Plan Review Stops For Permit 17100279 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-03-23 |
Time |
18:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-03-23 |
Time |
18:12 |
Sent To |
|
|
Notes |
2018-03-23 18:46:07 | APPROVED WITH EXCEPTIONS | | BUILDING PROVISO | | | | 1) THE PERMIT (#06050833) FOR THE ADDITION TO THE REAR | | OF THE STRUCTURE EXPIRED PRIOR TO RECEIVING ALL OF THE | | REQUIRED INSPECTIONS. PLEASE BE ADVISED THE INSPECTOR | | MAY REQUIRE PREVIOUSLY COMPLETED WORK TO BE MADE | | ACCESSIBLE AND OPEN FOR INSPECTION OR REQUIRE | | ADDITIONAL DOCUMENTATION FOR ALL CONCEALED WORK | | PREVIOUSLY COMPLETED PURSUANT TO FBC 110 & FBC 117. | | FBC 110.1 GENERAL - CONSTRUCTION OR WORK FOR WHICH A | | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY | | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK | | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION | | PURPOSES UNTIL APPROVED. | | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR | | TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE | | TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN | | APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. | | | | 2) A SET OF THE APPROVED PLANS FROM THE EXPIRED PERMIT | | (#06050833) HAS BEEN PROVIDED FOR REFERENCE AND TO AID | | THE INSPECTORS WITH THEIR FIELD INSPECTIONS. FBC | | 107.2.1.3 | | | | 3) A SET OF THE APPROVED PRODUCT APPROVALS FROM THE | | EXPIRED PERMIT (#06050833) HAS BEEN PROVIDED FOR | | REFERENCE AND TO AID THE INSPECTORS WITH THEIR FIELD | | INSPECTIONS. FBC 107.2.1.3 THE RECORDS INDICATE THAT | | THE FOLLOWING STRUCTURAL INSPECTIONS WERE APPROVED: 114 | | - SLAB, 105 - FOOTING, 120 - BEAM/COLUMN, 111 - ROOF | | FRAMING, 118 - ROOF SHEATHING, AND A 119 WINDOW/DOOR | | BUCK. SEE ATTACHED COPY OF INSPECTION RESULTS FROM | | EXPIRED PERMIT (#06050833). | | | | 4) OWNER/AGENT TO SIGN AND DATE ENERGY FORM. | | | | 5) SUBMIT TWO SETS OF INSTALLATION INSTRUCTION FOR THE | | TAMKO ASPHALT SINGLES. | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-01-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-01-08 |
Time |
18:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-01-08 |
Time |
16:21 |
Sent To |
|
|
Notes |
2018-01-08 18:42:50 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE PERMIT (#06050833) FOR THE ADDITION TO THE REAR | | OF THE STRUCTURE EXPIRED PRIOR TO RECEIVING ALL OF THE | | REQUIRED INSPECTIONS. | | PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY | | COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR | | INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL | | CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110 | | & FBC 117. | | FBC 110.1 GENERAL - CONSTRUCTION OR WORK FOR WHICH A | | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY | | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK | | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION | | PURPOSES UNTIL APPROVED. | | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR | | TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE | | TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN | | APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. | | | | 2) OBTAIN A SET OF THE APPROVED PLANS THAT EXPIRED | | (PERMIT #06050833) AND SUBMIT THEM WITH THE NEW PLANS | | FOR REFERENCE AND TO AID THE INSPECTORS WITH THEIR | | FIELD INSPECTIONS. FBC 107.2.1.3 (CONTACT CRAIG | | MCPHERSON AT 561-805-6684 OR [email protected] TO | | OBTAIN COPIES FROM OUR FILES.) | | | | 3) SUBMIT A SET OF THE APPROVED PRODUCT APPROVALS FOR | | THE EXPIRED PERMIT AND SUBMIT THEM FOR REFERENCE AND TO | | AID THE INSPECTORS WITH THEIR FIELD INSPECTIONS. FBC | | 107.2.1.3 | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-11-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-03 |
Time |
19:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-03 |
Time |
16:08 |
Sent To |
|
|
Notes |
2017-11-03 18:32:21 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE PERMIT (#06050833) FOR THE ADDITION TO THE REAR | | OF THE STRUCTURE EXPIRED PRIOR TO RECEIVING ALL OF THE | | REQUIRED INSPECTIONS. | | PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY | | COMPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR | | INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL | | CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110 | | & FBC 117. | | FBC 110.1 GENERAL - CONSTRUCTION OR WORK FOR WHICH A | | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY | | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK | | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION | | PURPOSES UNTIL APPROVED. | | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR | | TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE | | TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN | | APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. | | | | 2) OBTAIN A SET OF THE APPROVED PLANS THAT EXPIRED | | (PERMIT #06050833) AND SUBMIT THEM WITH THE NEW PLANS | | FOR REFERENCE AND TO AID THE INSPECTORS WITH THEIR | | FIELD INSPECTIONS. FBC 107.2.1.3 (CONTACT CRAIG | | MCPHERSON AT 561-805-6684 OR [email protected] TO | | OBTAIN COPIES FROM OUR FILES.) | | | | 3) SUBMIT A SET OF THE APPROVED PRODUCT APPROVALS FOR | | THE EXPIRED PERMIT AND SUBMIT THEM FOR REFERENCE AND TO | | AID THE INSPECTORS WITH THEIR FIELD INSPECTIONS. FBC | | 107.2.1.3 | | | | 4) SPECIFY THE ATTACHEMENT OF THE 4 X 6 WOOD POSTS TO | | THE GLULAM BEAM IN THE DETAIL ON 4.1. FBC-R 301.1 | | | | 5) THE NOTES FOR THE UPTURN BEAM ON SHEETS 2.1 AND 3.1 | | STATE, "SEE DETAIL THIS SHEET.". THERE IS NO DETAIL FOR | | THE UPTURN BEAM ON THESE SHEETS. PLEASE CORRECT. FBC | | 107.2.1 | | | | 6) REVISE THE TYPICAL WALL SECTION ON SHEET 4.1 TO | | SPECIFY 8D RING SHANK NAILS PER FBC-R 803.2.3.1. | | | | 7) REVISE THE TYPICAL WALL SECTION ON SHEET 4.1 TO | | SPECIFY A DOUBLE LAYER OF UNDERLAYMENT AS REQUIRED BY | | FBC-R 905.2.2 FOR ROOF SLOPES LESS THAN 4:12. | | | | 8) SHOW COMPLIANCE WITH FBC-R 314.3.1 WHEN ALTERATIONS, | | REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN | | ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN | | EXISTING DWELLINGS, THE INDIVIDUAL DWELLING UNIT SHALL | | BE EQUIPPED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR | | NEW DWELLINGS. | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-03-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-03-22 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-03-22 |
Time |
07:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-01-05 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-01-05 |
Time |
07:39 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-01-05 |
Time |
06:32 |
Sent To |
|
|
Notes |
2018-01-05 07:39:35 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS: | | 1. CORRECTED. | | 2. CORRECTED. | | 3. CORRECTED. | | 4. CORRECTED. | | 5. CORRECTED. | | 6. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. NEC 250.94; FBC RE3609.3 (NOT SHOWN ON PLAN.) | | 7. CORRECTED. | | | | NEW COMMENT: | | 8. PER THE WPB AMENDMENTS TO THE FBC, PLAN IS REQUIRED | | TO BEAR THE NAME AND BE SIGNED AND SEALED BY THE PERSON | | RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. FBC | | 107.2.1, FS 471, 481, 481.229 | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-10-31 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-10-31 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-10-31 |
Time |
08:15 |
Sent To |
|
|
Notes |
2017-10-31 08:15:02 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. BLOCK NOTE STATES THAT RECEPTACLES SHALL BE TAMPER | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | CORRECTION. NEC 406.12; FBC RE4002.14 | | 2. SHOW ALL SMOKE AND CO ALARMS IN HOUSE. PLAN | | CURRENTLY ONLY SHOWS NEW AREA FOR THESE ALARMS. IF NONE | | ARE EXISTING, OR NOT TO CODE, PROVIDE AS NEW | | INSTALLATION. FBC R314.3, FBC 107.2.1 | | 3. PANEL SCHEDULE SHOWS TWO AHU'S AT 10KW EACH, BUT THE | | LOAD CALCULATION SHOWS ONE AT 10 KW AND ONE AT 1 KW. | | PROVIDE CORRECTED LOAD CALCULATION. NEC 220; FBC | | RE3602.3 | | 4. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE | | SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC | | 410.10(D); FBC RE4003.11 | | 5. PER CODE: "LIGHTING WITH OPEN OR PARTIALLY ENCLOSED | | LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT | | BE PERMITTED IN CLOTHES CLOSETS". PROVIDE CORRECTION. | | NEC 410.16; FBC RE4003.12 | | 6. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. NEC 250.94; FBC RE3609.3 | | 7. FOR AHU INSTALLED IN ATTIC, CODE REQUIRES: "A | | LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE | | REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET | | SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN | | ACCORDANCE WITH CHAPTER 34." PROVIDE RECEPTACLE OUTLET | | PER CODE. FBC-RE M1305.1.3.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-03-28 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2018-03-28 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2018-03-19 |
Time |
11:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-02-05 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2018-02-05 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2017-12-27 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-11-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-06 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-10-10 |
Time |
13:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2017-11-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-03 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-03 |
Time |
16:11 |
Sent To |
|
|
Notes |
2017-11-06 07:20:06 | IMPACT FEES PAID UNDER EXPIRED PERMIT #06050833. | | P.R. #06-62005 PAID $2347.26 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-03-23 |
Time |
18:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-03-23 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2018-01-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-01-08 |
Time |
17:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-01-08 |
Time |
17:37 |
Sent To |
|
|
Notes |
2018-01-08 18:38:50 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY MECHANICAL | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC-R - M1401.3 SIZING. HEATING AND COOLING | | EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS | | CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER | | APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. | | PROVIDE EQUIPMENT SIZING CALCULATIONS. | | | | 2) FBC ENERGY CONSERVATION SECTIONS R101.5.1.1.1 OR | | R101.5.1.1.2. SUBMIT TWO SETS OF ENERGY COMPLIANCE | | FORMS AS REQUIRED. | | | | 3) SPECIFY THE MODEL NUMBERS AND SPECIFICATIONS FOR THE | | HEATING AND COOLING EQUIPMENT, THAT MATCHES THE | | EQUIPMENT SIZING CALCULATIONS, ON THE PLANS. AIR | | HANDLER INFORMATION IS MISSING. PROVIDE AHRI | | CERTIFICATIONS FOR THE EQUIPMENT. FBC-R M1401.3 | | | | 4) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-11-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2017-11-06 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2017-11-06 |
Time |
06:50 |
Sent To |
I |
|
Notes |
2017-11-06 08:18:16 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY MECHANICAL | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC-R - M1401.3 SIZING. HEATING AND COOLING | | EQUIPMENT SHALL BE SIZED BASED ON BUILDING LOADS | | CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER | | APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. | | PROVIDE EQUIPMENT SIZING CALCULATIONS. | | | | 2) FBC ENERGY CONSERVATION SECTIONS R101.5.1.1.1 OR | | R101.5.1.1.2. SUBMIT TWO SETS OF ENERGY COMPLIANCE | | FORMS AS REQUIRED. | | | | 3) FBC-R - M1305.1.3 APPLIANCES IN ATTICS. | | ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN | | OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE | | ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, BUT | | NOT LESS THAN 30 INCHES (762 MM) HIGH AND 22 INCHES | | (559 MM) WIDE AND NOT MORE THAN 6 FEET (1829 MM) LONG | | MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM | | THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE | | CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH