Plan Review Details - Permit 17111099
Plan Review Stops For Permit 17111099
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-03-16 Cont ID  
Sent By jgomez Date 2018-03-16 Time 08:46 Rev Time 0.00
Received By jgomez Date 2018-03-16 Time 08:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-03-09 Cont ID  
Sent By jgomez Date 2018-03-09 Time 09:41 Rev Time 0.00
Received By jgomez Date 2018-03-09 Time 08:19 Sent To  
Notes
2018-03-09 08:24:18BUILDING REVIEW APPROVED WITH PROVISO:
  
 1-PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC.
 R401.3 FBC-RESIDENTIAL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-12-28 Cont ID  
Sent By jgomez Date 2017-12-28 Time 16:39 Rev Time 0.00
Received By jgomez Date 2017-12-28 Time 09:46 Sent To  
Notes
2017-12-28 12:21:25NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS THAT CONTRACTOR WILL SUBMIT REQUIRED INFORMATION
 AFTER THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO
 AVOID CONFLICTS/DELAYS. REVISION FEES MAY APPLY.
 CONTRACTOR TO ADVICE IF PROVISO OPTION IS PREFERRED AT
 THIS TIME OR IF RE-SUBMITTING REQUIRED INFORMATION.
  
 1- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
  
 2- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC.
 R401.3 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 3- SPECIFY SELF CLOSING DEVICE FOR THE GARAGE DOOR
 LEADING TO THE MAIN HOUSE AS REQUIRED BY SEC. R302.5.1
 FBC-RESIDENTIAL.
  
 4- DESIGN LOADS SPECIFIED UNDER GENERAL CONSTRUCTION
 NOTES ON SHEET A-1 DON'T MATCH DESIGN LOADS SPECIFIED
 ON THE ROOF FRAMING NOTES AND TRUSS DESIGN CRITERIA ON
 SHEET S-3. REVISE AS REQUIRED TO MATCH. NOTE: ALL THE
 DESIGN LOADS SPECIFIED ON THE 3 PLACES NEED TO MATCH
 ALSO. INCLUDE THE STORAGE LOADS AT THE GARAGE ATTIC.
 SEC. R301.1 FBC-RESIDENTIAL AND TABLE R301.5
 FBC-RESIDENTIAL.
  
 5- SPECIFY ON PLANS CARBON MONOXIDE ALARMS BY ALL
 BEDROOMS IN THE LOCATIONS REQUIRED BY SEC. R315.1
 FBC-RESIDENTIAL.
  
 6- FLOOR PLAN ON SHEET A-1 CALLS FOR BEDROOM #4 ON THE
 TOP LEFT CORNER OF THE DRAWING. CLARIFY WHERE IS
 BEDROOM #3?. SEC. 107.2.1 CITY AMENDMENTS. NOTE: NUMBER
 OF BEDROOMS NEEDS TO BE CORRECT SO ENERGY CALCULATIONS
 ARE DONE CORRECTLY ALSO.
  
 7- SIZE OF FOOTING SPECIFIED ON FOUNDATION PLANS ON
 SHEET S-1 DOESN'T MATCH SIZE SHOWN ON WALL SECTION
 1/S-4. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 8- WINDOW NOTE # 3 ON SHEET S-2: CLARIFY WHERE ARE THE
 SHIM SPECIFICATIONS TAKEN FROM?. SEE PRODUCT APPROVALS
 FOR LIMITATION ON SHIM. REVISE AS REQUIRED. SEC.
 107.2.1 CITY AMENDMENTS.
  
