMMEDIATELY REMOVE | | WALKWAYS, DEBRIS AND OTHER OBSTRUCTIONS AND LEAVE SUCH | | PUBLIC PROPERTY IN AS GOOD A CONDITION AS IT WAS BEFORE | | SUCH WORK WAS COMMENCED. | | | | 6) FBC 3307.1 PROTECTION REQUIRED. ADJOINING PUBLIC AND | | PRIVATE PROPERTY SHALL BE PROTECTED FROM DAMAGE DURING | | CONSTRUCTION, REMODELING AND DEMOLITION WORK. | | PROTECTION SHALL BE PROVIDED FOR FOOTINGS, FOUNDATIONS, | | PARTY WALLS, CHIMNEYS, SKYLIGHTS AND ROOFS. PROVISIONS | | SHALL BE MADE TO CONTROL WATER RUNOFF AND EROSION | | DURING CONSTRUCTION OR DEMOLITION ACTIVITIES. THE | | PERSON MAKING OR CAUSING AN EXCAVATION TO BE MADE SHALL | | PROVIDE WRITTEN NOTICE TO THE OWNERS OF ADJOINING | | BUILDINGS ADVISING THEM THAT THE EXCAVATION IS TO BE | | MADE AND THAT THE ADJOINING BUILDINGS SHOULD BE | | PROTECTED. SAID NOTIFICATION SHALL BE DELIVERED NOT | | LESS THAN 10 DAYS PRIOR TO THE SCHEDULED STARTING DATE | | OF THE EXCAVATION. | | | | 7) 3310.1 STAIRWAYS REQUIRED. WHERE A BUILDING HAS BEEN | | CONSTRUCTED TO A BUILDING HEIGHT OF 50 FEET (15 240 MM) | | OR FOUR STORIES, OR WHERE AN EXISTING BUILDING | | EXCEEDING 50 FEET (15 240 MM) IN BUILDING HEIGHT IS | | ALTERED, NO FEWER THAN ONE TEMPORARY LIGHTED STAIRWAY | | SHALL BE PROVIDED UNLESS ONE OR MORE OF THE PERMANENT | | STAIRWAYS ARE ERECTED AS THE CONSTRUCTION PROGRESSES. | | | | 8) FBC 107.2.1 THE SLAB ON GRADE NOTE ON SHEET S3.1 IS | | INCOMPLETE. | | | | 9) FBC 107.2.1THERE ARE SOME DISCREPANCIES BETWEEN THE | | ARCHITECTURAL PLANS AND THE STRUCTURAL PLANS THAT NEED | | TO BE ADDRESSED. | | A) SPIRAL STAIRS ARE SHOWN ON STRUCTURAL SHEETS S3.1 | | AND S3.2 IN THE GROUND FLOOR UNIT. ARCHITECTURAL SHEETS | | A101 AND A201 SHOW A CONVENTIAL STAIRWAY IN THE UNIT | | AND A WATER PUMP ROOM THAT IS NOT SHOWN ON THE | | STRUCTURAL SHEETS. | | B) A WATER FEATURE IS SHOWN ON THE ROOF ON SHEET S3.4 | | AND IS NOT SHOWN ON SHEET A701. | | | | 10) ADDRESS THE ART IN PUBLIC PLACES COMMENTS. THE CITY | | OF WEST PALM BEACH ART IN PUBLIC PLACES ORDINANCE | | REQUIREMENT THAT APPLIES TO ANY REMODEL OR NEW | | CONSTRUCTION PROJECT FOR WHICH THE PERMIT APPLICATION | | WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL PROJECT | | CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE. | | PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND | | CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, | | ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | PROJECT CONSTRUCTION COST. | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | PROJECTS. | | SEC. 78-129. - PUBLIC ART ASSESSMENT FOR PRIVATE | | DEVELOPMENT. | | (A) APPLICABILITY. THE PROVISIONS OF THIS ARTICLE AND | | THE PUBLIC ART ASSESSMENT SECTION SHALL APPLY TO ALL | | PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW | | CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN | | EXISTING BUILDING, WHERE TOTAL CONSTRUCTION COSTS ARE | | EQUAL TO OR GREATER THAN $750,000.00. ALL BUILDINGS | | WITHIN NEW PLANNED DEVELOPMENTS SHALL BE ASSESSED | | CUMULATIVELY TOWARDS THIS ART IN PUBLIC PLACES | | REQUIREMENT, EVEN IF THE BUILDINGS ARE PERMITTED | | SEPARATELY OR DEVELOPED IN PHASES. THE PROVISIONS OF | | THIS SECTION APPLY TO NEW DEVELOPMENT OR NEW | | CONSTRUCTION WITHIN EXISTING PLANNED DEVELOPMENTS. FOR | | CONTACT INFORMATION PLEASE CONTACT: | | MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR | | 822-1515 E-MAIL: [email protected] | | | | 11) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | COMMENTS HAS BEEN ADDRESSED. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-03-23 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-03-23 |
Time |
10:59 |
Sent To |
|
|
Notes |
2018-03-23 13:38:37 | ****PLAN REVIEW COMMENTS**** | | | | ART LANGE BUILDING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH, FL 33402 | | 561-805-6718 [email protected] | | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION W/2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | 2015 5TH EDITION | | | | SECOND REVIEW FOUNDATION FOR THE CRYSTAL 17111142 | | | | DATE: MARRCH 23,2018 | | | | PLAN REVIEW RESPONSES ARE ON TO IN CAPS. | | | | 1. OK ADDRESSED | | | | 2. OK RECIEVED FLOOD ZONE SITE SPEPCIFIC FLOD ZONE | | ANALYSIS AND ELEVATION CERTIFICATE. | | | | FLOOD ZONE CERTIFICATES | | | | 3. PARTIALLY ADDRESSED. | | | | SUBMIT ONLY THE DOCUMENTS REQUIRED FOR A FOUNDATION | | PERMIT. THE ENTIRE SET OF PLANS FOR THE MAIN BUILDING | | HAS BEEN SUBMITTED. | | SEE LIST ADDED BELOW. THIS IS A TYPICAL LIST OF | | REQUIRED ITEMS FOR A FOUNDATION PERMIT FOR YOUR | | REFERENCE. | | PERMIT APPLICATION WHICH STATES SCOPE (FOR FOUNDATION | | PERMIT, TYPICALLY FOOTINGS OR FOOTINGS AND SLAB) | | GEOTECHNICAL REPORT | | SURVEY DRAWING | | STORM WATER POLLUTION PREVENTION PLAN | | SITE PLAN | | 1ST FLOOR ARCHITECTURAL PLAN | | ARCHITECTURAL CROSS SECTION(S) OF THE BUILDING | | FOUNDATION PLAN | | FOUNDATION DETAILS AND CROSS SECTIONS | | STRUCTURAL ENGINEER'S GENERAL NOTES | | UNDERGROUND PLUMBING PLAN (IF APPLICABLE) | | ELECTRICAL PLAN SHOWING ANY UNDERGROUND CONDUIT (IF | | APPLICABLE) | | ELECTRICAL GROUNDING TO STEEL DETAIL, IF APPLICABLE (OR | | EXPLAIN WHY THIS IS NOT APPLICABLE FOR THIS PROJECT). | | IF REQUIRED, A DETAIL IS REQUIRED AS A REVIEW, PERMIT, | | AND INSPECTION ARE REQUIRED PRIOR TO CONCRETE POUR | | PLAN SHOWING UNDERGROUND FIRE LINE | | THRESHOLD INSPECTION PLAN OR RESIDENT INSPECTION PLAN | | (AS APPLICABLE) | | SI OR RESIDENT INSPECTOR AGREEMENT (AS APPLICABLE) | | THRESHOLD STATEMENT ON PLAN (IF APPLICABLE) | | THREE SETS OF PLANS FOR RESIDENT INSPECTOR OR THRESHOLD | | PROJECT | | | | PROVIDE ONLY THE INFORMATION REQUIRED FOR A FOUNDATION | | PLAN REVIEW. THE ENTIRE BUILDING PACKAGE WAS SUBMITTED. | | INCLUDE THE ABOVE INFORMATION AS WELL AS ALL STRUCTURAL | | DETAILS AND ELEVATIONS ALONG WITH THE ELECTRICAL AND | | PLUMBING PAGES AS NEEDED. | | | | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | | 4. OK ADDRESSED. | | THIS BUILDING QUALIFIES AS A THRESHOLD BUILDING. | | THRESHOLD BUILDING MEANING ANY BUILDING WHICH IS | | GREATER THAN (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH | | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION THAT EXCEEDS | | 5,000 SQ. FT. IN AREA AND AN OCCUPANT CONTENT OF | | GREATER THAN 500 PERSONS. | | | | 4A. OK ADDRESSED | | THRESHOLD INSPECTION PLAN FL S. S. 553.71(7). 