Plan Review Details - Permit 17090437
Plan Review Stops For Permit 17090437
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-01-05 Cont ID  
Sent By shill Date 2018-01-05 Time 16:46 Rev Time 0.00
Received By shill Date 2018-01-05 Time 16:39 Sent To  
Notes
2018-01-05 16:47:08PROVISO
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 PRIOR TO CONCRETE POUR, A FORM BOARD SURVEY WITH
 ELEVATIONS OR AN ELEVATION CERTIFICATE IS REQUIRED
  
 PRIOR TO FINAL INSPECTION, A FINISHED CONSTRUCTION
 ELEVATION CERTIFICATE IS REQUIRED
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-11-27 Cont ID  
Sent By shill Date 2017-11-27 Time 17:30 Rev Time 0.00
Received By shill Date 2017-11-27 Time 17:30 Sent To  
Notes
2017-11-27 17:40:01****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 FROM PREVIOUS LIST:
  
 1. PROVIDE A SITE PLAN SHOWING PROPOSED LOCATION,
 INCLUDING DISTANCE TO PROPERTY LINES AND ASSUMED
 PROPERTY LINES FBC B 705.3.
  
 2ND REVIEW, NO DISTANCES TO THE ASSUMED PROPERTY LINE
 BETWEEN THE TWO BUILDINGS, OR OTHER FORM OF COMPLIANCE,
 WAS PROVIDED.
  
 2. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS
 REQUIRED. CONTACT 561-233-5025 FOR MORE INFORMATION.
 THIS MAY BE DONE AFTER ALL REVIEWS ARE COMPLETE.
  
 3. THIS PERMIT WILL BE ISSUED WITH PROVISO, A "BUILDING
 UNDER CONSTRUCTION" ELEVATION CERTIFICATE WILL BE
 REQUIRED PRIOR TO CONCRETE POUR. A "FINISHED
 CONSTRUCTION" ELEVATION CERTIFICATE WILL BE REQUIRED
 PRIOR TO FINAL INSPECTION.
  
 4. ALL EQUIPMENT SERVICING THE BUILDING WILL ALSO BE
 REQUIRED TO MEET THE MINIMUM ELEVATION OF 17' NGVD29;
 REVISE PLAN WITH A NOTE.
  
 NEW COMMENTS:
  
 5. PROVIDE LEGIBLE PLANS FOR THE MODULAR, FBC 107.
 COMPLIANCE WITH DISTANCE TO THE ASSUMED PROPERTY LINE
 (SEE ITEM 1) REQUIRES INFORMATION SUCH AS THE BUILDING
 TYPE, FBC 107.
  
 6. IF NOT INCLUDED IN THE DCA APPROVAL, PROVIDE AN
 ENGINEERED DETAIL FOR THE FOUNDATION AND TIE DOWNS FOR
 THE PROPOSED MODULAR, FBC B 1609.
  
 7. PROVIDE A NEW PERMIT APPLICATION WITH CORRECT SCOPE
 OF WORK PROPOSED WITH UPDATED VALUE.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-09-27 Cont ID  
Sent By shill Date 2017-09-27 Time 17:33 Rev Time 0.00
Received By shill Date 2017-09-27 Time 17:33 Sent To  
Notes
2017-09-27 17:41:59****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. PROVIDE A SITE PLAN SHOWING PROPOSED LOCATION,
 INCLUDING DISTANCE TO PROPERTY LINES AND ASSUMED
 PROPERTY LINES FBC B 705.3.
  
 2. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS
 REQUIRED. CONTACT 561-233-5025 FOR MORE INFORMATION.
  
 3. THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD
 AREA, MAP PANEL 1202250015B, BFE OF 16'. THE CITY OF
 WEST PALM BEACH MUNICIPAL CODE REQUIRES A FREEBOARD OF
 1'. FBC 1612.3. REVISE PLAN TO INDICATE PROPOSED FFE, A
 MINIMUM OF 17' NGVD29. REVISE SITE PLAN TO SHOW
 ACCESSIBLE ROUTE, INCLUDING ELEVATIONS AND SLOPES, FBC
 A 206.
  
 THIS PERMIT WILL BE ISSUED WITH PROVISO, A "BUILDING
 UNDER CONSTRUCTION" ELEVATION CERTIFICATE WILL BE
 REQUIRED PRIOR TO CONCRETE POUR. A "FINISHED
 CONSTRUCTION" ELEVATION CERTIFICATE WILL BE REQUIRED
 PRIOR TO FINAL INSPECTION.
  
 ALL EQUIPMENT SERVICING THE BUILDING WILL ALSO BE
 REQUIRED TO MEET THE MINIMUM ELEVATION OF 17' NGVD29;
 REVISE PLAN WITH A NOTE.
  
 4. FBC 107, ROUTE INTO THE FUTURE MODULAR NOT CLEAR; IS
 A STAIR/RAMP PROPOSED? REVISE SITE PLAN TO INCLUDE,
 NOTING IT AS "FUTURE".
  
