Plan Review Details - Permit 17100327
Plan Review Stops For Permit 17100327
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2019-10-29 Cont ID  
Sent By skennedy Date 2019-10-29 Time 09:02 Rev Time 0.00
Received By skennedy Date 2019-10-29 Time 09:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2018-03-01 Cont ID  
Sent By jgomez Date 2018-03-01 Time 11:26 Rev Time 0.00
Received By jgomez Date 2018-03-01 Time 07:53 Sent To  
Notes
2018-03-01 08:56:05RESIDENTIAL (R3) RE-ROOF THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- THE VALUE OF THE IMPROVEMENT IS MORE THAN $300.000.
 NEED TO COMPLY WITH THE ROOF TO WALL CONNECTIONS
 ACCORDING TO SEC. 708.8 OF FBC-EXISTING BUILDING CODE,
 5TH EDITION (2014). SHOW COMPLIANCE.
  
 RESPONSE: REPEAT COMMENT.
 A) NEED TO PROVIDE MORE DETAILED DESCRIPTION OF HOW THE
 CORNERS OF THE BUILDING ARE GOING TO BE STRAPPED.
 CLEARLY IDENTIFY SPECIFIC STRAPS TO BE INSTALLED AND
 NUMBER OF STRAPS AND NAILS PER CORNER TO VERIFY
 COMPLIANCE WITH THE UPLIFT LOADS AS REQUIRED BY SEC.
 708.8.1 FBC- EXISTING BUILDING. PROVIDE COMPLETE SKETCH
 SHOWING PROPOSED STRAPPING ON EACH CORNER OF THIS
 BUILDING. SEC. 107.2.1 CITY AMENDMENTS.
 NOTE: ESTIMATED VALUE TO STRAP EACH CORNER SEEMS TO BE
 HIGH. PROVIDE A DETAILED BREAKDOWN OF THE SCOPE OF WORK
 REQUIRED TO PROVIDE THE ROOF TO WALL CONNECTIONS TO
 JUSTIFY THE ESTIMATED VALUE OF $1000 PER CORNER.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-01-09 Cont ID  
Sent By jgomez Date 2018-01-09 Time 17:29 Rev Time 0.00
Received By jgomez Date 2018-01-09 Time 15:15 Sent To  
Notes
2018-01-09 15:49:17RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 ORIGINAL COMMENT:
 1- THE VALUE OF THE IMPROVEMENT IS MORE THAN $300.000.
 NEED TO COMPLY WITH THE ROOF TO WALL CONNECTIONS
 ACCORDING TO SEC. 708.8 OF FBC-EXISTING BUILDING CODE,
 5TH EDITION (2014). SHOW COMPLIANCE.
  
 RESPONSE:
 A) THE COST ESTIMATE LETTER FROM HORIZON CUSTOM BUILDER
 INC. TO PROVIDE ROOF TO WALL CONNECTIONS IS INCORRECT.
 THE LETTER IS REFERENCING A BUILDING WITH 12 CORNERS.
 THERE ARE TWO BUILDINGS IN THIS PROPERTY. THE ROOFING
 PERMIT APPLICATION IS FOR THE REAR BUILDING AND IT
 DOESN'T HAVE 12 CORNERS. REVISE LETTER AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 B) NEED TO PROVIDE MORE DETAILED DESCRIPTION OF HOW THE
 FOUR CORNERS OF THE BUILDING ARE GOING TO BE STRAPPED.
 CLEARLY IDENTIFY SPECIFIC STRAP TO BE INSTALLED AND
 NUMBER OF STRAPS AND NAILS PER CORNER. NOTE: ACCORDING
 TO FIGURE R301.2(7) CORNERS ARE 4'-0" X 4'-0" MINIMUM.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 C) LETTER SUBMITTED DOESN'T HAVE ANY SIGNATURE. THE
 LETTER NEEDS TO BE SIGNED BY THE PERSON RESPONSIBLE FOR
 THE ESTIMATE. SEC. 107.2.1 CITY AMENDMENTS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-10-16 Cont ID  
Sent By jgomez Date 2017-10-16 Time 09:26 Rev Time 0.00
Received By jgomez Date 2017-10-16 Time 08:35 Sent To  
Notes
2017-10-16 09:54:32RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- THE VALUE OF THE IMPROVEMENT IS MORE THAN $300.000.
 NEED TO COMPLY WITH THE ROOF TO WALL CONNECTIONS
 ACCORDING TO SEC. 708.8 OF FBC-EXISTING BUILDING CODE,
 5TH EDITION (2014). SHOW COMPLIANCE.
  
 2- INFORMATION MARKED ON THE PACKAGE SUBMITTED IS
 INCORRECT. ACCORDING TO SEC. R301.2.1.4 FBC
 FBC-RESIDENTIAL, 5TH EDITION (2014) THIS HOUSE IS
 LOCATED IN EXPOSURE "C" NOT "B". REVISE AS REQUIRED.
  
 3- PROVIDE FLORIDA PRODUCT APPROVAL COVER PAGE THAT
 CORRESPONDS TO FLORIDA PRODUCT APPROVAL FL16709-R3
 SUBMITTED. AND PROVIDE THE INSTALLATION INSTRUCTIONS
 THAT COMES WITH THIS PRODUCT APPROVAL. GO TO THE
 FLORIDA PRODUCT APPROVAL WEBSITE AND DOWNLOAD
 CORRESPONDING INFORMATION. NOTE: FLORIDA PRODUCT
 APPROVAL COVER PAGE SPECIFIES IF THE PRODUCT IS
 APPROVED AND THE CURRENT CODE. THAT'S WHY THIS COVER
 PAGE IS REQUIRED ALSO.
 FAC 61G20-3.001.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2017-10-12 Cont ID  
Sent By destabro Date 2017-10-12 Time 15:51 Rev Time 0.00
Received By destabro Date 2017-10-12 Time 15:51 Sent To B
Notes
2017-10-12 15:51:3810/12/2017 - FLAT ROOF REPLACEMENT IN-KIND IN REAR.
 MEETS DESIGN GUIDELINES FOR HISTORIC DISTRICT. DLE
2017-10-11 16:52:58ROUTED TO DESIREE ESTABROOK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-03-01 Cont ID  
Sent By jgomez Date 2018-03-01 Time 11:47 Rev Time 0.00
Received By jgomez Date 2018-02-27 Time 11:37 Sent To I
Notes
2018-02-28 11:38:00RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-01-09 Cont ID  
Sent By jgomez Date 2018-01-09 Time 17:29 Rev Time 0.00
Received By jgomez Date 2018-01-08 Time 13:11 Sent To  
Notes
2018-01-09 13:11:41RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-16 Cont ID  
Sent By jgomez Date 2017-10-16 Time 10:22 Rev Time 0.00
Received By jgomez Date 2017-10-10 Time 14:10 Sent To  
Notes
2017-10-10 14:10:24ROUTED TO HISTORIC VIA ZONING INBOX


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved