Plan Review Stops For Permit 17110725 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-01-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-30 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-30 |
Time |
16:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-01-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-25 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-25 |
Time |
08:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-12-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-21 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-12-20 |
Time |
14:27 |
Sent To |
|
|
Notes |
2017-12-21 16:13:49 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING PERMIT REQUIRED. | | 2. SEE PAGE A-1, GENERAL NOTES. REMOVE REFERENCE TO | | 2010 FBC. | | 3. SEE PAGE S-1, SECTION 1, VERTICAL DOWELS IN | | RE-INFORCED MASONRY WALLS SHALL BE TERMINATED IN BOND | | BEAM. | | 4. PROVIDE WINDOW AND DOOR SCHEDULE. IDENTIFY WHICH | | PRODUCTS GO WHERE ON PLAN. DESIGN WIND LOADS OK. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-01-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-01-18 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-01-18 |
Time |
15:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-12-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-12-08 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-12-08 |
Time |
16:46 |
Sent To |
|
|
Notes |
2017-12-08 16:51:38 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PROVIDE SMOKE ALARM ON EACH STORY OF THE DWELLING. FBC | | R314. | | | | SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN | | 6 FEET FROM A RECEPTACLE OUTLET. PROVIDE CORRECTION. | | NEC 210.52; FBC RE3901.2.1 | | THIS IS FOR THE SECOND FLOOR BEDROOM | | | | PROVIDE GFCI PROTECTION FOR ALL OUTLETS IN GARAGE. NEC | | 210.8; FBC RE3902.2 | | PATIO TV OUTLET | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-01-30 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-30 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-08 |
Time |
15:49 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-12-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-21 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-11-16 |
Time |
13:59 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-01-25 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2018-01-25 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2018-01-25 |
Time |
14:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-12-13 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-12-13 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-12-13 |
Time |
09:10 |
Sent To |
|
|
Notes |
2017-12-13 09:28:25 | NO PLAN SUBMITTED FOR AIR CONDITIONING. HM. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-01-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-01-24 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-01-24 |
Time |
07:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-12-01 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-12-01 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-12-01 |
Time |
13:39 |
Sent To |
|
|
Notes |
2017-12-01 13:48:03 | SUBMIT A SANITARY RISER THAT CLEARLY REFLECTS THE SCOPE | | OF WORK BEING DONE TO THE 2ND FLOOR MASTER BATH | | PLUMBING. THE SUBMITTED SANITARY RISER DOES NOT SHOW | | THIS. WPB AMEND. TO FBC SEC. 107.3.5.3. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-01-30 |
|
|
Cont ID |
|
Sent By |
LL |
Date |
2018-01-30 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2018-01-29 |
Time |
|
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-11-29 |
|
|
Cont ID |
|
Sent By |
LL |
Date |
2017-11-29 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2017-11-29 |
Time |
|
Sent To |
|
|
Notes |
2017-11-29 11:27:25 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) UPDATED SIGNED AND SEALED SURVEY REQUIRED. | | | | 2.) THE VALUE OF THE CONSTRUCTION ($200,000) EXCEEDS | | 50% OF THE STRUCTURE'S VALUE ($389,514) ACCORDING TO | | THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, | | PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. | | | | | | NOTES: | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: SF7 | | |
|
|