Plan Review Stops For Permit 17110548 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-01-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-18 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-11 |
Time |
15:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-12-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-13 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-12-12 |
Time |
13:56 |
Sent To |
|
|
Notes |
2017-12-13 15:28:58 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. OWNER/AGENT TO SIGN ENERGY SUBMITTAL FOR MAIN HOUSE. | | 2. REVISIT YOUR WINDOW AND DOOR SCHEDULES AND NOA | | SUBMITTAL PACKAGE. THERE ARE NOA'S MISSING FROM | | SCHEDULES AND NOA'S MISSING FORM SUBMITTAL. I.E. FIXED | | WINDOWS/OHD/ETC. | | 3. PROVIDE PRODUCT APPROVALS FOR PROPOSED SURFACE MOUNT | | WIND ABATEMENT SYSTEM. | | 4. PROVIDE ICC-ES REPORT FOR PROPOSED ICYNENE | | INSULATION. IDENTIFY PRODUCT TO BE INSTALLED BASED ON | | REQUIRED R - VALUE. PRODUCT MANUFACTURERS INSTALLATION | | INSTRUCTIONS TO BE ON-SITE AT TIME OF INSPECTION. | | 5. REF. PLAN PAGE A101 - WIND EXPOSURE AND SURFACE | | ROUGHNESS CATEGORIES SHOULD BE ROUGHNESS B PER FBC | | R301.2.1.4.2 & EXPOSURE B PER R301.2.1.4.3. | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | _ OR _ | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR | | SUBMITTALS. | | | | R301.2.1.4.2 SURFACE ROUGHNESS CATEGORIES. | | A GROUND SURFACE ROUGHNESS WITHIN EACH 45-DEGREE (0.79 | | RAD) SECTOR SHALL BE DETERMINED FOR A DISTANCE UPWIND | | OF THE SITE AS DEFINED IN SECTION R301.2.1.4.3 FROM THE | | CATEGORIES DEFINED BELOW, FOR THE PURPOSE OF ASSIGNING | | AN EXPOSURE CATEGORY AS DEFINED IN SECTION | | R301.2.1.4.3. | | | | SURFACE ROUGHNESS B. URBAN AND SUBURBAN AREAS, WOODED | | AREAS OR OTHER TERRAIN WITH NUMEROUS CLOSELY SPACED | | OBSTRUCTIONS HAVING THE SIZE OF SINGLE-FAMILY DWELLINGS | | OR LARGER | | | | R301.2.1.4.3 EXPOSURE CATEGORIES. | | AN EXPOSURE CATEGORY SHALL BE DETERMINED IN ACCORDANCE | | WITH THE FOLLOWING: | | | | EXPOSURE B. FOR BUILDINGS WITH A MEAN ROOF HEIGHT OF | | LESS THAN OR EQUAL TO 30 FEET (9144 MM), EXPOSURE B | | SHALL APPLY WHERE THE GROUND SURFACE ROUGHNESS, AS | | DEFINED BY SURFACE ROUGHNESS B, PREVAILS IN THE UPWIND | | DIRECTION FOR A DISTANCE OF AT LEAST 1,500 FEET (457 | | M). FOR BUILDINGS WITH A MEAN ROOF HEIGHT GREATER THAN | | 30 FEET (9144 MM), EXPOSURE B SHALL APPLY WHERE SURFACE | | ROUGHNESS B PREVAILS IN THE UPWIND DIRECTION FOR A | | DISTANCE OF AT LEAST 2,600 FEET (792 M) OR 20 TIMES THE | | HEIGHT OF THE BUILDING, WHICHEVER IS GREATER. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-01-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-01-09 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-01-09 |
Time |
10:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-12-08 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-12-08 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-12-08 |
Time |
13:49 |
Sent To |
|
|
Notes |
2017-12-08 13:49:14 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. FEEDER "F-4" SHOWS 2/0 WIRE FEEDING A 200 AMP PANEL, | | PANEL A. THIS IS LABELED AS PANEL B IN THE PANEL | | SCHEDULE FOR PANEL DP AND SHOWS 3/0 WIRE FEEDING THE | | PANEL. CORRECT DISCREPANCY. BE ADVISED THAT 2/0 WIRE IS | | NOT RATED FOR A 200 AMP FEED. TABLE 310.15(B)(7) IS NOT | | PERMITTED TO BE USED UNLESS THE FEEDER IN QUESTION | | CARRIES 100% OF THE LOAD. PROVIDE CORRECTION. NEC | | 310.15(B)(7) AND (B)(15); FBC RE TABLE E3603.1, 3704.1 | | 2. FEEDER FROM METER CAN TO ATS SHOULD NOT INCLUDE AN | | EQUIPMENT GROUNDING CONDUCTOR. PROVIDE CORRECTION. NEC | | 250.6, 250.24 | | 3. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1, | | 107.2.1 | | 4. SHEET E-0, ARC FAULT BREAKER NOTE # 2 REFERENCES NEC | | 406.11, WHICH IS NOT THE CURRENT CODE FOR TAMPER | | RESISTANT RECEPTACLES. THE STATEMENT ALSO LEAVES OUT | | THE REQUIREMENT FOR 15 AMP RECEPTACLES. PROVIDE | | CORRECTION. NEC 406.12; FBC RE4002.14 | | 5. PANEL SCHEDULE FOR PANEL DP SHOWS # 1 WIRE ON A 150 | | AMP BREAKER FOR THE GUEST HOUSE. PROVIDE CORRECTION, | | SAME REASONING AS COMMENT # 1. NEC 310.15(B)(7) AND | | (B)(15); FBC RE TABLE E3603.1, 3704.1 | | 6. SECOND FLOOR PLAN SHOWS A PENDANT LIGHT IN HER | | CLOSET. PER CODE: "LIGHTING WITH OPEN OR PARTIALLY | | ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS | | SHALL NOT BE PERMITTED IN CLOTHES CLOSETS". PROVIDE | | CORRECTION. NEC 410.16; FBC RE4003.12 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2018-01-18 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-01-18 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-01-18 |
Time |
12:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-12-06 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-12-06 |
Time |
06:07 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-12-06 |
Time |
05:42 |
Sent To |
|
|
Notes |