 9- ENERGY CALCULATIONS SUBMITTED:
 A) NUMBER OF BEDROOMS DON'T MATCH PLANS. NOTE:
 COORDINATE WITH ENGINEER OF RECORD AND REVISE AS
 REQUIRED. COORDINATE WITH ITEM #6 ABOVE. SEC.
 R101.5.1.1.1 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 B) REVISE ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 TO
 MATCH PLANS AND PRODUCT APPROVAL SUBMITTED. SEC.
 R101.5.1.1.1 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 C) PAGE 2 OF 4 SPECIFIES AN ATTIC VENTILATION RATIO OF
 1/300. PLANS DON'T PROVIDE ANY SPECIFICATIONS FOR THE
 1/300 VENT RATIO. TYPICALLY THE VENT RATIO IS 1/150. IF
 USING THE 1/300 VENT RATIO, THEN PLANS WILL NEED TO BE
 REVISED SHOWING COMPLIANCE WITH THIS RATIO AS REQUIRED
 BY THE EXCEPTION OF SEC. R806.2 FBC-RESIDENTIAL.
 COORDINATE WITH ENGINEER OF RECORD AND REVISE AS
 REQUIRED.
  
 D) WALLS AND WINDOWS ORIENTATION NEED TO BE REVISED TO
 MATCH PLANS. NOTE: SEE SURVEY AND SITE PLAN FOR THE
 CORRECT ORIENTATION. SEC. R101.5.1.1.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 E) COOLING AND HEATING INFORMATION DOESN'T MATCH
 EQUIPMENT SIZING CALCULATIONS. REVISE AS REQUIRED TO
 MATCH. SEC. R101.5.1.1.1 FBC-ENERGY CONSERVATION, 5TH
 EDITION (2014).
  
  
 NOTE:
 LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR AND
 SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WHEN
 THE CALCULATIONS DON'T USE THE PROGRAM'S DEFAULT
 FACTOR.
  
 10- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR THE PRECAST LINTELS AS SPECIFIED ON
 PLANS.
  
 11- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1
 CITY AMENDMENTS.
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWINGS. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-03-01 Cont ID  
Sent By jpearson Date 2018-03-01 Time 10:03 Rev Time 0.00
Received By jpearson Date 2018-03-01 Time 08:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-12-21 Cont ID  
Sent By jpearson Date 2017-12-21 Time 11:23 Rev Time 0.00
Received By jpearson Date 2017-12-21 Time 11:23 Sent To  
Notes
2017-12-21 11:23:26CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE.
 FBC EC R404.1
 2. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF
 EACH ROOM USED FOR SLEEPING PURPOSES. FBC R315.1
 3. NOTE 19 STATES THAT RECEPTACLES SHALL BE TAMPER
 RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT
 APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE
 CORRECTION. NEC 406.12; FBC RE4002.14
 4. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLES IN
 GARAGE, INCLUDING THE GARAGE DOOR OPENER RECEPTACLE.
 NEC 210.8; FBC RE3902.2
 5. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLES IN
 KITCHEN, INCLUDING THE KITCHEN ISLAND RECEPTACLE. NEC
 210.8; FBC RE3902.6
 6. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. NEC 250.94; FBC RE3609.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2017-12-29 Cont ID  
Sent By jgomez Date 2017-12-29 Time 09:15 Rev Time 0.00
Received By jgomez Date 2017-12-29 Time 09:15 Sent To  
Notes
2017-12-29 09:15:56PROVIDE COMPLETE INFORMATION FOR ANY GAS WORK UNDER A
 SEPARATE PERMIT APPLICATION.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-03-16 Cont ID  
Sent By jgomez Date 2018-03-16 Time 08:46 Rev Time 0.00
Received By jgomez Date 2018-03-14 Time 13:15 Sent To I
Notes
2018-03-15 13:16:00RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-03-09 Cont ID  
Sent By jgomez Date 2018-03-09 Time 10:58 Rev Time 0.00
Received By jgomez Date 2018-02-08 Time 15:20 Sent To I
Notes
2018-02-09 15:20:52R29

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-01-08 Cont ID  
Sent By cpuell Date 2018-01-08 Time 11:30 Rev Time 0.00
Received By cpuell Date 2017-11-29 Time 15:09 Sent To  
Notes
2017-11-30 15:09:17R15