2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1, ADMINISTRATION 109.3.6.1 THE ENFORCING | | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | WITH THE PERMITTED DOCUMENTS. | | | | 4B. OK ADDRESSED | | THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | CONSTRUCTION SERVICES DEPARTMENT REQUESTS FOR THRESHOLD | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FS | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS | | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH | | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND | | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE | | PLACE. | | | | 4C. OK ADDRESSED | | FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF | | INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME | | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED | | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL | | REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN | | INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | MEETING THE ABOVE CRITERIA. | | | | 5. OK ADDRESSED | | PLEASE SHOW HOW SLOPE LIMITS WILL BE ACHIEVED. FBC | | 3304.1.1 SLOPE LIMITS. SLOPES FOR PERMANENT FILL SHALL | | NOT BE STEEPER THAN ONE UNIT VERTICAL IN TWO UNITS | | HORIZONTAL (50-PERCENT SLOPE). CUT SLOPES FOR PERMANENT | | EXCAVATIONS SHALL NOT BE STEEPER THAN ONE UNIT VERTICAL | | IN TWO UNITS HORIZONTAL (50-PERCENT SLOPE). DEVIATION | | FROM THE FOREGOING LIMITATIONS FOR CUT SLOPES SHALL BE | | PERMITTED ONLY UPON THE PRESENTATION OF A SOIL | | INVESTIGATION REPORT ACCEPTABLE TO THE BUILDING | | OFFICIAL. | | | | 6. OK ADDRESSED | | WHEN EXCAVATING WILL THE EXCESS SOILS BE STORED ON | | SITE? FBC 3304.1.2 SURCHARGE. NO FILL OR OTHER | | SURCHARGE LOADS SHALL BE PLACED ADJACENT TO ANY | | BUILDING OR STRUCTURE UNLESS SUCH BUILDING OR STRUCTURE | | IS CAPABLE OF WITHSTANDING THE ADDITIONAL LOADS CAUSED | | BY THE FILL OR SURCHARGE. EXISTING FOOTINGS OR | | FOUNDATIONS WHICH CAN BE AFFECTED BY ANY EXCAVATION | | SHALL BE UNDERPINNED ADEQUATELY OR OTHERWISE PROTECTED | | AGAINST SETTLEMENT AND SHALL BE PROTECTED AGAINST LATER | | MOVEMENT. | | | | 7. OK ADDRESSED | | PLEASE PROVIDE COMPLIANCE WITH: POLLUTION PREVENTION | | PLAN. FBC 3307.1 PROTECTION REQUIRED. ADJOINING PUBLIC | | AND PRIVATE PROPERTY SHALL BE PROTECTED FROM DAMAGE | | DURING CONSTRUCTION, REMODELING AND DEMOLITION WORK. | | PROVISIONS SHALL BE MADE TO CONTROL WATER RUNOFF AND | | EROSION DURING CONSTRUCTION OR DEMOLITION ACTIVITIES. | | THE PERSON MAKING OR CAUSING AN EXCAVATION TO BE MADE | | SHALL PROVIDE WRITTEN NOTICE TO THE OWNERS OF ADJOINING | | BUILDINGS ADVISING THEM THAT THE EXCAVATION IS TO BE | | MADE AND THAT THE ADJOINING BUILDINGS SHOULD BE | | PROTECTED. SAID NOTIFICATION SHALL BE DELIVERED NOT | | LESS THAN 10 DAYS PRIOR TO THE SCHEDULED STARTING DATE | | OF THE EXCAVATION. | | FBC 109.3.10 IMPACT OF CONSTRUCTION. ALL CONSTRUCTION | | ACTIVITY REGULATED BY THIS CODE SHALL BE PERFORMED IN A | | MANNER SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF | | ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED TO | | AFFECT SAID PROPERTY PURSUANT TO CONSENT BY THE | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS | | INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF DUST, | | NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS | | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, | | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, PATIOS, | | DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ. | | FT. OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | OF THE FINAL INSPECTION. | | | | 8. OK ADDRESSED | | FBC 3306.9 ADJACENT TO EXCAVATIONS. EVERY EXCAVATION ON | | A SITE LOCATED 5 FEET (1524 MM) OR LESS FROM THE STREET | | LOT LINE SHALL BE ENCLOSED WITH A BARRIER NOT LESS THAN | | 6 FEET (1829 MM) HIGH. WHERE LOCATED MORE THAN 5 FEET | | (1524 MM) FROM THE STREET LOT LINE, A BARRIER SHALL BE | | ERECTED WHEN REQUIRED BY THE BUILDING OFFICIAL. | | BARRIERS SHALL BE OF ADEQUATE STRENGTH TO RESIST WIND | | PRESSURE AS SPECIFIED IN CHAPTER 16. | | | | 9. OK ADDRESSED TRAILER PERMIT IN APPLICATION | | ALL CONSTRUCTION TRAILERS (MOBILE OR MODULAR BUILDINGS) | | THAT ARE GOING TO HAVE MEETING IN THEM WILL BE REQUIRED | | TO GET A PERMIT, 102.2(E) MOBILE OR MODULAR STRUCTURES | | USED AS TEMPORARY OFFICES, EXCEPT THAT THE PROVISIONS | | OF PART V FS 553.501-553.513, FLORIDA STATUTES, | | RELATING TO ACCESSIBILITY BY PERSONS WITH DISABILITIES, | | AND PERMITS SHALL BE REQUIRED FOR STRUCTURAL SUPPORT | | AND TIE DOWN, ELECTRICAL SUPPLY, AND ALL UTILITY | | CONNECTIONS TO SUCH MOBILE OR MODULAR STRUCTURES. | | | | 10. OK ADDRESSED RECEIVED SOILS REPORT. | | PROVIDE SOILS EXPLORATION REPORT THAT WAS COMPLETED BY | | NUTTING ENGINEERING. | | GEOTECHNICAL INVESTIGATIONS SHALL BE CONDUCTED IN | | ACCORDANCE WITH FBC SECTION 1803.2 AND REPORTED IN | | ACCORDANCE WITH SECTION 1803.6. WHERE REQUIRED BY THE | | BUILDING OFFICIAL OR WHERE GEOTECHNICAL INVESTIGATIONS | | INVOLVE IN-SITU TESTING, LABORATORY TESTING OR | | ENGINEERING CALCULATIONS, SUCH INVESTIGATIONS SHALL