Plan Review Details - Permit 17110988
Plan Review Stops For Permit 17110988
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-01-06 Cont ID  
Sent By cthroop Date 2018-01-06 Time 11:06 Rev Time 0.00
Received By cthroop Date 2018-01-06 Time 11:02 Sent To E
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-12-11 Cont ID  
Sent By cthroop Date 2017-12-11 Time 16:09 Rev Time 0.00
Received By cthroop Date 2017-12-11 Time 16:08 Sent To E
Notes
2017-12-11 16:10:25BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROPOSED SIGN IS PROHIBITED BY ZONING.
 2. NO BUILDING REVIEW PERFORMED AT THIS TIME.
 3. ADDRESS ZONING COMMENTS AND RE-SUBMIT.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-01-08 Cont ID  
Sent By jleahy Date 2018-01-08 Time 10:52 Rev Time 0.00
Received By jleahy Date 2018-01-08 Time 10:52 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-12-11 Cont ID  
Sent By jleahy Date 2017-12-11 Time 17:01 Rev Time 0.00
Received By jleahy Date 2017-12-11 Time 17:00 Sent To I
Notes
2017-12-11 17:03:54FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PROVIDE DISCONNECT SWITCH AT SIGN LOCATION. NEC 600.6
  
 PROVIDE DEDICATED CIRCUIT AND CONTROL FOR SIGN. NEC
 600.5; FBC CE 405.2.4
  
 EACH SIGN AND OUTLINE LIGHTING SYSTEM, OR FEEDER
 CIRCUIT OR BRANCH CIRCUIT SUPPLYING A
 SIGN OR OUT-LINE LIGHTING SYSTEM, SHALL BE CONTROLLED
 BY AN EXTERNALLY OPERABLE SWITCH
 OR CIRCUIT BREAKER THAT WILL OPEN ALL UNGROUNDED
 CONDUCTORS WITHIN SIGHT OF THE SIGN
 NEC 600.6(A)(1)
  
 ALL EXTERIOR LIGHTING NOT EXEMPTED BY FBC 405.1 SHALL
 HAVE AUTOMATIC CONTROLS TO
 TURN OFF AT DAYLIGHT OR WHEN NOT REQUIRED. CONTROLS
 SHALL BE PHOTOSENSOR & TIME CLOCK
 OR ASTRONOMICAL TIME SWITCH. ALL TIME SWITCHES SHALL BE
 CAPABLE OF RETAINING PROGRAMING
 DURING A LOSS OF POWER FOR A MINIMUM OF 10 HOURS.
 FBC-EC 405.2.4
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-01-08 Cont ID  
Sent By jleahy Date 2018-01-08 Time 10:52 Rev Time 0.00
Received By jleahy Date 2017-12-18 Time 13:49 Sent To  
Notes
2018-01-04 10:51:01TO MISC 2 BOX
2017-12-19 13:49:47RESUB ROUTED TO AAPONTE VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-11 Cont ID  
Sent By jleahy Date 2017-12-11 Time 17:04 Rev Time 0.00
Received By jleahy Date 2017-11-27 Time 14:16 Sent To  
Notes
2017-12-07 16:15:27MISC 2 BOX.
2017-11-28 14:17:06ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2018-01-04 Cont ID  
Sent By AA Date 2018-01-04 Time 10:50 Rev Time 0.00
Received By aaponte Date 2017-12-21 Time 10:36 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-12-07 Cont ID  
Sent By AA Date 2017-12-07 Time 16:13 Rev Time 0.00
Received By aaponte Date 2017-11-30 Time 14:46 Sent To  
Notes
2017-12-07 16:15:111. INTERNALLY ILLUMINATED BOX SIGN ARE NOT PERMITTED
 (SEC 94-110 (B)(3).
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.