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2018-03-16 Cont ID  
Sent By jgomez Date 2018-03-16 Time 08:32 Rev Time 0.00
Received By jgomez Date 2018-03-16 Time 08:30 Sent To  
Notes
2018-03-16 08:35:12$180.62 PAID. MU-2018-008372.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2018-03-09 Cont ID  
Sent By jgomez Date 2018-03-09 Time 08:39 Rev Time 0.00
Received By jgomez Date 2018-03-09 Time 08:38 Sent To  
Notes
2018-03-09 08:40:16BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-12-28 Cont ID  
Sent By jgomez Date 2017-12-28 Time 14:53 Rev Time 0.00
Received By jgomez Date 2017-12-28 Time 14:53 Sent To  
Notes
2017-12-28 14:53:271- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-03-09 Cont ID  
Sent By jgomez Date 2018-03-09 Time 10:32 Rev Time 0.00
Received By jgomez Date 2018-03-09 Time 10:32 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-12-28 Cont ID  
Sent By jgomez Date 2017-12-28 Time 18:23 Rev Time 0.00
Received By jgomez Date 2017-12-28 Time 17:17 Sent To  
Notes
2017-12-28 18:01:17NEW SINGLE FAMILY RESIDENCE (R3), MECHANICAL REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE:
 MECHANICAL REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS THAT CONTRACTOR WILL SUBMIT REQUIRED INFORMATION
 AFTER THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO
 AVOID CONFLICTS/DELAYS. REVISION FEES MAY APPLY.
 CONTRACTOR TO ADVICE IS PROVISO OPTION IS PREFERRED AT
 THIS TIME OR IF RE-SUBMITTING REQUIRED INFORMATION.
  
 1- REVISE EQUIPMENT SIZING CALCULATIONS:
 A) CALCULATIONS NEED TO BE DONE FOR THE ACTUAL
 ORIENTATION OF THE BUILDING AS REQUIRED BY SEC.
 R403.6.1 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
 REVISE AS REQUIRED. NOTE: IT LOOKS LIKE THE PERSON
 PREPARING THE EQUIPMENTS SIZING CALCULATIONS IS THE
 SAME PERSON WHO PREPARED THE ENERGY CALCULATIONS.
 COORDINATE WITH BUILDING COMMENTS REGARDING THE ENERGY
 CALCULATIONS. SEE COMMENTS BELOW.
  
 B) EQUIPMENT LISTED IN THE EQUIPMENT SIZING
 CALCULATIONS AND A/C PLAN SUBMITTED DON'T MATCH. REVISE
 AS REQUIRED TO MATCH. NOTE: COORDINATE WITH A/C
 CONTRACTOR TO AVOID CONFLICTS/DELAYS. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 C) THE COOLING DESIGN CONDITIONS NEED TO BE REVISED AS
 REQUIRED BY SEC. C302.1 FBC-ENERGY CONSERVATION. THE
 MINIMUM DESIGN CONDITIONS FOR COOLING IS 75 DEGREES NOT
 74 DEGREES. REVISE AS REQUIRED.
  
 D) THE NUMBER OF PEOPLE USED FOR THE CALCULATIONS
 DOESN'T MATCH THE NUMBER OF PEOPLE SPECIFIED ON THE
 ENERGY CALCULATIONS. REVISE AS REQUIRED TO MATCH. SEC.
 R403.6.1 FBC-ENERGY CONSERVATION DOESN'T ALLOW ANY
 FACTORS THAT WILL AFFECT THE SIZING OF THE EQUIPMENT.
  
 2- THERE ARE TWO DIFFERENT A/C PLANS SUBMITTED. ONE
 PLAN WAS SUBMITTED WITH THE EQUIPMENT SIZING
 CALCULATIONS AND THE ONE WAS SUBMITTED BY THE A/C
 CONTRACTOR. THEY DON'T MATCH. SUBMIT ONLY ONE A./C PLAN
 TO AVOID CONFLICTS/DELAYS. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 3- A/C PLAN SUBMITTED BY A/C CONTRACTOR (SMYTH AIR
 CONDITIONING INC):
 A) PROVIDE THE NAME AND SIGNATURE OF THE A/C CONTRACTOR
 RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. 107.2.1
 CITY AMENDMENTS.
  
 B) EQUIPMENT LISTED IN THE EQUIPMENT SIZING
 CALCULATIONS AND A/C PLAN SUBMITTED DON'T MATCH. REVISE
 AS REQUIRED TO MATCH. 107.2.1 CITY AMENDMENTS.
  