BE | | CONDUCTED BY A REGISTERED DESIGN PROFESSIONAL. | | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | | | 11. NOT ADDRESSED. SEE IMPACT FEE STOP ADDED. | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION. | | | | 12. OK ADDRESSED | | FBC 105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL OF | | THE APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING | | OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE | | CONSTRUCTION OF FOUNDATIONS OR ANY OTHER PART OF A | | BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS | | FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION | | OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED | | AT THE HOLDERS OWN RISK WITH THE BUILDING OPERATION AND | | WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | THE PERMIT PACKAGE. | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | | DEVELOPMENT SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-12-05 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2017-12-05 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-03-23 |
Time |
11:16 |
Sent To |
|
|
Notes |
2017-12-05 08:55:39 | ****PLAN REVIEW COMMENTS**** | | | | ART LANGE BUILDING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH, FL 33402 | | 561-805-6718 [email protected] | | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION W/2010 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | 2015 5TH EDITION | | | | 1ST REVIEW FOUNDATION FOR THE CRYSTAL 17111142 | | | | DATE: DECEMBER 5, 2017 | | | | 1. NOTICE ONLY; THE CITY OF WEST PALM BEACH ART IN | | PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES TO ANY | | REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH THE | | PERMIT APPLICATION WAS SUBMITTED AFTER 7/1/14, AND THE | | TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR | | GREATER THAN $500,000. PER CITY OF WEST PALM BEACH | | ORDINANCE NO. 4504-14, AND CITY OF WEST PALM BEACH CODE | | OF ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES, SECTION | | 78-123(A) AND SECTION 78-126(A), THE ART ASSESSMENT IS | | 1% OF THE TOTAL PROJECT CONSTRUCTION COST. | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | PROJECTS. | | | | 2. FLOOD ZONE CERTIFICATES | | | | FBC 1612 AND CITY OF WPB CODE OF ORDINANCES SECTION | | 94-546. STRUCTURE IS LOCATED IN FLOOD ZONE "A". A FLOOD | | ELEVATION CERTIFICATE WILL BE REQUIRED. | | | | THE FLOOD ZONE MAPS WERE UPDATED OCTOBER 5, 2017. | | PLEASE UPDATE THE SURVEY AND PLANS TO NAV 88. | | | | AFTER OCTOBER 11, 2017 AN ADDITIONAL ONE FOOT OF FREE | | BOARD WILL BE REQUIRED OR 2 FEET OF FREE BOARD ABOVE | | THE DESIGN FLOOD ELEVATION. | | | | DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE | | REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES | | REQUIRED: | | | | (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE | | PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR | | HEIGHT. | | | | (2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND | | ELEVATION CERTIFICATE IS REQUIRED. | | | | (3) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY | | OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE | | CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR | | ATTENDANTS A/C PADS OR OTHER SLABS FOR GENERATORS. | | | | 3. IT APPEARS THAT THESE PLANS HAVE BEEN SUBMITTED TO | | LOCK INTO THE CURRENT CODE CYCLE. PLEASE UPDATE THE | | PLANS TO REFLECT THE FLOOD ZONE INFORMATION MENTIONED | | ABOVE. | | PROVIDE ONLY THE INFORMATION REQUIRED FOR A FOUNDATION | | PLAN REVIEW. THE ENTIRE BUILDING PACKAGE WAS SUBMITTED. | | INCLUDE THE ABOVE INFORMATION AS WELL AS ALL STRUCTURAL | | DETAILS AND ELEVATIONS ALONG WITH THE ELECTRICAL AND | | PLUMBING PAGES AS NEEDED. | | | | INCLUDE AT WHAT LEVEL THE FOUNDATION BE BUILT TO. WILL | | IT INCLUDE JUST THE SLAB AND SUPPORTING STRUCTURE OR | | WILL COLUMNS BE INCLUDED FOR EXAMPLE. | | | | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | | 4. THIS BUILDING QUALIFIES AS A THRESHOLD BUILDING. | | ?THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS | | GREATER THAN (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH | | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION THAT EXCEEDS | | 5,000 SQ. FT. IN AREA AND AN OCCUPANT CONTENT OF | | GREATER THAN 500 PERSONS. | | | | 4A. THRESHOLD INSPECTION PLAN FL S. S. 553.71(7). 2010 | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION 109.3.6.1 THE ENFORCING | | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | WITH THE PERMITTED DOCUMENTS. | | | | 4B. THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | CONSTRUCTION SERVICES DEPARTMENT REQUESTS FOR THRESHOLD | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FS | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS | | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH | | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND | | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE | | PLACE. | | | | 4C. FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | RESUME MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | WILL REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | MEETING THE ABOVE CRITERIA. | | | | 5. PLEASE SHOW HOW SLOPE LIMITS WILL BE ACHIEVED. FBC | | 3304.1.1 SLOPE LIMITS. SLOPES FOR PERMANENT FILL SHALL | | NOT BE STEEPER THAN ONE UNIT VERTICAL IN TWO UNITS | | HORIZONTAL (50-PERCENT SLOPE). CUT SLOPES FOR PERMANENT | | EXCAVATIONS SHALL NOT BE STEEPER THAN ONE UNIT VERTICAL | | IN TWO UNITS HORIZONTAL (50-PERCENT SLOPE). DEVIATION | | FROM THE FOREGOING LIMITATIONS FOR CUT SLOPES SHALL BE | | PERMITTED ONLY UPON THE PRESENTATION OF A SOIL | | INVESTIGATION REPORT ACCEPTABLE TO THE BUILDING | | OFFICIAL. | | | | 6. WHEN EXCAVATING WILL THE EXCESS