Plan Review Details - Permit 17110715
Plan Review Stops For Permit 17110715 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-02-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-02-26 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-02-26 |
Time |
16:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-12-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-06 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-12-06 |
Time |
08:15 |
Sent To |
|
|
Notes |
2017-12-06 08:26:04 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | A STRUCTURAL ANALYSIS SHALL BE PERFORMED BY THE OWNER?S | | AGENT TO CERTIFY THAT THE EXISTING/PROPOSED | | COMMUNICATION STRUCTURE AND COMPONENTS ARE STRUCTURALLY | | ADEQUATE TO SUPPORT ALL EXISTING AND PROPOSED ANTENNAS, | | COAXIAL CABLES AND OTHER APPURTENANCES. THE OWNER?S | | AGENT SHALL FURNISH A CERTIFICATION LETTER SEALED BY A | | REGISTERED PROFESSIONAL ENGINEER STATING THAT THIS | | STRUCTURAL ANALYSIS WAS PREPARED IN ACCORDANCE WITH ALL | | APPLICABLE CODES AND STANDARDS. | | | | PROVIDE AN ATTACHMENT DETAIL FOR ALL PROPOSED ANTENNAS | | AND DEVICES. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-02-26 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-02-26 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-02-26 |
Time |
13:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-12-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-12-04 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-12-04 |
Time |
11:02 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-02-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-02-26 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-02-08 |
Time |
13:27 |
Sent To |
I |
|
Notes |
2018-02-09 13:27:59 | RESUB ROUTED TO JROACH VIA ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-12-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-06 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-11-16 |
Time |
11:21 |
Sent To |
I |
|
Notes |
2017-11-20 11:21:17 | ROUTED TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-02-22 |
|
|
Cont ID |
|
Sent By |
JR |
Date |
2018-02-22 |
Time |
13:38 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2018-02-13 |
Time |
12:03 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-11-22 |
|
|
Cont ID |
|
Sent By |
JR |
Date |
2017-11-22 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2017-11-22 |
Time |
16:49 |
Sent To |
E |
|
Notes |
2017-11-22 16:49:31 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 11.22.2017 | | PERMIT NO.: 17110715 | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | WIRELESS COMMUNICATIONS ANTENNAS AND EQUIPMENT, A | | WIRELESS COMMUNICATION FACILITY DEVELOPMENT APPLICATION | | SHALL BE SUBMITTED TO THE DEVELOPMENT SERVICES | | DEPARTMENT ? PLANNING DIVISION. SUCH APPLICATION WILL | | BE REVIEWED BY THE CITY AND CITYSCAPE CONSULTANTS AND | | SHALL BE APPROVED BEFORE ANY PERMIT MAY BE ISSUED. | | PLEASE CONTACT ME (PREFERABLY VIA EMAIL) FOR A COPY OF | | THE APPLICATION. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | F: 561.822.1460 | | | | E: [email protected] | | | | W: WPB.ORG | | | 2017-11-22 12:03:34 | 11/22/17 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |