Plan Review Details - Permit 17100898
Plan Review Stops For Permit 17100898
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-11-16 Cont ID  
Sent By shill Date 2017-11-16 Time 09:48 Rev Time 0.00
Received By shill Date 2017-11-16 Time 09:48 Sent To  
Notes
2017-11-16 09:49:22PROVISOS
 NOT A BUILDING PERMIT!!! ALL WORK REVIEWED, PERMITTED,
 AND INSPECTED UNDER BUILDING PERMITS
 LIFE SAFETY PER FIRE
 PER ARCHITECT, AN ACCESSIBLE ROUTE TO THE MAIN LEVEL
 WILL BE PROVIDED.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-10-31 Cont ID  
Sent By shill Date 2017-10-31 Time 10:58 Rev Time 0.00
Received By shill Date 2017-10-31 Time 10:58 Sent To  
Notes
2017-10-31 10:58:32CALLED ARCHITECT; PER S.ROY, AN ACCESSIBLE ROUTE TO
 MAIN LEVEL WILL BE PROVIDED FOR THE DURATION OF THIS
 EVENT
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-10-31 Cont ID  
Sent By shill Date 2017-10-31 Time 09:05 Rev Time 0.00
Received By shill Date 2017-10-30 Time 17:59 Sent To  
Notes
2017-10-31 09:06:21****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. PROVIDE 2ND FLOOR PLAN, FBC 107.
  
 2. FBC ACCESSIBILITY 202, IT APPEARS THAT AN ACCESSIBLE
 ROUTE WAS NOT PROVIED. REVISE PLAN TO CLARIFY.
  
 PLEASE FEEL FREE TO CONTACT ME AT YOUR CONVENIENCE IF
 YOU WISH TO DISCUSS.
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2017-11-17 Cont ID  
Sent By wjolin Date 2017-11-17 Time 11:06 Rev Time 0.00
Received By wjolin Date 2017-11-17 Time 10:59 Sent To I
Notes
2017-11-17 11:06:00EVENT HAS BEEN APPROVED BY FIRE MARSHAL LEDUC PER THE
 PROVISIONS SET FORTH IN THE EMAIL DATED 11/16/17.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2017-11-01 Cont ID  
Sent By wjolin Date 2017-11-01 Time 16:36 Rev Time 0.00
Received By wjolin Date 2017-11-01 Time 16:18 Sent To  
Notes
2017-11-01 16:18:35196 BELMONTE ROAD - KIPS BAY
 PERMIT #17100898
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 NOTE: UNLESS NOTED OTHERWISE, ALL FIRE/LIFE SAFETY
 REVIEW COMMENTS REFERENCE NFPA 101-THE LIFE SAFETY CODE
 (2012 EDITION WITH FLORIDA AMENDMENTS.)
  
 WEBSITE KIPSBAYDECORATORSHOWHOUSE.ORG INDICATES A
 COCKTAIL PARTY FOR 100 PEOPLE.
  
 PER THE FLORIDA FIRE PREVENTION CODE (NFPA 101) SECTION
 3.3.188.2 AN ASSEMBLY OCCUPANCY IS DEFINED AS AN
 OCCUPANCY USED FOR A GATHERING OF 50 OR MORE PERSONS
 FOR DELIBERATION, WORSHIP, ENTERTAINMENT, EATING,
 DRINKING, AMUSEMENT, AWAITING TRANSPORTATION, OR
 SIMILAR USES.
  
 PER THE FLORIDA FIRE PREVENTION CODE (NFPA 101)
 SECTION12.2.2.2.3 ANY DOOR IN A REQUIRED MEANS OF
 EGRESS FROM AN AREA HAVING AN OCCUPANT LOAD OF 100 OR
 MORE PERSONS SHALL BE PERMITTED TO BE PROVIDED WITH A
 LATCH OR LOCK ONLY IF THE LATCH OR LOCK IS PANIC
 HARDWARE OR FIRE EXIT HARDWARE.
  
 PER THE FLORIDA FIRE PREVENTION CODE (NFPA 101)
 SECTION12.2.9.1 EMERGENCY LIGHTING SHALL BE PROVIDED.
 EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A MINIMUM
 OF 1.5 HOURS IN THE EVENT OF FAILURE OF NORMAL
 LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE
 ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT
 LESS THAN AN AVERAGE OF 1 FT-CANDLE AND, AT ANY POINT,
 NOT LESS THAN 0.1 FT-CANDLE, MEASURED ALONG THE PATH OF
 EGRESS AT FLOOR LEVEL.
  
 BOTH EXIT STAIRS ARE OPEN (COMMUNICATE BETWEEN BOTH
 FLOORS) AND NOT ENCLOSED IN FIRE-RATED CONSTRUCTION.
 PER THE FLORIDA FIRE PREVENTION CODE (NFPA 101) SECTION
 12.3.1 ANY VERTICAL OPENING SHALL BE PROTECTED AND
 ENCLOSED.
  
 PER THE FLORIDA FIRE PREVENTION CODE (NFPA 101) SECTION
 12.7.8.1 NO SMOKING OR OPEN FLAMES (CANDLES, ETC.) ARE
 PERMITTED.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE COMPLETED
 AT THIS TIME DUE TO LACK OF INFORMATION SUBMITTED ON
 THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED DURING PLAN RESUBMISSION.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-10-27 Cont ID  
Sent By wjolin Date 2017-10-27 Time 16:49 Rev Time 0.00
Received By wjolin Date 2017-10-27 Time 16:49 Sent To  
Notes
2017-10-27 16:51:11SHEET A.04 NOT SUBMITTED FOR REVIEW (1ST AND 2ND FLOOR
 LIFE SAFETY PLAN).

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-11-20 Cont ID  
Sent By lmarchan Date 2017-11-20 Time 07:51 Rev Time 0.00
Received By lmarchan Date 2017-11-15 Time 12:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-11-15 Cont ID  
Sent By cpuell Date 2017-11-15 Time 12:10 Rev Time 0.00
Received By cpuell Date 2017-10-31 Time 09:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-31 Cont ID  
Sent By shill Date 2017-10-31 Time 09:09 Rev Time 0.00
Received By shill Date 2017-10-26 Time 10:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-10-30 Cont ID  
Sent By ajones Date 2017-10-30 Time 15:20 Rev Time 0.00
Received By ajones Date 2017-10-30 Time 15:20 Sent To  
Notes
***NONE***