SOILS BE STORED ON | | SITE? FBC 3304.1.2 SURCHARGE. NO FILL OR OTHER | | SURCHARGE LOADS SHALL BE PLACED ADJACENT TO ANY | | BUILDING OR STRUCTURE UNLESS SUCH BUILDING OR STRUCTURE | | IS CAPABLE OF WITHSTANDING THE ADDITIONAL LOADS CAUSED | | BY THE FILL OR SURCHARGE. EXISTING FOOTINGS OR | | FOUNDATIONS WHICH CAN BE AFFECTED BY ANY EXCAVATION | | SHALL BE UNDERPINNED ADEQUATELY OR OTHERWISE PROTECTED | | AGAINST SETTLEMENT AND SHALL BE PROTECTED AGAINST LATER | | MOVEMENT. | | | | 7. PLEASE PROVIDE COMPLIANCE WITH: POLLUTION PREVENTION | | PLAN. FBC 3307.1 PROTECTION REQUIRED. ADJOINING PUBLIC | | AND PRIVATE PROPERTY SHALL BE PROTECTED FROM DAMAGE | | DURING CONSTRUCTION, REMODELING AND DEMOLITION WORK. | | PROVISIONS SHALL BE MADE TO CONTROL WATER RUNOFF AND | | EROSION DURING CONSTRUCTION OR DEMOLITION ACTIVITIES. | | THE PERSON MAKING OR CAUSING AN EXCAVATION TO BE MADE | | SHALL PROVIDE WRITTEN NOTICE TO THE OWNERS OF ADJOINING | | BUILDINGS ADVISING THEM THAT THE EXCAVATION IS TO BE | | MADE AND THAT THE ADJOINING BUILDINGS SHOULD BE | | PROTECTED. SAID NOTIFICATION SHALL BE DELIVERED NOT | | LESS THAN 10 DAYS PRIOR TO THE SCHEDULED STARTING DATE | | OF THE EXCAVATION. | | FBC 109.3.10 IMPACT OF CONSTRUCTION. ALL CONSTRUCTION | | ACTIVITY REGULATED BY THIS CODE SHALL BE PERFORMED IN A | | MANNER SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF | | ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED TO | | AFFECT SAID PROPERTY PURSUANT TO CONSENT BY THE | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS | | INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF DUST, | | NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS | | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, | | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, PATIOS, | | DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ. | | FT. OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | OF THE FINAL INSPECTION. | | | | 8. FBC 3306.9 ADJACENT TO EXCAVATIONS. EVERY EXCAVATION | | ON A SITE LOCATED 5 FEET (1524 MM) OR LESS FROM THE | | STREET LOT LINE SHALL BE ENCLOSED WITH A BARRIER NOT | | LESS THAN 6 FEET (1829 MM) HIGH. WHERE LOCATED MORE | | THAN 5 FEET (1524 MM) FROM THE STREET LOT LINE, A | | BARRIER SHALL BE ERECTED WHEN REQUIRED BY THE BUILDING | | OFFICIAL. BARRIERS SHALL BE OF ADEQUATE STRENGTH TO | | RESIST WIND PRESSURE AS SPECIFIED IN CHAPTER 16. | | | | 9. ALL CONSTRUCTION TRAILERS (MOBILE OR MODULAR | | BUILDINGS) THAT ARE GOING TO HAVE MEETING IN THEM WILL | | BE REQUIRED TO GET A PERMIT, 102.2(E) MOBILE OR MODULAR | | STRUCTURES USED AS TEMPORARY OFFICES, EXCEPT THAT THE | | PROVISIONS OF PART V FS 553.501-553.513, FLORIDA | | STATUTES, RELATING TO ACCESSIBILITY BY PERSONS WITH | | DISABILITIES, AND PERMITS SHALL BE REQUIRED FOR | | STRUCTURAL SUPPORT AND TIE DOWN, ELECTRICAL SUPPLY, AND | | ALL UTILITY CONNECTIONS TO SUCH MOBILE OR MODULAR | | STRUCTURES. | | | | 10. PROVIDE SOILS EXPLORATION REPORT THAT WAS COMPLETED | | BY NUTTING ENGINEERING. | | GEOTECHNICAL INVESTIGATIONS SHALL BE CONDUCTED IN | | ACCORDANCE WITH FBC SECTION 1803.2 AND REPORTED IN | | ACCORDANCE WITH SECTION 1803.6. WHERE REQUIRED BY THE | | BUILDING OFFICIAL OR WHERE GEOTECHNICAL INVESTIGATIONS | | INVOLVE IN-SITU TESTING, LABORATORY TESTING OR | | ENGINEERING CALCULATIONS, SUCH INVESTIGATIONS SHALL BE | | CONDUCTED BY A REGISTERED DESIGN PROFESSIONAL. | | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | | | 11. BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION. | | | | 12. FBC 105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL | | OF THE APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING | | OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE | | CONSTRUCTION OF FOUNDATIONS OR ANY OTHER PART OF A | | BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS | | FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION | | OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED | | AT THE HOLDER?S OWN RISK WITH THE BUILDING OPERATION | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | THE PERMIT PACKAGE. | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | | DEVELOPMENT SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-05-18 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-05-18 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-05-18 |
Time |
12:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-04-02 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-04-02 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-04-02 |
Time |
10:47 |
Sent To |
|
|
Notes |
2018-04-02 14:34:58 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | BE ADVISED THIS PLAN REVIEW IS NOT A FULL REVIEW AND IS | | BASED ON ITEMS NECESSARY FOR FOUNDATION PERMIT ONLY. | | THE FULL REVIEW WILL BE COMPLETED UNDER THE MAIN | | PERMIT. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. PROVIDE DETAILS OF THE SECOND POWER SOURCE REQUIRED | | FOR FIRE PUMP. NEC 695.3(B) (NOT PROVIDED. FIRE PUMP | | REQUIRES A RELIABLE POWER SOURCE AND THE CITY DOES NOT | | CONSIDER FPL AS RELIABLE, THEREFORE A GENERATOR OR | | OTHER MEANS OF ALTERNATE POWER IS REQUIRED.) | | 2. FEEDER TO THE FIRE PUMP IS NOT PERMITTED TO BE RUN | | THROUGH THE BUILDING. PROVIDE CORRECTION. NEC 695.6, | | 695.4(B)(2), 230.79 (NO COMMENT RESPONSE PROVIDED. IF | | THIS FEED IS INSTALLED AS SHOWN CURRENTLY, IT: "SHALL | | BE INSTALLED USING ONE OF THE FOLLOWING METHODS: (1) BE | | ENCASED IN A MINIMUM 50 MM (2 IN.) OF CONCRETE | | (2) BE PROTECTED BY A FIRE-RATED ASSEMBLY LISTED TO | | ACHIEVE A MINIMUM FIRE RATING OF 2 HOURS AND DEDICATED | | TO THE FIRE PUMP CIRCUIT(S)(3) BE A LISTED ELECTRICAL | | CIRCUIT PROTECTIVE SYSTEM WITH A MINIMUM 2-HOUR