Plan Review Details - Permit 17110329
Plan Review Stops For Permit 17110329
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-01-11 Cont ID  
Sent By rmcdouga Date 2018-01-11 Time 19:03 Rev Time 0.00
Received By rmcdouga Date 2018-01-11 Time 19:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-11-09 Cont ID  
Sent By rmcdouga Date 2017-11-09 Time 12:11 Rev Time 0.00
Received By rmcdouga Date 2017-11-09 Time 10:22 Sent To I
Notes
2017-11-09 12:11:33PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SPECIFY THE MEAN ROOF HEIGHT (2 STORY STRUCTURE) AND
 THE ROOF SLOPE OF THE STRUCTURE. FBC 107.2.1,
 FBC-R301.2.1
  
 2) THIS TWO STORY STRUCTURE IS LOCATED IN EXPOSURE
 CATEGORY D WITH A 170 MPH WIND SPEED. THE PRODUCT
 APPROVAL THAT WAS SUBMITTED FOR THE METAL ROOFING HAS A
 MAXIMUM UPLIFT DESIGN PRESSURE OF -71 PSF. THIS UPLIFT
 IS NOT ADEQUATE FOR THE REQUIRED UPLIFT PRESSURES IN
 THE PERIMETER AND CORNER ROOF AREAS. FBC-R301.2.1

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-01-11 Cont ID  
Sent By rmcdouga Date 2018-01-11 Time 19:04 Rev Time 0.00
Received By rmcdouga Date 2018-01-10 Time 09:36 Sent To  
Notes
2018-01-11 09:36:35RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-11-09 Cont ID  
Sent By rmcdouga Date 2017-11-09 Time 12:11 Rev Time 0.00
Received By rmcdouga Date 2017-11-08 Time 14:52 Sent To  
Notes
2017-11-08 14:52:37RMCDOUGAL