Plan Review Stops For Permit 17101099 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-01-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-06 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-05 |
Time |
12:07 |
Sent To |
|
|
Notes |
2018-01-06 08:42:27 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. SPLIT APPLICATION. CREATE NEW PERMIT FOR SHED. | | 2. ENERGY SUBMITTAL TO BE SIGNED BBY OWNER/AGENT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-12-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-02 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-11-28 |
Time |
11:18 |
Sent To |
|
|
Notes |
2017-12-02 10:14:43 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PRODUCT APPROVAL AFFIDAVIT LIST'S FLO10456-R3, | | FL10446.8 & FL11473-R3. THESE PRODUCT APPROVALS ARE | | MISSING FROM SUBMITTAL. | | 2. ENERGY SUBMITTAL REQUIRES R38 TO BE INSTALLED IN | | ATTIC. PLAN PAGE S2 SHOWS R19. PLEASE CORRECT PLAN | | PAGE. | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE WINDOW, AND DOOR SUBMITTALS. | | | | R402.1 GENERAL (PRESCRIPTIVE). | | THE BUILDING THERMAL ENVELOPE SHALL MEET THE | | REQUIREMENTS OF SECTIONS R402.1.1 THROUGH R402.1.4. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-01-04 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-01-04 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-01-04 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-11-20 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-11-20 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-11-20 |
Time |
14:36 |
Sent To |
|
|
Notes |
2017-11-20 15:20:03 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ALL RECEPTACLES IN SHED ARE REQUIRED TO BE GFCI | | PROTECTED. PROVIDE CORRECTION. NEC 210.8; FBC RE 3902.2 | | 2. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | MAIN BREAKER AT THE PANEL FOR PANEL 3. NEC 225.31, | | 225.32 | | 3. PROVIDE GROUNDING ELECTRODE SYSTEM AT SHED AS | | REQUIRED FOR A BUILDING OR STRUCTURE SUPPLIED BY A | | FEEDER OR BRANCH CIRCUIT. NEC 250.32; FBC RE3607.3 | | 4. PROVIDE ONE LOAD CALCULATION FOR ENTIRE SERVICE WITH | | ALL LOADS INCLUDED TO DETERMINE THAT THE SERVICE IS | | ADEQUATE. A SEPARATE LOAD CALCULATION FOR PANEL 2 IS | | PERMITTED FOR THE WIRE SIZE OF THE FEEDER TO THIS | | PANEL, HOWEVER, THE SAME TYPE OF CALCULATION IS NOT | | PERMITTED FOR PANEL 3. DEMAND FACTORS MAY ONLY BE USED | | WHEN THE FEEDER TO A PANEL IS 100 AMPS OR GREATER. | | PROVIDE FULL LOAD FOR PANEL 3 AND SIZE THE FEEDER WIRE | | AND OVERCURRENT PROTECTION ACCORDINGLY. FBC RE 3602.2; | | NEC 220.82(A) | | 5. A CONFLICT EXIST IN THE NOTES ON PLAN. SEVERAL AREAS | | STATE THAT THE 2011 NEC SHOULD BE USED, BUT NOTE 5 | | STATES THAT THE 2014 NEC SHOULD BE USED, WHICH IS NOT | | THE CURRENT CODE. PROVIDE CORRECTION. FBC PREFACE | | 6. SMOKE AND CO ALARMS SHOULD BE INSTALLED AT LEAST 3 | | FEET FROM CEILING FANS OR MECHANICAL GRILLS. PROVIDE | | CORRECTION. NFPA 72, 29.8.3.6 AND .7. | | 7. DINING ROOM CIRCUIT IS SHOWN FEEDING THE WALL | | OUTLETS AND LIGHTING WITH THE SAME CIRCUIT. DINING ROOM | | WALL OUTLETS CANNOT BE FED FROM A LIGHTING CIRCUIT. | | PROVIDE CORRECTION. NEC 210.52(B)(2); FBC RE 3703.2 | | 8. PANEL SCHEDULE FOR PANEL 2 SHOWS CIRCUIT 1 AS A # 12 | | WIRE ON A 25 AMP BREAKER; CIRCUIT 19,21 AS A # 12 WIRE | | ON A 60 AMP BREAKER; CIRCUIT 8 AS A # 14 WIRE ON A 20 | | AMP BREAKER. PROVIDE CORRECT WIRE AND/OR BREAKER SIZES | | FOR THE AMPACITY OF THE WIRE. NEC 310.15(B)(16); FBC RE | | 3705.1 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2018-01-11 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-01-12 |
Time |
06:44 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-01-11 |
Time |
06:44 |
Sent To |
|
|
Notes |
2018-01-11 06:44:51 | SEPARATE GAS PLAN AND PERMIT REQUIRED FOR GAS. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2017-11-27 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-11-27 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-11-27 |
Time |
08:59 |
Sent To |
|
|
Notes |
2017-11-27 08:59:43 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A GAS PERMIT IS REQUIRED FOR A CONTRACTOR TO | | PERFORM THE RELATED WORK. PROVIDE COMPLETE PLANS THAT | | REFLECT THE ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB | | AMEND. TO FBC SEC.107.2.1. | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | FBC-R, SEC. G2404.3. | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | GAS SEC. 301.3. | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2017-12-22 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-12-22 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-12-22 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-11-14 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-11-06 |