FIRE | | RATING." NEC 695.6(A)(2) ) | | 3. IF A DISCONNECT FOR THE FIRE PUMP IS TO BE INSTALLED | | EVEN THOUGH IT IS NOT REQUIRED, IT MUST BE IN A REMOTE | | LOCATION FROM THE SERVICE DISCONNECTS. PROVIDE | | CORRECTION. NEC 695.4(B)(3), 230.72(B) (STILL SHOWN IN | | SAME LOCATION AS MAIN # 1, IT IS ALSO SHOWN WITH 2 | | MEANS OF DISCONNECTTHAT ARE NOT FUSED, WHICH IS A CODE | | VIOLATION) | | 4. PROVIDE FIRE PUMP SPEC SHEET, DETAILING THE LOCKED | | ROTOR CURRENT OF FIRE PUMP MOTOR. INCLUDE ANY DETAILS | | OF ELECTRICAL LOAD FOR ASSOCIATED EQUIPMENT. NEC 110.3, | | 695.10 (NOT PROVIDED) | | 5. RISER DIAGRAM SHOWS THE FIRE PUMP CONTROLLER IN THE | | PUMP ROOM. HOWEVER, THE PLUMBING PLAN SHOW THE DOMESTIC | | WATER PUMPS IN THIS ROOM, AND IT APPEARS THAT THE | | CLEARANCES REQUIRED ARE NOT POSSIBLE FOR THIS SIZE | | ROOM. PROVIDE CLARIFICATION. NEC 110.26; FBC 107.2.1 | | (NO RESPONSE PROVIDED) | | 6. PROVIDE ACCURATE LOAD CALCULATION FOR ENTIRE | | SERVICE. THE LOAD CALCULATION PROVIDED REFERENCES NEC | | 220.32, WHICH DOES NOT EXIST. ADDITIONALLY, THE FULL | | HOUSE LOAD IS NOT INCLUDED IN THE CALCULATION. PROVIDE | | CLARIFICATION AND CORRECTIONS. NEC 220 (LOAD | | CALCULATION INCORRECT, ALL LOADS IN HOUSE PANEL NOT | | INCLUDED IN LOAD CALC , NEC 220.32 SHOWN FOR MAIN # 1 | | LOAD CALC DOES NOT EXIST, PROVIDE CORRECT CODE | | REFERENCE.) | | | | NEW COMMENTS: | | | | 7. COVER SHEET STATES THAT PLAN IS DESIGNED PER THE | | 2014 FBC RESIDENTIAL. THE PROVISIONS OF THE FLORIDA | | BUILDING CODE, RESIDENTIAL SHALL APPLY TO THE | | CONSTRUCTION, ALTERATION, MOVEMENT, ENLARGEMENT, | | REPLACEMENT, REPAIR, EQUIPMENT, USE AND OCCUPANCY, | | LOCATION, REMOVAL AND DEMOLITION OF DETACHED ONE- AND | | TWO-FAMILY DWELLINGS AND TOWNHOUSES NOT MORE THAN THREE | | STORIES ABOVE GRADE PLANE IN HEIGHT WITH A SEPARATE | | MEANS OF EGRESS AND THEIR ACCESSORY STRUCTURES NOT MORE | | THAN THREE STORIES ABOVE GRADE PLANE IN HEIGHT. PROVIDE | | CORRECTION. FBC RE R101.2 | | 8. PLEASE BE ADVISED THAT SOME COMMENT HAV NOT BEEN | | ADDRESSED FOR TWO REVIEWS. IF UPON THE THIRD REVIEW, IF | | IT IS NECESSARY TO REJECT THE SUBMITTED PLAN A THIRD | | TIME FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW IS | | REQUIRED. FLORIDA STATUTES STATE: ?WITH RESPECT TO | | EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B)? | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-12-14 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-12-14 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-12-14 |
Time |
08:24 |
Sent To |
|
|
Notes |
2017-12-14 14:07:35 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | BE ADVISED THIS PLAN REVIEW IS NOT A FULL REVIEW AND IS | | BASED ON ITEMS NECESSARY FOR FOUNDATION PERMIT ONLY. | | THE FULL REVIEW WILL BE COMPLETED UNDER THE MAIN | | PERMIT. | | | | 1. PROVIDE DETAILS OF THE SECOND POWER SOURCE REQUIRED | | FOR FIRE PUMP. NEC 695.3(B) | | 2. FEEDER TO THE FIRE PUMP IS NOT PERMITTED TO BE RUN | | THROUGH THE BUILDING. PROVIDE CORRECTION. NEC 695.6, | | 695.4(B)(2), 230.79 | | 3. IF A DISCONNECT FOR THE FIRE PUMP IS TO BE INSTALLED | | EVEN THOUGH IT IS NOT REQUIRED, IT MUST BE IN A REMOTE | | LOCATION FROM THE SERVICE DISCONNECTS. PROVIDE | | CORRECTION. NEC 695.4(B)(3), 230.72(B) | | 4. PROVIDE FIRE PUMP SPEC SHEET, DETAILING THE LOCKED | | ROTOR CURRENT OF FIRE PUMP MOTOR. INCLUDE ANY DETAILS | | OF ELECTRICAL LOAD FOR ASSOCIATED EQUIPMENT. NEC 110.3, | | 695.10 | | 5. RISER DIAGRAM SHOWS THE FIRE PUMP CONTROLLER IN THE | | PUMP ROOM. HOWEVER, THE PLUMBING PLAN SHOW THE DOMESTIC | | WATER PUMPS IN THIS ROOM, AND IT APPEARS THAT THE | | CLEARANCES REQUIRED ARE NOT POSSIBLE FOR THIS SIZE | | ROOM. PROVIDE CLARIFICATION. NEC 110.26; FBC 107.2.1 | | 6. PROVIDE ACCURATE LOAD CALCULATION FOR ENTIRE | | SERVICE. THE LOAD CALCULATION PROVIDED REFERENCES NEC | | 220.32, WHICH DOES NOT EXIST. ADDITIONALLY, THE FULL | | HOUSE LOAD IS NOT INCLUDED IN THE CALCULATION. PROVIDE | | CLARIFICATION AND CORRECTIONS. NEC 220 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2018-04-09 |
Time |
|
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2018-04-09 |
Time |
|
Sent To |
ENG |
|
Notes |
2018-04-09 15:35:00 | CALL 811 LOCATES | | | | SWPPP SHOULD BE ON-SITE AT ALL TIMES. | | | | MANNY GONZALEZ | | SENIOR ENGINEERING PROJECT COORDINATOR | | PUBLIC WORKS DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | EMAIL: [email protected] | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | /FORMS,-PERMITS-APPLICATIONS | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2017-12-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-12-14 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-12-14 |
Time |
09:10 |
Sent To |
|
|
Notes |
2017-12-14 09:11:03 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | APPLICATION IF REQUIRED | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | /FORMS,-PERMITS-APPLICATIONS | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | MAIN PHONE: (561) 822-1200 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-03-28 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-03-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-03-27 |
Time |
16:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-12-07 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2017-12-07 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2017-12-05 |
Time |
11:49 |
Sent To |
|
|
Notes |