 5. SCOPE NOT CLEAR. APPLICATION IS FOR SLAB ONLY, BUT
 SOME DCA PAPERWORK WAS SUBMITTED. REMOVE (BY VOIDING
 THE SHEETS) OR PROVIDE PLANS AND VALUE FOR PROPOSED
 MODULAR AND RELATED WORK.
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2017-11-27 Cont ID  
Sent By jpearson Date 2017-11-27 Time 09:52 Rev Time 0.00
Received By jpearson Date 2017-11-27 Time 09:46 Sent To  
Notes
2017-11-27 09:52:18ELECTRICAL TO GUARD SHACK ON PERMIT 17110135.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-10-04 Cont ID  
Sent By jpearson Date 2017-10-04 Time 11:44 Rev Time 0.00
Received By jpearson Date 2017-10-04 Time 06:19 Sent To  
Notes
2017-10-04 11:44:02CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND
 SEALED BY A LICENSED DESIGN PROFESSIONAL OR THE
 ELECTRICAL CONTRACTOR QUALIFIER. IF THERE IS NOT ANY
 ELECTRICAL WORK INCLUDED WITH THIS PERMIT, STATE THAT
 ON PLAN. FS 471.003(2)(H); 471.025; FBC 107.2.1,
 107.3.5
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-01-17 Cont ID  
Sent By shill Date 2018-01-17 Time 10:58 Rev Time 0.00
Received By shill Date 2018-01-17 Time 10:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-11-29 Cont ID  
Sent By shill Date 2017-11-29 Time 12:15 Rev Time 0.00
Received By shill Date 2017-11-15 Time 10:49 Sent To I
Notes
2017-11-28 11:58:0211/28 REMOVED FROM BOARD; PICKED UP BY JR
  
  
2017-11-15 10:29:49B14

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-11-15 Cont ID  
Sent By skennedy Date 2017-11-15 Time 10:09 Rev Time 0.00
Received By skennedy Date 2017-09-20 Time 16:31 Sent To  
Notes
2017-09-26 16:31:40B14

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2018-01-17 Cont ID  
Sent By shill Date 2018-01-17 Time 10:58 Rev Time 0.00
Received By shill Date 2018-01-17 Time 10:58 Sent To  
Notes
2018-01-17 10:58:38MU=2018-000743-0000

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-09-27 Cont ID  
Sent By shill Date 2017-09-27 Time 17:42 Rev Time 0.00
Received By shill Date 2017-09-27 Time 17:42 Sent To  
Notes
2017-09-27 17:42:31SEE BUILDING REVIEW
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-11-22 Cont ID  
Sent By ccole Date 2017-11-22 Time 15:02 Rev Time 0.00
Received By ccole Date 2017-11-22 Time 15:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-10-03 Cont ID  
Sent By ccole Date 2017-10-02 Time 10:33 Rev Time 0.00
Received By ccole Date 2017-10-02 Time 10:34 Sent To  
Notes
2017-10-02 10:38:091ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17090437
 10/2/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) REVIEW BUILDING COMMENT #3 REGARDING EXTERIOR
 EQUIPMENT IN A FLOOD HAZARD AREA AND PROVIDE A SITE
 PLAN THAT SHOWS THE LOCATION OF THE AC CONDENSE. REFER
 TO SECTION 301.16:
  
 [B] 301.16 FLOOD HAZARD.
 FOR STRUCTURES LOCATED IN FLOOD HAZARD AREAS,
 MECHANICAL SYSTEMS, EQUIPMENT AND APPLIANCES SHALL BE
 LOCATED AT OR ABOVE THE ELEVATION REQUIRED BY SECTION
 1612 OF THE FLORIDA BUILDING CODE, BUILDING FOR
 UTILITIES AND ATTENDANT EQUIPMENT.
  
 EXCEPTION: MECHANICAL SYSTEMS, EQUIPMENT AND APPLIANCES
 ARE PERMITTED TO BE LOCATED BELOW THE ELEVATION
 REQUIRED BY SECTION 1612 OF THE OF THE FLORIDA BUILDING
 CODE, BUILDING FOR UTILITIES AND ATTENDANT EQUIPMENT
 PROVIDED THAT THEY ARE DESIGNED AND INSTALLED TO
 PREVENT WATER FROM ENTERING OR ACCUMULATING WITHIN THE
 COMPONENTS AND TO RESIST HYDROSTATIC AND HYDRODYNAMIC
 LOADS AND STRESSES, INCLUDING THE EFFECTS OF BUOYANCY,
 DURING THE OCCURRENCE OF FLOODING UP TO SUCH ELEVATION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status P Date 2018-01-17 Cont ID  
Sent By shill Date 2018-01-17 Time 10:59 Rev Time 0.00
Received By shill Date 2018-01-17 Time 10:59 Sent To  
Notes
2018-01-17 10:59:54PROVISO
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 PRIOR TO CONCRETE POUR, A FORM BOARD SURVEY WITH
 ELEVATIONS OR AN ELEVATION CERTIFICATE IS REQUIRED
  
 PRIOR TO FINAL INSPECTION, A FINISHED CONSTRUCTION
 ELEVATION CERTIFICATE IS REQUIRED
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2017-11-27 Cont ID  
Sent By shill Date 2017-11-27 Time 17:41 Rev Time 0.00
Received By shill Date 2017-11-27 Time 17:41 Sent To  
Notes
2017-11-27 17:41:43SEE BUILDING REVIEW
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2017-09-27 Cont ID  
Sent By shill Date 2017-09-27 Time 18:15 Rev Time 0.00
Received By shill Date 2017-09-27 Time 18:15 Sent To  
Notes
2017-09-27 18:15:36SEE BUILDING REVIEW
  
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2017-11-15 Cont ID  
Sent By skennedy Date 2017-11-15 Time 10:27 Rev Time 0.00
Received By skennedy Date 2017-11-15 Time 10:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-10-04 Cont ID  
Sent By gjohnson Date 2017-10-04 Time 12:45 Rev Time 0.00
Received By gjohnson Date 2017-10-04 Time 12:45 Sent To  
Notes
2017-10-04 12:52:291ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE PROVIDE PLUMBING PLAN OR SITE PLAN SHOWING
 LOCATION OF BATHROOM FACILITY'S. PER FBC PL
 403.1/403.3/403.3.3
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2017-11-29 Cont ID  
Sent By JR Date 2017-11-29 Time 11:16 Rev Time 0.00
Received By jroach Date 2017-11-27 Time 10:58 Sent To  
Notes
***NONE***