Plan Review Stops For Permit 17090693 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-01-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-03 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-03 |
Time |
11:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-12-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-05 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-12-05 |
Time |
10:25 |
Sent To |
|
|
Notes |
2017-12-05 11:43:27 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 2ND REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROPOSED HOUSE IS LOCATED IN A FLOOD ZONE. PROVIDE | | ELEVATION CERTIFICATE. | | 2. ENERGY SUBMITTAL TO BE SIGNED BY OWNER/AGENT. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-10-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-26 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-25 |
Time |
07:19 |
Sent To |
M |
|
Notes |
2017-10-26 15:12:08 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PER FOUNDATION NOTE ON PAGE S-0, PROVIDE A SIGNED | | AND SEALED GEOTECHNICAL REPORT. THE REPORT SHALL BE | | ISSUED BY AN ACCREDITED LABORATORY. | | 2. OWNER/AGENT TO SIGN ENERGY SUBMITTAL. | | 3. DETAIL 3, PAGE A-5 SPECIFIES 1X2 WOOD FURRING ON | | INTERIOR WALLS. TYPICAL DOOR AND WINDOW SILL DETAILS ON | | PAGE A-6 SPECIFIES 15/8 METAL FURRING. PLEASE CLARIFY. | | 4. PLEASE PROVIDE AN INTERPRETATION FOR THE | | INSTALLATION OF SHERWIN WILLIAMS SHER-CRETE FLEXIBLE | | CONCRETE WATER PROOFING AT ALL DOOR AND WINDOW MASONRY | | OPENINGS. IS THIS A QA/QC MEASURE OR A CODE | | REQUIREMENT? PLEASE CLARIFY. | | 5. TYPICAL DOOR BUCK DETAIL ON PAGE A-6 SPECIFIES 2X | | P.T. WOOD BUCKS TO BE ATTACHED PER PRODUCT APPROVALS. | | PRODUCT APPROVALS SPECIFIES WOOD BUCK DESIGN AND | | INSTALLATION IS THE RESPONSIBILITY OF THE EOR AND AOR. | | PROVIDE ATTACHMENT DETAIL FOR 2X WOOD BUCKS AT EXT. | | DOORS. | | 6. NOTICE - MANDATORY RESIDENTIAL AIR INFILTRATION | | (BLOWER DOOR) TEST REQUIRED. | | 7. TYPICAL WINDOW ANCHORAGE DETAIL, PAGE A-6 REQUIRES A | | MIN. OF R-7.0 FOIL INSULATION. ENERGY SUBMITTAL | | REQUIRES A MIN. OF R-4.2. PLEASE CLARIFY. | | 8. PROVIDE CERTIFICATE OF TERMITE TREATMENT PER FBC, | | SETION 1816. | | 9. REFERENCE CONCRETE BEAM AND MASONRY LINTEL SCHEDULE, | | PAGE S-1. IDENTIFY WHAT A MB-3 IS FOR AN 8" WALL? | | 10. REFERENCE CONCRETE COLUMN SCHEDULE, PAGE S-1. THE | | DESCRIPTION FOR TWO DIFFERENT FILLED CELL REINFORCEMENT | | REQUIREMENTS APPEARS TO BE THE SAME. PLEASE CLARIFY. | | 11. THE VERTICAL REINFORCEMENT SPACING FOR A MW-1 TYPE | | WALL, SEE MASONRY WALL SCHEDULE, PAGE S-1, DOES NOT | | CORRESPOND TO THE VERTICAL SPACING ON THE FOUNDATION | | PLAN. PLEASE CLARIFY. | | 12. REFERENCE SOIL STATEMENT, PAGE S-1. PLEASE CLARIFY | | WHAT THE STATEMENT "WITH THE SO S PREPERATION, ETC." | | MEANS IN ITEM B. | | 13. PROVIDE SHOP DRAWINGS FOR PROPOSED STAIRS. THESE | | MAY BE LISTED AS A DEFFERRED SUBMITTAL. SHOP DRAWINGS | | MUST BE REVIEWED AND APPROVED PRIOR TO INSTALLATION. | | 14. ROOF SHEATHING FASTENER DETAIL 2, PAGE A-5 IS IN | | CONFLICT WITH ROOF SHEATHING FASTENER SCHEDULE, PAGE | | S-2. PLEASE CLARIFY. | | 15. REFERENCE DETAIL D, PAGE S-6. THERE ARE TWO | | DIFFERENT SHEATING PRODUCTS LISTED FOR THE SAME | | INSTALLATION. BOTH PRODUCTS ARE IN CONFLICT WITH THE | | SHEATHING DETAIL ON PAGE A-5. PLEASE CLARIFY. | | 16. REFERENCE DETAIL H, PAGE S-7. HORIZONTAL | | REINFORCEMENT (DUROWALL) REQUIRED FOR MASONRY WALLS PER | | FBCR 606.12.2.2.3. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2017-11-27 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2017-11-27 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2017-11-27 |
Time |
07:41 |
Sent To |
|
|
Notes |
2017-11-27 07:41:02 | NO CHANGE TO PLANS PREVIOUSLY APPROVED BY FG. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2017-10-03 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2017-10-03 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2017-10-03 |
Time |
11:45 |
Sent To |
|
|
Notes |
