Plan Review Stops For Permit 17100146 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
N |
Date |
2017-11-21 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-11-21 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-11-21 |
Time |
08:35 |
Sent To |
|
|
Notes |
2017-11-21 08:35:57 | SEE 17110466 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-10-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2017-10-18 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2017-10-18 |
Time |
12:46 |
Sent To |
|
|
Notes |
2017-10-18 12:53:23 | ****CORRECTIONS**** | | **SENT EMAIL TO [email protected] ON 10/18/2017 | | ADVISING THAT THEY NEED TO APPLY FOR TENT PERMIT, SENT | | EMAIL ON 10/23/17 ADVISING THAT EVENT APPLICATION HAS | | COMMENTS WITH INSTRUCTIONS ON HOW TO SEE COMMENTS; | | SPOKE WITH APPLICANT ON TELEPHONE** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | | | 1. FBC B 3103, REVISE PLAN TO INCLUDE THE FOLLOWING | | INFORMATION: | | | | OCCUPANCY CLASSIFICATION FBC B CHAPTER 3 | | OCCUPANT LOAD FBC B 1004 | | MEANS OF EGRESS (WIDTH OF AISLES, EXITS) | | INFORMATION REGARDING EXITS - REVISE PLAN TO INDICATE | | WHETHER THESE ARE DOORS OR GATES, AND REVISE PLAN TO | | NOTE PANIC BAR/FIRE EXIT HARDWARE REQUIREMENT ON ALL | | DOORS AND GATES FBC B 1008.1.10. | | A NUMBER OF UNIDENTIFIED RECTANGLES ARE DEPICTED; | | REVISE PLAN TO INDENTIFY. ADDITIONAL INFORMATION MAY BE | | REQUIRED | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2017-11-21 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-11-21 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-11-21 |
Time |
|
Sent To |
|
|
Notes |
2017-11-21 08:36:50 | SEE 17110469 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2017-10-19 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2017-10-19 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2017-10-19 |
Time |
08:09 |
Sent To |
|
|
Notes |
2017-10-19 08:12:06 | FLORIDA BUILDING CODE 2014 5TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | NFPA 70 2011 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | NEED AN ELECTRICAL LAYOUT ON HOW POWER WILL BE SUPPLIED | | THROUGHOUT THE TENT. ARTICLE 590 OF THE NEC APPLIES. | | | | NEED LIGHTING, EXITING SIGNS, AND OUTLET LAYOUT. IF AC | | IS SUPPLIED PLEASE INCLUDE POWER PLAN. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-11-21 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
2017-11-21 08:39:10 | SEE 17110466 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2017-10-18 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2017-10-18 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2017-10-18 |
Time |
10:27 |
Sent To |
|
|
Notes |
2017-10-18 11:30:12 | PERMIT # 17100149 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | FAILED COMMENTS: | | | | 1) THIS SITE IS A VACANT LOT / PARKING LOT WITH NO | | STRUCTURE ON IT. THE SITE PLAN SHOWS AN ENCLOSED | | STRUCTURE. ADDITIONAL INFORMATION IS REQUIRED REGARDING | | TEMPORARY STRUCTURE INTENDING TO BE PLACED ON THIS | | SITE. | | | | 2) PLEASE INCLUDE A LIFE SAFETY PLAN THAT CLEARLY | | INDICATES: SQUARE FOOTAGE OF STRUCTURE, OCCUPANCY LOAD | | CALCULATION, EXIT SIGNS, EMERGENCY LIGHTING, TRAVEL | | DISTANCES, COMMON PATH OF TRAVEL, LOCATION OF FIRE | | EXTINGUISHERS, ETC. | | | | 3) PLEASE INCLUDE DETAILS REGARDING LOCATION OF | | RESTROOMS, GENERATORS, AND ANY ADDITIONAL TENTS OR | | TEMPORARY STRUCTURES, IF ANY. | | | | 3) A SEPERATE PERMIT FOR TEMPORARY STRUCTURES AND TENTS | | IS REQUIRED. | | | | 4) A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE | | COMPLETED AT THIS TIME DUE TO LACK OF INFORMATION | | SUBMITTED ON THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS | | MAY BE GENERATED DURING PLAN RESUBMISSION. | | | | | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | FIRE INVESTIGATOR & INSPECTOR | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 804-4751 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-11-21 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-11-21 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-10-18 |
Time |
07:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2017-11-21 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2017-11-21 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2017-11-21 |
Time |
08:34 |
Sent To |
|
|
Notes |
2017-11-21 08:35:04 | SEE 17110466 FOR PLUMBING FACILITIES PROVIDED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2017-10-20 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2017-10-20 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2017-10-20 |
Time |
06:42 |
Sent To |
|
|
Notes |
2017-10-20 06:47:01 | 1) SHOW THE LOCATION OF PORTABLE SANITARY FACILITIES ON | | THE SITE PLAN. THE PORTABLE FACILITIES SHALL INCLUDE A | | MINIMUM OF ONE MALE AND ONE FEMALE FULLY HANDICAPPED | | ACCESSIBLE UNIT WITH AN ACCESSIBLE ROUTE TO THE UNIT. | | 2) PROVIDE THE NUMBER OF FACILITIES THAT WILL BE | | PROVIDED FOR THE MALES AND THE FEMALES. | | 3) INDICATE ON THE PLANS IF ANY COOKING WILL BE DONE | | AND IF ANY LP GAS WILL BE USED. IF SO, SUBMIT DETAILS | | ON THE SIZE OF THE LP TANKS, LOCATION OF TANKS AND | | COOKING FACILITIES, PIPING, ETC.GAS PERMIT MAY BE | | REQUIRED. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2017-11-16 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2017-11-16 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2017-11-16 |
Time |
09:55 |
Sent To |
|
|
Notes |
|
|