Plan Review Details - Permit 17100908
Plan Review Stops For Permit 17100908
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-12-11 Cont ID  
Sent By jgomez Date 2017-12-11 Time 09:13 Rev Time 0.00
Received By jgomez Date 2017-12-11 Time 09:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-11-03 Cont ID  
Sent By jgomez Date 2017-11-03 Time 19:06 Rev Time 0.00
Received By jgomez Date 2017-11-03 Time 19:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-12-08 Cont ID  
Sent By jpearson Date 2017-12-08 Time 14:40 Rev Time 0.00
Received By jpearson Date 2017-12-08 Time 14:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-11-15 Cont ID  
Sent By jpearson Date 2017-11-15 Time 08:06 Rev Time 0.00
Received By jpearson Date 2017-11-15 Time 08:06 Sent To  
Notes
2017-11-15 08:06:05CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ONLY ONE SERVICE PER ADDRESS IS PERMITTED PER CODE.
 REMOVE SERVICE ON GUEST HOUSE AND FEED FROM EXISTING
 SERVICE. FBC RE 3601.2
 2. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE3602.3
 3. PROVIDE NEW RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANELS. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM
 BONDING TERMINATION POINT. NEC 215.5, 230, 250.50,
 250.94, 408.30 FBC RE3706.1, RE3608.1, RE3609.3; FBC
 107.2.1
 4. PROVIDE PANEL SCHEDULES FOR EACH PANEL, INDICATING
 ANY NEW OR ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE
 FOR THESE CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE
 APPLICABLE TO COMPLY WITH CODE. THIS SHOULD INCLUDE
 MAIN HOUSE AND NEW ADDITION. NEC 210.8, 210.12, 215.5,
 408.4; FBC RE3706.2, RE3902
 5. PROVIDE FULL FLOOR PLAN FOR MAIN HOUSE SHOWING ALL
 EXISTING SMOKE ALARMS. IF NONE ARE EXISTING OR NOT TO
 CODE, SHOW AS NEW INSTALLATIONS. FBC R314.3, FBC
 107.2.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
 NEW SETS OF PLANS SUBMITTED. JG.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2017-11-15 Cont ID  
Sent By gjohnson Date 2017-11-15 Time 11:48 Rev Time 0.00
Received By gjohnson Date 2017-11-15 Time 11:47 Sent To  
Notes
2017-11-15 11:48:54GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2017-11-06 Cont ID  
Sent By fmittner Date 2017-11-06 Time 15:42 Rev Time 0.00
Received By fmittner Date 2017-11-06 Time 15:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-12-13 Cont ID  
Sent By jgomez Date 2017-12-13 Time 09:26 Rev Time 0.00
Received By jgomez Date 2017-12-01 Time 14:27 Sent To I
Notes
2017-12-04 14:27:57R34

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-11-15 Cont ID  
Sent By gjohnson Date 2017-11-15 Time 11:49 Rev Time 0.00
Received By gjohnson Date 2017-10-23 Time 13:35 Sent To  
Notes
2017-10-24 13:36:05R31

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2017-11-03 Cont ID  
Sent By jgomez Date 2017-11-03 Time 19:02 Rev Time 0.00
Received By jgomez Date 2017-11-03 Time 19:01 Sent To  
Notes
2017-11-03 19:02:43$180.65 PAID. MU-2017-028640.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2017-11-03 Cont ID  
Sent By jgomez Date 2017-11-03 Time 19:08 Rev Time 0.00
Received By jgomez Date 2017-11-03 Time 19:08 Sent To  
Notes
2017-11-03 19:08:36NO MECHANICAL WORK SHOWN ON THE MAIN HOUSE. JG.

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-12-13 Cont ID  
Sent By jgomez Date 2017-12-13 Time 09:26 Rev Time 0.00
Received By jgomez Date 2017-12-13 Time 08:29 Sent To  
Notes
2017-12-13 08:33:21 
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-11-15 Cont ID  
Sent By gjohnson Date 2017-11-15 Time 11:38 Rev Time 0.00
Received By gjohnson Date 2017-11-15 Time 11:38 Sent To  
Notes
2017-11-15 11:47:351ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. THE ENERGY CALCULATIONS CALL OUT FOR NATURAL GAS
 TANKLESS WATER HEATER BUT ELECTRICAL LOAD CALCULATIONS
 SHOW A 3500 WATT WATER HEATER PLEASE CLARIFY. PER WPB
 AMEND TO FBC 107.2.1
  
 2. LAVATORY ON SECOND FLOOR IS NOT LABELED ON SANITARY
 RISER PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2017-11-06 Cont ID  
Sent By fmittner Date 2017-11-06 Time 15:42 Rev Time 0.00
Received By fmittner Date 2017-11-06 Time 15:42 Sent To  
Notes
***NONE***