Plan Review Details - Permit 17090683
Plan Review Stops For Permit 17090683 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2017-10-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-10-12 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-12 |
Time |
11:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2017-10-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-10-11 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-11 |
Time |
12:52 |
Sent To |
|
|
Notes |
2017-10-11 13:27:55 | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 5TH EDITION (2014). | | | | 1- RAS 117 CALCULATIONS SUBMITTED: | | THE FASTENER SPACING FOR CORNER AREAS WAS CHANGED TO 3" | | O.C.. ACCORDING TO SEC. 8.1 OF RAS 117 "THE MINIMUM | | FASTENER SEPARATION SHALL NOT BE LESS THAN 4 IN. O.C.". | | REVISE AS REQUIRED TO COMPLY. SEC. R301.1 | | FBC-RESIDENTIAL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2017-09-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-09-28 |
Time |
17:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-09-28 |
Time |
16:41 |
Sent To |
|
|
Notes |
2017-09-28 17:47:08 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | CODE: FBC 5TH EDITION (2014). | | | | 1- RAS 117 CALCULATIONS SUBMITTED: | | A) THE ADDRESS SHOWN IS INCORRECT. THIS BUILDING IS | | LOCATED IN WEST PALM BEACH NOT RIVIERA BEACH. THESE ARE | | TWO DIFFERENT MUNICIPALITIES. REVISE AS REQUIRED. SEC. | | 107.2.1 CITY AMENDMENTS. | | | | B) THIS BUILDING IS LOCATED IN EXPOSURE "C" NOT | | EXPOSURE "B". REVISE AS REQUIRED . SEC. R301.2.1.4 | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | C) ACCORDING TO FIGURE R301.2(7) OF FBC-RESIDENTIAL THE | | MINIMUM DIMENSION FOR ROOF ZONES 2 AND 3 IS 4'-0" NOT | | 3'-0". REVISE THE ROOF ZONES DIMENSIONS AS REQUIRED. | | | | D) CLARIFY WHAT'S ASCE 7-0.10 SPECIFIED ON THE MIDDLE | | OF THE SHEET SUBMITTED. DO YOU MEAN ASCE 7-10?. REVISE | | AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2017-10-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-10-12 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-12 |
Time |
11:28 |
Sent To |
|
|
Notes |
2017-10-12 11:35:15 | REVISED RAS 117 CALCULATIONS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2017-10-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-10-11 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-10-06 |
Time |
11:16 |
Sent To |
|
|
Notes |
2017-10-10 11:16:14 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2017-09-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2017-09-28 |
Time |
17:47 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2017-09-27 |
Time |
09:23 |
Sent To |
|
|
Notes |
2017-09-28 09:23:19 | JGOMEZ |
|
|
|