Plan Review Details - Permit 17100569
Plan Review Stops For Permit 17100569 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2017-11-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-11-09 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-11-09 |
Time |
08:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-10-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-23 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-23 |
Time |
11:38 |
Sent To |
|
|
Notes |
2017-10-23 11:42:03 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | 1. IDENTIFY LOCATION OF WORK FOR BOTH FLOORING AND | | BATHROOM RE-MODEL. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-11-15 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2017-11-15 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2017-11-13 |
Time |
10:05 |
Sent To |
|
|
Notes |
2017-11-14 10:05:56 | SENT TO THUNT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-11-09 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-11-09 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-11-07 |
Time |
13:34 |
Sent To |
I |
|
Notes |
2017-11-08 13:34:24 | RESUB ROUTED TO THUNT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-10-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-23 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-13 |
Time |
16:33 |
Sent To |
|
|
Notes |
2017-10-16 16:33:58 | ROUTED TO PLUMBING INBOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2017-11-15 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-11-15 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-11-15 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2017-11-08 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-11-08 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-11-08 |
Time |
15:16 |
Sent To |
|
|
Notes |
2017-11-08 15:26:26 | 11/8/17 2ND PLUMBING REVIEW**DENIED** | | | | 1) PLEASE PROVIDE CLEAR FLOOR SPACE OUTLINE @ EACH | | REQUIRED PLUMBING FIXTURE AND LIST WHAT DESIGN SPEC | | MODEL YOU ARE USING. HUD 24CFR 100-205 | | | | 2) SHOW OVERALL CABINET HEIGHT MAX 34" COMPLING WITH | | FAIR HOUSING SECTION 100.205 (C) (3) (IV) SECTION (V) | | | | | | CALLED AND SPOKE TO MR.BURGOS ( ARCHITECT OF RECORD) | | AND ADVISED | | | | TIM HUNT | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | 561-805-6695 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-10-19 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-10-19 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-10-19 |
Time |
14:50 |
Sent To |
|
|
Notes |
2017-10-19 15:00:20 | 10/19/17 PLUMBING 1ST REVIEW DENIED | | | | 1) PROVIDE DESCRIPTION OF WORK THAT WILL BE DONE. | | (BATHROOM REMODEL) IS NOT CLEAR WHAT IS BEING DONE.FBC | | 107.2.1 | | | | 2) PROVIDE CLEAR FLOOR SPACES FOR EACH FIXTURE AND | | CABINET HEIGHTS SHOWING COMPLIANCE WITH FAIR HOUSING | | | | | | TIM HUNT | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | 561-805-6695 | | [email protected] | | |
|
|
|