2017-12-06 05:42:51 | 1) THE TANKLESS WATER HEATERS SHALL BE LOCATED A | | MINIMUM OF 4 FEET BELOW OR TO THE SIDE OF A WINDOW OR | | DOOR THAT CAN BE OPENED PER THE MANUFACTURER'S | | INSTALLATION MANUAL. | | 2) SUBMIT 2 COPIES OF THE MANUFACTURER'S SPECIFICATIONS | | FOR ALL GAS EQUIPMENT/APPLIANCES. APPLIANCES SHALL BE | | LISTED AND LABELED. FBC-FUEL GAS SEC.301.3. | | 3) SHT. P-3 - SHOW THE TYPE OF PIPE AND SIZE OF THE | | PIPE FOR THE TANKLESS WATER HEATERS. FBC -FUEL GAS CODE | | TABLE 402.4 (15). | | 4) SHT. P-3 - SHOW THE TYPE OF PIPE AND SIZE FOR THE | | GAS LINE TO THE GENERATOR. | | 5) SHOW THE SIZE AND TYPE OF PIPE ON THE OUTLET SIDE OF | | THE GAS METER. | | 6) THE GAS INSTALLATION SHALL BE DONE UNDER A SEPARATE | | PERMIT. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-01-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-01-24 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-01-24 |
Time |
15:25 |
Sent To |
|
|
Notes |
2018-01-24 15:25:41 | IMPACT FEES ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-01-18 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2018-01-18 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-12-22 |
Time |
16:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-12-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-13 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-11-14 |
Time |
09:39 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2018-01-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-01-24 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-01-24 |
Time |
15:31 |
Sent To |
I |
|
Notes |
2018-01-24 15:31:56 | MU-2018-2460 | | $0 DUE |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-12-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-13 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-12-12 |
Time |
13:56 |
Sent To |
|
|
Notes |
2017-12-13 15:04:43 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-01-18 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-01-18 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-01-18 |
Time |
12:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-12-11 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2017-12-11 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2017-12-11 |
Time |
08:51 |
Sent To |
|
|
Notes |
2017-12-11 11:17:27 | PLAN DENIED | | 1) REFER TO SECTION M1602.2 PROHIBITED SOURCES. | | NOTE # 4 (RETURN AIR IN KITCHEN) 1014 RESIDENTIAL CODE | | 2) REFER TO SECTION M1503.4 MAKEUP AIR. PROVIDE | | MANUFACTURES SPECKS ON RANGE HOOD WITH PLANS | | 2014 RESIDENTIAL CODE | | 3) REFER TO SECTION M1602.4 BALANCED RETURN AIR | | (MASTER BEDROOM) 2014 RESIDENTIAL CODE | | 4) REFER TO SECTION R403.2.4 AIR HANDLER | | UNITS (FOR AIR HANDLERS 3 & 4) | | 2014 FLORIDA ENERGY CODE | | 5) THERE WERE NO AIR CONDITIONING PLAN | | SUBMITTED FOR GUEST HOUSE. | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-01-18 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-01-18 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-01-18 |
Time |
12:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-12-06 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-12-06 |
Time |
05:56 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-12-04 |
Time |
09:33 |
Sent To |
|
|
Notes |
2017-12-05 06:20:34 | 1) SHT. A 102 - SHOW THE WIDTH OF THE SHOWER ON THE 2ND | | FLOOR. THE SHOWER SHALL BE A MINIMUM OF 30 INCHES WIDE | | AND A MINIMUM OF 900 SQUARE INCHES. | | 2) SHT. A 102 - THE WATER VALVES FOR THE STACKABLE | | WASHER SHALL BE ACCESSIBLE. FBC-PLUMBING SEC.606.3. | | 3) SHT. A113 - INDICATE ON THE PLAN THE SLOPE OF THE 6 | | INCH GUTTER. COMPLY WITH FBC-PLUMBING, TABLE 1106.6 FOR | | THE SQUARE FFOOTAGE BEING DRAINED. | | 4) THE TANKLESS WATER HEATERS SHALL BE LOCATED A | | MINIMUM OF 4 FEET BELOW OR TO THE SIDE OF A WINDOW OR | | DOOR THAT CAN BE OPENED PERR THE MANUFACTURER'S | | INSTALLATION MANUAL. | | 5) AN AIR ARRESTOR IS REQD. ON THE WATER SUPPLY TO THE | | ICE MAKER. FBC-PLUMBING SEC. 604.9. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2018-01-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-18 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-11 |
Time |
15:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2017-12-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-13 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-12-12 |
Time |
17:17 |
Sent To |
|
|
Notes |
2017-12-13 15:03:42 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING PERMIT REQUIRED. | | 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING | | SYSTEMS. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
PG |
Date |
2018-01-18 |
Time |
|
Rev Time |
0.00 |
Received By |
pgreilic |
Date |
2018-01-18 |
Time |
15:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
PG |
Date |
2017-11-17 |
Time |
|
Rev Time |
0.00 |
Received By |
pgreilic |
Date |
2017-11-17 |
Time |
13:22 |
Sent To |
|
|
Notes |
|
|