Plan Review Details - Permit 17110725
Plan Review Stops For Permit 17110725
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-01-30 Cont ID  
Sent By cthroop Date 2018-01-30 Time 16:17 Rev Time 0.00
Received By cthroop Date 2018-01-30 Time 16:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-01-25 Cont ID  
Sent By cthroop Date 2018-01-25 Time 13:44 Rev Time 0.00
Received By cthroop Date 2018-01-25 Time 08:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-12-21 Cont ID  
Sent By cthroop Date 2017-12-21 Time 16:08 Rev Time 0.00
Received By cthroop Date 2017-12-20 Time 14:27 Sent To  
Notes
2017-12-21 16:13:49BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED.
 2. SEE PAGE A-1, GENERAL NOTES. REMOVE REFERENCE TO
 2010 FBC.
 3. SEE PAGE S-1, SECTION 1, VERTICAL DOWELS IN
 RE-INFORCED MASONRY WALLS SHALL BE TERMINATED IN BOND
 BEAM.
 4. PROVIDE WINDOW AND DOOR SCHEDULE. IDENTIFY WHICH
 PRODUCTS GO WHERE ON PLAN. DESIGN WIND LOADS OK.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-01-18 Cont ID  
Sent By jleahy Date 2018-01-18 Time 15:11 Rev Time 0.00
Received By jleahy Date 2018-01-18 Time 15:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-12-08 Cont ID  
Sent By jleahy Date 2017-12-08 Time 16:46 Rev Time 0.00
Received By jleahy Date 2017-12-08 Time 16:46 Sent To  
Notes
2017-12-08 16:51:38FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PROVIDE SMOKE ALARM ON EACH STORY OF THE DWELLING. FBC
 R314.
  
 SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING
 REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE
 INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG
 THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN
 6 FEET FROM A RECEPTACLE OUTLET. PROVIDE CORRECTION.
 NEC 210.52; FBC RE3901.2.1
 THIS IS FOR THE SECOND FLOOR BEDROOM
  
 PROVIDE GFCI PROTECTION FOR ALL OUTLETS IN GARAGE. NEC
 210.8; FBC RE3902.2
 PATIO TV OUTLET
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-01-30 Cont ID  
Sent By cthroop Date 2018-01-30 Time 16:17 Rev Time 0.00
Received By cthroop Date 2018-01-08 Time 15:49 Sent To I
Notes
2018-01-09 15:52:12R19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-21 Cont ID  
Sent By cthroop Date 2017-12-21 Time 16:13 Rev Time 0.00
Received By cthroop Date 2017-11-16 Time 13:59 Sent To I
Notes
2017-11-20 13:59:09R03

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-01-25 Cont ID  
Sent By hmoser Date 2018-01-25 Time 14:42 Rev Time 0.00
Received By hmoser Date 2018-01-25 Time 14:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-12-13 Cont ID  
Sent By hmoser Date 2017-12-13 Time 09:26 Rev Time 0.00
Received By hmoser Date 2017-12-13 Time 09:10 Sent To  
Notes
2017-12-13 09:28:25NO PLAN SUBMITTED FOR AIR CONDITIONING. HM.

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-01-24 Cont ID  
Sent By gjohnson Date 2018-01-24 Time 08:17 Rev Time 0.00
Received By gjohnson Date 2018-01-24 Time 07:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-12-01 Cont ID  
Sent By tklarge Date 2017-12-01 Time 13:48 Rev Time 0.00
Received By tklarge Date 2017-12-01 Time 13:39 Sent To  
Notes
2017-12-01 13:48:03SUBMIT A SANITARY RISER THAT CLEARLY REFLECTS THE SCOPE
 OF WORK BEING DONE TO THE 2ND FLOOR MASTER BATH
 PLUMBING. THE SUBMITTED SANITARY RISER DOES NOT SHOW
 THIS. WPB AMEND. TO FBC SEC. 107.3.5.3.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-01-30 Cont ID  
Sent By LL Date 2018-01-30 Time   Rev Time 0.00
Received By llouie Date 2018-01-29 Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-11-29 Cont ID  
Sent By LL Date 2017-11-29 Time   Rev Time  
Received By llouie Date 2017-11-29 Time   Sent To  
Notes
2017-11-29 11:27:25** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) UPDATED SIGNED AND SEALED SURVEY REQUIRED.
  
 2.) THE VALUE OF THE CONSTRUCTION ($200,000) EXCEEDS
 50% OF THE STRUCTURE'S VALUE ($389,514) ACCORDING TO
 THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE,
 PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE
 SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE
 SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A
 LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE
 INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES
 NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING
 APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL
 TO BRING THE SITE INTO CONFORMITY.
  
  
 NOTES:
  
 * REVISION MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: SF7
  