2017-12-07 09:52:01 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE NO CIVIL DRAWINGS OR ANY OTHER DRAWING | | INDICATING THE LOCATION OF A FDC, FIRE HYDRANT OR | | PROPOSED UNDERGROUND FIRE LINE. | | | | ADDITIONALLY, PROVIDE A NOTE INDICATING THAT ALL FIRE | | LINE SHALL BE UNDER SEPARATE SHOP DRAWINGS IN | | COMPLINACE WITH NFPA 24, STANDARD FOR THE INSTALLATION | | OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES, | | 2010 EDITION. | | | | PLEASE PROVIDE SPECIFIC DETAILS. | | | | | | | | 2) THE ARE NO INDICATIONS OF GRADE SLOPES ON THE ACCESS | | ROAD AND/OR THE PREVIOUSLY DISCUSSED LOCATION OF FIRE | | APPARATUS AT THE WEST END OF THE BUILDING. IT WAS | | DISCUSSED THAT THAT AREA WOULD BE FLAT AND HAVE THE FDC | | AND FIRE HYDRANT LOCATED THERE.(SEE # 1) | | | | PLEASE PROVIDE SPECIFIC DETAILS. | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2018-12-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-12-10 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-11-29 |
Time |
11:17 |
Sent To |
|
|
Notes |
2018-12-03 11:18:07 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-11-14 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-11-07 |
Time |
16:04 |
Sent To |
|
|
Notes |
2018-11-08 16:04:47 | RESUB ROUTED TO RMCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2018-10-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-10-25 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-10-17 |
Time |
14:04 |
Sent To |
|
|
Notes |
2018-10-19 14:04:21 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-06-04 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-06-04 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-04-30 |
Time |
15:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-04-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-18 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-03-21 |
Time |
14:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-12-29 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-12-29 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-11-30 |
Time |
13:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2018-12-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-12-12 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-12-12 |
Time |
15:11 |
Sent To |
|
|
Notes |
2018-12-12 15:18:37 | MU-2018-16270, PAID $7984.78 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-03-23 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-03-23 |
Time |
12:49 |
Sent To |
|
|
Notes |
2018-03-23 12:53:35 | ART LANGE BUILDING PLANS EXAMINER | | 561-805-6667 [email protected] | | | | | | PROVIDE AN APPROVAL FROM PALM BEACH COUNTY IMPACT FEE | | OFFICE IF YOU WANT TO DEFER PAYING IMPACT FEES UNTILL | | THE MAIN BUILDING PERMIT IS ISSUED. PROVIDE THIS | | INFORMATION TO OUR OFFICE PRIOR TO ISSUANCE OF THE | | FOUNDATION PERMIT. | | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-12-04 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2017-12-04 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-12-04 |
Time |
14:02 |
Sent To |
P |
|
Notes |
2017-12-04 14:03:13 | ART LANGE BUILDING PLANS EXAMINER | | 561-805-6667 [email protected] | | | | | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION. |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
4 |
Status |
P |
Date |
2018-12-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-12-10 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-12-10 |
Time |
17:34 |
Sent To |
|
|
Notes |
2018-12-10 17:38:41 | BUILDING PROVISO | | | | 1) SOME OF THE PLANS SHOW THE FINISH FLOOR ELEVATION AT | | 0 FEET. SUBMIT REVISED PLANS TO SHOW THE FINISH FLOOR | | ELEVATION AT A MINIMUM OF 9 FEET NAVD AND NOT 0 FEET. |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
3 |
Status |
F |
Date |
2018-04-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-04-18 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-04-18 |
Time |
16:08 |
Sent To |
|
|
Notes |
2018-04-18 16:08:49 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | A SITE PLAN SHOWS PROPOSED FFE AT 9' NAVD88. | | | | THE ARCHITECTURAL PAGES SHOW FFE AT 0'0". PLEASE | | INCORPORATE THE PROPOSED FFE INTO THE ARCHITECTURAL OR | | STRUCTURAL DRAWINGS. THIS IS NOT A REQUIREMENT FOR THE | | FOUNDATION PERMIT, BUT WILL BE A REQUIREMENT FOR THE | | BUILDING PERMIT. | | | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
2 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-03-23 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-03-23 |
Time |
11:08 |
Sent To |
|
|
Notes |
2018-03-23 11:16:18 | SITE SPECIFIC FLOOD ZONE ANALYSIS REPORT HAS BEEN | | RECEIVED. | | THESE DESIGN FLOOD ELEVATION INCLUDING THE 2 FT. | | FREEBOARD IS 9.0 NAVD. |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2017-12-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-12-14 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-12-14 |
Time |
09:11 |
Sent To |
|
|
Notes |
2017-12-14 09:11:48 | SEE BUILDING REVIEW | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-06-04 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-06-04 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-06-04 |
Time |
08:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-04-10 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-04-10 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-04-10 |
Time |
06:46 |
Sent To |
|
|
Notes |