2017-10-03 11:53:25 | THIS PLAN HAS BEEN PASSED PROVISIONALLY. | | | | PLAN HAS BEEN MARKED ACCORDINGLY. | | | | 1. ALL OUTDOOR GFCI RECEPTACLES WILL BE OF THE WP TYPE | | NEC 406.9(B1) | | | | 2. OUTDOOR LUMINAIRES WILL BE SUITABLE FOR USE IN WET | | LOCATION. IF LUMINAIRE IS A HIGH HAT "CAN" TYPE IT WILL | | HAVE A VP TRIM. NEC 410.10 | | | | 3. GARAGE DOOR OPENER RECEPTACLES REQUIRE GFCI | | PROTECTION. NEC 210.8 (A2) | | | | 4. CIRCUIT A-18 FOR SMALL APPLIANCE WILL NOT SERVE D/W | | OR DISPOSAL. NEC 210.52(B2) | | | | 5. FBC-R M1305.1.3.2 AIR-HANDLING UNITS. | | AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS IF THE | | FOLLOWING CONDITIONS ARE MET: | | (1)THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | | | 6. BOND GAS AND C/W PIPE IF APPLICABLE. NEC 250.104 | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | 5TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | PART VIII ELECTRICAL | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | FRANK GIAQUINTO | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | DEVELOPMENT SERVICES DEPT. | | CELL 561-657-1653 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-01-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-03 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-12-14 |
Time |
14:06 |
Sent To |
I |
|
Notes |
2017-12-15 14:06:29 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-12-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-05 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-11-02 |
Time |
13:17 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2017-11-08 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2017-09-27 |
Time |
14:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
P |
Date |
2017-10-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-25 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-25 |
Time |
07:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2017-12-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-12-28 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-12-28 |
Time |
14:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2017-11-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-11-22 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-11-22 |
Time |
13:39 |
Sent To |
|
|
Notes |
2017-11-22 13:42:42 | 2ND REVIEW FBC-2014 RESDIENTIAL MECHANICAL | | PERMIT #17090693 | | 11/1/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | THE 1ST REVIEW COMMENTS WERE NOT ADDRESSED AND STILL | | EXIST. I HAVE REPRINTED THEM BELOW- PLEASE COMPLY. | | | | 1ST REVIEW FBC-2014 RESDIENTIAL MECHANICAL | | PERMIT #17090693 | | 11/1/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) TWO DIFFERENT SETS OF MECHANICAL PLANS BY TWO | | DIFFERENT DESIGNERS HAVE BEEN SUBMITTED. THERE ARE THE | | M-1 & M-2 PLANS IN THE MAIN PLANS SETS PREPARED BY THE | | ARCHITECT OF RECORD, AND AN M.1 PLAN SEPARATE FROM THE | | MAIN SETS PREPARED BY K.O. ENERGY DESIGN. PLEASE CHOOSE | | ONE OF THE DESIGNS AND REMOVE THE OTHER. PLEASE NOTE | | THAT THE ENERGY AND AC CALCULATIONS WERE PREPARED BY K. | | O. ENERGY DESIGN, AND THE COMPLIANCE DATA LISTED FOR | | THE AC SYSTEM DOES NOT MATCH THE SCHEDULE ON THE MAIN | | SETS. | | | | 2) THE AIR BARRIER AND INSPECTION CHECKLIST IS NOT | | ATTACHED WITH THE ENERGY COMPLIANCE FORM R405-2014. | | PLEASE PROVIDE THE CHECKLIST. | | | | 3) FORM R405 IS MISSING THE OWNER/AGENT'S SIGNATURE AND | | DATE. | | | | 4) THE AC LOAD CALCS ARE INDICATING THE FRONT DOOR | | FACES SOUTH HOWEVER THE MAPS SHOW THE FRONT DOOR MUST | | FACE NORTH. | | | | 5) THE 10KW HEATER SPECIFIED IN THE K.O. ENERGY | | EQUIPMENT SCHEDULE IS UNDERSIZED FOR THE 48,948 | | CALCULATED HEATING LOAD- MINIMUM 14KW REQUIRED | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2017-11-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2017-11-01 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2017-11-01 |
Time |
09:43 |
Sent To |
|
|
Notes |