Time |
16:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-01-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-25 |
Time |
07:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-03 |
Time |
13:50 |
Sent To |
I |
|
Notes |
2018-01-24 13:50:25 | IMPACT FEES ROUTED TO CTHROOP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-01-11 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-01-11 |
Time |
06:44 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-12-13 |
Time |
13:21 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-12-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-02 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-26 |
Time |
14:04 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2018-01-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-25 |
Time |
07:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-25 |
Time |
07:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2017-12-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-02 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-11-28 |
Time |
11:18 |
Sent To |
|
|
Notes |
2017-12-02 09:52:11 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | IMPACT FEES AT (561) 233-5025. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-01-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-01-03 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-01-02 |
Time |
09:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-11-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-11-27 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-11-27 |
Time |
14:26 |
Sent To |
|
|
Notes |
2017-11-27 14:51:27 | 1ST REVIEW FBC-2014 RESIDENTIAL MECHANICAL | | PERMIT #17101099 | | 11/27/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M1: THE AC EQUIPMENT SCHEDULE INDICATES THE | | 24000 BTUH (2-TON) AC SYSTEM WILL PRODUCE 6000 CFMS- | | PLEASE CORRECT. THE AVERAGE 2-TON SYSTEM PRODUCES | | APPROXIMATELY 800 CFMS. PLEASE NOTE THAT THE AC LAYOUT | | PLAN IS INDICATING 1150 TOTAL SUPPLY CFMS WHICH ALSO | | EXCEEDS THE CAPACITY OF THE SYSTEM, | | | | 2) PROVIDE CONDENSER TIE-DOWN DETAILS PER SECTIONS | | M1305.1.4.1 AND M1401.4. | | | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE RANGE | | HOOD- SEE SECTION M1503.1. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-01-11 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-01-12 |
Time |
06:43 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2018-01-11 |
Time |
05:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-11-27 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-11-27 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-11-27 |
Time |
06:44 |
Sent To |
|
|
Notes |
2017-11-27 08:58:40 | 1) SUBMIT TWO COPIES OF THE MANUFACTURER'S INSTALLATION | | MANUAL FOR THE TANKLESS WATER HEATERS. WPB AMEND. TO | | FBC SEC. 107.2.1. | | 2) SHOW THE DISTANCE OF THE TANKLESS WATER HEATERS FROM | | ALL OPERABLE WINDOWS AND DOORS. THE LOCATION SHALL | | COMPLY WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | 3) SHT. A-4 - SHOW THE FIXTURE CLEARANCES OF THE | | LAVATORY AND WATER CCLOSET IN THE MAIN HOUSE AND ALSO | | IN THE STORAGE SHAED. FIXTURE CLEARANCES SHALL COMPLY | | WITH THE 2014 FBC-RESIDENTIAL SEC.P2705.1. | | 4) SHOW THE SHOWER LENGTH AND WIDTH DIMENSIONS ON THE | | FLOOR PLAN FOR THE SHOWER IN THE STORAGE SHED. COMPLY | | WITH 2014 FBC-RES. SEC. P 2708.1. | | 5) THE PLANS SHOW THE ENTIRE WATER SYSTEM CONNECTED TO | | AN EXISTINF 1/2 INCH WATER SERVICE. THE WATER SYSTEM | | SHALL BE SIZED TO PROVIDE THE CAPACITIES AND PRESSURES | | TO THE POINT OF OUTLET DISCHARGE IN ACCORDANCE WITH | | 2015 FBC RESIDENTIAL SECS. P2903.1, P2903.3 AND TABLE | | P2903.1. | | 6) THE MINIMUM SIZE OF THE WATER SERVICE PIPE TO THE | | STRUCTURE AND TO THE STORAGE SHED SHALL BE 3/4 INCH PER | | THE 2014 FBC-RES. SEC. P2903.7. | | 7) INDICATE ON THE PLANS IF THE FIREPLACE IS WOOD OR | | GAS BURNING. IF GAS, THIS LOAD SHALL BE ADDED INTO THE | | SIZING OF THE GAS SYSTEM FOR THE TANKLESS WATER | | HEATERS. | | 8) SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR THE | | GAS SYSTEM. WPB AMEND. TO FBC SEC. 107.1. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2017-12-02 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-02 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-11-28 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-12-22 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-12-22 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-12-22 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2017-11-14 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2017-11-14 |
Time |
12:26 |
Sent To |
|
|
Notes |
|
|