Plan Review Details - Permit 17101099
Plan Review Stops For Permit 17101099
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-01-06 Cont ID  
Sent By cthroop Date 2018-01-06 Time 08:41 Rev Time 0.00
Received By cthroop Date 2018-01-05 Time 12:07 Sent To  
Notes
2018-01-06 08:42:27BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SPLIT APPLICATION. CREATE NEW PERMIT FOR SHED.
 2. ENERGY SUBMITTAL TO BE SIGNED BBY OWNER/AGENT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-12-02 Cont ID  
Sent By cthroop Date 2017-12-02 Time 09:52 Rev Time 0.00
Received By cthroop Date 2017-11-28 Time 11:18 Sent To  
Notes
2017-12-02 10:14:43BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PRODUCT APPROVAL AFFIDAVIT LIST'S FLO10456-R3,
 FL10446.8 & FL11473-R3. THESE PRODUCT APPROVALS ARE
 MISSING FROM SUBMITTAL.
 2. ENERGY SUBMITTAL REQUIRES R38 TO BE INSTALLED IN
 ATTIC. PLAN PAGE S2 SHOWS R19. PLEASE CORRECT PLAN
 PAGE.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW, AND DOOR SUBMITTALS.
  
 R402.1 GENERAL (PRESCRIPTIVE).
 THE BUILDING THERMAL ENVELOPE SHALL MEET THE
 REQUIREMENTS OF SECTIONS R402.1.1 THROUGH R402.1.4.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-01-04 Cont ID  
Sent By jpearson Date 2018-01-04 Time 16:15 Rev Time 0.00
Received By jpearson Date 2018-01-04 Time 16:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-11-20 Cont ID  
Sent By jpearson Date 2017-11-20 Time 15:20 Rev Time 0.00
Received By jpearson Date 2017-11-20 Time 14:36 Sent To  
Notes
2017-11-20 15:20:03CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ALL RECEPTACLES IN SHED ARE REQUIRED TO BE GFCI
 PROTECTED. PROVIDE CORRECTION. NEC 210.8; FBC RE 3902.2
 2. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A
 DISCONNECTING MEANS AT THE BUILDING OR SEPARATE
 STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR
 MAIN BREAKER AT THE PANEL FOR PANEL 3. NEC 225.31,
 225.32
 3. PROVIDE GROUNDING ELECTRODE SYSTEM AT SHED AS
 REQUIRED FOR A BUILDING OR STRUCTURE SUPPLIED BY A
 FEEDER OR BRANCH CIRCUIT. NEC 250.32; FBC RE3607.3
 4. PROVIDE ONE LOAD CALCULATION FOR ENTIRE SERVICE WITH
 ALL LOADS INCLUDED TO DETERMINE THAT THE SERVICE IS
 ADEQUATE. A SEPARATE LOAD CALCULATION FOR PANEL 2 IS
 PERMITTED FOR THE WIRE SIZE OF THE FEEDER TO THIS
 PANEL, HOWEVER, THE SAME TYPE OF CALCULATION IS NOT
 PERMITTED FOR PANEL 3. DEMAND FACTORS MAY ONLY BE USED
 WHEN THE FEEDER TO A PANEL IS 100 AMPS OR GREATER.
 PROVIDE FULL LOAD FOR PANEL 3 AND SIZE THE FEEDER WIRE
 AND OVERCURRENT PROTECTION ACCORDINGLY. FBC RE 3602.2;
 NEC 220.82(A)
 5. A CONFLICT EXIST IN THE NOTES ON PLAN. SEVERAL AREAS
 STATE THAT THE 2011 NEC SHOULD BE USED, BUT NOTE 5
 STATES THAT THE 2014 NEC SHOULD BE USED, WHICH IS NOT
 THE CURRENT CODE. PROVIDE CORRECTION. FBC PREFACE
 6. SMOKE AND CO ALARMS SHOULD BE INSTALLED AT LEAST 3
 FEET FROM CEILING FANS OR MECHANICAL GRILLS. PROVIDE
 CORRECTION. NFPA 72, 29.8.3.6 AND .7.