2018-04-10 09:01:15 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | PREVIOUS COMMENTS NOT ADDRESSED THEY CAN BE ADDRESSED | | UNDER THE MAIN PERMIT IF REFERENCED SHEETS ARE REMOVED | | AND THE FOLLOWING IS PROVIDED . | | 1. PROVIDE ISOMETRIC WITH UNDERGROUND PIPING ONLY FOR | | SANITARY, WATER AND STORM SHOWING DFU, PIPE SIZE AND | | SQFT FOR STORM DRAINS. PER WPB AMEND TO FBC | | 107.3.5.1.3(13) | | 2. PROVIDE FLOOR PLAN WITH UNDER GROUND PIPING ONLY. | | PER WPB AMEND TO FBC 107.2.1 | | | | PLUMBING COMMENTS: TO EXPEDITE APPROVAL OF THIS PERMIT | | I SUGGEST SCHEDULING A MEETING TO GO OVER COMMENTS SEE | | MY CONTACT INFO BELOW. | | | | 1. THIS BUILDING SHALL COMPLY WITH FHA. PER FAIR | | HOUSING ACCESSIBILITY GUIDELINES : SECTION 3. FAIR | | HOUSING ACT DESIGN AND CONSTRUCTION REQUIREMENTS | | | | THE REGULATIONS ISSUED BY THE DEPARTMENT AT 24 CFR | | 100/205 STATE: | | | | SECTION 100.205 DESIGN AND CONSTRUCTION REQUIREMENTS. | | (A) COVERED MULTIFAMILY DWELLINGS FOR FIRST OCCUPANCY | | AFTER MARCH 13, 1991, SHALL BE DESIGNED AND CONSTRUCTED | | TO HAVE AT LEAST ONE BUILDING ENTRANCE ON AN ACCESSIBLE | | ROUTE UNLESS IT IS IMPRACTICAL TO DO SO BECAUSE OF THE | | SITE. FOR PURPOSES OF THIS SECTION, A COVERED | | MULTIFAMILY DWELLING SHALL BE DEEMED TO BE DESIGNED AND | | CONSTRUCTED FOR FIRST OCCUPANCY ON OR BEFORE MARCH 13, | | 1991, IF THEY ARE OCCUPIED BY THAT DATE OR IF THE LAST | | BUILDING PERMIT OR RENEWAL THEREOF FOR THE COVERED | | MULTIFAMILY DWELLINGS IS ISSUED BY A STATE, COUNTY OR | | LOCAL GOVERNMENT ON OR BEFORE JANUARY 13, 1990. THE | | BURDEN OF ESTABLISHING IMPRACTICALITY BECAUSE OF | | TERRAIN OR UNUSUAL SITE CHARACTERISTICS IS ON THE | | PERSON OR PERSONS WHO DESIGNED OR CONSTRUCTED THE | | HOUSING FACILITY. | | | | A) INDICATE ON THE PLAN WHICH FHA DESIGN DOCUMENT WILL | | BE USED IN DESIGNING BUILDING TO MEET FHA REQUIREMENTS. | | PER WPB AMEND TO FBC 107.2.1 | | B) INDICATE ON THE PLAN HOW FHA REQUIREMENTS 1-5 WILL | | BE MET. | | C) SHOW ON THE PLANS THE DIMENSIONS OF THE MOUNTING | | HEIGHTS FOR THE GRAB BAR BACKING. PER FHA REQUIREMENT 6 | | D) INDICATE ON THE PLAN WHICH DESIGN SPEC WILL BE USED | | FOR THE BATHROOMS. PER FHA REQUIREMENT 7 | | E) SHOW ON THE PLAN THE CLEAR FLOOR SPACE REQUIRED AT | | THE FIXTURES IN THE BATHROOMS AND KITCHEN. PER FHA | | REQUIREMENT 7 | | F) SHOW ON THE PLANS THE DIMENSIONS FOR THE HEIGHT AND | | DEPTH OF THE VANITY OR WING WALL ADJACENT TO THE WATER | | CLOSET. PER FHA REQUIREMENT 7 | | | | 2. PLEASE INDICATE ON THE PLAN FOR FOUNDATION ONLY. PER | | WPB AMEND TO FBC 107.2.1 | | | | 3. SHT. A701 SHOW THE SQFT AT EACH ROOF DRAIN. PER WPB | | AMEND TO FBC 107.2.1 AND FBC PL CH 11 | | | | 4. ON SHT. P-1 AND P-5 IT SHOWS 685 SQFT ON 3 OF THE | | ROOF DRAINS ON SHT A701 IT SHOWS THOSE SAME ROOF AREAS | | AS 3 DIFFERENT SIZES PLEASE CLARIFY. PER WPB AMEND TO | | FBC 107.2.1 | | | | 5. SHT. P-1 PLEASE PLACE NOTE ON PLAN A SEPARATE PERMIT | | IS REQUIRED FOR BACKFLOW DEVICES. PER WPB UTILITIES | | DEPARTMENT | | | | 6. SHT. P-6 SHOW SIZE ON THE BRANCH'S ON WATER MAIN | | RISER. PER WPB AMEND TO FBC 107.2.1 | | | | 7.SHT. P-1 SHOWS THE HOT AND COLD WATER PIPING TO THE | | WATER HEATER ON THE GROUND FLOOR AS 1/2" THE ISOMETRIC | | SHOWS IT AT 3/4" PLEASE CLARIFY. PER WPB AMEND TO FBC | | 107.2.1 | | | | 8. PLEASE LABEL ALL ALL WASTE AND SOIL STACKS ON | | ISOMETRICS , RISERS AND FLOOR PLANS. PER WPB AMEND TO | | FBC 107.2.1 | | | | 9. SHT. P-7 SHOW BRANCH'S AND SIZE OF BRANCH ON THE | | RISERS. PER WPB AMEND TO FBC 107.2.1 | | | | 10. SHT. P-8 SHOWS 2 ROUND ROOF DRAINS FOR OBSERVATION | | DECK SHT. A701 SHOWS 3 LINEAR FLOOR DRAINS ON THE | | OBSERVATION DECK PLEASE CLARIFY. PER WPB AMEND TO FBC | | 107.2.1 | | | | 11. LABEL STORM RISER TO MATCH THE FLOOR PLAN. PER WPB | | AMEND TO FBC 107.2.1 | | | | 12. PLEASE SHOW PUMP AND DRAIN PIPING FOR ELEVATOR | | SUMP. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-12-20 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2017-12-20 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2017-12-20 |
Time |
06:18 |
Sent To |
|
|
Notes |
2017-12-20 08:35:08 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | PLUMBING COMMENTS: TO EXPEDITE APPROVAL OF THIS PERMIT | | I SUGGEST SCHEDULING A MEETING TO GO OVER COMMENTS SEE | | MY CONTACT INFO BELOW. | | | | 1. THIS BUILDING SHALL COMPLY WITH FHA. PER FAIR | | HOUSING ACCESSIBILITY GUIDELINES : SECTION 3. FAIR | | HOUSING ACT DESIGN AND CONSTRUCTION REQUIREMENTS | | | | THE REGULATIONS ISSUED BY THE DEPARTMENT AT 24 CFR | | 100/205 STATE: | | | | SECTION 100.205 DESIGN AND CONSTRUCTION REQUIREMENTS. | | (A) COVERED MULTIFAMILY DWELLINGS FOR FIRST OCCUPANCY | | AFTER MARCH 13, 1991, SHALL BE DESIGNED AND CONSTRUCTED | | TO HAVE AT LEAST ONE BUILDING ENTRANCE ON AN ACCESSIBLE | | ROUTE UNLESS IT IS IMPRACTICAL TO DO SO BECAUSE OF THE | | SITE. FOR PURPOSES OF THIS SECTION, A COVERED | | MULTIFAMILY DWELLING SHALL BE DEEMED TO BE DESIGNED AND | | CONSTRUCTED FOR FIRST OCCUPANCY ON OR BEFORE MARCH 13, | | 1991, IF THEY ARE OCCUPIED BY THAT DATE OR IF THE LAST | | BUILDING PERMIT OR RENEWAL THEREOF FOR THE COVERED | | MULTIFAMILY DWELLINGS IS ISSUED BY A STATE, COUNTY OR | | LOCAL GOVERNMENT ON OR BEFORE JANUARY 13, 1990. THE | | BURDEN OF ESTABLISHING IMPRACTICALITY BECAUSE OF | | TERRAIN OR UNUSUAL SITE CHARACTERISTICS IS ON THE | | PERSON OR PERSONS WHO DESIGNED OR CONSTRUCTED THE | | HOUSING FACILITY. | | | | A) INDICATE ON THE PLAN WHICH FHA DESIGN DOCUMENT WILL | | BE USED IN DESIGNING BUILDING TO MEET FHA REQUIREMENTS. | | PER WPB AMEND TO FBC 107.2.1 | | B) INDICATE ON THE PLAN HOW FHA REQUIREMENTS 1-5 WILL | | BE MET. | | C) SHOW ON THE PLANS THE DIMENSIONS OF THE MOUNTING | | HEIGHTS FOR THE GRAB BAR BACKING. PER FHA REQUIREMENT 6 | | D) INDICATE ON THE PLAN WHICH DESIGN SPEC WILL BE USED | | FOR THE BATHROOMS. PER FHA REQUIREMENT 7 | | E) SHOW ON THE PLAN THE CLEAR FLOOR SPACE REQUIRED AT | | THE FIXTURES IN THE BATHROOMS AND KITCHEN. PER FHA | | REQUIREMENT 7 | | F) SHOW ON THE PLANS THE DIMENSIONS FOR THE HEIGHT AND | | DEPTH OF THE VANITY OR WING WALL ADJACENT TO THE WATER | | CLOSET. PER FHA REQUIREMENT 7 | | | | 2. PLEASE INDICATE ON THE PLAN FOR FOUNDATION ONLY. PER | | WPB AMEND TO FBC 107.2.1 | | | | 3. SHT. A701 SHOW THE SQFT AT EACH ROOF DRAIN. PER WPB | | AMEND TO FBC 107.2.1 AND FBC PL CH 11 | | | | 4. ON SHT. P-1 AND