2017-11-01 10:00:24 | 1ST REVIEW FBC-2014 RESDIENTIAL MECHANICAL | | PERMIT #17090693 | | 11/1/17 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) TWO DIFFERENT SETS OF MECHANICAL PLANS BY TWO | | DIFFERENT DESIGNERS HAVE BEEN SUBMITTED. THERE ARE THE | | M-1 & M-2 PLANS IN THE MAIN PLANS SETS PREPARED BY THE | | ARCHITECT OF RECORD, AND AN M.1 PLAN SEPARATE FROM THE | | MAIN SETS PREPARED BY K.O. ENERGY DESIGN. PLEASE CHOOSE | | ONE OF THE DESIGNS AND REMOVE THE OTHER. PLEASE NOTE | | THAT THE ENERGY AND AC CALCULATIONS WERE PREPARED BY K. | | O. ENERGY DESIGN, AND THE COMPLIANCE DATA LISTED FOR | | THE AC SYSTEM DOES NOT MATCH THE SCHEDULE ON THE MAIN | | SETS. | | | | 2) THE AIR BARRIER AND INSPECTION CHECKLIST IS NOT | | ATTACHED WITH THE ENERGY COMPLIANCE FORM R405-2014. | | PLEASE PROVIDE THE CHECKLIST. | | | | 3) FORM R405 IS MISSING THE OWNER/AGENT'S SIGNATURE AND | | DATE. | | | | 4) THE AC LOAD CALCS ARE INDICATING THE FRONT DOOR | | FACES SOUTH HOWEVER THE MAPS SHOW THE FRONT DOOR MUST | | FACE NORTH. | | | | 5) THE 10KW HEATER SPECIFIED IN THE K.O. ENERGY | | EQUIPMENT SCHEDULE IS UNDERSIZED FOR THE 48,948 | | CALCULATED HEATING LOAD- MINIMUM 14KW REQUIRED | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
2 |
Status |
P |
Date |
2018-01-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-01-03 |
Time |
12:54 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-01-03 |
Time |
11:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2017-12-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-12-05 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-12-05 |
Time |
11:41 |
Sent To |
|
|
Notes |
2017-12-05 11:49:12 | BUILDING PLAN REVIEW | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | | | 1ST REVIEW | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROPOSED HOUSE IS LOCATED IN FLOOD ZONE A5 WITH A | | BASE FLOOD ELEVATION (BFE) OF 7 FEET 0 INCHES. | | 2. PROVIDE ELEVATION CERTIFICATE AS FOLLOWS: | | | | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS | | A7 WITH A BASE FLOOD ELEVATION (BFE) OF 7FT. THE CITY | | OF WEST PALM BEACH (THROUGH ORDINANCE) REQUIRES AN | | ADDITIONAL 12 INCHES OF FREEBOARD REQUIRING THE DESIGN | | FLOOD ELEVATION (DFE) TO BE 8. 0 FEET. PLEASE NOTE THIS | | INFORMATION ON YOUR PLANS. | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | REQUIRED AT TIME OF PERMIT APPLICATION. | | NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS | | SITE ARE REQUIRED TO BE AT OR ABOVE 8.0 FEET NGVD. | | | | AN UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | RECOMMENDED. | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2017-10-12 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2017-10-12 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2017-10-12 |
Time |
14:45 |
Sent To |
|
|
Notes |
2017-10-12 14:47:04 | 10/12/17 APPROVED PLUMBING, LAC |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2017-10-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2017-10-25 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2017-10-25 |
Time |
07:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2017-11-16 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2017-11-16 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2017-11-06 |
Time |
16:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2017-10-05 |
|
|
Cont ID |
|
Sent By |
njwira |
Date |
2017-10-05 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
njwira |
Date |
2017-10-05 |
Time |
16:30 |
Sent To |
|
|
Notes |
2017-10-05 17:01:04 | 10/5/17- FAILED | | | | WHERE IS THE A/C UNIT GOING? | | DRIVEWAY IS 22FT. 9IN. EXCEEDS 20FT. MAXIMUM | | MUST PROVIDE A 3FT. SIDE SETBACK FROM THE DRIVEWAY | | MUST PROVIDE 75% OR 1,000SQFT. OF PERVIOUS SURFACE IN | | THE FRONT SETBACK | | WHAT IS THE ROOF OVERHANG? CANNOT EXCEED 3FT. | | | | | | PLEASE CONTACT | | NATHAN WIRA- ZONING TECHNICIAN | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING | | DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS ST. | | WEST PALM BEACH, FL 33402 | | OFFICE HOURS: M-F 8AM - 5PM | | (561)822-1442 | | [email protected] | | |
|
|