 7. DINING ROOM CIRCUIT IS SHOWN FEEDING THE WALL
 OUTLETS AND LIGHTING WITH THE SAME CIRCUIT. DINING ROOM
 WALL OUTLETS CANNOT BE FED FROM A LIGHTING CIRCUIT.
 PROVIDE CORRECTION. NEC 210.52(B)(2); FBC RE 3703.2
 8. PANEL SCHEDULE FOR PANEL 2 SHOWS CIRCUIT 1 AS A # 12
 WIRE ON A 25 AMP BREAKER; CIRCUIT 19,21 AS A # 12 WIRE
 ON A 60 AMP BREAKER; CIRCUIT 8 AS A # 14 WIRE ON A 20
 AMP BREAKER. PROVIDE CORRECT WIRE AND/OR BREAKER SIZES
 FOR THE AMPACITY OF THE WIRE. NEC 310.15(B)(16); FBC RE
 3705.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2018-01-11 Cont ID  
Sent By tklarge Date 2018-01-12 Time 06:44 Rev Time 0.00
Received By thunt Date 2018-01-11 Time 06:44 Sent To  
Notes
2018-01-11 06:44:51SEPARATE GAS PLAN AND PERMIT REQUIRED FOR GAS.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2017-11-27 Cont ID  
Sent By tklarge Date 2017-11-27 Time 08:59 Rev Time 0.00
Received By tklarge Date 2017-11-27 Time 08:59 Sent To  
Notes
2017-11-27 08:59:43A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A GAS PERMIT IS REQUIRED FOR A CONTRACTOR TO
 PERFORM THE RELATED WORK. PROVIDE COMPLETE PLANS THAT
 REFLECT THE ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB
 AMEND. TO FBC SEC.107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2017-12-22 Cont ID  
Sent By fmittner Date 2017-12-22 Time 14:48 Rev Time 0.00
Received By fmittner Date 2017-12-22 Time 14:48 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2017-11-14 Cont ID  
Sent By fmittner Date 2017-11-14 Time 12:26 Rev Time 0.00
Received By fmittner Date 2017-11-06 Time 16:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-01-25 Cont ID  
Sent By cthroop Date 2018-01-25 Time 07:42 Rev Time 0.00
Received By cthroop Date 2018-01-03 Time 13:50 Sent To I
Notes
2018-01-24 13:50:25IMPACT FEES ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-01-11 Cont ID  
Sent By tklarge Date 2018-01-11 Time 06:44 Rev Time 0.00
Received By tklarge Date 2017-12-13 Time 13:21 Sent To I
Notes
2017-12-14 13:23:09R25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-02 Cont ID  
Sent By cthroop Date 2017-12-02 Time 10:14 Rev Time 0.00
Received By cthroop Date 2017-10-26 Time 14:04 Sent To I
Notes
2017-10-27 14:04:57R25

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2018-01-25 Cont ID  
Sent By cthroop Date 2018-01-25 Time 07:42 Rev Time 0.00
Received By cthroop Date 2018-01-25 Time 07:29 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-12-02 Cont ID  
Sent By cthroop Date 2017-12-02 Time 09:51 Rev Time 0.00
Received By cthroop Date 2017-11-28 Time 11:18 Sent To  
Notes
2017-12-02 09:52:11BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-01-03 Cont ID  
Sent By ccole Date 2018-01-03 Time 09:09 Rev Time 0.00
Received By ccole Date 2018-01-02 Time 09:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-11-27 Cont ID  
Sent By ccole Date 2017-11-27 Time 14:29 Rev Time 0.00
Received By ccole Date 2017-11-27 Time 14:26 Sent To  
Notes
2017-11-27 14:51:271ST REVIEW FBC-2014 RESIDENTIAL MECHANICAL
 PERMIT #17101099
 11/27/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M1: THE AC EQUIPMENT SCHEDULE INDICATES THE
 24000 BTUH (2-TON) AC SYSTEM WILL PRODUCE 6000 CFMS-
 PLEASE CORRECT. THE AVERAGE 2-TON SYSTEM PRODUCES
 APPROXIMATELY 800 CFMS. PLEASE NOTE THAT THE AC LAYOUT
 PLAN IS INDICATING 1150 TOTAL SUPPLY CFMS WHICH ALSO
 EXCEEDS THE CAPACITY OF THE SYSTEM,
  
 2) PROVIDE CONDENSER TIE-DOWN DETAILS PER SECTIONS
 M1305.1.4.1 AND M1401.4.