P-5 IT SHOWS 685 SQFT ON 3 OF THE | | ROOF DRAINS ON SHT A701 IT SHOWS THOSE SAME ROOF AREAS | | AS 3 DIFFERENT SIZES PLEASE CLARIFY. PER WPB AMEND TO | | FBC 107.2.1 | | | | 5. SHT. P-1 PLEASE PLACE NOTE ON PLAN A SEPARATE PERMIT | | IS REQUIRED FOR BACKFLOW DEVICES. PER WPB UTILITIES | | DEPARTMENT | | | | 6. SHT. P-6 SHOW SIZE ON THE BRANCH'S ON WATER MAIN | | RISER. PER WPB AMEND TO FBC 107.2.1 | | | | 7.SHT. P-1 SHOWS THE HOT AND COLD WATER PIPING TO THE | | WATER HEATER ON THE GROUND FLOOR AS 1/2" THE ISOMETRIC | | SHOWS IT AT 3/4" PLEASE CLARIFY. PER WPB AMEND TO FBC | | 107.2.1 | | | | 8. PLEASE LABEL ALL ALL WASTE AND SOIL STACKS ON | | ISOMETRICS , RISERS AND FLOOR PLANS. PER WPB AMEND TO | | FBC 107.2.1 | | | | 9. SHT. P-7 SHOW BRANCH'S AND SIZE OF BRANCH ON THE | | RISERS. PER WPB AMEND TO FBC 107.2.1 | | | | 10. SHT. P-8 SHOWS 2 ROUND ROOF DRAINS FOR OBSERVATION | | DECK SHT. A701 SHOWS 3 LINEAR FLOOR DRAINS ON THE | | OBSERVATION DECK PLEASE CLARIFY. PER WPB AMEND TO FBC | | 107.2.1 | | | | 11. LABEL STORM RISER TO MATCH THE FLOOR PLAN. PER WPB | | AMEND TO FBC 107.2.1 | | | | 12. PLEASE SHOW PUMP AND DRAIN PIPING FOR ELEVATOR | | SUMP. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
2 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2018-03-23 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2018-03-23 |
Time |
11:00 |
Sent To |
|
|
Notes |
2018-03-23 11:02:34 | NUTTING ENGINEERS HAVE BEEN APPROVED WITH 18030237 AND | | WILL BE THE THRESHOLD INSPECTION COMPANY ON THE ENTIRE | | PROJECT. THRESHOLD/SI AGREEMENT PROVIDED TO KEN CONRAD | | AND RICHARD GATHRIGHT. |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2017-12-04 |
|
|
Cont ID |
|
Sent By |
aclange |
Date |
2017-12-04 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
aclange |
Date |
2017-12-04 |
Time |
13:58 |
Sent To |
|
|
Notes |
2017-12-04 14:00:42 | ART LANGE BUILDING PLANS EXAMINER | | 561-805-6667 [email protected] | | | | | | SEE BUILDING REVIEW FOR THRESHOLD COMMENTS. | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2018-12-05 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2018-12-05 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2018-12-05 |
Time |
|
Sent To |
B |
|
Notes |
2018-12-05 11:33:24 | * FOUNDATION PERMIT ONLY. | | * REFERENCE: FSPR 16-03A. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2018-10-24 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2018-10-24 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2018-10-24 |
Time |
|
Sent To |
B |
|
Notes |
2018-10-24 10:20:19 | REFERENCE: FSPR 16-03A | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2018-05-31 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2018-05-31 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2018-05-31 |
Time |
|
Sent To |
|
|
Notes |
2018-05-31 10:21:37 | ** FAILED ** | | | | REQUIRES A MINOR AMENDMENT TO THE APPROVED SITE PLAN. | | (NOTE: APPLICATION FOR A SITE PLAN AMENDMENT RECEIVED | | BY THE PLANNING DIVISION; SCHEDULED FOR THE 6/13 PPRC | | MEETING.). | | | | CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2018-04-18 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2018-04-18 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2018-04-18 |
Time |
|
Sent To |
|
|
Notes |
2018-04-18 15:49:22 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) THE PERMIT DESCRIPTION SPECIFIES THAT THE PROPOSED | | SCOPE OF WORK IS FOR THE BUILDING FOUNDATION ONLY; | | HOWEVER, ARCHITECTURAL, ELECTRICAL, PLUMBING PLANS, | | ETC., HAVE BEEN INCLUDED IN THE PERMIT SET. ONLY THE | | PLANS THAT ARE PERTINENT TO THE SCOPE OF WORK SHOULD BE | | INCLUDED IN THE PERMIT SET TO AVOID CONFUSION. | | [12/29/17 COMMENT NOT ADDRESSED] | | | | 2.) CHANGES DETECTED IN THE PERMIT PLANS THAT DO NOT | | MATCH THE APPROVED SITE PLAN WHICH MAY IMPACT THE | | FOOTPRINT OF THE FOUNDATION. PLEASE NOTE THAT AN | | AMENDMENT TO THE APPROVED SITE PLAN MUST BE APPROVED BY | | THE PLANNING DIVISION PRIOR TO THE APPROVAL OF THIS | | PERMIT. | | | | | | NOTES: | | | | * REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | * THE PLANS (I.E. SETBACKS AND ELEVATIONS) DO NOT MATCH | | THE APPROVED PLANS FOR THE PROJECT (REFERENCE: FSPR | | 16-03). PLEASE NOTE THAT AN AMENDMENT TO THE APPROVED | | PLANS WILL BE REQUIRED IF THE PLANS (I.E. SITE PLAN, | | ARCHITECTURAL PLANS, ETC.) DO NOT MATCH WHAT HAS BEEN | | APPROVED BY STAFF. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: MF32 | | | | * REFERENCE: FSPR 16-03 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-12-29 |
|
|
Cont ID |
|
Sent By |
LL |
Date |
2017-12-29 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2017-12-21 |
Time |
10:01 |
Sent To |
|
|
Notes |
2017-12-29 12:01:09 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) THE PERMIT DESCRIPTION SPECIFIES THAT THE PROPOSED | | SCOPE OF WORK IS FOR THE BUILDING FOUNDATION ONLY; | | HOWEVER, ARCHITECTURAL, ELECTRICAL, PLUMBING PLANS, | | ETC., HAVE BEEN INCLUDED IN THE PERMIT SET. ONLY THE | | PLANS THAT ARE PERTINENT TO THE SCOPE OF WORK SHOULD BE | | INCLUDED IN THE PERMIT SET TO AVOID CONFUSION. | | | | 2.) PROVIDE THE DIMENSION TO THE OVERALL HEIGHT OF THE | | BUILDING (TO THE HIGHEST POINT). THE HEIGHT OF THE | | BUILDING IS CONTINGENT ON THE SETBACKS OF THE BUILDING. | | | | 3.) THE PLANS (I.E. SETBACKS AND ELEVATIONS) DO NOT | | MATCH THE APPROVED PLANS FOR THE PROJECT (REFERENCE: | | FSPR 16-03). PLEASE NOTE THAT AN AMENDMENT TO THE | | APPROVED PLANS WILL BE REQUIRED IF THE PLANS (I.E. SITE | | PLAN, ARCHITECTURAL PLANS, ETC.) DO NOT MATCH WHAT HAS | | BEEN APPROVED BY STAFF. | | | | | | NOTES: | | | | * REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: MF32 | | | | * REFERENCE: FSPR 16-03 | | |
|
|
|