CHAPTER 5 | | NOT LESS THAN 24 INCHES (610 MM) WIDE. A LEVEL SERVICE | | SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES | | (762 MM) WIDE SHALL BE PRESENT ALONG ALL SIDES OF THE | | APPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR ACCESS | | OPENING DIMENSIONS SHALL BE A MINIMUM OF 20 INCHES BY | | 30 INCHES (508 MM BY 762 MM), AND LARGE ENOUGH TO ALLOW | | REMOVAL OF THE LARGEST APPLIANCE. | | | | 4) SPECIFY THE MODEL NUMBERS AND SPECIFICATIONS FOR THE | | HEATING AND COOLING EQUIPMENT, THAT MATCHES THE | | EQUIPMENT SIZING CALCULATIONS, ON THE PLANS. PROVIDE | | AHRI CERTIFICATIONS FOR THE EQUIPMENT. FBC-R M1401.3 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-03-23 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-03-23 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-01-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-01-08 |
Time |
17:06 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-01-08 |
Time |
17:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-10-23 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2017-10-23 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2017-10-23 |
Time |
15:29 |
Sent To |
|
|
Notes |
2017-10-23 15:42:14 | 10/23/17 1ST PLUMBING REVIEW DENIED | | | | 1) VALUE SEEMS LOW AND APPREARS TO HAVE BEEN CHANGED | | AFTER QUALIFIER FILL OUT APPLICATION. PROVIDE BONA FIDE | | SIGED CONTRACT FBC 109.3 | | | | 2) PROVIDE SANITARY ISOMETRIC DRAWNING OF THE PLUMBING | | SYSTEM FBC 107.2.1 | | | | 3) SHOW SIZING AND SOURCE OF HOT WATER FBC 107.2.1 | | | | TIM HUNT | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | 561-805-6695 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-03-23 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-03-23 |
Time |
14:48 |
Sent To |
|
|
Notes |
2018-03-23 15:19:55 | TAMKO ASPHALT SHINGLES, FL1956-R12 ( NEEDS TO SUBMIT | | INSTALLATION INSTRUCTIONS.) |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2018-01-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-01-08 |
Time |
18:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-01-08 |
Time |
18:43 |
Sent To |
|
|
Notes |
2018-01-08 18:55:26 | 1) THE ROOFING PERMIT FOR THE ADDITION EXPIRED WITHOUT | | AN APPROVED FINAL INSPECTION. YOU ARE REQUIRED TO | | ACQUIRE A ROOFING PERMIT IN ORDER TO GET THE ROOFING | | FINAL INSPECTION APPROVED. | | | | 2) SUBMIT TWO SETS OF THE PRODUCT APPROVALS FOR THE | | ASPHALT ROOF SHINGLES. FBC 107.3.4 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2018-03-28 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2018-03-28 |
Time |
15:35 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2018-03-28 |
Time |
15:21 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2018-01-22 |
|
|
Cont ID |
|
Sent By |
ES |
Date |
2018-01-22 |
Time |
11:08 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2018-01-19 |
Time |
15:40 |
Sent To |
|
|
Notes |
2018-01-22 11:11:27 | FAILED | | | | 1) REPEAT COMMENT: THE ORIGINAL EXPIRED PERMIT WAS FOR | | AN ADDITION. PROVIDE TWO COPIES OF A SURVEY SHOWING THE | | SETBACKS FOR THE BUILDING. | | | | 2) REPEAT COMMENT: THE SURVEY NEEDS TO SHOW THE | | PROPOSED LOCATION OF THE NEW AC UNIT AND THE PAD. THE | | A/C UNIT AND PAD NEED TO BE SHOWN TO SCALE. THE SETBACK | | DIMENSION FROM THE A/C UNIT AND THE PAD MUST BE SHOWN | | TO THE PROPERTY LINE. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-11-01 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2017-11-01 |
Time |
14:49 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2017-11-01 |
Time |
14:49 |
Sent To |
|
|
Notes |
2017-11-01 14:54:13 | FAILED | | | | 1) THIS ORIGINAL PERMIT WAS FOR AN ADDITION. PROVIDE | | TWO COPIES OF A SURVEY SHOWING THE SETBACKS FOR THE | | BUILDING. | | | | 2) THE SURVEY NEEDS TO SHOW THE PROPOSED LOCATION OF | | THE NEW AC UNIT AND THE PAD. THE A/C UNIT AND PAD NEED | | TO BE SHOWN TO SCALE. THE SETBACK DIMENSION FROM THE | | A/C UNIT AND THE PAD MUST BE SHOWN TO THE PROPERTY | | LINE. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | [email protected] |
|
|