  
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE RANGE
 HOOD- SEE SECTION M1503.1.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-01-11 Cont ID  
Sent By tklarge Date 2018-01-12 Time 06:43 Rev Time 0.00
Received By thunt Date 2018-01-11 Time 05:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-11-27 Cont ID  
Sent By tklarge Date 2017-11-27 Time 08:58 Rev Time 0.00
Received By tklarge Date 2017-11-27 Time 06:44 Sent To  
Notes
2017-11-27 08:58:401) SUBMIT TWO COPIES OF THE MANUFACTURER'S INSTALLATION
 MANUAL FOR THE TANKLESS WATER HEATERS. WPB AMEND. TO
 FBC SEC. 107.2.1.
 2) SHOW THE DISTANCE OF THE TANKLESS WATER HEATERS FROM
 ALL OPERABLE WINDOWS AND DOORS. THE LOCATION SHALL
 COMPLY WITH THE MANUFACTURER'S INSTALLATION
 INSTRUCTIONS.
 3) SHT. A-4 - SHOW THE FIXTURE CLEARANCES OF THE
 LAVATORY AND WATER CCLOSET IN THE MAIN HOUSE AND ALSO
 IN THE STORAGE SHAED. FIXTURE CLEARANCES SHALL COMPLY
 WITH THE 2014 FBC-RESIDENTIAL SEC.P2705.1.
 4) SHOW THE SHOWER LENGTH AND WIDTH DIMENSIONS ON THE
 FLOOR PLAN FOR THE SHOWER IN THE STORAGE SHED. COMPLY
 WITH 2014 FBC-RES. SEC. P 2708.1.
 5) THE PLANS SHOW THE ENTIRE WATER SYSTEM CONNECTED TO
 AN EXISTINF 1/2 INCH WATER SERVICE. THE WATER SYSTEM
 SHALL BE SIZED TO PROVIDE THE CAPACITIES AND PRESSURES
 TO THE POINT OF OUTLET DISCHARGE IN ACCORDANCE WITH
 2015 FBC RESIDENTIAL SECS. P2903.1, P2903.3 AND TABLE
 P2903.1.
 6) THE MINIMUM SIZE OF THE WATER SERVICE PIPE TO THE
 STRUCTURE AND TO THE STORAGE SHED SHALL BE 3/4 INCH PER
 THE 2014 FBC-RES. SEC. P2903.7.
 7) INDICATE ON THE PLANS IF THE FIREPLACE IS WOOD OR
 GAS BURNING. IF GAS, THIS LOAD SHALL BE ADDED INTO THE
 SIZING OF THE GAS SYSTEM FOR THE TANKLESS WATER
 HEATERS.
 8) SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR THE
 GAS SYSTEM. WPB AMEND. TO FBC SEC. 107.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2017-12-02 Cont ID  
Sent By cthroop Date 2017-12-02 Time 09:43 Rev Time 0.00
Received By cthroop Date 2017-11-28 Time 15:08 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2017-12-22 Cont ID  
Sent By fmittner Date 2017-12-22 Time 14:48 Rev Time 0.00
Received By fmittner Date 2017-12-22 Time 14:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-11-14 Cont ID  
Sent By fmittner Date 2017-11-14 Time 12:26 Rev Time 0.00
Received By fmittner Date 2017-11-14 Time 12:26 Sent To  
Notes
***NONE***