Plan Review Details - Permit 17110405
Plan Review Stops For Permit 17110405 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-01-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-01-11 |
Time |
17:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-01-11 |
Time |
15:16 |
Sent To |
|
|
Notes |
2018-01-11 17:57:56 | APPROVED WITH EXCEPTIONS | | | | 1) THE FIELD INSPECTOR SHALL VERIFY THAT THE | | REPLACEMENT BEDROOM WINDOW PROVIDES FOR AN EQUAL OR | | GREATER OPENING AREA THAN THE EXISTING WINDOW AND | | COMPLIES WITH FBC EXISTING BUILDING SECTION 704. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-12-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-12-15 |
Time |
18:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-12-15 |
Time |
18:47 |
Sent To |
I |
|
Notes |
2017-12-15 18:47:17 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING (PREVIOUS COMMENTS WERE NOT | | ADDRESSED) SUBMIT A NARRATIVE EXPLANING HOW EACH OF THE | | COMMENTS HAS BEEN ADDRESSED. | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC-R310.1 REQUIRES EVERY SLEEPING ROOM TO HAVE AT | | LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. | | IN ORDER TO VERIFY THIS REQUIREMENT, PROVIDE A FLOOR | | PLAN WITH THE ROOMS LABELED. SPECIFY THE TYPE AND SIZE | | OF THE EXISTING WINDOWS ON THE PLANS. IF WINDOWS ARE | | CONNECTED TO EACH OTHER USING MULLIONS SPECIFY THE SIZE | | AND NUMBER OF THE WIDOWS IN THE OPENING. FBC 107.2.1 | | | | 2) A PRODUCT APPROVAL FOR STRUCTURAL MULLIONS WAS | | SUBMITTED. INDICATE THE CONFIGURATION OF THE WINDOWS | | WHERE THIS WILL BE INSTALLED. IN ORDER TO REVIEW THE | | MULLIONS FOR CODE COMPLIANCE THE MULLION SPAN AND | | TRIBUTARY WIDTH ARE REQUIRED.FBC - R301.2.1 | | | | 3) THE PRODUCT CERTIFICATION AND INSTALLATION | | INSTRUCTIONS THAT ARE ATTACHED TO THE HORIZONTAL | | SLIDING WINDOW FL16804 ARE NOT THE ONES FOR THE XO, OX | | CONFIGURATIONS THAT WERE CIRCLED BY YOU ON PAGE 2 OF | | THE PRODUCT APPROVAL. PLEASE CORRECT. FBC 107.2.1 | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-14 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-13 |
Time |
19:01 |
Sent To |
I |
|
Notes |
2017-11-14 08:45:18 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC-R310.1 REQUIRES EVERY SLEEPING ROOM TO HAVE AT | | LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. | | IN ORDER TO VERIFY THIS REQUIREMENT, PROVIDE A FLOOR | | PLAN WITH THE ROOMS LABELED. SPECIFY THE TYPE AND SIZE | | OF THE EXISTING WINDOWS ON THE PLANS. IF WINDOWS ARE | | CONNECTED TO EACH OTHER USING MULLIONS SPECIFY THE SIZE | | AND NUMBER OF THE WIDOWS IN THE OPENING. FBC 107.2.1 | | | | 2) A PRODUCT APPROVAL FOR STRUCTURAL MULLIONS WAS | | SUBMITTED. INDICATE THE CONFIGURATION OF THE WIDOWS | | WEAR THIS WILL BE INSTALLED. IN ORDER TO REVIEW THE | | MULLIONS FOR CODE COMPLIANCE THE MULLION SPAN AND | | TRIBUTARY WIDTH ARE REQUIRED.FBC - R301.2.1 | | | | 3) THE PRODUCT CERTIFICATION AND INSTALLATION | | INSTRUCTIONS THAT ARE ATTACHED TO THE HORIZONTAL | | SLIDING WINDOW FL16804 ARE NOT THE ONES FOR THE XO, OX | | CONFIGURATIONS THAT WERE CIRCLED BY YOU ON PAGE 2 OF | | THE PRODUCT APPROVAL. PLEASE CORRECT. FBC 107.2.1 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-01-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-01-11 |
Time |
17:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-01-09 |
Time |
13:46 |
Sent To |
I |
|
Notes |
2018-01-10 13:46:15 | RESUB ROUTED TO RMCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-12-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-12-15 |
Time |
18:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-12-12 |
Time |
11:44 |
Sent To |
|
|
Notes |
2017-12-13 11:45:13 | RESUB ROUTED TO RMCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-14 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-09 |
Time |
09:32 |
Sent To |
|
|
Notes |
2017-11-13 09:33:07 | BLDG MISC 1 |
|
|
|