  
  
 ENERGY CALCULATIONS COMMENTS DONE UNDER THE BUILDING
 REVIEW:
 1- ENERGY CALCULATIONS SUBMITTED:
 A) NUMBER OF BEDROOMS DON'T MATCH PLANS. NOTE:
 COORDINATE WITH ENGINEER OF RECORD AND REVISE AS
 REQUIRED. COORDINATE WITH ITEM #6 ABOVE. SEC.
 R101.5.1.1.1 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 B) REVISE ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 TO
 MATCH PLANS AND PRODUCT APPROVAL SUBMITTED. SEC.
 R101.5.1.1.1 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 C) PAGE 2 OF 4 SPECIFIES AN ATTIC VENTILATION RATIO OF
 1/300. PLANS DON'T PROVIDE ANY SPECIFICATIONS FOR THE
 1/300 VENT RATIO. TYPICALLY THE VENT RATIO IS 1/150. IF
 USING THE 1/300 VENT RATIO, THEN PLANS WILL NEED TO BE
 REVISED SHOWING COMPLIANCE WITH THIS RATIO AS REQUIRED
 BY THE EXCEPTION OF SEC. R806.2 FBC-RESIDENTIAL.
 COORDINATE WITH ENGINEER OF RECORD AND REVISE AS
 REQUIRED.
  
 D) WALLS AND WINDOWS ORIENTATION NEED TO BE REVISED TO
 MATCH PLANS. NOTE: SEE SURVEY AND SITE PLAN FOR THE
 CORRECT ORIENTATION. SEC. R101.5.1.1.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 E) COOLING AND HEATING INFORMATION DOESN'T MATCH
 EQUIPMENT SIZING CALCULATIONS. REVISE AS REQUIRED TO
 MATCH. SEC. R101.5.1.1.1 FBC-ENERGY CONSERVATION, 5TH
 EDITION (2014).
  
  
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWINGS. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-03-09 Cont ID  
Sent By jgomez Date 2018-03-09 Time 11:12 Rev Time 0.00
Received By jgomez Date 2018-03-09 Time 11:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-12-29 Cont ID  
Sent By jgomez Date 2017-12-29 Time 09:04 Rev Time 0.00
Received By jgomez Date 2017-12-29 Time 09:04 Sent To Z
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2017-12-28 Cont ID  
Sent By jgomez Date 2017-12-28 Time 16:54 Rev Time 0.00
Received By jgomez Date 2017-12-28 Time 16:54 Sent To  
Notes
2017-12-28 17:03:56A)SHINGLES FLORIDA PRODUCT APPROVAL FL18355-R3.
  
 B) UNDERLAYMENT FLORIDA PRODUCT APPROVAL FL17322-R2.

Review Stop Z ZONING
Rev No 2 Status P Date 2018-03-02 Cont ID  
Sent By AW Date 2018-03-02 Time   Rev Time 0.00
Received By awooten Date 2018-03-02 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By AW Date 2018-01-08 Time   Rev Time  
Received By   Date   Time   Sent To M
Notes
2018-01-08 11:11:34*************************ZONING REVIEW
 FAILED****************************
  
 THE FOLLOWING ARE LANDSCAPE REQUIREMENTS FOR NEW
 RESIDENTIAL DEVELOPMENT:
  
 LANDSCAPING:
 GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY
 DWELLING UNITS SHALL BE AS FOLLOWS:
 A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT
 TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF
 OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR
 EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.
 B. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PLAN WITH TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 THERE IS ANOTHER OPTION OF SUBMITTING A CONDITIONAL
 LANDSCAPE APPROVAL APPLICATION, SO THAT THIS PERMIT CAN
 BE APPROVED. HOWEVER, PRIOR TO ISSUANCE OF CO A
 LANDSCAPE PLAN MUST BE SUMBITTED AND FINAL LANDSCAPE
 INSPECTION MUST BE PASSED. PLEASE CONTACT ME FOR MORE
 INFORMATION ON THE CONDITIONAL LANDSCAPE APPROVAL
 APPLICATION.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]
  
  